FL# FL9777-R7 a 1
Application Type Revision JULg
Code Version 2014 U14
Application Status Approved
PERriArT;true
Comments st. Lucie County, i-1
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden
Validation Checklist-Hardcopy Received
Certificate of Independence FL9777 RZ RPS W 1P Hoc
Non-11VH7_ - final ndf
Referenced Standard and Year(of Standard) Standard Year
ASTM D 1970 2009
ASTM G 155 2005
TAS 103 1995
UL 1897 2004
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/19/2016
Date Validated 04/20/2016
Date Pending FBC Approval 04/21/2016
Date Approved 06/08/2016
Summary of Products
FL# Model,Number or Name Description
9777.1 Weatherlock G Weatherproofing Underlayment
Limits of Use Installation Instructions #
Approved for use in HVHZ:No FL9777 R7 U OCR14002.4A FBC 2014 Evaluation Repgoq #!
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party: Yes 1
Other:See evaluation report for limits of use. Evaluation Reports E
FL9777 R7 AE OCR14002.4A FBC 2074 Evaluation Re or
Weatherlock Non-HVHZ- final odf I
Created by Independent Third Party: Yes I
9777.2 Weatherlock MAT - — Waterproofing Underlayment
..-.--....._.......w_ _- _. _._.............
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9777 R7 Il OCR14Rei
)ort
FBC 2014 Fvaluation Rpnrr
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ final.ndf 1
Impact Resistant:N/A Verified By: Zachary R. Priest 74021 j
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R7 AE OCR14002.4A FBC 2014 Evaluation Report f
Weatherlock Non-HVHZ-final.odf
Created by Independent Third Party: Yes
9777.3 Weatherlock Metal _ Weatherproofing Underlayment
Limits of Use - �- Installation Instructions
Approved for use in HVHZ: No FL9777 R7 It O R1 0 2.4A FBC 2014 Evaluation Report
Approved for use outside HVHZ:Yes Weatherlock Non HVHZ- final.pdf
Impact Resistant:N/A Verified By: Zachary R..Priest PE-74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
V FL9777 R7 AE OCR14002-4A FRC 2014 Evaluation Report
,>itatherlock Non-HVHZ-final.pdf
Created by Independent Third Party: Yes
9777.4 Weatherlock Metal Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL9777 R7 11 OCR14 1f17 4 FB 7014 Evaluation gepQrs
Approved for use outside HVHZ: No Weatherlock Metal HVH -final
Impact Resistant:N/A Verified By: Zachary R. Priest PE-74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R7 AE OCR14002AB FBC 2014 Evaluation Report i
Weatherlock Metal HVHZ -final.pdf
Created by Independent Third Party: Yes
9777.5 �T Weatherlock Specialty Tile&Metal Weatherproofing Underlayment
Limits of Use 'Installation Instructions
Approved for use in HVHZ: No FL9777 R7 if OCR14002.4A FBC 7014 EvaluoLipn RQP-0r1
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ - finaLndf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021 1
Design Pressure: +0/-105 Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. i Evaluation Reports
FL9777 R7 AF OCR1Q942.4A FBC 2014 Evaluation Renin,
Weatherlock Non-HVH7-final.pd
Created by Independent Third Party: Yes
C
Contact[Is:: 1940 North Monroe Street Tallal twee FL 3'399 Phnnr:850-487-1824
The State of Florida is an AA/EEO employer.CooyrAht 2007-2013 State of Florida ::Privacy statement;; Accessibility Statement:: Ryiiind Statement
,
Certificate of Authorization No. 29824
CREEK
17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE 5�"EDITION (2014)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued April 99, 2096
1 Owens Corning Parkway
Toledo,OH 43657
(800)438-7465
www.owenscorning.com
Manufacturing Location: Brentwood,NH
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1504.3.1,1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5, 1507.4.5.2, 1507.5.3,
1507.5.3.2, 1507.7.3, 1507.7.3.2
Properties: Physical properties
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST6049) NEI-039-02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) NEI-042-02-01 REV2 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) NEI-045-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST6049) NEI-045-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST6049) NEI-053-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST6049) NEI-053-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST6049) NEI-093-02-02 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) OCF-213-02-01 ASTM D 1623 2009
PRI Construction Materials Technologies(TST6049) OCF-237-02-01 UL 1897 2004
PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 4798 2001
PRI Construction Materials Technologies(TST6049) OCF-252-02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST5878) OCF-253-02-02 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) OCF-272-02-01 TAS 103 1995
PRODUCT DESCRIPTION AND LIMITS OF USE
WeatherLock@ G WeatherLock@ G is an ASTM D 1970 self-adhesive underlayment constructed from SBS
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq.rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock@ G is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
WeatherLock@ Mat WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
sq,rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLock@ Mat is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
OCR14002.4A FL9777-R7 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
�=~0����N��0�~ oWEmyCORNING ROOFING AND ASPHALT LLC
��^0��0�*0�~��� meumo,Lvcm0Self-Sealing Ice&Water Barriers
TEoew|c/\L SERVICES, LLC
WeatherLncW0WYmtal VVoothorLonN0Metal is an ASTM D 1970 no|f-edhnoke undor|nymo^tconstructed from
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product iusupplied|n2.Osq.rolls with nominal dimensions nf3-ftxGG.7'M.
VVmatharLock@ Metal is permitted to be used with mechanically fastened asphalt
sh|ng|su, metal roof panels or shingles, wood shakes or shingles, and m|otm roofing as
prescribed in the FBC. Exposure on the roof deck shall be limited to o maximum QO
days.
WeatherLook@ VVau\harLooW@Specialty Tile & Metal isonASTM D 1970 self-adhesive umdadoymen
Specialty Tile&Metal constructed from SBS modified asphalt and surfaced with a non-woven polyester fabric.
The product issupplied in 2.14sq.rolls with nominal dimensions of3'ftx71.34t
YV*a1horLouN@ Specialty Tile&Metal|apermitted tmbeused with mechanically fastened
asphalt hi 0|wo. clay orconcrete U\o, metal roof panels or shingles, wood shakes or
shingles, and slate roofing as prescribed in the �BC' VVea�arLooW0Specialty Tile &
k4eta|iopermi�edtobnused v�dhadhered c�yo,nonomoetile roofing using i 3K8'~
2-Component Fomm Roof Tile Adhesive AH-180 (3M Company) or TILE BOND TM Roof
Tile Adhesive(The Dow Chemical Cnmpeny). Exposure onthe roof deck shall belimited
hnamaximum OUdays.
The maximum roof slope shall boG12when used with clay orconcrete tile installations
without battens. Tile shall be stored on battens for roof slopes greater than 0:12. Tiles
shall not bestacked greater 18tiles per stack.
PRODUCT APpucAnom
Min. Roof Slope: 2:12cxinaccordance|nwith FBC
Application: Deck substrates shag be clean, dry, and free and debris. AV
fasteners in the deck shall bchecked for protrusion and corrected prior tounderlayment
application. Prior to beginning inxhallatiom, the undedaynn*ntshag bo unrolled and
allowed to relax for aminimum of3'5minutes. '
The undedayment shall be installed with the release backer removed and pressed firmly
into place bzensure complete uontmc\wiUhthodeck. ThaundodoymmntnhaUba\no\o||ed
with the nn|| length parallel to the oave, starting at the oave, and with minimum 3^side
|opu and minimum 8^ end laps staggered 6-ft. from preceding course. End laps for
VVeathevLooW@Specialty Tile& Metal shall beprimed with ASTM D41 primer orsealed
with asphalt roof cement mminimum uf3-4inches across the width ofthe lap.
It is permissible tnnail the undedayment 18-inrhoaon-center oaneeded (nails shall be
installed perpendicular to dock with the nail heads flush to the bop surface of the
underlaymont). VVoaUhorLooN@ Specialty Tile & Metal oho|| be book nailed when
installed onroof slopes greater than 3:12.
For valley applications, the m|| shall be applied centered along the valley prior N
installing the underlayment at the aawa. Foroova pmtedion, the undadaymen( should
extend ioapoint Z4-nchosinside the exterior wall.
The undedayment shall be installed over metal drip edge at the eave,and under the drip
edge at the rake or valley pan when used as a valley liner. Alternately, it is permissible
to install the underlayment under the drip edge in accordance Section 1507.2.9.3.
Min.Application 4O`F: Contact the manufacturer when installing a/temperatures below the minimum
Temperature: application temperature.
oun1*0021x rL9777-g7 Page 2or4
`
��~0��N�~0��0�� OVYENSCORNING ROOFING AND ASPHALT LLC
���������� WeatherLock@ SelFSealingvee&Water Barriers
TECHNICAL SERVICES, LLC
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a2:1 margin ofsafety per FBCSection 15O4.A.
Underlayment System No.1
Roof Deck: Min. 15C32'inchCDXplywood attached(uwood supports spaced amaximum 24''o.c.
Underlaymen1: VVea*herLocW@ Specialty Tile & Metal shall be applied in accordance with
manufacturers installation instructions hothe fastened deck and bunknai!ad along the
selvage with minimum 12ga., 1'1/4'inoh galvanized ring shank roofing nails through
optionally pnmoo( 32Da. w 1-5/8'inch 0 tin caps spaced 1Z' u.c. The applied
underlayment shall be rolled with a minimum 751b snaa| roller immediately following
application.
Maximum Design -105puf
Pressure:
GENERAL L|xx|7AT|OmS
1 This evaluation report imnot use inthe HVHZ.
2) Fire Classification isnot within the scope ofthis evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published
application instructions, Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4> The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be property ventilated in accordance with the FBC requirements.
D) All side lap seams shall bninstalled hushed water from the deck.
7) The und d tmoybaueadoedeaohbedinotbercune,*F8Cproduct approvaldocuman\o.
8> Design wind load pressures shall be determined for components and cladding in accordance with F8C
1609.
S) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Fr*nomao for a given undadaymen\ shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
of
CREEK
OWENS CORNING ROOFING AND ASPHALT LLC
`R Weatherl-ock@ Seif-Sealing Ice&Water Barriers
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code Vh Edition(2014)as evidenced in the referenced documents submitted by the named manufacturer.
tIA 11 l<I t t 11111r�i
R. P�, 2016.04. 19
N
••; = 15:51 :11
No 74021
-04'00'
3 STATE OF :�41Jh
•• Al Zachary R. Priest,P.E.
Florida Registration No.74021
��,��►ONp�i tE���� Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E.does not have,nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR14002.4A FL9777-R7 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.