a FL# FL11651-R2
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived .
Product Manufacturer Gulf Coast Supply&Manufacturing, LLC.
Address/Phone/Email 4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352)498-7852
ray@gulfcoastsupply.com
Authorized Signature Ray Bowen
ray@gulfcoastsupply.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered.Architect o
Florida Professional Engineer
'. Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Daniel S. Kuhn
the Evaluation Report
Florida License PE-75519
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/12/2024
Validated By Locke Bowden
Validation Checklist- Hardcopy Received
Certificate of Independence FL11651 R2 COI Cert of Ind Kuhn Engpdf
FL11651 R2 COI Letter of Name chanoe.odf
of 7 3/11/20169:16 AM
lorida Building Code Unlme nUp:nwww.IlonaaouuaMg.orgtpripr__dpp—gU.aspx:pUM111—wvn v'N...
Referenced Standard and Year(of Standard) Standard Year
FM 4471 1992
TAS 100 1995
TAS 110 2000
TAS 125 2003
UL 1897 2004
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 07/01/2015
Date Validated 07/10/2015
Date Pending FBC Approval 07/18/2015
Date Approved 08/18/2015
Summary of Products
Go to Page F
FL# Model, Number Description
or Name
11651.1 0.032" 0.032" 5 V Crimp Aluminum Roof Panel over 15/32" Plywood
Aluminum 5V
Crimp
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 1 R2 0325vCrimp 15-32Plywood NonHVF
HVHZ: No FL11651 R2 II 14FL11651 1 R2 Metal Roof Panel Detall.pdf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 1 R2 0325vCrimo 15-32Plvwood NonHV
Pressure: +N/A/-108.5PSF Created by Independent Third Party: Yes
Other: -108.5 psf @ 12" o.c.
Install per manufacturers
details. Not for use in HVHZ
Zones.
11651.2 0.032" 0.032"Aluminum Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Aluminum Gulf
Lok
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 2 R2 032GulfLok 16 15-32Plvwood NonF
HVHZ: No FL11651 R2 II 14FL11651 2 R2 Metal Roof Panel Detail.odf
Approved for use outside .Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 2 R2 032GulfLok 16 15-32Plvwood Non
Pressure: +N/A/-116.OPSF Created by Independent Third Party: Yes
Other: -52.5 psf @ 5 3/16"
o.c. fastener spacing. -116.0
of7 3/11/2016 9:16 AM
lornaaBunamgc:oaevnlme nuP://www.ijurivaouuuuig.urg/pripr_app :piva111—wvnvn...
psf @ 5 3/16" o.c. fastener
spacing. Install per
manufacturers details. Not for
use in HVHZ Zones.
11651.3. . . . .1" 24ga. Gulf 1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood
Snap
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 2 R2 Metal Roof Panel Detail.pdf
HVHZ: Yes FL11651 R2 II 14FL11651 3 R2 1 24GulfSnap 17 15-32Plywood H\
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ: Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 3 R2 1 24GulfSnap 17 15-32131vwood H
Pressure: +N/A/--131.OPS Created by Independent Third Party: Yes
Other: -67.3 psf @ 24"o.c.
clip spacing. -131 psf @ 6"o.c.
clip spacing. Install per
manufacturers details. For use
in HVHZ Zones.
11651.4 1" 24ga. 1"VersaLoc 24ga 16.5" Wide Roof Panel over 15/32" Plywood
Versa Loc
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 4 R2 24VersaLoc SR 16.5 15-32Plvwood
HVHZ:Yes FL11651 R2 II 14FL11651 4 R2 Metal Roof Panel Detail..pdf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party: Yes .
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 4 R2 24VersaLoc SR 16.5 15-32Plywood
Pressure: +N/A/-138.5PSF Created by Independent Third Party: Yes
Other: -71 psf @ 24" o.c. clip
spacing. -138.5 psf @ 6" o.c.
clip spacing. Install per
manufacturers details. For use
in HVHZ Zones.
11651.5 1"VersaLoc 1"VersaLoc .032"Aluminum over 15/32" Plywood
.032"Aluminum
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 5 R2 lin 032VersaLoc SR 16 15-32PIvwc
HVHZ:Yes FL11651 R2 II 14FL11651 5 R2 Metal Roof Panel Detail..pdf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZp Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 5 R2 lin 032VersaLoc SR 16 15-32PIvw
Pressure: +N/A/-101.OPSF Created by Independent Third Party: Yes
Other: -63.3 psf @ 24" o.c.
clip spacing. -101.0 psf @ 6"
o.c. clip spacing. Install per
manufacturers details. For use
in HVHZ Zones.
11651.6 1.5" 24ga. Gulf 1.5"Gulf Snap 24ga. 16"Wide Roof Panel over 15/32" Plywood
Snap
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 6 R2 1.5 24GulfSnap 16 15-32Plywood
HVHZ:Yes FL11651 R2 II 14FL11651 6 R2 Metal Roof Panel Detail..pdf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 6 R2 1.5 24GulfSnap 16 15-32Plywood
Pressure: +N/A/=116.OPSF Created by Independent Third Party:Yes
of 7 3/11/2016 9:16 AM
�dorida Building Code Onime nttp://www.rionaaoutiamg.orgipr/pr_app_an.aspx:param=vvr VA...
Other: -86.0 psf @ 24" o.c.
clip spacing. -108.5 psf @ 12"
o.c. clip spacing. -116.0 psf @
6" o.c. clip spacing. Install per
manufacturers detals. For use in
HVHZ Zones.
11651.7 1.5" 24ga. 1.5"VersaLoc 24ga. 16"wide Roof Panel over 15/32" Plywood
VersaLoc
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II.14FL11651 7 .R2 1.5 24VersaLoc 16 15-32Plvwood I
HVHZ: Yes FL11651 R2 II 14FL11651 7 R2 Metal Roof Panel Detail..odf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 7 R2 1.5 24VersaLoc 16 15-32Plvwood
Pressure: +N/A/-123.5PSF Created by Independent Third Party: Yes
Other: -59.75 psf @ 24" o.c.
clip spacing. -123.5 psf @ 12"
o.c. clip spacing. Install per
manufacturers details. For use
in HVHZ Zones.
11651.8 2" 24ga. 24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32" Plywood
MegaLoc
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 8 R2 24MeoaLoc 18 15-32Plvwood NonH
HVHZ: No FL11651 R2 II 14FL11651 8 R2 Metal Roof Panel Detail.pdf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 8 R2 24MeaaLoc 18 15-32Plywood Nonl
Pressure: +N/A/-108.5PSF Created by Independent Third Party: Yes
Other: -71.0 psf @ 24" O.C.
clip spacing. -108.5 psf @ 12"
o.c. clip spacing. Install per
manufacturers details. Not for
use in HVHZ Zones.
11651.9 24 Ga. Gulf Lok 24 Ga. Gulf Lok 16"Wide over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 9 R2 24GulfLok 16 15-32Plvwood NonH%
HVHZ: No FL11651 R2 II 14FL11651 9 R2 Metal Roof Panel Detail.odf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 9 R2 24GulfLok 16 15-32Plvwood NonH
Pressure: +N/A/-96.7PSF Created by Independent Third Party: Yes
Other: -81.75 psf @ 10-1/4"
o.c. fastener spacing. -96.76
psf @ 5-1/8"o.c.fastener
spacing. -121.75 psf @ 5-1/8"
fastener spacing. -161 psf @
5-1/8"fastener spacing. Install
per manufacturers details. Not
for use in HVHZ Zones.
11651.10 24 Ga. Gulf 24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood Purlins over 15/3-
Seam
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 10 R2 24GulfSeam 16 1x4 15-32Plvwoo�
HVHZ: No FL11651 R2 II 14FL11651 10 R2 Metal Roof Panel Detail.pdf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
•of7 3/11/2016 9:16 AM
'lorida Building Code Onlme. ntip:iiwww.nonaaouilamg.orgipripr_app_ati.aspx:param—wtin v n...
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 10 R2 24GulfSeam 16 1x4 15-32Plvwoc
Pressure: +N/A/-93.5PSF Created by Independent Third Party: Yes
Other: -93.5 psf @ 18"o.c.
Install per manufacturers
details. Not for use in HVHZ
Zones.
11651.11 24 Ga. Gulf 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel over 15/32" PI
Seam
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 11 R2 24GulfSeam 18 15-32Plywood No
HVHZ: No FL11651 R2 II 14FL11651 it R2 Metal Roof Panel Detail.pdf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 11 R2 24GulfSeam 18 15-32Plvwood Nc
Pressure: +N/A/-108.5PSF Created by Independent Third Party: Yes
Other: -69.25 psf @ 24" o.c.
clip spacing. -108.5 psf @ 12"
o.c. clip spacing. Install per
manufacturers details. Not for
use in HVHZ Zones.
11651.12 26 Ga. 5V Crimp 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 12 R2 265vCrimp 15-32Plywood HVHZ.o
HVHZ:Yes FL11651 R2 II 14FL11651 12 R2 Metal Roof Panel Detail.pdf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 12 R2 265vCrimp 15-32Plvwood HVHZ.[
Pressure: +N/A/-156.5PSF Created by Independent Third Party: Yes
Other: -108.5 psf @ 12" o.c.
fastener spacing. -156.5 psf @
6" o.c. fastener spacing. Install
per manufacturers details. For
use in HVHZ Zones.
11651.13 26 Ga. 5V Crimp 26 Ga. 5V Crimp over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 13 R2 265vCrimp 15-32Plvwood NonHVF-
HVHZ: No FL11651 R2 JI 14FL11651 13 .112 Metal Roof Panel Detail.pdf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 13 R2 265vCrimp 15-32Plvwood NonHV
Pressure: +N/A/-131.PSF . Created by Independent Third Party: Yes
Other: -94.25 psf @ 16" o.c.
fastener pattern. -131.0 psf @
16" o.c.fastener pattern: Install
per manufacturers details. Not
for use in HVHZ Zones.
11651.14 26 Ga. 5V Crimp 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 14 R2 265vCrimp 1x4 15-32Plywood Noi
HVHZ: No FL11651 R2 II 14FL11651 14 R2 Metal Roof Panel Detail.pdf
Approved for use outside Verified By: Dan Kuhn, P.E. 755.19
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 14 R2 265vCrimp 1x4 15-32Plvwood Nc
of 7 3/11/2016 9:16 AM
,loriaaBuilding uoae Vnllne nup://www.110rivaouuuuig.urgipripr_dpp_u�i.UhPX:pacaui—Wur;vn...
Pressure: +N/A/-156.5PSF Created by Independent Third Party: Yes
Other: -108.5 psf @ 12" o.c.
fastener spacing..-156.5 psf @
6" o.c.fastener spacing. Install
per manufacturers details. For
use in HVHZ Zones.
11651.15 1.26 Ga. Gulf Lok 26 Ga. Gulf Lok 16"Wide Roof Panel over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 15 R2 26GulfLok 16 15-32Plvwood HVHd
HVHZ:Yes FL11651 R2 II 14FL11651 15 R2 Metal Roof Panel Detail.odf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 15 R2 26GulfLok 16 15-32Plvwood HVH
Pressure: +N/A/-161.OPSF Created by Independent Third Party: Yes
Other: -63.5 psf @ 5 3/16"
o.c. fastener spacing. -121.75
psf @ 5 3/16"spacing. -161.0
psf @ 5 3/16"o:c. fastener
spacing. Install per
manufacturers details. For use
in HVHZ Zones.
11651.16 26 Ga. Gulf Lok 26 Ga. Gulf Lok 16" Wide Roof.Panel over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 16 R2 26GulfLok 16 15-32Plywood NonF
HVHZ: No FL11651 R2 II 14FL11651 16 R2 Metal Roof Panel Detail.pdf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 16 R2 26GulfLok 16 15-32Plywood Non
Pressure: +N/A/-63.5PSF Created by Independent Third Party: Yes
Other: -63.5 psf @ 5 3/16"
o.c. fastener spacing. -121.75
psf @ 5 3/16"fastener spacing.
-161 psf @ 5 3/16".fastener
spacing. Install per
manufacturers details. Not for
use in HVHZ Zones.
11651.17 26 Ga. GulfPBR 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 17 R2 26GulfPBR 15-32Plvwood NonHVHZ.pdf
HVHZ: No FL11651 R2 II 17 R2 Metal Roof Panel Detail.pdf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 17 R2 26GulfPBR 15-32Plywood NonHVHZ.pdf
Pressure: +N/A/-154.7PSF Created by Independent Third Party: Yes
Other: -59.25 psf @ 24" o.c.
fastener pattern. -154.75 psf @
12"o.c.fastener pattern. Install
per manufacturer details. Not
for use in HVHZ
11651.18 26 Ga. GulfPBR 26 Ga. GulfPBR Roof Panel over 1x4 Wood Purlins over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 18 R2 26GulfPBR 1x4 15-32Plywood HVI
HVHZ:Yes FL11651 R2 II 18 R2 Metal Roof Panel Detail.pdf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation,Reports
of 7 3/11/2016 9:16 AM
loriaa bunamg uoae mime nLtp://W W W.IIUFIUUUUlluulg.Ul-glpf/pr dpp_4LI.USp2L f paraul—W Vn y ll...
Design FL11651 R2 AE 14FL11651 18 R2 26GulfPBR 1x4 15-32Plvwood H�
Pressure: +N/A/-151.7PSF Created by Independent Third Party: Yes
Other: -100.5 psf @ 24"D.C.
fastener spacing. -151.75 psf @
12"fastener spacing. Install per
manufacturer's details. For use
in HVHZ Zones
11651.19 26 Ga. GulfPBR 26 Ga. GulfPBR over 15/32" Plywood
Limits of Use. Installation Instructions
Approved for use in FL11651 R2 II 14FL11651 19 R2 26GulfPBR 15-32Plvwood HVHZ.i)
HVHZ:Yes FL11651 R2 II 19 R2 MetalRoof Panel Detail.Ddf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party: Yes
Impact Resistant: N/A Evaluation Reports
Design FL11651 R2 AE 14FL11651 19 R2 26GulfPBR 15-32Plvwood HVHZ.G
Pressure: +N/A/-154.7PSF Created by Independent Third Party: Yes
Other: -60.5 psf @ 24"D.C.
fastener spacing. -154.75 psf @
12" D.C. fastener spacing. Install
per manufacturer's details. For
use in HVHZ Zones.
11651.20 26 Ga. GulfPBR 26 Ga. GulfPBR over 1x4 Wood Purlins over 15/32" Plywood
Limits of Use Installation Instructions
Approved for use in FL11651 R2 II 20 R2 26GulfPBR 1x4 15-32Plvwood NonHVHZ.pdf
HVHZ: No - FL11651 R2 II 20 R2 Metal Roof Panel Detail.pdf
Approved for use outside Verified By: Dan Kuhn, P.E. 75519
HVHZ:Yes Created by Independent Third Party:'Yes
Impact Resistant: N/A Evaluation Reports
Design FLi1651 R2 AE 20 R2 26GulfPBR 1x4 15-32Plywood NonHVHZ.pdf
Pressure: +N/A/-151.7PSF Created by Independent Third Party: Yes
Other: -94.25 psf @ 24" D.C.
fastener spacing. -151.75 psf @.
12"fastener spacing. Install per
manufacturer's details. Not for
use in HVHZ Zones .,�►
Go to Page YP 00 F
Back Next
Contact Us:: 1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.:: Privacy Statement::Accesslbllty Statement:: g
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records req
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department wl
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.II
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if yo
Chapter 455,F.S.,please click here.
Product Approval Accepts:
® ® eGhEc
y(:CU17t"M TRIC',
1
of 7 3/11/2016 9:16 AM
Gull 'Coag
SUPPLY & fVIANUFACTURlNC,
5VCRIMP
If 26 GA. 5VCRIMP
ROOF PANEL OVER • •
NO. 11651.12 .y
Product Evaluation Report
GULF COAST SUPPLY& MANUFACTURING, LLC,
26 Ga. 5V Crimp Roof Panel over 75132" Plywood
Florida Product Approval #11651.12 R2
Florida Building Code 2014
Per Rule 61 G20-3
Method: 1 =D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 61 G20-3.005(1)(d)
HVHZ
Product Manufacturer:
Gulf Coast Supply & Manufacturing, LLC.
14429 SW 2nd Place, Suite G30
Newberry, FL 32669 %.aP1EL 1 �
` NS
kG
.,GENS. y,=
Engineer Evaluator: �.
Dan Kuhn, P.E. #75519 No. 7S51g p
10743
Florida Evaluation ANE ID:
-o-
'STATE OF
AI
Validator: OR1D.P
Locke Bowden, P.E. #49704 `'�.S�0 AL
9450 Alysbury Place
Montgomery, AL 36117 0,0 02.015
Contents:
Evaluation Report Pages 1 - 5
FL#11651.12 R2•JUNE 15,2015
KUHN ENGINEERING, LLC
11670 1 SLA ND LA KES LAN E, B OCA • FL 33 498 COA#3 0464
'Co,a t
P A I o 6D Gull
SUPPLY & MANUFACTURING
5 V C R I R.,
• • ROOF PANEL OVER • •
F ORIDA PRODUCT APPROVAL 'IO-
i - 11651.12 y
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2, 1518.9, 1523.6.5.2.4.
Product Description: 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage,through fastened
roof panel with fasteners in the panel flat over minimum 15/32" plywood
decking. Non Structural application.
Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2014 Section 1507.4.3.
Paint Finish Optional
Yield Strength: 50.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2014, Section 1507.4.3.
Panel Dimension(s): Thickness: 0.018" Minimum
Width: 24" Coverage
Rib Height: 3/8" Major Rib
Panel Fastener: #9-15x1.5" with sealing washing through panel rib.
1A" minimum penetration through plywood.
Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4
Substrate Description: Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C.
Design of plywood and plywood supports are outside the scope of this evaluation.
Must be designed in accordance w/Florida Building Code 2014.
Design Uplift Pressures: Table"A"
� ,
IN
Fastener Pattern Panel Rib Panel Rib
Design Pressure includes a Safety Factor=2.0.
FL##1165112. -R2•JUNE 15,2015
ISLANDKUHN
LAKES LANE,• • RATON, 17L 33498 FL • 430464
n SUPPLY S MANUFA%�URING
FLORIDAGul CoA
5VCRIF' 11
26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD*
PRODUCT APPROVAL
. i.,, O. 11651.12 R
1 PA
Code Compliance: The product described herein has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2, 1518.9, 1523.6.5.2.4.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind.load
requirements of the Florida Building Code 2014, as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
• TAS 125-03
• UL 580-06-Test for Uplift Resistance of Roof Assemblies
• UL 1897-04- Uplift Test for Roof Covering Systems.
• TAS 100-95 -.Test Procedure for Wind and Wind Driven Rain
Resistance of Discontinuous Roof Systems
• TAS 110-00-Accel. Weathering ASTM G 155/Salt Spray ASTM
B 117.
Reference Data: 1. TAS 125-03: UL 580-94/ 1897-98 Uplift Test
Force Engineering &Testing, Inc. (FBC Organization #TST-5328)
Report No. 117-0065T-07A-C, Dated 01/26/2007
2. TAS 100-95
Farabaugh Engineering &Testing, Inc. (FBC Organization #TST-1654)
Report No.T130-07, Dated 02/28/2007
Report No. T215-08, Dated 07/08/2008
3. TAS 110-00:Valspar Fluropon coated metal panel testing
A)ASTM G 26 by PRI Asphalt Technologies dated 01/19/2004
B)ASTM B 117 by PRI Asphalt Technologies dated 01/19/2004
4. Certificate of Independence
By Dan Kuhn, P.E. (FL#75519)@ Kuhn Engineering, LLC
(FBC Organization #ANE ID: 10743)
Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test
standard.
3. ASTM G 155 is equivalent to ASTM G26
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61 G20-3.005(3)for
manufacturing under a quality assurance program audited by an approved quality
assurance entity.
FL#{11651.12 R2•JUNE 15,2015
KUHN ENGINEERING, LLC
11670 ISLAND LAKES LANE,BOCA RATON, • #30464
11M EMU
SUPPLY & lVIAMUFACTURI3VG
a Gull 'Coa�
Al
mi
5 V 0" Rftll I` r
26 GA. 5VCRIMP ROOF PANEL OVER • •
FLORIDA PRODUCT APPROVAL N00. 11651.12 R2
TM
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including
Section 1515.2 and in accordance with Manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps.
Installation: Install per Manufacturer's recommended details and RAS 133.
Underlayment: Per Manufacturer's installation guidelines per Florida Building Code 2014 Section
1518.2, 1518.3, 1518.4.
Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory
listing for fire ratings of this roofing system assembly as well as the location of the
fire barrier within the assembly. Fire classification is not part of this acceptance.
Shear Diaphragm: Shear Diaphragm values are outside the scope of this report.
Design Procedure: For roofs within the parameters listed on the load table,fastening pattern must
at a minimum meet those listed for the applicable wind zone. For all roofs outside
the parameters listed on the load table, design wind loads shall be determined
for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10
using allowable stress design.The maximum fastener spacing listed herein shall
not be exceeded.
FL#11651.12 R2.•JUNE 15,2015
KUHN ENGINEERING, LLC
11670 ISLAND LAKES LANE, • COA 00464
t t r..r.� wr M,U
J
I RA"Fe
5V - ' R :-d
26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD*
FLORIDA PRODUCT APPROVAL NO. 11651.12 1.12 2
ENOINEER • . ..
!•'t rr�'"{ ,"J .'i,f! [ +_..z-,..r. r '''I!Nltt. :'s' r Y�-,,u1i�.. ,,�„�u�,. '^'c'"'�-' �-.'...- ',_.;;�
�ai�I"�IL'?.,'f.�4'„z w,,!a•n,,*:,I,-G..,,:.�+Jk,r:'?,=,sIFr,•f�..n•x14.Cr:'y:,l�I l,7.t!rt`1!.drUti)f.,l!r.a!.f.;.:�rr1<a'-'A:�.N,lI�.1lv..l..IJ"•„u4c<Jln_e,�3:�.,..«{�..{-u„,�t...v,a.�i.„:°.,t�.,.��..:v>,!::�"Imf`�...}`�'a,:1,t1Yll-fl•te�u#i,l,.�.rxI,”�!r t.•.�F7,�>k_;•�,,:�;.f.,!'.Jtn.o-�t.r.;.!:if!.:��i.-ie•-.i.C,�yv�`�P�Y•d�,.„:,i,,4�:l:+a.�rl,r.,,..t...,k_y't.,1tu��b.�,l,l.,.,{l;.:r,1��ds!t,;�"a r,,.!iJi,�..rf,l�f.!.,I':,;l..�.k,.n�.r�!.fr,.n.�dl..1t:a..Q.i:!�.�,,r.V1,..=a•-.snkr1.:l,,�<y.htYyi�.:ltflU.Ji„3„•r�,,•l��:!4;nt?,,ze-,�!.�m�IFsw..n,^,,a,'>.�r.;3t.(y;.1��L�s.:1l1rI,,e11;.��R,.f,:s.:4.(:..�1„t.;.•.:,.,Vl,,1°y�3.-^jra,-n-�f.pX,fV#�.�1.311,�.,1.�-_��,5i..rf:yj.,r!1;.,..{,.,.�.r,X.�f.,.,.��tNJII,,.J;.r3J..,i�i:fJ:,,I.1,aI,,��,:',I.:.1..i,.,,,.:I...;,_fi:iI�,.Lxr,r',.”y.,AI�.-Y,,'.I,t!�4,r+r,1r11".u!,,�-,,.�tk.:e�l,..•�f.f:�:.f, �4uul�l{„,�Ic�i,•4f,;�I i_-IL
�1,r1 !'h: t>J�..<.�a,7;r,...'.+I�•',-@lN�.Il_I«_-1.lF!,i6t.I'�.haI,'�..�ua��.ul,..`,,,,t,t►:�,a t,•,�,�1.-.,1<„..,,:•�,:.�.=!i..rt1Jf,�91�,��;[I;a(l'=�ia.'+.'1.,.J,,!..,:d•(.:,•1f.f;:Ii{:;�.J';'.,�:,1'!I,„<!I!,l,rI!If,.,il;1,�;!:;fi,h;:]wt.1i,n!]Jt�;,7;,,I.!'f.�.;.�;itU!h:1'fli11!It:a�[i,•,!l�-�•?(,gif:.",'fe�r,+�h•,f,_n�;:�t:�(�.I:.4:,:{i•_ti:l��I!�,'14..:_..;;,•!�.,—,��:L!j.'j-�'S_a�',J=a._.I;�1�,-1.,1!sa1tt.J1a'.,
�:-1huf-I�',!I{I;Ny._:.-.j!.Y{s_•a.:�;,:'J•...'�x1-_tIt;�L,II.I.1�_tt q1-;1�.�j'sIr�1,+i
!:
Ye-
.
t-
WIND FASTENEFM SU BSTRATE
SPEED Penetration)
SPACING SPACING
Mfr.. fi�rr{@±. !•p! i' '7I!I!l i3t r+.':.!Ji l!� t<`1,@- - T'ri rYi.-!gg'.- `'f'��,'•�v �1,t� '',"^C f�+r ;:.:��'`u:z»"?'.p:J� 1!ll6'U +L t'=-s.:.! t{!;,�t,'1. ,.a4.. !i 1,
'l. .I'f!''7e' ���,�*..�7)�ff. »v # +c.',',,'amu yf,•tna'j:: .'-3,.:x'tir: rftrx .@s, �2:tn4.�...a �jl.{F.1•(I J,.v f.-+ - - u.p•-,::
R S eY`.ri:. ,•�• f f`j'fi t. Rum}"%" P`s�*fe + #. t�. !. .ln.,ii a.11�1 i!1ry '.pI N. rJtrz,^13_E !} j:.II F j•'SJ d -
. „1,: , 7 P, « :z:l,.
y,! A; !!!!rI i txk h �� a r. }`c u, ...., 1 {�� f (3� C.:t.,i 7 .n•. _== r...,�
rsltlf.. c��I��_ 'I',(I�:tll.!�ai11:1iI,�EI llIil,u^III:f.:S,,:,..:,`,c''a"7.4"M&@fit�uvaecx..^-a,w..Y:i c.:v�3• �.Y�Lh'.i'IAl�.:'i....,:aL=f:: �;;1ui���,u!:,6•.:,:r.!_i;;:�>�''.,='^:..—sf: n;i;=-`a=,.;"�.:..-`.�:..;.
7^•�wsz<r�-.`c"-': 'vuMmu o,rY"r,!_E 4 ''t'tt!I inp,••pp,•ul,:�..sx-
i��'Tt�` ._• s '�+k �r ! r �r�fldr.�•7wf �!
tbF x. y . ya. J, ''t'ylt7a ,b,ani ism.,t"i I, ;":f, �I r r !I1{i. :"llv• 7'..
.g � 3s:. {Il 1 1..,Sta,y;.,y#f ,• ,t,v ;,{pi• :�,, t �f,h11 II{11 ;1 �I �( a
# v1!I
r=n_ a�
j '�,l�3,:•s,.! 1! -..r•_x+_31!!I;' y
e8,f
� x t i cry. �.;~vu— wi 1'rs �t~'� , 1K1 _�#Pr {I•` �r F FI11 k.,,+,_ !,II '] .l+ll _ _ ; 1 a la' 1 it {,
:7"}.�!! :qk s.,�...a J!,�1��"ylhlllli�I�Itl� �i� �v !!I!'kF�� {��� t 4�t�I �Ir•t�r ' i��I� ��jll 1� 11
t 1
���� . r �,•Lr <��! v.o-_ � 4 a.!('! NN I Itrti ftf'x� hl,s;, � "I! 7, '�,+'1�" .�.,r.,L ��•1 J ,
tt(.!.1._.-_ ,y;Xl�{! 4c�-.1 -�e. �,� e .� it-:_e1(- e•,,,:,,13 ..,n. �: e>�.r,.,w. "#�,+,11� .1 ,!,Ir s�,l`li=,�,:�.'I 3,�:"`'iii �°Q" "7,iii! ,
.•..2 .f.�'t,al:,,s:�.:,.,1,4,�; �,,.. rry.r�l� �,.?.:. ,. .r
3 ,� 4N.,..�,.!n..,,..uf 14 r+��-�7- f��t'�;t:•Iy�,�"i41r!!;;i,�,, -.:!.q r,:,rrJ �`4r,<:�Irina,: # 1,1.,.i
i{,��!:.,,I!!•h::_...i l�lillu,,! I,!I t;�l�•a'r�•r •!„--�a�';_v J` f l.. ,;�`,-•-`s•-- ,� � {r µ1 r III�.:.:f • ,�I{,I I.hI,N;!'
Ari,t- >, t17't t !f, F s„y r'::? ,.i.�'-, j .,..:e�I v1 !..@ nr. .r - �'r' vlt't m'+.t�-. a�e,i•<.�a ,1 1 S{ IJp..;�.{!If:i E� t !• •,'' f
y:l I4N, ,� , ..It p; f 94. ,.Rgr,}�.a,t,r ur•. d .uaa Nil std Y:j:
-,(,1 k ..,_gA...._�:nYw•tr,:i.., ..L,..�tr,,.;:_r^ #� ,r : ,.t!`!!I.Frei• ,f Y ... _:'!.Ya, ..ti: .:r:= �••r...'-.:-n •'ty n;f .Mc.rw.,.._ m'
{,,.. rx.,.y.. ..
Rill; 4 J:reg..:. ?.I?, 1 .Y`.:.!I!.:nf,•�t Y 7s. k�3, g :..7 .... - r.".•.^'. ._t;y,;. ,+ c. !
,.tt,I �. r.�,t'�tl''•r Ir,;✓,: y, �r ��!k�!t`h.,-�''�c•,a_v.:Y,gq'.�.`�T}^_ •�• `<:,iir�S3scs,•,t�'iYi�i ...... It 1 ..-1?! ...�,.ti:,.,r
•'.,-Y,i.4.(tdr 'jE(fflil r'�n;� `•a.�3� ckai7yr.F„a;, iT��ExJeU._csz6=:xR?.V. ,: •.E. i.•..frn,.-�r�1:�9��.�1} .a3.'�,Y:• .
t111I :,.:-:�_,._ •Y. . - ..i ,s i?-'�`�'':,u•,:;;. � I''!,,d., ccl•: ,,,ry'i7'�li ,,:i:{llc,. d` K i 5 .y ._ �!y. t •t •�?�E: �::`:_f�i`•nY•i':t+'.�is".•�'.c•Fs,-'�'.,=:iP
r:z>r�,. .,, .'�v�.-,� .,� ��.•�..�„11.,�,{I� ati ,, :n;,:,h!t.�.11 ,:11.{�II•Ui,., •wr 'N i,f_L -'y!-�1,-. �, - r_ ._,�Y-�...-r,•,. ,�•:z�.z f,i..,�:.._._. �. _:'�
.r ..i'.4::« q:, - ,.afl.,: ,1,wrt,. - •s.-� .-I.fl„�If 1.r., i'>-� -§ o:,..y. .'z'r`3r,o,::T.P.�>;;�• !y,•;::-�=-_=rA'mr:=lcy>,:•s
. ,pf<e ,C,#.a ..s . 5'Tt=.,.,t,`v.7..,:+; , -!s'. .Jir;;•:t•i.I,1In.rY!:::l�e `3f.�: `' Lfr,f,(�ti'I,,- ,,.£,5�. :a;?!;;"1'` __ - .,;;;„_ �,; �'.
t! w!t�.,.._,. r 1:�_..:i. ':,B::•cra,4.: A ! .t'e,. ,..1 6 '� :-f: s Z,.artgs:�� � fl i, - •'��?!�� d.._I f•�f,�',1:"w4i: 5v' r>1 l !N'ii;{I ! half a`.. r,r:: 1,. ,, m !,.r.._aS�=..: r.;.,�`rt(;fp'In��! -I '�'ni.,r, �.v1 � `k ,o-x�4-r,.=�., .kt ,,.. { ttt !!!., 1� t +1;:',� !i i ;t•t i � y!t �!1'i i,
,.-r- ;, �„•- I ,.:._._'ts<�r !4 i !b� III ! J ,=::�!rj n' „'1 .? ,:..z P � �_,�> E �;x m �" .•.,.,,I,{•
,fi�-y ,�-�;.�, . :.,#, ram�:;��1 � ,y n r �!.�.,�-� 41f1,
� i -.L,r»Ld, "�c.a�.?' 1 i.''tt•.,I!;,I ,11•9 ,°I!f�!+.: ' .•y E } n (F .,1 1#. �`.`-s fl 1:h�+�Y.,wie” n, �'i�"?.13
-,:.�. - !, �• � y -� r.„ •II ! 'v�, ?.!.'�
r� �- �! �`
'r.��:;t!',}•''�. a•,i: }F...i�7• �I+U'.. , .r> >i �! `'
I��tU�,u I!r , I� u!�i�•1� .,,.-u Ir!.-!1�!d! .x i r-•f�'�•��f I�.� iN: �{"'I� yl!.: ,�1 �'+4t�(� !IIii�.!�,!l��I!r.r�14,I
h l {1111 ii, !. �I� 11MOM _' L i M , y I 1 I la {r'!Ju I , �'ry I•, 1 I `I'ui' ''L �III!Ill� �,,1.1 �� �,'1
�f!�'r,'1 1,!Jv J .,::,.�.•U:i�' ��_...,s,.`nru_.��.. ...�r'li<7Gi h'�.ai-.�.,.�2.L i� �I'lc�al. �41 �.. ..3m,5. ,1�1�I!i��i�i;I;�";�Irf! '1Hiiu!Il I.�hVEI .,:,:.II 1 1
A
`� a .�.. � •+�- '� +.r1utn Fcfi a '°z* k-•�''g',.ar+7 '`t�3 ,,��c 'r }mT
�rr ,� �,�� `�,..y�aa��'�.��'��i'..!,�i',i;Yi�S,f �.G�x �"' Yni'����` �����.r�r�:�fw��7��� 1..•.�:.
KUHN ENGINEERING, LLC
11670 ISLAND LAKES LANE,BOCA RATONI, FL 33498 • FL COA#30464
Guli 'coa�
.l'� +fJ , `*rXi - Y n"^.S�•tYY✓Eyl»J luta '^ Y F,TT °'C1 CY '{'w S�"'^' � SUPPLY & MANUFACTURING
.� .'tt;�, _�......�.,„�;;+"' ,�.•�'.Fn�,':ye +"3+-a�:'rk.s"f�t'��.7:.ii�1f,a � ...+c.*�...: tzzf�' ..�:-�, .��� �3..f-_.y..'`.'a
�, � 26 GA. SVCRIMP ROOF PANEL OVER 15/32" PLYWOOD*
a.
• • Washer
1211 . 1211
� •
. - . •
• ,
FL#11651.12 R2 JUNE 15,2015
=IN
r � 7�ruaaffi�tz�` ,111ET��1�� R042 f y .ss 1.$.L..... t. 'f ..e.in. ,�.tY 'f�-finer r.._.�.a•,r .4.x,..{.�..tx� �tt7...0
:.i
' I{U'I�IN ENGIN.FERl:NG, LLC
11670 ISLAND L;AI<ES I_,ANE, I30CA RATOI��, FL 33498 • FT_,COA X30464
-'lorida Building Code Online http://www.tloridabuilding.org/pr/pr_app_dti.aspx'!param=w(jEvx...
r
S S
ti"eZ '_"- "W!—pjig,
L ... ¢� ,.-#—..c.....F.y � i° ..:.�� ..—.. ._.. _..� ._,!1 E - s'4`,o�y�m",�ry vauw
BCLS Home Log In ; User Registration i Hot Topics Submit Surcharge Stats&Fac[s Pubikatlons i FBC Staff BCLS Site Map Links I Search
Busines
� �j®r Professio al Product Approval
USER:Public User
?aQt��c?ilGr}
p�qduct Aonroyai Menu> > >AppBotlon Detail
i
FL# FL2569-R9
- Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer SopremaaInc. Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memath leu@soprema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu @soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote,Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M.Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality.Assurance Contract Expiration Date 10/16/2017
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL2569 R9 COI 2015 01 COI Nieminen.ndf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM D6163 2000
ASTM D6164 2005
of 2 7/14/2015 7:39 AM
Florida Building Code Online llttp://www.tioriaabu11c1mg.org/pr/pr_app_gtl.aspx-tparam=WkibvA...
FM 4474 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
TAS 110 2000
Equivalence of Product Standards
Certified By
Sections from the Code
'Product Approval Method Method 1 Option D
Date Submitted 04/17/2015
Date Validated 04/21/2015
Date Pending FBC Approval 04/25/2015
Date Approved 06/23/2015
Date Revised 06/29/2015
Summary of Products
FL# Model,Number or Description
Name
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL2569 R9 II 2015 04 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
Approved for use outside HVHZ:Yes R9.Ddf
Impact Resistant: N/A Verified By: Robert Nieminen,P.E.PE-59166
Design Pressure:+N/A/-90 Created by Independent Third Party:Yes
Other: 1.)Refer to ER Section 5 for Evaluation Reports
Limits of Use.2.)The design pressure FL2569.R9_AE,2015.04.FINAL ER SOPREMA CA UNDERLAYMENTS.FL2569-
noted herein pertains to underlayment R9.pdf
systems used beneath adhesive-set tile Created by Independent Third Party:Yes
systems.Refer to ER Section 5.6.4 for
details.
Backl Next
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Fbrida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your a-mall address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395."Pursuant to Section
455.275(1),Florida.Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address ff they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here-.
Product Approval Accepts:
N4.0 ® —=-
scLurity% !1tlLS'
of2 7/14/2015 7:39 AM
EXTERIOR RESEARCH&DESIGN,I.I.C.
Certificate of Authorization#9503
J I
TRINITY 'ERD OXFORD,353 CHRISTIA �CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT -
Soprema,Inc. Evaluation Report S18010.06.09-117
1640 rue Haggerty FL2569-R9
Drummondville,Quebec J2C 5138 Date of Issuance:06/15/2009
Canada Revision 7:04/17/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use .of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
`,tsls�talrrn.,,r-�
x....... r.e�
Robert l.M.Nieminen P.E. �0�.-p �T,�, The facsimile seal appearing was authorized by Robert Nieminen,
Nieminen,
��+�F•• C t„`••"{:,•' P.E.on 04/17/2015.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983 ��!�,��� ,al document.Signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity]ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity]ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
Which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity]ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
�RIIERE
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following
sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2004
1507.2.4,1507.2.8,1507.2.9.2, Physical Properties ASTM D1970 2009
1507.4.5.1,1507.5.3,1507.7.3
1507.11.2 Physical Properties ASTM D6163 2000
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
TAS 110 Accelerated Weathering TAS 110 2000
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
infiiy Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-111 04/18/2007
ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-R1 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.10-Ri 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.09-112 10/05/2010
ERD(TST6049) ASTM D1970 537210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Physical Properties/Accelerated Weathering SOPC-SC8520.14 04/17/2015
M-D(CER1592) HVHZ Compliance 09-1005.02 11/04/2010
M-D(CER1592) HVHZ Compliance 13-0530.02 11/27/2014
ICC-ES(EVL2396) 2012,2009 and 2006 IBC Compliance ESR-1524 10/01/2014
PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.30/16/2017
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self-adhering,non-woven polyester fabric surfaced,SBS modified bitumen roof underlayment.
4.2 Lastobond Shield is a self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment available
in two widths;36 and 45 inch.
4.3 Lastobond Shield HT is a self-adhering,woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment.
4.4 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths;36 and 45 inch.
4.5 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment.
4.6 Lastobond 195 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
4.7 Lastobond is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
4.8 Lastobond Eco is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R7
Certificate of Authorization#9503 FL2569-119
Revision 7:04/17/2015
Page 2 of 6
INI
4.9 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof
underlayment.
4.10 Resisto LB1236 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment,with
a 36-inch sheet width.
4.11 PrimeSource Grip-Rite Eave &Valley Protector is a self-adhering, glass-mat reinforced, sand-surfaced,SBS modified
bitumen roof underlayment,with a 36-inch sheet width.
4.12 Resisto LB1244 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment,with
a 44-inch sheet width.
4.13 Colphene FR GR is a self-adhering,fiberglass reinforced,granule-surfaced,SBS modified bitumen roof underlayment.
4.14 Unilay (e) is a mechanically attached, polyester reinforced, granule-surfaced, SBS modified bitumen roof
underlayment.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this
product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation
combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are follows:
TABLE 1:ROOF COVER OPTIONS
Underlayment Asphalt Wood Shakes&
Nail-On Tile Foam-On Tile Metal Slate
Shingles Shingles
Lastobond TU HT Yes Yes Yes Yes Yes Yes
See 5.5.1
Lastobond Shield/Pro HT-N Yes No No No Yes Yes
Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes
Lastobond/Lastobond 195 Yes No No No Yes Yes
Lastobond ECO /Resisto LB3236,
Grip-Rite Eave&Valley Protector/ Yes No No No Yes Yes
Resisto LB1244
Lastobond Smooth Seal HT Yes No No Yes Yes — Yes
Colphene FR GR Yes Yes Yes No Yes Yes
See 5.5.1
Unilay(e) Yes Yes Yes No No No
Batten Only See 5.5.1
5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless tensile adhesion/long term aging data from an
accredited testing laboratory is provided.
Underlayment Adhesive(s)
Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH7160(FL6332)or Dow Chemical TileBondT"Roof
Tile Adhesive(FL717)
Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R7
Certificate of Authorization#9503 FL2569-119
Revision 7:04/17/2015
Page 3 of 6
l"RINITY ERD
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:
Lastobond Shield,Lastobond Pro HT-N,Lastobond Shield HT or Lastobond Pro HT-S applied to:
➢ Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine;ASTM D41 primed structural concrete.
Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, Resisto LB1236, Grip-Rite Eave & Valley Protector,
Resisto LB1244 or Lastobond Smooth Seal HT applied to:
➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
➢ Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates,Soprema recommends priming with
Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours.
➢ Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N,Lastobond Shield HT, Lastobond Pro HT-S or Colphene FR
GR applied to:
➢ DensDeck DuraGuard;DensDeck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturers Product Approval. For installations under foam-on tile
systems,insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J.
5.6.3 Bond to Mechanically Attached Base Laver:
Lastobond Shield,Lastobond Pro HT-N,Lastabond Shield HT,Lastobond Pro HT-S or Colphene FR GR applied to:
➢ ASTM D226,Type I or 11 felt;Sopra-G;Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems,base layer shall be attached in accordance with
FRSA/TRI April 2012(04-12).
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on the systems,where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for
determination of design wind pressures.
5.6.4:1 Maximum Design Pressure=-45.0 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)Elastocol Stick or Elastocol 600c
Underlayment: Colphene FR GR,self-adhered.
5.6.4.2 Maximum Design Pressure=-67.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Elastocol 600c
Underlayment: Colphene FR GR,self-adhered.
5.6.4.3 Maximum Design Pressure=-60.0 psf.
Deck: • Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC
1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c.in three,equally spaced rows in the
center of the sheet.
Underlayment: Colphene FR GR,self-adhered
Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-R7
Certificate of Authorization#9503 FL2569-R9
Revision 7:04/17/2015
Page 4 of 6
TRINITY:ERD
5.6.4.4 Maximum Design Pressure=-90.0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Underlayment: Unilay(e)mechanically attached with Soprafix Polymer Batten Bar(PBB)or Soprafix Metal Batten
Bar (MBB) with Soprema #15-EL fasteners spaced 6-inch o.c. within the 5-inch wide, self-
adhering side laps. End laps are 6-inch wide and sealed using either heat-welding or hot-air
welding techniques.
5.7 Exposure Limitations:
5.7.1 Lastobond Shield,Lastobond Pro HT-N,Lastobond,Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,Resisto
LB1236, Grip-Rite Eave&Valley Protector or Resisto LB1244 shall not be left exposed for longer than 30-days after
installation.
5.7.2 Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation.
5.7.3 Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for longer than 180-days after installation.
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate with Elastocol Stick or Elastocol 600c(if applicable).
6_3 Lastobond TU HT Lastobond Shield, Lastobond Pro HT-N, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond,
Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, Resisto LB1236, Grip-Rite Eave & Valley Protector.
Resisto LB1244 or Colphene FR GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the
type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
While priming is optional,Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover
is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release
film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane
tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and
staggered not less-than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using
either heat-welding or hot air welding techniques.
When installing at slopes above 8:12,Soprema recommends back-nailing in the overlap area at the top of the sheet
at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over
valley or ridge.Drape and press sheet into place,working from the center of the valley or ridge in each direction. For
valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Lastobond TU HT or Colohene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For Colphene FR GR in foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance
limitations.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-117
Certificate of Authorization#9503 F1.2569-119
Revision 7:04/17/2015
Page 5 of 6
6NRD
6_4 Unila e:
6.4.1 Non-Tile Applications or Nail-On,Battened Tile Applications:
Reference is made to Table 1 herein and FRSA/TRI April 2012(04-12)Installation Manual(if applicable).
Apply sheet parallel to the roof edge and,starting at the eave with the selvedge-edge upslope, mechanically attach
the 5-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap-nails spaced 36-inch o.c. Apply
the second course in a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller
pressure is applied to the self-adhering laps to ensure a watertight application.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-
granule end-laps shall be sealed using either heat-welding or hot air welding techniques.
Tile (if applicable) shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment
6.4.2 Foam-On Tile Applications:
Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein.
Apply sheet parallel to the roof edge and,starting at the eave with the selvedge-edge upslope,mechanically attach
the 5-inch wide selvedge-edge to the wood deck Soprafix Polymer Batten Bar(PBB) or Soprafix Metal Batten Bar
(MBB)with Soprema#15-EL fasteners spaced 6-inch o.c. Apply the second course in a water-shedding manner with
self-adhering side-laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a
watertight application.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-
granule end-laps shall be sealed using either heat-welding or hot air welding techniques.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damageto the underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
S. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-R7
Certificate of Authorization 89503 FL2569-R9
Revision 7:04/17/2015.
Page 6 of 6