HomeMy WebLinkAboutInspection Docs KHPE SERIES THERMOPL US° VERTICAL WATER SOURCE HEAT PUMP PROJECT: A/R mc. SIZE: 420V5713-6813 CONTACT: INPUT SENSIBLE EER JOB SCHEDULE TOTAL BTUH WATTS BTUH COP GPM EWT LWT EAT LAT COOLING 741,589 45,467 328,828 85'F 95°F 91/79°F 55.1/54.7 HEATING 737,243 52,170 4.02 136 70°F 63°F 42'F 115.4°F REHEAT 176,780 55.1 'F 73"F ELECTRICAL DATA BLOWER COMPRESSOR MIN.CKT. MAX.FUSE VOLTAGE PHASE/HZ HP FLA RLA LRA UNIT FLA I.AMPACITY 208 3/60 7.5 19.8 4 x 51.3 4 x 300 225 238 250 BLOWER PERFORMANCE COMMENTS: INSTALLED WEIGHT EXT.STATIC PRESS.I.W.G. 1.0 Face Area 25.3 LBS. 2850 CFM 8,768 FPM 350.0 KG. DIMENSIONS 66,E T 26 J VALL zµuCuai ret.mw FR01111E WALL CNWR SSE SSE SSS 6�COn� B aFP cl Hoar 41 a a wALL wAu TOP VIEW i 3 385/32 Typ 158H8 a 1rz 8 O —T 1315/32 ® 13 o (D SQ -�{ 121732SQ 13 8 6Q O 90 12 111 O E : IE El % 10 O O T= = O O LEFT VIEW 120 s RIGHT VIEW I FRONT VIEW 120 68 118 LEGEND 1-COMPRESSOR AND CONDENSER ACCESS DOORS 2-13LOWER MOTOR ACCESS DOOR 3SIGHT GLASS 4813 4.GONDENSER ACCESS DOORS FOR KAC MODEL CONDENSER TX VALVE ACCESS DOORS FOR KHP MODEL 5•BLOWER MOTOR AND TX VALVE ACCESS DOOR 6-ELECTRICAL ACCESS DOOR —UTDOOR HOOD 8-ELECTICAL POWER IN &LOW VOLTAGE IN O O 4Q 18-WATER IN 2112 FPT 11-WATER OUi 212 FPi 12-CONDENSATE DRAIN 1 12(ABS)CONNECTION 13-FILTER ACCESS DOOR FILTER SIZE (20"x 24"x 2') 10 SHIPPING 3050 WGT. i Air System Sizing Summary for[DQAS Project N2 me:,05046 JENSEN BEACH RESORT 07/14/2016 Pre aced b .TYEC 03:67PM Air System information Air System Name...___...-............._.--......-.._.—_..-_DORS Number of zones--- ....--•.----------...._---___...._...._.......1 Equipment Class...............__ _-.-.........__..PKGROOF Floor Area--- -- ...----... .__-__.._---------- ---8862.0 ft2 Air System Type............... _ ____....___._.__..SZCAV Location----•.---_--__-_---__—__.West Palm Beach,Florida Sizing Calculation information Calculation Months__..._._._..._...— __.. Jan to Dec Zone CFM Sizing_-...............Sum of space airflow rates Sizing Data...__.___ _. —__..._..,....._...__..__Calculated Space CFM Sizing___.__..__individual peak space loads Central Cooling Coil Sizing Data Total coif toad..__ .:. ..______..---.....................__'56.3 Tons Load odors at_. .._ _ .____.....___......__.._._Jun 1400 Total coilload.._......._....---_...----._�___--.--.•--•-_----.._.676.6 MBH OA DB 1 WB_____.........._...—_,.—_..-._.._._-_-----_.89.6177.9 IF Sensible coil load_---_...---..._-•--........... 319.6 MBH Entering DB/WB__....._.__._...._....__................._—.89.5177.8 OF Coil CFM at Jun 1400_._ __-_--........... - __8838 CFM Leaving DB I WB IF Max block CFM__.................._._. __..._•---------....-.-.-.:.----8839 CFM Coil ADP—......_...—....-•---.. _....---.._.—__,...._...__54 2 "F Sum of peak zone CFM._...--_......_....---....___...---__----8839 CFM Bypass Factor_---....----_....._._ ..............._._-�...__..0.050 Sensible heat ratio— _:___..---_...._,..---..__...-0.473 Resulting RH---__w__..__..._.___.....__....._..__•___—..5o % fts/Ton__- ....__..,..__..._._�....__.._..._....- ...167.4 iS7.4 Design supply temp._---..___...._ _68.9 IF 76.2 Zone Water flow} ._...-................_..__-•------------_._. 7 stat Check_... ....___.__._........._.. .___.,-.-1 of 1 OK BTU/r hr--ft2 @ 10.0 IF rise_----..•._.......__....�__NIA Max zone temperature deviation---__---- o.o IF i Central heating Coil Sizing Data Max coil load___-------..--__--.-•--_...............—_..__252.7 MBH Load occurs at----—----—_..---._._.._.--.....__.....___.___Des Htg Coil CFM at Des Htg.......___-........._...,...._.8839 CFM BTU/{hr-ft2}......_...........__ _—_—....... .------.,..__......_._28.5 Max Coil CFM...................................___-.__.._..—..-_-...8839_ CFM Ent.DB/Lvg DB.---............._.__.--_...................-_.-_43.2169.7 IF Water flow Q 20.0 IF drop_..._..................... —.._.......NIA Supply Fan ISizing Data Actual maxI'CFM----------- ----..-.,--.------.... . 8839 CFM Fan motor BHP.__---•--._.• _..__,.... _............._..--_-__-_9.68 BHP Standard GFM.__.,_._ __._—_—.__..............._._......._8832 CFM Fan motor kW-----------____.___..•---..•----.....--..._......__..__7.68 kW Actual maxICFM/f12 .........:....... .--------_..—...-.-........i.00 CFMw Fan static--...........................__..._._..........._.....-- -.......4.00 in wg Outdoor Vetctilation Air Data Design airflow CFM,,.,,........ .-----8766 CFM CFM/person ...................__......._-..._......_.__._....398.41 CFM/person CFM/ft2 ......................_..-__.--.-.0.99 CFM/ft2 I `�lltlliltfJ//// oto.33 ti' .ted-A.-w �0 16":6 \N Hourly Analysis Program v4,91 Page 1 of 6 i `b Psychrometric Analysis dor DOAS Project Name:05046 JENSEN BEACH RESORT 07/14/2016 Prepared :TYEC 03:57PM Location: West Palm Beach,.Florida Altitude: 20.0 ft. Data for: June DESIGN COOLING DAY, 1400 0.020 utd�o Air i et 11`0 niaoonl�o(`gu �e .......... .............................. ....... i t' - 0.018 ra �ea n �o1 u e o�nyi4ir / �; - _.....__ / ----....- - 0. 016 ---.........................._....._ ...-- ....... ........_ ............... -- � - -•--_.. ... 0.014 CD 0. ............. ................ ............. ................ -••-------....._......_.. .. ............ ---- ----........ ..--- 0.0 - ..........I--.......... ................ ---.._. --........ . -•---.... 12 0.0103 - ---.............................................-- ... ...... . ..... ........... ....i. .......... ......... 0.008, ........ ....................... . .....r. ...... ... .............. ..................-..... 0,006 ..--------- - 0.004 --------------- --0.002 0.000 30 40 50 60 70 80 90 100 Temperature ( °F ) Hourly Analysis Program v4.91 Page 6 of 6 System Psychrometrics for WAS [Prepared roject Name:05046 JENSEN BEACH RESORT 07/14/2016 by,NEC 03:57PM I WINTER DESIGN HEATING TABLE 1: SYSTEM DATA Dry-Bulb Specific Sensible Latent Temp Humidity Airflow CO2 Level Heat Heat Component) Location °F ibilb CFM m BTUthr BTUIhr Ventilation Air Inlet 43.0 0.00290 8765 400 -256750 0 Vent-Return' Mixing Outlet 43.2 0.00290 8839 400 - - Central Cooling Coil Outlet 432 0.00290 8839 400 . 0 0 Central Heating Coil Outlet 69.7 0.00290 8839 400 252687 Supply Fan Outlet 72.5 0.00290 8839 400 26209 Cold Supply.Duct Outlet 72.5 0.00290 8839 400 Zone Air 1 - 70.1 0.00290 8839 403 -22146 0 ,Return Plenum Outlet 70.1 0.00290 8839 403 0 Air Density it Heat Capacity x.Conversion Factor_At sea levet=1.080;At site altitude=1.079 BTU/(hr-CFM-N Air Density xi Heat of Vaporization x Conversion Factor At sea level=4746.6;At site altitude=4743.2 BTU/(hr-CFM) Site Altitude 20.0 ft TABLE 2: ZONE DATA i Zone Terminal Zone Sensible Zone Zone Zone CO2 Heating Heating Load T-stat Cond Temp Airflow Level Coil Unit Zone Name BTUIhr Mode BTUIhr °F CFM m BTUIhr BTUIhr Zone 1 -17828 Deadband -22146 70.1 8839 403 0 0 i I I I I I I Hourly Analysis Program v4.91 Page 5 of 6 s Systema Psychrometrics for DOAS Project Name:p5046 JENSEN BEACH RESORT 07/14/2016 Prepared b .TYEC 03:57PM E June DESIGN COOLING DAY 1400 TABLE 1: SYSTEM DATA Dry-Bulb Specific Sensible Latent Temp Humidity Airflow CO2 Level Heat Heat Component Location °F lbRb CFM m BTUtttr BTUfhr Ventilation Air Inlet 89.6 0.01795 8765 400 130583 351496 Vent Return Mixing Outlet 89.5 0.01788 8839 400 - - Central Cooling Coil Outlet 56.0 0.00938 8839 400 319574 356006 Central Heating Coil Outletj 67.6 0.00938 8839 400 110726 - Suppiy Fan' E Outlet 70.3 0.00938 8839 400 26209 Cold Supply Duct Outlet 70.3 0.00938 8839 400 - Zone Air 75.8 0.00949 8839 433 52056 4510 Retum Plerium Outlet 75.8 0.00949 8839 433 0 Air Density. Heat Capacity x Conversion Factor:At sea level=1.080;At site attitude,=1.079.BTUI(hr-CFM-F) Air Density z Heat of Vaporization x Conversion Factor.At sea level=4745.6;At site altitude=4743.2 STUI(hr-CFM) Site Attitude=20.0 ft TABLE 2: ZONE DATA I Zone Terminal Zone Sensible Zone Zone Zone CO2 Heating Heating Load T-stat Cond Temp Airflow Level Coil Unit Zone Name TUlhr Mode STU1hr 'F CFM m TU1hr BTU/hr Zone 50646 Cooling 52056 75.8 8839 433 0 0 i i I i I i I i i Hourly Analysis Program v4.91 Page 4 of 6 Air System Design Load Summary for WAS Project Name:05046 JENSEN BEACH RESORT 07/1412016 Prepared b :TYEC 03:57PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1400 HEATING DATA AT DES HTG COOLING OA DB 1 WB 89.6 OF 177.9 OF HEATING OA DB I WS 43.0 OF 136.1 OF Sensible Latent Sensible Latent ZONE LOADS Details (BTU/hr) (BTU/hr) Details (STU/hr) (BTU/hr) Window&Skylight Solar Loads 540 ft2 23599 - 540 ft2 - Wall Transmission 711 ft2 852 - 711 ft2 1952 - Roof Transmission 1062 f12 135.3 - 1062 ft2 1255 - Window Transmission 540 ft2 3883 - 540 ft2 8573 - Skylight Transmission 0 112 0 - 0 ft2 0 Door Loads; 0 ft2 0 - 0 ftp Floor Transmission 0 ft2 0 - 0 ft2 0 Partitions ' — — 4032 ft2 449 4032 ft2 . 6048 - Ceiling j 0 ft2 0 - 0 ft2 0 - Overhead Lighting 4431 W 15118 - 0 0 - Task Lighting 0 W 0 - 0 0 Electric Equipment 0 W 0 - 0 0 - People ! 22 5390 4510 0 0 0 Infiltration ! - 0 0 - 0 0 Miscellaneous - 0 0 -1 0 0 Safety Factor 0%10% 0 0 0% 0 0 Total Zone Loads 50646 4510 17828 0 Zone Conditioning - 52056 4510 - 22146 0 Plenum Wall Load 0% 0 - 0 0 - Pienum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 _ Return Fanload 8839 CFM 0 - 8839 CFM 0 - Ventilation Load 8765 CFM 130583 351496 8765 CFM 256750 0 Supply Fan,Load 8839 CFM 26209 - 8839 CFM -26209 Space Fan Coil Fans - 0 - 0 _ Duct Heat Gain/Loss 0% 0 - 0% 0 - »Total System Loads 208848 356006 252687 0 Central Co66ng Coil 319574 356006 - 0 0 Central Heating Coil - -110726 - - 252687 - »Total Conditioning - 208848 356006 - 252687 0 Key. Positive values are clg loads Positive values are htg loads Negative values are htg loads Negative values are clg loads I i Hourly Analysis Program v4.91 Page 3 of 6 Zone Sizing Summary for DORS IPP' roject Name:05046 JENSEN BEACH RESORT 07/14/2016 re aced b .TYECProject Air System Information Air System Name_----•-- --_-•-----_------DOAS Number of zones.-- --------------------------___------- A Equipment Class. ---_---- ___________PKG ROOF Floor Area------•---_----------...._----------____-.8862.0 ft' Air System Type___._______.._-___.____— SZCAV Location--�___—._— West Palm Beach,Florida Sizing Calculation Information Calculation Months-_._-_-_____—___...................:..Jan to Dec Zone CFM Sizing___--Sum of space airflow rates Sizing Data -._.-_...-._.__—_____._.__.._-._.-Calculated Space CFM Sizing___._.-__---.Individual peak space loads I Zone-Terminal Sizing Data i Reheat Zone Zone Design Minimum Reheat Coil Htg Unit Htg Unit Mixing Supply Supply Coil Water Coil Water Box Fan Airflow Airflow Zone Load gpm Load gpm Airflow Zone Name CFM CFM CFM1ft= MBH 20.0°F MBH 20.0-F CFM Zone 1 1 8839 8839 1.00 0.0 - 0.0 - 0 Zone Peak Sensible'Loads I Zone Zone Zone Cooling Time of Heating Floor Sensible Peak Sensible Load Area Zone Name (MBH) Cooling Load (MBH) (ft=) Zone 1 55.4 Jul 1600 17.8 8862.0 Space Loads and Airflows Time of Cooling Peak Air HeatingXArea Zone Name I, Sensible Sensible Flow LoadSpace Space Name Mutt. BH Load CFM MBHCFPAHF Zone 1 1ST FLOOR CORRIDOR 1 8.4 Jul 1600 1289 2.0 1.07 2-7 TH FLOOR CORRIDOR 6 6.9 Jul 1600 10851 2.21 1100.0 0.99 STH FLOOR CORRIDOR 1 5.81 Jul-16001 10401 2.81 1062.01 0.98 I I i Hourly Analysis Program v4.91 Page 2 of 6 I