HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2
(� BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map L
[Buv�S,fi[sness'/ry�3� 4�L
Product Approval
I rofessibnaUSER:Public User
Product Approval Menu.>Product or Application Search>Application List>Application Detail
i .,..w„:..._, FL# FL15216-R2
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer InterWrap, Inc.
Address/Phone/Email 32923 Mission Way
Mission,NON-US 00000
(551)574-2939
mtupas@intervvrap.com
Authorized Signature Eduardo Lozano
elozano@interwrap.cam
Technical Representative Eduardo Lozano
Address/Phone/Email 32923 Mission Way
Mission, NON-US 00000
(778)945-2891
elozano@interwrap.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licen
Professional Engineer
- Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nleminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity Intertek Testing Services NA Inc. - ETL/Warnock Hersey
Quality Assurance Contract Expiration Date 11/17/2015
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL15216 R2 COI 2015 01 COI Nleminen. dl`
Referenced Standard and Year(of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
1547.2.3
1507.5.3
1507.8.3
1507.9.3
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVNQwtDgv... 7/13/2015
Florida Building Code Online Page 2 of 2
1507.9.5
T1507.8
Product Approval Method Method 2 Option B
Date Submitted 04/28/2015
Date Validated 04/29/2015
Date Pending FBC Approval 05/04/2015
Date Approved 06/23/2015
Summary of Products
FL# Model,Number or Name Description
15216.1 RhinoRoof Underlayments Synthetic roof underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15216 R2 II 2015 04 FINAL ER INTERWRAP RHINOROC
Approved for use outside HVHZ:Yes R2pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See ER Section 5 for Limits of Use. Evaluation Reports
FL15216 R2 AE 2015 04 FINAL ER INTERWRAP RHINOROI
R2;pdf
Created by Independent Third Party: Yes
Back Next
Contact Us::1940 North Monroe street,Tallahassee FL 32399 Phone,850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacy Statement:.Accessibility Statement::Refun
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records requeE
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.135
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department v
address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public ri
not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To de
are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
cl WW E` M
sccunt, .
http://www.floridabuilding.org/pr/pr_app_ dtl.aspx?param=wGEVXOwtDgv... 7/13/2015
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
T ��I� 353 CHRISTIAN STREET, UNIT#13
'R ERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Interwrap, Inc. Evaluation Report 140510.02.12-112
32923 Mission Way FL15216-R2
Mission, BC V2V-6E4 Date of Issuance:02/17/2012
Canada Revision 2:04/27/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: RhinoRoof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 3.
Prepared by: '„bt;itt.rp.,�—"
".
1 _
Robert J.M. Nieminen,P.E. iV•��gr The facsimile seal appearing was authorized by Robert Nieminen,
!p„�a t�rt<<� P.E.on 04/27/2015.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983 document.Signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity)ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: RhinoRoof Underlayments, as produced by Interwrap, Inc., has demonstrated compliance with the
intent of following sections of the Florida Building Code through testing in accordance with applicable sections of the following
Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Properties Standard Year
1507.2.3,1507.5.3,T1507.8, Unrolling,Breaking Strength,Pliability,Loss ASTM D226 2006
1507.8.3,1507.9.3,1507.9.5 on Heating
1507.2.3,1507.5.3,1507.8.3, Unrolling,Tear Strength,Pliability,Loss on ASTM D4869 2005
1507.9.3 Heating,Liquid Water Transmission,
Breaking Strength,Dimensional Stability
3. REFERENCES:
Entity Examination Reference Date
ITS(TST1509) Physical Properties 100539395COQ-006 10/27/2011
ITS(TST1509) Physical Properties 100539395COQ-002 10/27/2011
ITS(TST1509) Physical Properties 100539395COQ-006 03/14/2014
ITS(QUA1673) Quality Control Inspection Report 11/17/2014
4. PRODUCT DESCRIPTION:
4.1 RhinoRoof U20 is a multilayered polymer woven coated synthetic roof underlayment intended as an alternate to ASTM
D226,Type I or Type II felt or D4869 Type II felt. RhinoRoof Underlayment is available in 42-inch wide rolls,and can be
produced in various other sizes.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory or test
report from accredited testing agency for fire ratings of this product.
5.4 RhinoRoof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation
combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop RhinoRoof Underlayments are follows:
TABLE 1: ROOF COVER OPTIONS
Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes Slate or
Shingles &Shingles Simulated Slate
RhinoRoof U20 Yes No No Yes Yes No
5.6 Exposure Limitations:
5.6.1 RhinoRoof Underlayment shall not be left exposed for longer than 30-days after installation.
6. INSTALLATION:
6.1 RhinoRoof Underlayments shall be installed in accordance with Interwrap, Inc. published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Install RhinoRoof Underlayments in compliance with manufacturer's published installation instructions and the
requirements for ASTM D226, Type I or II or D4869, Type II underlayments in FBC Sections 1507 for the type of
prepared roof covering to be installed.
Exterior Research and Design,LLC. Evaluation Report 140510.02.12-112
Certificate of Authorization#9503 FL15216-R2
Revision 2:04/27/2015
Page 2 of 3
TRINITY ERD
6.3 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application.
6.4 RhinoRoof U20:
6.4.1 Fasteners:
For exposure < 24 hours, corrosion resistant fasteners may be 1-inch roofing nails with a 3/8-inch diameter head, or
those noted in 6.4.2. The use of staples is prohibited.
For exposure > 24 hours up to maximum 30 days, corrosion resistant fasteners shall be minimum 1-inch diameter
plastic or metal cap nails or FBC HVHZ nails & 1-5/8" diameter tin caps (with the rough edge facing up). The use of
staples is prohibited.
6.4.2 Single Layer;Roof Slope>4:12:
End(vertical) laps shall be minimum 6-inches and side(horizontal) laps shall be minimum 4-inches. Refer to Interwrap,
Inc.recommendations for alternate lap configurations and/or the use of sealant under certain conditions.
For exposure<24 hours, use of every-other fastening location printed on the surface is acceptable. For exposure>24
hours up to maximum 30-days,use of every fastening location printed on the surface is required.
When batten systems are to be installed atop the underlayment,the underlayment need only be preliminarily attached
pending attachment of the battens on the same day. Battens shall not be positioned over cap nails. If this occurs,
remove the cap nail and patch the hole in accordance with Interwrap published instructions.
6.4.3 Double Layer;2:12<Roof Slope<4:12:
End(vertical)laps shall be minimum 12-inches and side(horizontal)laps shall be minimum half-sheet-width plus 1-inch.
Double layer application; begin by fastening a half-width plus 1-inch starter strip along the eaves. Place a full-width
sheet over the starter, completely overlapping the starter course. Continue as noted in 6.5, but maintaining minimum
half-width plus 1-inch side(horizontal)laps,resulting in a double-layer application.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
Intertek Testing Services NA Inc.-ETL/Warnock Hersey—QUA1673;(604)520-3321
-END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report 140510.02.12-112
Certificate of Authorization#9503 FL15216-R2
Revision 2:04/27/2015