HomeMy WebLinkAboutEngineering 1;COOK & MENARD ARCHITECTURE INC. 806 Delaware Avenue, Fort Pierce, Florida 34950 PHONE(772)460-7751 FAX(772)460-4244 EMAIL cookmenard@yahoo.com July 6, 2016 St. Lucie County Building Department Attn: Roof Permit Plan Review 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at 790 Brocksmith Rd., St. Lucie County, Florida Manufacturer: Gulf Coast Supply.&Manufacturing Profiles: 5V Crimp Metal Panel FL.#11651-112 Code: FBC 2014;Section R 905 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 30' Maximum Pitch: 4"/12" Required Design Pressure: Zone1:-38.2 Zone 2:-53.9 Zone3:-101.4 Maximum Uplift Pressure: Fastener spacing:Zone 1, 2, & 3 -108.5 @ 12" o. c Fasteners: #9-15 x 1-Y2"stainless steel panel tite with sealing washer, &%" min penetration. Underlayment: Ice and water shield peel &stick or 30#felt complying with/ASTM D226 Type II installed with spaced 6" o.c.on laps and 12" o.c. staggered in field. Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x2"ring shank nails @ 6" o.c.thru out Zone 1,4" o.c. perimeter& 6" o.c.field Zone 2,and 4" o.c.thru out Zone3 The above approved,as per Florida Building Code Compliance acceptances, 2010 Florida Building Code, and the Manufacturer's recommendations. Respectfully Submitted, Peter B. Cook Cook&'Menard Architecture, Inc. Florida Registration No. AA0003494, NCARB Certification No. 31789