Loading...
HomeMy WebLinkAboutProduct Approval N-1{s-`r!'^ Mpp- `"� tvZr- pasrt �s # .e"v.�a.,:±1'iFat SCIS Home ! Log In i User Registration Hot Topics ! Submit Surcharge i Stats&Fads j Publlaitions FSC Staff 6CI5 Site Map Links F? Search Busines ,) 4USER:Professi ll I PPub Approval Publi[User Regulation Prndud Anoroval Menu>Product or Annliration Searrh>Anolicatinn f I>Application Detail Nat�+� r FL$ FL10674-1112 o:r3P +1. �..rc$W, Application Type Revision Code Version 2014 Application Status Approved "Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway _n� { tai F Toledo, OH 43659 7 (740)404-7829 ti! r;[ - '' rm' greg.keeler@owenscorning.com Authorized Signature Greg Keeler JUL 14, greg.keeler@owenscorning.com PER?ki7177i'1IC St. Lucie County, FL Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M. Nieminen the Evaluation Report Florida License PE-59166 Quality ASSurance.Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W. Knezevich, PE I Validation Checklist- Hardcopy Received Certificate of Independence FL10674 R12 COT 2016 01 COl Nierninen.pslf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/18/2016 Date Validated 04/19/2016 Date Pending FBC Approval 04/20/2016 Date Approved 06/08/2016 SurnmarV of Products FL# Model,Number or Name Description i 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab, 5-tab, laminated, starter and hip&ridge i Shingles and Starters shingles Limits of Use _ M^ 4— Installation Instructions Approved for use in HVHZ:No EL10674 R12 Ii 2016 04 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R12.pddf Impact Resistant:N/A Verified By: Robert J. M. Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other:Refer to ER, Section S. Evaluation Reports FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT Created by Independent Third Party: Yes I+ rsar.• t�r�yt Con to U :: 1940 North Monroe Street,Tallahassee FL 32399 Phone:850.487.1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida. ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records,If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.instead,contact the office by phone or by traditional mail.11 you have any questions,please contact 850.487.1395. 'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012„licensees licensed under Chapter 455,F.S.must provide the Department with an emdil address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record,if you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: PW1® iChecl wrtifitvm t:rh icy EXTERIOR RESEARCH St DESIGN,LLC. Certificate of Authorization#9503 353 CHRISTIAN STREET,UNIT#13 TRINITY ERD OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R7 One Owens Corning Parkway FI-10674-1112 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 7: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5"' Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by. '7 S 'OF . i' The facsimile seal appearing wax authorized by Robert Nieminen, 1 ....... . Robert J.M.Nieminen,P.E. 4. P.E.on 04/1912016,This does not serve as all electionicallY Sig"Ki Florida Registration No.59166,Florida DCA ANE1983 document.Signed,sealed haudcopies have been ttansmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityIERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity]ERDis not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E.are,in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. � �~� �Q� TRINITY U U ��^�~ ROOFING SvSTcx4sEVALUoT|ON: %' SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,asproduced byOwens Corning, have demonstrated compliance with the following sections of the Florida Building [ode and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance issubject to the Installation Requirements and Limitations/Conditions ofUse set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM o3462 2009 z507.2J.1'n90s.2.6.1 Wind Resistance ASTM D3161 zous 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM u71sn zVox 3, Rspememcss: Entity Examination Reference Date uLLLC(cEny6a6) Physicals mWind Resistance File Ro4s3'Vol.» 02/15/2007 uLLLC(ctna5zo) Physicals&Wind Resistance 70120516'112453 05/16/2012 UL LLC(TSTyGro) Physical Properties 06cA202e3 04/18/2006 UL LLC(Tsr9628) Wind Resistance ztCA34388 02/18/2012 uLLLC(TST96zo) Physicals&Wind Resistance 4786093137 02/01/2014 oLLLC(TST96zo) Wind Resistance 4786126532 02/10/2014 UL LLC(T6Te528) Physical Properties Classification letter . 02/13/2814 UL Luc(T5Ty6ao) Physical Properties Classification letter 10/02/2015 miomi'oade(ccnzs92) ;aCxvnzCompliance va,iousmoxs Various uLLLC (0Ux9oz5) Quality Control Service Confirmation,R245s [wp.08/I[y2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic'and Supreme*are fiberglass reinforced,3-tab asphalt roof shingles. 4.12 Berkshire*are fiberglass reinforced,4-tebasphalt roof shingles. 4.1.3 Devonshin*`°are fiberglass reinforced,S-tabasphalt roof shingles. 4.1.4 Uuratiun^, TruDeGnibon~ Duration', Duration' Premium Cool, TruDefinition^ Duration* Designer [n|nr Collection, Tru Definition'Oakh6gc~' Oakridge. and VVeathcrGuar6^ HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire' Hip & Ridge Shingles, High Ridgp,VVeatherGuurd~ HP Hip & Ridge Shingles, PnoEdge Hip Q Ridge Shingles and DuraRidge`°Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. Dxo+TnT|mmS: 5.1 This is a building code evaluation. NebherThnhy\ERQ nor Robert Niemimen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose, 5.2 This Evaluation Report isnot for use inthe HVHZ. 5.3 Fire Classification isnot part ofthis Evaluation Report;refer tocurrent Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report o3m*u.o2.zz'xr Certificate"/Authorization v95m punen«'no Revision r'wV1m/zn1a Page zo*u TRINITY,ERD 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasa=150 mph (Volt= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles,Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2,6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to Vaad=150 mph (V,,,t= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3, 6. INSTALLATION: 661 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6_2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: :' Berkshire*shingles require minimum five(5)nails per shingle. ➢ WeatherGuard*HP shingles require minimum six(6)nails per shingle. Devonshire'""shingles require minimum six(6)nails per shingle. Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt underlayment Deck Felt undedayment —Deck St f•edhared -�•y SelGadhered WeathertockJP WeatherLock° . underlayment underlayment D 'r Ddpeega D" iY1 Diipedge Drip. edge j;1 edge �Cr Nails located Naih located 2=3"hum eave 2'-3'tmm rave Install first Self-sealing adhesive SeHbea;rg adhesive Starter Strip positioned along eave withInste6're oved Strip Pkn positioned along eave shingle with '•.., � with 6'removed --,- \ •/ V removed Stoner Strip shingle overhangs eaves and rakes 14'-L'." Stan&Snip Pkis overhangs uvas and ekes 114'-314' Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 F1.10674-1112 Revision 7:04/18/2016 Page 3 of 8 `i TRINITY'ERD 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard or Area pare Normal Mansard or Artie pare Wind Areas High Wind desvenea y Wind Areas High Wind desvenea y Area pare vientos normalas Areas vitiates feterres Area para Wonros normoles Areae viontoa fuertas ��tt• fA! tt.r r z- {8 r2' r t" (A) tzt r t� z•7 (B) r'z' t`� . . l-_ 5"Fitposura 65/8`Exposure Expositidn Exposicidn 6.2.7 Minimum Nailing—Berkshire®: Saa{am CNp Sealant strip La tiro de u4tWer is lira de sellador jr•-- � i• vt" ai a�—8 Y�Y' •f `t 6 lh' •g r�,� • s 8 rhe. s S 4Y• • . r r r Standard Fastening Pattern 6-Nail Fastening Pattern Seabtnt svip La lira da sellador ��--:rr a r e a a---+a s--i• r s yr s vt s yt s vt t 2" \ Asphahrmling cownt Cam tato da terho do astaku Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7 Certijhate oJAuthorization 119503 FL10674-R32 Revision 7:04/18/2016 Page 4 of 8 ` � TRINITY''—^»���|� 6.2.8 Minimum Nailing—Devunshire=: ell Nails 9/8'exposure Sealant location Ten V Spots of Asphalt Roof Cement Standard 6'wni|Fastening Pattern Mansard vrSteep Slope Fastening rnoem 6.2.9 Minimum Nailing—Dumtbnw,TruDefn|don" Duration, DurationOPremium Cool &TruDefiniUon^ Duration ^ Designer Color Collection: 4-Nall Fastening Pattern 6-Nall Fastening Pattern 771 rW j- Standard Fastening Patteo'maxFastening Pattern Fastening for 31opes Greater Than 21:12 -rz� Mansard v,Steep Slope Fastening Pattern Exterior Research and Design,uc. Evaluation Report o37940uz.o'm Certificate*^mhoriz",ionx95m pu0674-n12 Revision/.o*/zo/zozu Page smu t ` " IJ TRINITY$ERD 6.2.1 Minimum Nailing—TruDefinition'Oakridge',Oakridge°: 4 Nail Pattorn 6 Nail Pattorn Esquan2 can d tlavas Esquama cots 6 clavos V 1 Ir F/I 1��V -11 UZI' 5518"Eltposuro NaAs 5 5/8"Exposure IJalis FxpWd6nde6F1*puI9• Clavas Exposf an do5618pu1g. 65"8"Exposum 5Sir Exposure Evpo4d6rt de 6W palg. Exposicida de 6618 pulp. Standard Fastening Pattern 6-Nall Fastening Pattern Fastening for Slopes Greater Than 21:12 sw *.wkm+ klii TyplFp[ R, ..fa wY.uiS+.v� M U_«•.^i«�..•}w..»w,w-J,;� -«-2�..._k:�":^_6� F !r Pwt t•Spda f}t bptWt Roofing Calrnl Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuardO HP: ;inpl�1iCtd*VMw � '� :y�:% •:;:;• Fskesar7hrew�t t,>riil tis Cbt�as to ire ri 9�aci6or Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7 Certlflcote of Authorization 119503 FL10674-R12 Revision 7:04/18/2016 Page 6 of 8 . ^ \] � TRINITY,����^�� 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire'Hip and Ridge Shingles, High Ridge, VVeothe,Guand' HP Hip and Ridge Shingles and PnoEdAeHip&Ridge Shingles shall comply with the manufacturer's current published instructions,using four (4) nails per shingle, Installation ofDueRidQe= Hip& Ridge Shingles shall comply with the manufacturer's current published instructions, using two (Z) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.12 Fasteners shall he in accordance with the manufacturer's published requirements, but not less than F8C 1507.2.6orR905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berksh|re«Hip QRidge and High Ridge: Macon Nags Ndlv sn 63.4 Minimum Nailing—VveuthepGuand"HPHip and Ridge: Fig-A Fig.C Hip&Ridge Shingle Fastening TopVbw Rails flails T. ef IT Exterior Research and Design,LLC. Evaluation Report osro*ooz.12-m Cerdftotc w».tho*=mon,s03 Fu0674-1112 Revision 7:04/18/2016 Page rv/m ERD � _ TRINITYI .. M i 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard Wind Direction Sealant Strip � Fastening .� Pattern Aj••'� 6'Exposure ty i Sealant Fasten 7°h7'h S-Exposure Cover Exposed Fastanan with ! Root Camarn `„-t2• 6.3.6 Minimum Nailing—DuraRidgeT"Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. a_PraniMg Wird Diroedan ToMow Direaiondomitnntaduvont !- Y"":Friar Cla Diroctkn do(rintn prudarniranta 1 —T H < zjr ' fOMsatsCotritttipSuttNatr -:;�_ Ch,e t a a i i j o!a$ 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul,com - END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7 GertlJhote of Authorhatton#9503 FL10674-1112 Revision 7:04/18/2016 Page 8 of 8