HomeMy WebLinkAboutProduct Approval (2) FILE C07"'
JUL 14 20116
MIAMI- MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami.Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-25'90 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.iniaiiiitiiide.",t)%-Iecoiii)iiIN-
GAF
I Campus Drive
Parsippany,NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
tp
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
includin-the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION-.'-GAF—�Uniber-lin—e-H-07""',,Timberline Natural ShadoW%and Timberline American Harvese
Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product. 0
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shat I be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA 13-0419.04 and consists of pages I through 6.
The submitted documentation was reviewed by Juan E. Collao, R.A.
MIAMI-DADE COUNTYNOA No.: 14-1022.20
Expiration Date:02/21/17
Approval Date: 02/05/15
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
SCOPE
This approves GAF Timberline HD`s,Timberline Natural Shadow',and Timberline American Harvest'
Shingles as manufactured by GAF as described in Section 2 of this Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
G�A'F-ZTiiiiri eAne:IiDf 13 '/4"x 39;/g, TAS 110 Fiberglass reinforced heavy weight asphalt
Manufacturing roof shingle,with a laminate profile
Locations#1,2,3,4,5,6,7
GAF Timberline Natural 13 '14"Y 39 3/$' TAS 110 Fiberglass reinforced heavy weight asphalt
Shadow`o roof shingle,with a laminate profile
Manufacturing
Locations#1,2,3,4,5,6,7
GAF Timberline American 13 '/a"x 393/8" TAS 110 Fiberglass reinforced heavy weight asphalt
Harvest' roof shingle,with a laminate profile
Manufacturing
LOCal iO17S#2,4,5,6
MANUFACTURING LOCATION
1. Tampa,FL
2. Michigan City, IN
3. Baltimore, MD
4. Myerstown,PA
5. Ennis,TX
6. Tuscaloosa, AL
7. Dallas,TX
MIAMI•DADE CNOA No.: 14-1022.20
�qmOUNTY
••, , Expiration Date:02/21/17
Approval Date: 02/05/15
Page 2 of 6
rl
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
Underwriters Laboratories,Inc. ASTM D3462 I 1 CA48924 10/24/11
Underwriters Laboratories,Inc ASTM D3462 1 OCA21994 04/22/11
Underwriters Laboratories,Inc ASTM D3462 1 OCA28717 07/26/11
Underwriters Laboratories, Inc. ASTM D3462 05CA47541 11/10/06
Underwriters Laboratories,Inc. ASTM D3462 06CA31580 11./30/06
PRI Asphalt Technologies, Inc. ASTM D3462 GAF-101-02-02 11/02/05
Underwriters Laboratories, Inc. ASTM D3462 06NK05159 08/09/06
PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05
Underwriters Laboratories, Inc. ASTM D3462 02NK41809 08/11/02
Underwriters Laboratories, Inc. ASTM D3462 03NK26444 10/17/03
Center for Applied Engineering ASTM D3462 257989 05/13/97
Underwriters Laboratories, Inc. TAS 107 OINK45803 04/13/94
Underwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06
Underwriters Laboratories, Inc. TAS 107 04NK04273 02/20/04
Underwriters Laboratories, Inc. TAS 107 05CA42840 11/11/05
Underwriters Laboratories,Inc. TAS 107 02NK4181 1 11/11/02
Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/03
Underwriters Laboratories, Inc. TAS 107 04CA13850 08/30/04
Center for Applied Engineering TAS 100 257989 04/01/97
PRI Asphalt Technologies, Inc. TAS 100 GAF-044-02-01 01/13/04
PRI Asphalt Technologies, Inc. TAS 100 GAF-098-02-01 11/08/05
PRI Asphalt Technologies, Inc. TAS 100 GAF-101-02-01 11/09/05
PRI Asphalt Technologies, Inc. TAS 100 GAF-1 16-02-02 03/23/06
PRT Asphalt Technologies, Inc. TAS-100 ELK-083-02-01 10/16/02
ELK-084-02-01 10/]S/02
ELK-085-02-01 10/14/02
ELK-086-02-01 10/24/02
ELK-087-02-01 10/21/02
ELK-088-02-01 10/16/02
ELK-107-02-01 10/09/03
ELK-108-02-01 10/09/03
ELK-]09-02-01 10/09/03
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 14-1022.20
MIAMI DADE COUNTY
•• . Expiration Date: 02/21/17
Approval Date: 02/0.5/15
Page 3 of 6
i!
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail W, attached.
S. Nailing shall be in compliance with Detail'B', attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
County Product Control Seal as shown below.
MIAMI•DADE COUNTY
��vumlnqlj
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 14-1022.20
MIAMI•DADECOUNTY Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 4 of 6
DETAIL A
Comm,LAYOUT
DECK
FULL
5th
17" OFF 4th
11"OFF 3rd
------------
6" OFF 2nd
FULL 1st
NOA No.: 14-1022.20
WMIAMI-DADECOUNTY IS
�FIIVZPYVIJ� Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 5 of 6
DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
.00 39-3/8111
-0 14-1/2"-17-1/2" .0 14-1/2"-17-112" -
(368-445mm) (368-445mm) __
6-1/2"-9-1/2" 6-1/2"-9-1/2" /--Nail guide line
' (1
13-1/466-241m) —0-1 7 5-314"-6-114"
(337mrfi) 112'-2 71-2;- (146mm-159rnm)
(13- from bottom of shingle
elf seal
adhesive
on back
ENHANCED NAILING PATTERN - six nails per shingle*
required by some local codes and required for enhanced wind coverage on certain products.
See limited warranty for details,
These shingles MUST be nailed a nominal 6" (152mm)from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed.
END OF THIS ACCEPTANCE
NOA No.: 14-1022.20
MIAMI-DAD,COUNTY
Expiration Date: 02/21/17
Approval Date- 02/05/15