HomeMy WebLinkAboutBuilding Permit ApplicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: Permit Number:
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34981
Phone: (772)462-1553 Fax:(772)462-1578 Commercial Residential V
PERMIT APPLICATION FOR: Plumbing
LPROPOSED IMPROVEMENT LOCATION:
Address: 4200 N A1A APT 1010 - FORT PIERCE, FL 34949
Legal Description: OCEAN HARBOR SOUTH BLDG S UNIT 1010 AND UND INTEREST IN COMMON ELEMENTS (OR
Property Tax ID #: 1423-501-0170-000-2
Site Plan Name:
Project Name:
Setbacks Frant Back: Right Side:
Left Side:
Lot No.
Block No.
I DETAILED DESCRIPTION OF WORK: III
REPLACE EXISTING ELECTRIC WATER HEATER TANK INSIDE HALLWAY CLOSET WITHIN
CONDO UNDER A/C HANDLER WITH NEW AO SMITH ELEC 30 GAL WATER HEATER TANK.
I CONSTRUCTION INFORMATION: II
_ HVAC
❑
CONTRACTOR:
Gas Tank
PVF ilia—Niel. du apply :
E1Gas Piping Shutters
0 Windows/Doors
11 Electric
21
Plumbing❑Sprinklers
City: Port St Lucie State: FL
Zip Code: 34984 Fax: 772-871-9069
Phone No. 772-871-9494
E -Mail: n/a
❑Roof
E -Mail: Permits@benfranklinplumber.com
State or County License: CFC1426801
Generator
Total Sq. Ft of Construction:
SFt.
of First Floor:
Cost of Construction:$
1375.00
Utilities:Sewer
Septic
Building Height:
OWNER/LESSEE:
CONTRACTOR:
Name Conrad & Sharon DALLAND
Name: Robed W. LUDLUM
Address:4200 N Hwy A1A Apt 1010
Company: Benjamin Franklin Plumbing
City: Fort Pierce State: FL
Zip Code: 34949 Fax: Na
Phone No. 772-359-9027
Address: 1631 SW South Macedo Blvd
City: Port St Lucie State: FL
Zip Code: 34984 Fax: 772-871-9069
Phone No. 772-871-9494
E -Mail: n/a
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
E -Mail: Permits@benfranklinplumber.com
State or County License: CFC1426801
If value of construction is 52590 or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:.
FRONT
DESIGNER/ENGINEER:
Name:
Not Applicable
MORTGAGE COMPANY:
Name:
Not Applicable
Address:
MANGROVE
Address:
COUNTER
City:
Zip: Phone:
State:
City:
Zip: Phone:
State:
FEE SIMPLE TITLE HOLDER:
Name:
_Not Applicable
BONDING COMPANY:
Name:
_Not Applicable
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend to obtain financing, consult with lender or an attorney before
STATE OF FLORIDA STATE OF FLORIDA / ,
COUNTYOF L' {i_ COUNTY OF .S wCj
The forgoing instrument was acknowledged before me
this,Xdayof 20[(s_by
v+
(Na of person ac"ledging
e /
of
Commission No.
Revised 07/15/2014
The forgoing Instrument was acknowledged before me
this /_iday of 3 / 20-7by
(Name of PE
(Signatures
Personally K
Type of Ider
#FF1e5172I Commission No. �i^_-_.!• MYCOM t1&#F1,2018
or t, 2018
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEATURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
COMPLETE
INITIALS
Ce Smithe Residential Electric
Water Heaters
ENHANCED HEATING ELEMENTS
• Dual 4500 watt elements for fast recovery
and reliable operation."
CODE COMPLIANCE
• Meets UBC and ICC National Codes and
listed with CEC.
• incoloy stainless steel lower element lasts • Complies with the Federal Energy
longer than a standard copper element. Conservation Standards effective
DYNACLEAN' DIFFUSER DIP TUBE April 16, 2015, in accordance with the
Energy Policy and Conservation Act
• Helps reduce lime and sediment buildup (EPCA), as amended.
and maximizes hot water output. Made
from long-lasting PEX cross-linked
polymer.
HIGH ENERGY FACTORS
• Eco -friendly non -CFC foam insulation,
heat traps and other features combine
to yield a higher Energy Factor that
maximizes savings on operating costs.
COREGARD'" ANODE ROD
• Our anode rods have a stainless steel
core that extends the life of the anode
rod allowing superior tank protection far
longer than standard anode rods.
BLUE DIAMOND- GLASS COATING
• Provides superior corrosion resistance
compared to industry standard glass
lining.
ENHANCED -FLOW BRASS DRAIN VALVE
• Our residential water heaters have a solid
brass, tamper resistant, enhanced -flow,
ball type, drain valve.
• Uses a standard female hose fitting that
allows for fast and easy draining during
maintenance.
• Designed for easy operation, this valve
includes an integral screwdriver slot that
features a'/4 turn (open/close) radius,
which not only permits full straight -
through water flow but also a quick and
positive shut off.
'Model entad ha: a Birdie eiemem,
APPROVED FOR MANUFACTURED
HOUSING
• All residential electric water heaters are
compliant with HUD Standards for mobile
homeslmanufactured housing.
CERTIFIED TO UL 174 FOR HOUSEHOLD
ELECTRIC WATER HEATERS
CSA CERTIFIED AND ASME RATED TBP
RELIEF VALVE
DESIGN -LISTED BY UNDERWRITERS
LABORATORIES
• Certified at 300 psi test pressure and 150
psi working pressure.
• Listed according to UL 174 standards
governing storage tank -type electric water
heaters,
6 -YEAR LIMITED TANK AND PARTS
WARRANTY
• For complete information, consult written
warranty or go to hotwateccom.
®seamaq 306 a o. smith eorpoahm. At nghra reserved. ", i ,re
mw Imwatmcam 1800-527-1953 moll -Free USA I A.0. Smith CWmmton 1500 Tennessee M11, Parkway I AshImmi City, 11137015 AoSeE50602
(Cesmi t h
Residential Electric
Water Heaters
M del
Number
ballon
Capacity
flat Hom
Bating
Gallon
Energy
Factor
RecoVery�
90 F Rise
GaHou Per
Element Watta e 240
--0lmension4 in dries
Approx
Sh9PP (IVs
We ht )y
Standard Maxlmu A 0 C
Tall Models
ENTd01
ENLdS
51
0.95
1i
u0
60 '.14
53 4
It
18
ENTB-501 `
'.6
70
0.95
21
4500
6000
60-114
51-114
21
131
ENT -50
50
71
0.95
11
4500
6000
Fit
51-114
22
134
ENTSSi
76
0.94
2t
4500
6000
5648
48111
24
1.45
Short Models««-
••-.
,'
c x
..«.
EN50 30•
•...
9
30 2
ENS -301
3 4
14
ENS -40t
40
-
1.
IJ9
ENS 50t
50
I
b.
iPkawbo .To
' 0dels
u
ENL`20
19.5
NIA
N A
11
4500
6000 1
21-074 T
20
65
EN1.11-30'
28
1 40
1 0.95
1 11
4500
6000
30
21-314
21
96
ENLd01
1&
43
0.95
21
4500
60p0
31-114
11-314
24
115
ENLk40'
38
46
0.95
11
4500
6000
31-314
24
24
118
EN640t+
38
44
0.95
P
4500
6000
33-112
14
26
118
Elf , 0-
48
57
10.95
21
4500
1 6000 1
34 1
25 1
26-112
172
Met, 3R'watel mnnettianz an 8"c.,,
Madel, no vAb zupplad natal an blank¢,
the 10 year tank and&year pans vnnamy, thing -E- to'P-In the model number larrele'. EMd0 becomes PNT30).
+top T&P media far tradable on this model.
ENL -20, a single element configuration arty
Optional T&P lorarian Ylieusedden de EM -So, ENTB50, ENI -55, ENN0aM MI
Top T&P is not available an the 10 year model PNU& 50.
Dimensions and ipeafrourne eablea to Range without notice in accordance send aur paltry of amtinmr, Prado, imparement
T&P VALVE
ACCESS
PANEL
ACCESS
PANEL
DRAIN
VALVE
ANODE (OR OPTIONAL
T&P LOCATION 41)
T / d OPTIONALT&P
LOCATION #2
OO ° 0°
C JUNCTION
BOX
T&P VALVE
LFor technical information all 800-527-1953.A. QSmithCorporation reserves the tight to make product changes or Improvements 3Wthput prior notice.