HomeMy WebLinkAboutEngineering Advanced Architecture & Planning LLC
Architect & Planning
757 NW Waterlily Place
Jensen Beach, FL 34957 (772)631-5709
Windows & Sliding Glass Door Replacement Certification:
July 09, 2016
Bili Laprade
Glass Professionals
Stuart, Florida
Cell: 772-475-3459
Email: glassprofessionals@gmail.com
Project: (3) Single Hung with(2) Mullions& (8) Sliding Glass Door Replacements:
Gladchun Residence, 12494 Harbour Ridge Blvd.Unit 4-2 Palm City,FL 34990
Dear Mr. Laprade:
Please know I personally completed the wind load analysis for the single hung window,the (2)mullions and the
sliding glass door,NOA's, 15-0519.05; 16-0218.03; 15-1210.01 respectfully by PGT Industries, all Impact
rated vinyl.
The glass type can be Type 6, 7 or 8 for the windows and Type 1, 3 or 5 for the SGD with a min. sill height of
3.5" and to be per Table B1 on the NOA. The 1"x2.75"x0.375"minimum, alum. mullion to have a standard clip
with(4) '/4"tapcons, minimum 1.5"embedment in to concrete of filled CMU, top and bottom.
Using the ASCE?-10. The following parameters were used:
Windows & Sliding Glass Doors height is less than 12 feet;
Exposure D; Wind speed 170 mph; Enclosed Structure, wind zones 4 and 5;
When taking into account the external and internal pressure coefficients and adjustments per the ASCE?-10, the
resulting and governing applied wind pressure comes to+49.3 psf/-54.1 psf for the governing Zone 5.
With the tapcon type, spacing, edge distances and embedment and window& door installation completed per
each respective NOA,the allowable loads of+65/-70psf for the windows; +/-58.3psf for the mullions and+/-
60psf for the SGDs exceed the applied loads in these applications, and is acceptable to my office.
It is recommended that all fasteners be of high quality stainless steel.
If you have any questions, please contact meat any time.
Thank you, P�0 OF FLOR�O