Property Information Building Information
Owner: Jonathan Sharpe Wind Zone: i 170 MPH.
Address: 1203 Fleetwood Lane Exposure Category: C
Fort Pierce,F134982 Minimum Building Dimension: 46 ft.
Mean Roof Height: 12 ft.
Risk Category: 11
Roti
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) IF Pressure(psf)
1 Int 36 50 7 37.2 -40.5
2 Int 52 62 7 I 35.8 -39.0
3 Int 74 80 7 j 34.3 -37.5
4 Int 74 80 7 34.3 -37.5
5 Int 74 80 7. ... _...._. ._......._, 34.3 -37.5
6 Int 30 80 7 36.5 -39.7`-
I
,I
li
i.
i'
I'
i
• ji
i
I
Prepared in accordance with:ASCE 7-l0.Chapter 30. Wind Loads-Components and Cladding.5th Edition)(201 a)Florida Building Code.
Page 1 of 1
I,
i
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
SIZE REQ Y/N/NA
NUMBER or Interior OR DOOR TYPE NUMBER (+)PSF (-)PSF (+)PSF (-)PSF TESTED DIMENSIONS MULLION REQ Y/N
1 Int W 7/8°LamilG 150618.02 55 55 0.0 0.0 53X77 36x50 N N
2 Int W 7/8°LamilG 150618.02 55 55 0.0 0.0 53X77 52x62 N N
3 Int D I"Lami IG F115210.6 75/50 75/50 34.3 37.5 765k 115x02 74x80 N N
4 Int D PLamiIG F115210.6 75/50 75/50 34.3 37.5 76
Sg115'82 74x80 N N
5 Int D PLa1niIG F115210.6 75/50 75/50 34.3 37.5 76M115xK2 74x80 N N
6 Int D P Lami IG F115210.4 75 75 36.5 39.75 37.5x82 30x80 N N