Loading...
HomeMy WebLinkAboutEngineering i N FUO A ENGINEERING & TESTING, INC. Phone: (866)781-6889•Fax: (866) 784-850 www.floridaenoineeringandtest'mg.com 250 S.W.13th Avenue Pompano Beach,FL 33069 ATE: 7/07/16 JOB ORDER#: 16-2103 CLIENT: All Area Roofing ADDRESS: 3921 S.US Highway 1 Fort Pierce,Florida 34982 i ROJECT: Utile Residence Flat Wood Non Insulated Roof Deck ADDRESS: 2610 Newport Drive Fort Pierce,Florida FBC 2014/ASCE 740 DESIGN PRESSURE CALCULATIONS Project Information: Height= Max. 15' Exposure: C Basic/Ultimate Wind Speed: Vult=170 mph Length= 32' Category: II Nominal Wind Speed: Vasa=Vu1t*-0.6 Width= 17' Slope: <7° (asd=allowable strength design) Parapet Wall: N/A Residential KZ=0.85, Kzt= 1.0, Kd=0.85 Design Calculations: (Velocity Pressure: q=0.00256*KZK�KdV2 Velocity Pressure (ult): q=0.00256(0.85)(1.0)(0.85)(170)2] =53.45 psf Velocity Pressure (asd): q=0.00256(0.85)(1.0)(0.85)(170*y6.6)2] =32.07 psf idth of Pressure Coefficient: 0.1(17') = 1.7' 0.4(15') = 6.0' ) use: 3'0" Effective Wind Area: <10ft2 or parapet height three feet(3') or larger, zone three(3) shall be treated as zone two (2). External Pressure Coefficient: Internal Pressure Coefficient: 1) GCP1 = -1.0 1) GCPi = 0.18 2) GCP2 = -1.8 3) GCP3 = -2.8 W Qrcality 1 y,✓Insurance Page 2,7/07/16,Job Order#16-2103 All Area Roofing-Utile Residence FILO 1� Flat Wood Non Insulated Roof Deck 2610 Newport Drive;Fort Pierce,Florida: Design Pressures Based on Vasa: . 1) Field P1 = 32.07*[(-1.0)—(0.18)] =-37.8 psf 2) Perimeter P2 = 32.07*[(-1.8)—(0.18)] =-63.5 psf 3) Corners P3 = 32.07*[(-2.8)—(0.18)] =-95.6 psf Attachment Requirements Per RAS-117: Based on the requirements of N.O.A. #14-0529.02,pg 23 of 42, System Type E(3),with a m�ximum design pressure of -52.5psf; the following are our recommended fastening patterns to attach the proposed base sheet to the wood (non-insulated) 19/32" or greater pl ood or wood plank deck utilizing approved 11 ga. annular ring shank nails and ap roved tin caps: Filld: 8" o.c. @ 4" laps and 3 staggered rows 8" o.c. Pelvimeter: 6." o.c. @ 4" laps.and 3 staggered rows 6" o.c. Comers: 6" o.c. @ 4" laps and 5 staggered rows 6" o.c. Notes: Corners and perimeter area dimension shall not be less than a=3'0" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty(as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2014 Edition. Wind load calculations based on ASCE 7-10, FBC 2014 and information provided by client. Client is responsible for verifying existing conditions as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sincerely.; Miri[A. Mesianb, P.E. Fl&-Li Engineering Tes ing, Inc. Floiida;R g.No. 482.02:- J Certihcate.of Author"-7-ation No. 6923