HomeMy WebLinkAboutEngineering (2) 1
36" X 80" -
32" X 80"
REPLACE DOORS IN 2 OPENINGS ONLY.
NEW DOORS TO BE IMPACT RESISTANT-
HURRICANE SHUTTERS NOT REQUIRED.
JUL
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WDTH, HGT. FTG, ZONE POS. NEG. (N.O.A.#) POS. NEG,
1 36 80 20.00 4 36.1 -38.3 FL166741 ----50-0--1-50.0 FRONT ENTRY-LSMI
2 32 80 17.78 4 36.8 1 -40.0 FL16674.1 50.0 1 -50.0 SIDE GARAGE-LSMI
U-FACTOR SHGC
FL16674.1 0.16 0.01
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 114" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 114"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 11 FT 7 IN
BOZZINI RESIDENCE
8106 COQUINA AVENUE DOOR REPLACEMENT PLAN
FORT PIERCE, FLORIDA