HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online https://www.floridabuilding.org/pr/pr_app dd.aspx?param=vGEVX...
-'n•.�,,j,�,n;>�.�,r,:;�� Ems Home lnq in User Registration Hot topics Submt Surcharge Stats&Facts Pubucatbns FBC Staff SCIS Site Map Urks Search
Busines,�% �t'-
Product Approval- s :Pu
u14jon
I!l Nth' l!f F4i P--O-y Anpmvnl�trpu>Vjo�uct or pk ltr9b5eaC4h>PpJ-caSl4a.ltst>Application Detail
FL# FL1956-1112
Application Type
Editorial Change
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer TAMKO Building Products,Inc.
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerd Eden
kerri eden@tamko.corn
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerrl—eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Certification Mark or Listing
Certification Agency UL LLC
Validated By Robert).M.Nleminen,PE
Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
of 4 6/2/2016 10:04 AM
Florida Building Code Online https://www.flofidabuilding.org/pr/pr_app_dti.aspx?param=wGEVX...
Product Approval Method Method 1 Option A
Date Submitted 09/17/2015
Date Validated 10/06/2015
Date Pending FBC Approval
Date Approved 10/09/2015
Summary of_Products ._..._._.- _--_._- _ .. _ . ._. _...,. _.
_ ._.
FL tf Model, Description
Number or }
',Name
1956.1 ;Elite Glass-Seal A three tab asphalt shingle.
Limits of Use y Certification Agency Certificate
Approved for use in + F6,I� 6 RZ2. CAC Ft I56 qli C CAC�s�mk4_SCoFi,156 20I, ,pdf
HVHZ:No f
Approved for use outside ;Quality Assurance Contract Expiration Dat®
HVHZ:Yes 09/17/2018
i Impact Resistant:N/A i Installation Instructions
Design Pressure:N/A F 156 1312 II_GIaSs-_ eal_EILte G1as_s_SeaLap�jlt..,pdf
Other:Asphalt shingles 1 Verified By: Robert Nieminen 59166
shall be used only on roof i Created by Independent Third Party: No
slopes of 2:12 or greater. ?Evaluation Reports
Nails must be used as the i Created by Independent Third Party:
method of attachment.
1956.2 !Glass-Seal A three tab asphalt shingle.
Limits of Use j Certification Agency Certificate
Approved for use in t FL1956_R12 C CAG FL1956 R1,1 C CAC Tamko Sery Conf FI.1956 2015.99-
HVHZ:No I FL1956 Ri2 C CAC UL certificaticn_10 11_12.pdf
Approved for use outside I Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
i Impact Resistant:N/A i Installation Instructions
Design Pressure:N/A I FL195b Ri2 II Glass Seal Elite Glass_$eal app inst.pdf
Other:Asphalt shingles Verified By: Robert Nieminen PE 59166
shall be used only on roof ; Created by Independent Third Party: No
;slopes of 2:12 or greater. 1 Evaluation Reports
Nails must be used as the Created by Independent Third Party:
method of attachment. i
1956.3 Heritage A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
{ Approved for use In &19,56 R12 C CAC E 1956 R11 C CAC Tamko Sery Cohf.FL_1.95b_2015pdf
(HVHZ:No F419S62 C cAG 4!I�certiFicati0lL3..0_1.1-12 pdr
[ Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A i Installation Instructions
Design Pressure:N/A FL1956_gI.2 �I�eCjka-ge_P F ) P app inst,Ddf
t Other:Asphalt shingles Ft i-96�1.2_]�_Her�tage�aDD�n_sS,plf
j shall be used only on roof x.156 R12_L1 hjeritage T app insc pdf
slopes of 2:12 or greater. Verified By:Robert 3.M. Nieminen FL 59166
Nails must be used as the i Created by independent Third Party: No
method of attachment. Evaluation Reports
Created by Independent Third Party:--.. .
1956.4 Heritage 30 f !A dimensional asphalt shingle.
Limits of Use I Certification Agency Certificate
Approved for use in FL1956 Ri2 C CAC FL1956 Rli_C GBC�amko Serv.,Conf FL 1956 2015.99-
;HVHZ:No Ft}�56_R12 C CA_C_UL_certification_3Q I1_12.pdf
Approved for use outside 'Quality Assurance Contract Expiration Date
HVHZ:Yes j 09/17/2018
Impact Resistant:N/A I Installation Instructions
Design Pressure:N/AF1 1956_R12 II heritage 30 app inst a�rll 10 gdf
` Other:Asphalt shingles ! FL1956 Ri2 II heCitage 30 (nstjf april 10_9.9-
;shall be used only on roof Verified By: Robert Nieminen PE 59166
slopes of 2:12 or greater. Created by Independent Third Party: No
Nails must be used as the i Evaluation Reports
method of attachment. s Created by Independent Third Party:
2 of 4 6/2/2016 10:04 AM
Florida Building Code Online hups://www.floridabuilding,org/pr/pr app dtl.aspx?param--wGEVX...
1956.5 ;Heritage 50 !A dimensional asphalt shingle. _---..... ..
-~
i Limits" t -of Use-" I Certification Agency Certificate
j Approved for use in FL3956R12 C CAC FL1956 R11 C CAC Tamko Serv,Conf FL 1956 2015.p_df j
HVHZ:NoI E 1956 R12 C CAG UL certifica i n 1_.il32,Pgf.
Approved for use outside Quality Assurance Contract Expiration Date y
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
! Design Pressure:N/A FL2956 R12 Il eritage 50 app Inst apr�l 1¢p4
I Other:.Asphalt shingles I FL3956 Rl II p-ritage_50--@pp Inst f aprif 10.pdf
I shall be used only on roof ? Verified By:Robert Nieminen PE 59166 }
slopes of 2:12 or greater. ! Created by Independent Third Party: No f
Nails must be used as the ;Evaluation Reports
method of attachment. Created by Independent Third Party:
119S6.6 Heritage 1 A dimensional asphalt shingle. i
Premium
Limits Of Use i Certification Agency Certificate
E Approved for use in FL1956_Ri2 C_G4�FL1956 R11_C CAG Tamko Serv�Conf FL 1956 2015,pdf j
HVHZ:No I p11956 R12 C CAC UL certification 10 11-12.iAl' j
Approved for use outside I Quality Assurance Contract Expiration Date
f HVHZ:Yes j 09/17/2018
Impact Resistant:N/A I Installation Instructions
1 Design Pressure:N/A j FL1956 R12 II Heritage Premium D:P_aQQ InsE.pdf
{ Other:Asphalt shingles I FL1956 R12 II_Heritage_Premium Fapp O_pdf
shall be used only on roof FL1956 R12_II Heritagp Pre iurrT appir1st—pdf
slopes.of 2:12 or greater, i Verified By:Robert Nieminen 59166
;:Nails must be used as the Created by Independent Third Party:No
method of attachment. Evaluation Reports
j Created by Independent Third Party:
1956.7 Heritage j A heavy weight dimensional asphalt shingle.
!" ;Vintage
—
Limits of Use j Certification Agency Certificate 1� i
Approved for use in ! FL1,956 R12 C CAG_F!_1 56�1l_ GAG Tamko Senn Conf_FL-1 56,2035pgL y^j
HVHZ:No ! FI,156 R12�.GAC UL shingle matrixpdf
Approved for use outside 1 Quality Assurance Contract Expiration Date
HVHZ:Yes 109/17/2018 i
Impact Resistant:N/A i Installation Instructions i
? Design Pressure:N/A FL1956 R32 Il_tjeritaggVintage app Inst.Ddf
i Other:Asphalt shingles Verified By: Robert 1.M.Nieminen PE 59166
{shall be used only on roof j Created by Independent Thlyd Party: No i
slopes of 2:12 or greater. Evaluation Reports
Nails must be used as the I Created.by Independent Third Parry:
ii method of attachment.
Vintage e12X12,
1956.8 iHerita a Hip and ridge shingles
_
' Hip and Ridge 1
VV!
I Limits of Use f
Certification Agency Certificate
f Approved for use In FL1956 R32 C CAC FL3956 R11 C CAC Tamko_SeryConf FL 1956 2015.:pdf
j HVHZ:No FL1956 R12 C CAC UL shingle rr_,�_atrix.pdf
( Approved for use outside }Quality Assurance Contract Expiration Date
1 HVHZ:Yes j 09/17/2018 1
Impact Resistant:N/A i Installation Instructions
Design Pressure:N/A FL1956 R12 II TAMKg Herita eQ 12_x12 Hip ard_Rid_ge Application Instructions.odf
Other:Asphalt shingles I Verified By: Robert 1.M.Nieminen PE 59166 j
shall be used only on roof ; Created by Independent Third Party:No
slopes of 2:12 or greater. Evaluation Reports 1
Nails must be used as the j Created by Independent Third Party:
i method of attachment.
1956.9" Heritage j A dimensional asphalt shingle. _
Woodgate
I Limits of use 'Certification Agency Certificate E .
I' Approved for use In FL1956 R12 C CAC FL]956 R11 C CAC Tamko Serv_Conf FL 1956 2015:pdf
f HVHZ:No I-12.p_df
Approved for use outside ;Quality Assurance Contract Expiration Date
I HVHZ:Yes 09/17/2018
( Impact Resistant:N/A r Installation Instructions
Design Pressure:N/A FLi956 R12 !I Heritage Woodgate D_app_insc
Other:Asphalt shingles i EL1956-�R12-II-Herltdgp411oodga-W F appjmt,➢df
1.shall be used only on roof E Verified By: Robert Nieminen 59166
slopes of 2:12 or greater, Created by Independent Third Party:No
3 of 4 6/2/2016 10:04 AM,
Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=WGEVX...
Nails must be used as the y Evaluation Reports
k
method of attachment. s Created by Independent Third Party: s
1956 10 'Heritage XL A dimensional asphalt shin------------
gle.
j Limits of Use 1 Certification Agency Certificate
i Approved for use In f 95b R12 C CAC FL1956 R11 C GAC Tamk_o._Sery Conf FL_1956 2015 pof
HVHZ:No FL1956 R12 C CRC VL certification_30 1.1-1,2�- f 1
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A !Installation Instructions
Design Pressure;N/A I FL1955 R12 II heritage_xl app Inst d aril 10.pdf {
Other:Asphalt shingles k F11956 R12 II heritage xi app inst f RQrill0. Of
I shall be used only on roof Verified By: Robert Nieminen PE 59166
slopes of 2:12 or greater. I Created by Independent Third Party: No
Nails must be used as the Evaluation Reports
method of attachment, ;. Created by Independent Third Party:_
1
i 1956.11 f Hip and Ridge t Hip and ridge shingles
1t
Shingles i
Limits of Use j Certification Agency Certificate
Approved for use in i :FL}956_Rl_2 C CAG FL1956R11 C CAAC Tamko Se-Conf Fi 1956,_201.S,pdf
i HVHZ:No FL1951 R12_C CAC_JL certiFicatlen_fl 11-}2.pdf
Approved for use outside I Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
j Impact Resistant:N/A Installation Instructions f
Design Pressure:N/A (11956 Rl.d ti 12 25x12 Hund Ridoe.n f
Other:Hip and Ridge FI"1956R12 II 12 x 12 HipRidge tipplication Instructions.Ddf i
shingles shall be used only t E14__ R12_)I 12-1 4x12 HipRidge_,Se44ant Dab Illustrdtions.pdf
on roof slopes of 2:12 or FL1956 L-12_11_12x12 Hlpf?idge, ealarlk,Datt_I11t�stratlgnp_d�
i greater.Nails must be used I Verified By: Robert Nieminen 59166 j
as the method of Created by Independent Third Party: No
i attachment. j Evaluation Reports
Created by Independent Third Party:
eatit �j
COA.tact_Us::k240�IRn1LM49C4e fitre �laha54�gFt 131 PL�eAei_0_S0 4QJ 1!!Z4
The Stale of Florida is an AA/EEO employer.f,Qpvrigll O .Q_L:5 (90LFp�lda,::QJxdcy,$tatemeRt::A�cg_s__g1L53atemenl::,gefu atg�,eM
Under Florida law,emal addresses are pubhc records.if you do not want your e-mal address released in response to a pubac-records request,do not send electronic
mal to this entity.Instead,contact the office by phone or by traditional mal.C you have any questions,please contact 850.487.1395.'Pursuant to section
455.275(1),Florida Statutes,effective oetober 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emals provided may be used for official communication wih the licensee.However emal addresses are public record.tf you do not wish to supply a
personal address,please provide the Department wih an emas address which can be made avaaable to the public.To determine If you are a licensee under Chapter
455,F.S.,please click mfg..
Product Approval Accepts:
M <CresIM
cr.vritr.r.
4 of 4 6/2/2016 10:04 AM
Application Instructions for FORMERLY HERITAGE"30
ITA MIK0 HERITAW
BUILDING PRODUCTS LANINATCD ASPHALT SHING16CS
Dallas,TX • Frederick, MD • Joplin, MO 9 Phillipsburg, KS
THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.
TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM
FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS.FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY
AFFECT COVERAGE UNDER THE LIMITED WARRANTY.SEE THE LIMITED WARRANTY FOR DETAILS.
THIS PRODUCT IS COVERED BY A LiMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER.
iN COLD WEATHER(BELOW 40°F),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES.
iMPORTANT,It is not necessary to remove the plastic strip from the back of the shingles.
1.>f 00r DECK 3.rA134K IMS
These shingles are for application to roof decks consisting of plywood WIND CAlITION Extreme wind velocities can damage these
or sheathing boards capable of receiving and retaining fasteners.and shingles after application when proper sealing of the shingles does
to inclines of not less than 2 in.per foot.For roofs having pitches 2 in. not occur.This can especially be a problem 4 the shingles are applied
per foot to less than 4 in.per foot,refer to special instructions titled in cooler months or in areas on the roof that do not receive direct
"Low Slope Application".For roofs having pitches greater than 21 in. sunlight.These conditions may impede the sealing of the adhesive
per foot,refer to special instructions tilted"Mansard Roof or Steep strips on the shingles.The inability to seal down may be compounded
Slope Roof".Shingles must be applied property.TAMKO assumes no by prolonged cold weather conditions and/or blowing dust.In these
responsibility for[oaks or defects resulting from Improper application, situations,hand sealing of the shingles is required.To insure quicker
or failure to property prepare the surface to be roofed over. sealing.apply 4 quarter-sized dabs of 7AM-PRO9 SBs Flashing
Cement,TAMKO or TAM-PRO@ Plastic Roof Cement,or TAMKO
NEW ROOF f7EqKG4 STRUCTION:Roof deck must be smooth, Tam-Seat Adhesive,meeting ASTM D 4586,Type 1,on the back of
dry and free from warped surfaces.It is recommended that metal the shingle 1 in.(25mm)and 13 in.(330mm)in from each side and
drip edges be installed at eaves and rakes. 1 in.(25mm)up from the bottom of the shingle.Press shingle firmly
into the adhesive.For maximum wind resistance along rakes,install
PLYWOO,i>All plywood shall be exterior grade as defined by any TAMKO starter shingle including sealant or cement shingles to
APA - The Engineered Wood Association. Plywood shall be a the underlayment and each other in a 4 in.(102mm)width of TAM-
minimum of 3/8 in, thickness and applied in accordance with the PROD SBS Flashing Cement,TAMKO or TAM-PRO@ Plastic Roof
recommendations of APA-The Engineered Wood Association. Cement,or TAMKO Tam-Seal Adhesive.Caution:Apply ONLY a thin
$HEATHIN( 130ARDS: Boards shall be well-seasoned tongue- uniform layer of adhesive fess than 1/8 in.(3mm)thick.Excessive
and-groove boards and not over 6 in,nominal width.Boards shall amounts can cause blistering of the shingles and may soften the
be a 1 in, nominal minimum thickness. Boards shall be property asphalt in certain underlaymenls resulting in the asphalt flowing.
spaced and nailed. dripping and staining.Shingles must also be fastened according to
the fastening instructions described below.
3,VM"TION Correct placement of the fasteners is critical to the performance of
the shingle.If the fasteners are not placed as shown in the diagram
Inadequate ventilation of attic spaces can cause accumulation of and described below,this will result in the termination of TAMKO's
moisture in winter months and a build up of heat in the summer, liabilities under the Limited Warranty.TAMKO will not be responsible
These conditions can lead to: for damage to shingles caused by winds In excess of the applicable
1.Vapor Condensation mph as stated in the Limited Warranty.See Limited Warranty on the
2.Buckling of shingles due to deck movement. wrapper or tamko.com for details.
3.Rotting of wood members. TENtNG PATTERNS:.Fasteners must be placed 6-1/8 in.from
4.Premature failure of roof. the bottom edge of the shingle,penetrating through the common
bond,and located horizontally as follows:
To insure adequate ventilation and circulation of air,the ventilation 1)Standard Fastening Pattern.(For use on decks with slopes 2
system must include inlets and outlets.This may be accomplished with in.per foot to 21 in,per foot.)One fastener lin.from each end and
a combination of ridge and soffit vents or by using gable end vents. one 13-1/2 in.from each end of the shingle for a total of 4 fasteners.
FHA minimum property standards require one square foot of net tree (See Standard Fastening Pattern illustrated below).
ventilation area to each 150 square feet of space to be vented.This
may be reduced to one square foot of ventilation area per 300 square STANDARD FASTENING PATTERN
feet if at least 40%and not more than 50%of venting is provided 1 FASTENERS NAIL ZONE
not more than 3 feet below the ridge or if a Class I or 11 vapor barrier JcoMMON
is installed on the warm in winter side of the ceiling in climate zones -'--- BOND
6.7.and 8 as recommended by the 2012 International Residential 6-118„ FFXPOI
suaEs•era^
Code.For more information consult your design professional,If the
ventilation openings are screened,the total area should be doubled. 1 12-1/2"—+--12-9/8"—►�— 12 1/2"—*� {�—I„
i_T ts_ ?1i>�Ei1Y iMPORT$M1IJ LQP�t Q�(pl
A_D.ESWATE TNTRATfON. (Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 osneria
Visit Our Web Site at Northeast District 4500 Tamko Dr.. Frederick.MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
t8mko.COR1 Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave.. Denver,CO 80216 800-530-8868 '�
el (CONTINUED from page 1) FORMERLY HERITAGE13 30
TANK HERITAGE"
BU116DING PRODUCTS hAMINATED ASPRMT SHING169S
Dallas,TX & Frederick, MD * Joplin, MO e Phillipsburg, KS
2) Mansard Fastening Pattern. (For use on decks with slopes be a minimum of 1-1/4 in, for new construction and 1-1/2 in.for
greater than 21 in.per toot.)One fastener I in.from each end and reroofing thus allowing a minimum deck penetration of 314 in.The
one fastener B-1/2 in.from each end and one fastener 16 in.from Property Driven Improperly Driven
each end for a total of 6 fasteners per shingle.(See Mansard and
High Wind Fastening Pattern illustrated below.)
MANSARD AND HIGH WIND WARRANTY FASTENING PATTERN
NAILZONE Doc
FASTENERS /COMMON
or BONO
sty EXPOSURE15-5V crown of the staple must be parallel to the length of the shingle.
The staple crown should be driven flush with the shingle surface.
I" Staples that are crooked,underdriven or overdriven are considered
3)High Wind Warranty Fastening Pattern.(For High Wind Warranty improperly applied.
Application requirements)One fastener I in.from each end.One 0_AM_U0N_. ALL FASTENERS MUST BE DRIVEN INTO THE
fastener 8-1/2 in.from each end and one fastener 16 In.from each NAIL ZONE COMMON BOND AS SHOWN IN THE FASTENING
end for a total of six(6)fasteners per shingle. In addition to this PATTERN DIAGRAMS,
shingle fastening pattern requirement for High Wind Application,
TAMKO also requires the use of TAMKO starter shingles including 4.UNOMMYMENT
sealant strip at eaves and rakes.Alternatively,along rakes,cement UNDeRLAYMM An underlayment must be applied over the
shingles to the underlayment and each other in a 4 in.(102 Trim) entire deck before the installation of TAMKO shingles,Failure to add
width of TAM-PRON)SIBS Flashing Cement,TAMKO or TAM-PRO@ underlayment can cause premature failure of the shingles which is
Plastic Roof Cement,orTAMKO Tam-Seal Adhesive.Caution:Apply not covered by TAMKO's Limited Warranty.
ONLY a thin uniform layer of adhesive less than 1/8 in.(3mm)thick.
Excessive amounts can cause blistering of the shingles and may Products which are acceptable for use as underlayment are:
soften the asphalt in certain underlayments resulting in the asphalt Asphalt SajijrALFeAl
-Undsstaymen s:
flowing,dripping and staining. Of-
* SuperX 30T11 Underlayment
High Wind Application is offered on new construction or complete - TAMKO,No.15 Asphalt Saturated Organic Felt
tear-off applications only.It is not offered for recover applications. v Any TAMKO non-perforated asphalt saturated organic felt
It High Wind Application requirements are not followed, the High - A non-perforated asphalt saturated organic felt which meets
Wind Application Warranty MPH,as stated on Table I in the limited ASTM:D226,Type I or 11 or ASTM D4869
Warranty,reverts to the Standard Application Wind Warranty MPH Spgcialty UndgrIgyments:
limit. (See Mansard and High Wind Fastening Pattern illustrated
above.) a Tarn-Shields Synthetic Underlayment or Synthetic Shield
KAIL% Underlayment TAMKO recommends the use of nails as the preferred method - TAMKO TIN Metal and Tile Underlayment,TW Underlayment
of application. Standard type roofing nails should be used. Nall and Moisture Guard Plus@ (additional ventilation may be
shanks should be made of minimum 12 gauge wire,and a minimum required. Contact TAMKO's Technical Services Department
head diameter of 3/8 in.Nails should be long enough to penetrate for more information.)
3/4 in.into the roof deck.Where the deck is less than 3/4 In.thick, a A self-adhesive underlayment designed for use with asphalt
the nails should be long enough to penetrate completely through shingles which meets ASTM D1970.
plywood decking and extend at least 1/8 in.through the roof deck.
Drive nail head flush with the shingle surface. F_p_r_A sp-tiall-SA(trate dlo A1_Undff10_Vm_eM%
Apply the felt when the deck is dry.On roof decks with slopes
ptawdyoaven 4 in.per foot and greater apply the felt parallel to the eaves
0-:2firmIntome" and-fti— ovoddvm cmato lapping each course of the felt over the lower course at least
2 in.Where ends join,lap the felt 4 in.If left exposed,the felt
may be adversely affected by moisture and weathering.Laying
of the felt and the shingle application must be done together.
-WA j24%
For All Other Saei-,t eflavfn t
_qn
mdf1u&h%6thW4*D1**uffam ivr=aft' hm a*'O. mcm)"ga On roof decks with slopes 4 in, per foot and greater apply
the underlayment parallel to the eaves in accordance
STAPLES:If staples are used in the attaching process,follow the with underlayment written application instructions. The
above instructions for placement.All staples must be driven with underlayment should not be felt exposed for a longer period of
pneumatic staplers.The staple must meet the following minimum time than is specified in the underlayments written application
dimensional requirements.Staples must be made from a minimum instructions.The final roof covering must be installed before
16 gauge galvanized wire.Crown width must be at least 15/16 in. the structure is exposed to adverse weather conditions,such
(staple crown width is measured outside the legs).Log length should as wind driven rain,high wind,hail,ice storms.etc. (Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09119114
Visit Our Web Site at Northeast District 4500Tamkd Dr., Frederick.MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 2
_0 (CONTINUED from page 2) FORMERLY HERITAG010
ITANKU HERITAGE"
WMINATC0 ASPHNS SHING16C
RUMING 0-80-0-UCTS Dallas,TX # Frederick, MD * Joplin, MO 9 Phillipsburg, KS
in areas where ice builds up along the eaves or a back-up of water of shingle to start the fourth course and use the remaining 10-3/8
from frozen or clogged gutters is a potential problem.TAMKO's in.piece to begin the fifth course.Continue up ft rake in as many
Moisture Guard Plus",TW Metal and Tile Underlayment or TW rows as necessary using the same formula as outlined above.
Underlayment (or any specialty eaves flashing product) may be The butt of the shingle should be aligned with the top edge of the
applied to eaves,rakes,ridges,valleys,around chimneys,skylights sawtooth of the underlying shingle for a 5-5/8 in. exposure(see
or dormers to help prevent %vater damage. Contact TAMKO's shingle application drawing illustrated on this panel). When you
Technical Services Department for more Information. make your final cut at the roof's edge,flip any pieces that are 8 in,or
Substitute products as shingle underlayment should not be used. longer back onto the roof.These pieces can be worked in anywhere
without creating zippers or color variations.
S.APPLICATION INSTR0C8110NS NODE;Do not align joints of shingle courses when working in cut
STARTER COURSE;A starter course may consist of TAMKO Shingle pieces.Joints should be no closer than 4 in.from one another.
Starter,TAMKO 10-inch Starter or self-sealing 3-tab shingles.If self-
sealing 3-tab shingles are used,remove the exposed tab portion and
install with the factory applied adhesive adjacent to the eaves.Attach tcw.ymvlrjfww�rote 10" 29.m,a 1031tr
the starter course with approved fasteners along a line parallel to
and 1.5 in.to 3 in.above the eaves edge.The starter course should
overhang both the eaves and rake edges IM in.to 3/8 in.if drip edge
flashing is not used along the eaves or rakes.If drip edge flashing
is present,install shingles even with the drip edge.
TAIM0 W_g.-Ole-keov"V�d.�).svgsIL
.Weour�i�d 0.41�.'.�r Ow— d
TAIA PROS SM FW,_,gCmmTW."0�,TAM-ORW
...... ............................. MMIP' -d IQ 3�11,15e:X
!�k%S
K-4-.7 Or
f—A-9, . . . . . .
ar
'Oa14n.. I,PW P14Pla.J." "-W t* �1 V ——anomer,
ltrawxo Ll.W_W1,NO
O!A-ld to 3*
6.LOW SLOPE APPLICATION
SHINGLE APPLICATION Start the first course with a full size shingle On pitches 2 in,per foot to 4 in.per foot cover the deck with two
and overhang the rake edge 1/4 in.it drip edge is not present.it layers of underlayment.Begin by applying the underlayment in a
drip edge is present,align shingle edge with drip edge flashing.Cut 1/2-sheet width along the eaves and overhanging the drip edge
10-3/8 in.from a full shingle to form a shingle 29 in.long.Use this by 114 to 3/4 in.Place a full-sheet Width over the 1/2-sheet width
to start the second course(see diagram below).Cut a 23 in.long starter piece,completely overlapping it.All succeeding courses will
shingle to start the third course.Use the remaining 16-3/8 in.piece be positioned to overlap the preceding course by 1/2-sheet width.
If winter temperatures average 251F or less, thoroughly cement
the laps of the entire underlayment to each other with TAM-PRO
or TAMKO Plastic Roof Cement from eaves and rakes to a point
1-1-7 - i of a least 24 in.inside the interior wall line of the building.As an
21r
alternative,TAMKO's Moisture Guard Plus",7W Metal and Tile
23' Underlayment. or TW Underlayment self-adhering underlayment
may be used in lieu of the cemented felts.
coin
ra KZ 23- Fn is 3ra^ 21: 7.MANSARD ROOF OR STEEP SLOPE ROOF
4-10-318, If the slope exceeds 21 In.per foot(60).each shingle must be sealed
Sm coumwith TAM-PRO@ SBS Flashing Cement,TAMKO or TAM-PROQD
4th 09'm Plastic Roof Cement or TAMKO Tam-Seat Adhesive immediately
t6 3tA'
upon installation.Quarter-sized dabs of cement or adhesive must
J be applied to shingles with a 5-5/8 in.exposure,use 6 fasteners per
2nd evurse shingle.See Section 3 for the Mansard Fastening Pattern.
to co" . ..... JContinued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09119114
Visit Our Web Site at Northeast District 4500 Tamko,Dr.. Frederick.MD 21701 $00-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamkoxom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868
(CONTINUED from page 3) FORMERLY HERITAGE"30
ETA:IMKo HRRITA6R®
BUILDING PRODUCTS LAMINATED ASPHALT SHING6ES
Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
8.MOWING 8.VALLEY APPLICATION
Before re-roofing,be certain to inspect the roof decks.All plywood shall Over the shingle underlayment,center a minimum 36 in,wide sheet of
meet the requirements listed in Section 1. Moisture Guard Plus',TW Metal&Tile Underlayment,or a minimum
It is not recommended to install laminated asphalt shingles directly 50 Ib. roll roofing in the valley. Nail the underlayment only where
over existing laminated shingles due to the unevenness of the existing necessary to hold it in place and then only nail the outside edges.
multilayered shingles.The performance of the sealant feature may be IMPORTANT.PRIOR TO INSTALLATION WARM SHINGLES TO
compromised,preventing the shingles from sealing property.It is PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING
acceptable to install laminated shingles over existing three-tab strip SHINGLES TO FORM VALLEY.
shingles which are flat and essentially intact Nail down or remove curled
or broken shingles from the existing roof.Replace all missing shingles After valley flashing is in place:
with new ones to provide a smooth base.Shingles that are buckled Apply the first course of shingles along the eaves of one of the
usually indicate warped decking or protruding nails.Hammer down all intersecting roof planes and across the valley.
protruding nails or remove them and refasten in a new location.Remove
all drip edge metal and replace with new. Note:For proper flow of water over the trimmed shingle,always
If re-roofing over an existing roof where new flashing is required to start applying the shingles on the roof plane that has the lower
protect against ice dams(freezelthaw cycle of water and/or the backup slope or less height.
of water in frozen or clogged gutters),remove the old roofing to a point Extend the end shingle at least 12 in.onto the adjoining roof.
at least 24 in.beyond the interior wall line and apply TAMKO's Moisture Apply succeeding courses in the same manner,extending them
Guard Pius TW Metal and Tile Underlayment,or TW Underlayment. across the valley and onto the adjoining roof.
Cont=t TAMKO's Technical Services Department for more information.
Measurements will vary when nesting over an existing 5 in,exposure • Press the shingles tightly into the valley.
single roof:Call TAMKO Technical Services for further information. • Use normal shingle fastening methods.
The nesting procedure described below is the preferred method for Note:No fastener should be within 6 in.of the valley centerline,
reroofing over existing metric size shingles with a 5-518 in.exposure. and two fasteners should be placed at the end of each shingle
See description below: crossing the valley.
$tatter Course:Remove the tabs and an additional portion from the . To the adjoining roof plane,apply one row of shingles vertically
head of a full size shingle so that its height is equal to the exposure of facing the valley and 2 in.back from the valley centerline.
the existing shingles.Position the resulting strip over the existing roof
edge(with the factory-applied adhesive strip along the eaves).Cut Note: For a neater installation, snap a chalkline over the
approximately 6 in.from the rake end and apply the remaining portion at shingles for guidance.
the eaves.Continue the starter strip by applying full length shingle strips To complete the valley, apply shingles on the adjoining roof
cut to height as above,evenly along the existing roof at the eaves.The
existing roof should overhang the eaves far enough to carry water plane by positioning the tip of the first shingle of each row at
off into the gutter.If this is not the case,cut and apply the starter the 2 in.point from the centerline where the edge of the vertical
strip so that it will provide sufficientoverhang for proper drainage. shingle has been applied,covering the vertical shingle.
•,r ��i' '> "' hinimum 34'%tido sheat Vaeoy centerbnu
65"o,. of hld.hun Guard Ptus,
TwMetal&
.�' Extra ndt in
'�\ i3tra•� ,`t'' 1 tt ��''� Tee or 50 ib-or
.{�� ;�,' �., Lz;r•/� ,\��j :> hamo,rat feelicg ettdNstin�t
Exteml end sNng!e
12-18'ba-Vond
lxvayo-'' `,:!'JCQ r ..{ l // •i" vAlldy centetfine
,,�� ' r'.Y'"'"•. � Ntl laste'tera within
6'of co tedne
F►st nurse:Remove an amount from the butt edge of a full-size shingle f
so that the remaining portion of the shingle fits between the butts of the
existing third course.This course must also be applied evenly along the
eaves edge of the new starter strip, Place fp of slwgk,on the edge of
the.,WicA shm j*2 in,-,hes back
E2tif�11 4pSd ltt9 C24rse ;Remove 10-3/8 in.from the rake trom wiley comnng
end of the first shingle in the second course,and continue with full th0 veiveaf shtnu!a
width shingles for the remainder of the course,placing the top edge of
each new shingle against the butt edge of the old shingle in the course FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE
above.This method should create an exposure of 5-5/8 in.after the first CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT
course.When beginning the succeeding courses continue to follow the 800-641-4691.
Heritage application instructions.(See section 5).
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09119;14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.eom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver.CO 80216 800-530-8868 4
(CONTINUED from page 4) FORMERLY HERITAGE"'30
ITANK01immi ue
BU1160ING PRODUCTS LAMINATED ASPHAIMT SHINGLES
Dallas,TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
10.HIP AND HME FASTEIIiiNG DETAIL
Apply the shingles with a 5-1/8 in.exposure beginning at the bottom
of the hip or from the end of the ridge opposite the direction of the
prevailing winds.Secure each shingle with one fastener on each side,
5-5/8 in.back from the exposed end and 1 in.up from the edge.
TAMKO recommends the use of TAMKO Hip & Ridge shingle
products.Where matching colors are available,it is acceptable to
use TAMKO's Elite Glass-Seal shingles cut down to 12 in.pieces.
Fasteners should be 1/4 in.longer than the one used for shingles
IMPORTANT, PRIOR TO INSTALLATION, CARE NEEDS TO BE
TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE
BENDING SHINGLE IN COLD WEATHER.
Direction of prevailing wind
Start 6-1/8"exposure
hors;
'�n •:i'�Fnslener
Start
- — hero 5-1I8"exposure
THESE ARE THE MANUFACTURER'S APPLICATION
INSTRUCTIONS FOR THE ROOFING CONDITIONS
DESCRIBED.TAMKO BUILDING PRODUCTS, INC.ASSUMES
NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
DEFECTS RESULTING FROM FAILURE TO FOLLOW THE
MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW
THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE
UNDER THE LIMITED WARRANTY. SEE THE LIMITED
WARRANTY FOR DETAILS. IF YOU HAVE ANY QUESTIONS
REGARDING THESE APPLICATION INSTRUCTIONS, PLEASE
CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT
800-641-4691.
Information included in lbese application Instructions was current at time of printing.To
obtain a copy of the most current version of these application Instructions,•risit us onllne
at tamko.cdm or call us at 800-641-4691.
TALMO.Moisture Guard Mus®.Tam-Shielde,TAM-PR010 and Herita3v0 aro registered
trademarks and SuperX 30 is a trademark of TAMKO Building Products.Inc.
Central District 220 West 4th St., Joplin,MO 64801 800-641.4691 09/19114
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 5
JP69909