HomeMy WebLinkAboutwindow design pressure Building height Zone 4 I Area 15 20 25 30 35 40 45 50 55 60 10 pos 37.9 40.4 42.3 43.8 45.4 46.7 47.9 48.9 49.8 50.7 neg 41.1 43.8 45.9 47.5 49.2 50.6 52 53 54 55 20 pos 36.3 38.7 40.5 42 43.5 44.7 45.9 46.8 47.7 48.6 neg 39.4 42 44 45.6 47.2 48.5 49.8 50.8 51.8 52.8 50 pos 35.4 37.7 39.4 40.9 42.4 43.5 . 44.7 45.6 46.5 47.3 neg 37.1 39.6 41.4 42.9 44.5 45.7 46.9 47.8 48.7 49.7 \100 pas 32.2 34.4 36 37.3 38.6 39.7 40.8 41.6 42.4 43.2 neg 35.4 37.8 39.5 41 42.5 43.6 44.8 45.7 46.6 47.4 500 pas 28.2 30.1 31.5 32.7 33.8 34.8 35.7 36.4 37.1 37.8 neg 31.4 33.5 35.1 36.4 37.7 38.7 40.5 39.7 41.3 42.1 Building height End zone 5 15 20 25 30 35 40 45 50 55 60 10 pas. 37.9 40.4 42.3 43.8 45.4 46.7 47.9 48.9 49.8 50.7 neg 50.7 54.1 56.6 58.7 60.8 62.5 64.2 65.4 66.7 67.9 20 pos 36.3 38.7 40.5 42 43.5 44.7 45.9 46.8 47.7 48.6 neg 47.3 50.5 52.8 54.8 56.7 58.3 59.8 61 62.2 63.4 50 pos 35.4 37.7 I 39.4 40.9 42.4 43.5 44.7 45.6 46.5 47.3 neg 42.8 45.6 47.7 49.5 51.2 52.7 54.1 55.1 56.2 57.3 100 pos 32.2 34.4 36 37.3 38.6 39.7 40.8 41.6 42.4 43.2 neg 39.4 42 44 45.6 47.2 48.5 49.8 50.8 51.8 52.8 500 pos 28.2 30.1 31.5 32.7 33.8 34.8 35.7 36.4 37.1 37.8 neg 31.4 33.5 35.1 36.4 37.7 38.7 39.7 40.5 41.3 I 42.1 Wind design Pressure Chart for structures subject to Florida Residential Code 170 mph exposure C Wall component and Cladding pressures from Table R302.2(2) modified by adjustment factors from R301.1(3). Converted to Vasd according to R302.1.2.1.1 POLO 9554 AVENEL LANE PORT ST LUCIE