HomeMy WebLinkAboutNotice of Commencement J
�y O
8�
0
V '
A 4
x
�o
rn
CD W
Q Q
O O
3 3
=? -n
N m
O
O
O
3 �.
(O �
n
� r
Z Dp
CCD a
CL
0 0 0
3 3 3
w
co
CD
' c, Patricia Amaro Florida Window and Door Co.
J
o ; � 11124 Lands End Chase 7108 Fairway Drive,Suite 120 Tel.(561)848-4900
Port St. Lucie, FL 34986 Palm Beach Gardens,FL 33418 floridawindowanddoor.com
Florida Window and Door Co.
7108 Fairway Drive,Suite 120 Tel.(561)848-4900
Palm Beach Gardens,FL 33418 floridawindowanddoor.com
Property Information Building Information
Owner: Patricia Amaro Wind Zone: 160 MPH.
Address: 11124 Lands End Chase Exposure Category: C
Port St.Lucie,FL 34986 Minimum Building Dimension: 50 ft.
Mean Roof Height: 14 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 End 74 96 7 30.0 -37.9
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code.
Page 1 of 1
Florida Building Code Online Pagel of 5
Business & Professional R-ga
=1 .Ct L)epM:enty SCIS Home Log in User Registration Hot Topics SutMNt Surcharge Stats 8 Fads Publitatio FBC Staff SCIS Site Map Units Search
Busines
Apps`Profess �a"l 6R:Public User
Regulation
® ProdudAnowal Mmu>Product o',inollcation Search>&MhMVZLLa>Application Dedra
FL# FL15180-R1
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer Plastpro Inc./Nanya Plastics Corp.
Address/Phone/Email 5200 W CENTURY BLVD.
LOS ANGELES,CA 90045
(440)969-9773 Ext 16
rickw@rwbldgconsultants com
Authorized Signature Vivian Wright
rickw@rwbldgconsultants.com
Technical Representative Scott Johnson
Address/Phone/Email 5200 W Century Blvd.
Los Angeles,CA 90045
(440)969-9773 Ext 18
scottjohnson@plastproinc.com
Quality Assurance Representative Ron O'Connell
Address/Phone/Email 5200 W Century Blvd.
Los Angeles,CA 90045
(440)969-9773 Ext 16
ronoconnelt@plastpro.com
Category Exterior Doors
Subcategory Swinging Exterior Door kmemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
® Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E.
the Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 1 31 2018
Validated By Ryan J.King,P.E.
® Validation Checklist-Hardcopy Received
Certificate of Independence FL15180 R1 COI CERTIF],WE of INDEPENDENCE.odf
Referenced Standard and Year(of Standard) SSS I year
ASTM D1929 1996
ASTM D1929 2006
ASTM D2843 1999
ASTM 0635 1998
ASTM D638 2003
ASTM E1300 2004
ASTM E84 2005
ASTM G26 1995
http://www.floridabuilding.org/pr--,Ipr_app_dtl.aspx?param=wGEVXQ,, tDgsidcHd6ieP8H... 7/16/2016
Florida Building Code Online Page 2 of 5
TAS 201,202,203 1994
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FLIS180 RI Eauly Enulvalencv Of Standards.odf
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/24/2015
Date Validated 04/26/2015
Date Pending FBC Approval 04/28/2015
Date Approved 06/23/2015
Summary of Products
Go to Page 0 0 Page 1/2 0 0
FL# Model,Number or Name Description
15180.1 a.Smooth/Wood 6'8"Impact"Glr_ed Fiberglass Single Door-Outswing(X-
Grain/Rustic/Mahogany Series N Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FLIS180 R1 II Inst 15180.1.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure,N/A Evaluation Reports
Other.See INST 15180.1 for Design Pressure Ratings,any FL15180 RI AE Eval 15180.1.0df
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.2 b.Smooth/Wood 6'8'Impact"Glazed Fiberglass Single Door with"Impact"
Graln/Rustic/Mahogany Series N Sidelite-Outswing(OX or XO-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FLIS180 R1 II Inst 15180.2.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact ReslstaM:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Re'pbrts
Other:See INST 15180.2 for Design Pressure Ratings,any FL1S180 Ri AE Eval 1S180.2.9df
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.3 c.Smooth/Wood 6'8"Impact"Glazed Fiberglass Single Door with"Impact"
Grain/Rustic/Mahogany Series N Sidelites-Outswing(OXO-Configuration)
Fiberglass Door r
Limits of Use Installation Inatructilons
Approved for use in HVHZ:Yes FLIS180 R1 II Inst 15180.3.odf
Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Incependent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.3 for Design Pressure Ratings,any FLIS180 RI EF Eval 15180.3.odf
additional use limitations,installation instructions and Created by InGependent Third Party:Yes
product particulars.
15180.4 d.Smooth/Wood 6'8"Impact"Glazed Fiberglass Double Door-Outswing(XX
Graln/Rustic/Mahogany Series N -Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FLIS180 R1 II Inst 15180.4.odf
Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.4 for Design Pressure Ratings,any FL15180 R1 a Eval IS180.4.odf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.5 e.Smooth/Wood 6'8"Impact"Glazed Fiberglass Double Door with"Impact'
Grain/Rustic/Mahogany Series Sidelites-Outswing(OXXO-Configuration)
Fiberglass Door
http://www.floridabuilding.org/pri'pr_app dti.aspx?param=wGEVXQm4DgsidcHd6ieP8H... 7/16/2016
Florida Building Code Online Page 3 of 5
Umits of Use Installation Instructions
Approved for use in HVHZ:Yes FLIS180 R1 I7 Inst ISIM5.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Relaarts
Other,See INST 15180,5 for Design Pressure Ratings,any FLIS180 RI AE Eval 15180.S.odf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.6 f.Smooth/Wood Grain Series N 8'0"Impact"GI)zed Fiberglass Single Door-Outswing(X-
Fiberglass Door Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL151$ 14 Inst 15180.6.odf
Approved for use outside HVHZ:Yes Verified By: Lyddon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure,N/A. Evaluation Reports
Other:See INST 15180.6 for Design Pressure Ratings,any FLIS180 R1 AE Eval 15180.6.ndf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.7 g.Smooth/Wood Grain Series N 8'0"Impact"Glazed Fiberglass Single Door with"Impact"
Fiberglass Door Sidelite-Outswing(OX or XO-Configuration)
Limits of Use Installation Iretructions
Approved for use in HVHZ:Yes FLIS180 RI I :Inst 15180.7.odf
Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.!for Design Pressure Ratings,any
additional use limitations,installation instructions and Created by In ependent Third Party:Yes
product particulars.
15180.8 h.Smooth/Wood Grain Series N 8'0"Impact"Glized Fiberglass Single Door with"Impact"
Fiberglass Door Sidelites-Outsning(OXO-Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 Ri I(ti Inst 15180.8.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Inoependent Third Party:Yes
Design Pressure:N/A Evaluation Resorts
Other:See INST 15180.8 for Design Pressure Ratings,any FLIS180 R1 &E Eval 15180.8.odf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars. -
15180.9 Smooth/Wood Grain Series N 8'0"Impact"Glazed Fiberglass Double Door-Outswing(XX
Fiberglass Door -Configuration).
Limits of Use InstallationInftruetions
Approved for use in HVHZ:Yes FL15180 R1 L�inst 15180.q.odf
Approved for use outside HVHZ:Yes Verified By:L"on F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A . Evaluation Reports
Other:See INST 15180,3 for Design Pressure Ratings,any ELIS180 RI /'
additional use limitations,"installation instructions and Created by Independent Third Party:Yes
product particulars. "'
15180.10 J.Smooth/Wood Grain Series N 8'0"Impact"Glazed Fiberglass Double Door with"Impact"
Fiberglass Door Sidelites-Ou wing(OXXO-Configuration)
Limits of Use Installation Iilptrudions
Approved for use in HVHZ:Yes FL15180 Ri it'Inst 15180.10.odf
Approved for use outside HVHZ:Yes Verified By: Lrdon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Indgpendent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.10 for Design Pressure Ratings, FLIS180 Ri AE Eval 15180.10.odf
any additional use limitations,Installation instructions and Created by Indlpendent Third Party:Yes
product particulars.
15180.11 k.Smooth/Wood 6'8"Impact"Oiaque Fiberglass Single Door-
Grain/Rustic/Mahogany Series N Inswing/Outswing(X-Configuration)
Fiberglass Door
Limits of Use Installation IAstructions
Approved for use in HVHZ:Yes FLIS180 RI fJ'Inst 15180.1i.odf
Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes' Created by Independent Third Party:Yes
Design Pressure:N/A' Evaluation Reports
Other:See INST 15180.}1 for Design Pressure Ratings, FLIS180 Ri QE Eval 15180.11.Ddf
any additional use limitations,installation instructions and. Created by Inlependent Third Party:Yes. _
product particulars.
15180.12 I.Smooth/Wood 6'8"Impact"Opaque Fiberglass Single Door with"Impact"
Grain/Rustic/Mahogany Series N Sidelite-Outsie!ng(OX or XO-Configuration)
i Fiberglass Door
hq://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQ,.XrtDgsidcHd6ieP8H... 7/16/2016
Florida Building Code Online Page 4 of 5
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 Ri II Inst IS180.12.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A, Evaluation Reports
Other:See INST 15180.12 for Design Pressure Ratings, FLIS180 RI AE Eval 15180.12.odf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.13 m.Smooth/Wood 6'8"Impact"Opaque Fiberglass Single Door with"Impact"
Grain/Rustic/Mahogany Series N Sidelites-Outswing(OXO-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 Rl Il Inst 15180.13.ndf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.13 for Design Pressure Ratings, FLIS180 RI A� Eval 15180.13.ndf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.14 n.Smooth/Wood 6'8"Impact"Opaque Fiberglass Double Door-
Grain/Rustic/Mahogany Series N Inswing/Outswing(XX-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FLIS180 RI II Inst 15180.14.ndf
Approved for use outn!de HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes`; Created by Ingependent Third Party:Yes
Design Pressure:N/A' Evaluation Reports
Other:See INST 15180.L4 for Design Pressure Ratings, FLIS180 RI 0jE Eval 15180.14.odf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.15 o.Smooth/Wood 61"Impact"Opaque Fiberglass Double Door with"Impact"
Grain/Rustic/Mahogany Series N Sidelites-Outswing(OXXO-Configuration)
Fiberglass Door
Limits of Use Installation I60tructions
Approved for use in HVHZ:Yes FLIS180 R1 II Inst 15180.15.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.15 for Design Pressure Ratings, FLIS180 R1 AE Eval 15180.15.odf
any additional use limitations,Installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.16 p.Smooth/Wood Grain Series N 8'0"Impact"Opaque Fiberglass Single Door-
Fiberglass Door Inswing/Outswing(X-Configuration)
Limits of Use Installation Inptructions
Approved for use in AVHZ:Yes FL15180 RI IL Inst 15180.16.odf
Approved for use out:Nda HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Realstaft Yes Created by Independent Third Party:Yes
Design Pressure:N/A ' Evaluation Reports
Other:See INST 15180.16 for Design Pressure Ratings, FL15180 RI AE Eval 15180.16.odf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.17 q.Smooth/Wood Grain Series N 8:0"Impact"Ojaque Fiberglass Single Door with"Impact"
Fiberglass Door Sidelite-Outswing(OX or XO-Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FLIS180 RI 1I Inst 15180.17.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.17 for Design Pressure Ratings, FLIS180 III At Eval 15180.17.odf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.18 r.Smooth/Wood Grain Series N 8'0"Impact"Opaque Fiberglass Single Door with Sidelites-
Fiberglass Door Outswing(OXO-Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FI15180 Ri IL Inst 15180.18.odf
Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.18 for Design Pressure Ratings, FLIS180 R1 AE Eval 15180.18.odf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars. .
http://www.floridabuilding.org/pr,'pr�_app_dtl.aspx?param---wGEVXQwtDqsidcHd6ieP8H... 7/16/2016
Florida Building Code Online Page 5 of 5
15180.19 s.Smooth/Wood Grain Series N 80"Impact"Opaque Fiberglass Double Door-
Fiberglass Door Inswing/Outswi,.rtg(XX-Configuration)
Umits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15180 Ri II Ina 15180.19.ocif
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes` Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.19 for Design Pressure Ratings, FL15180 Ri AF Eval 15180.19.odf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15180.20 t.Smooth/Wood Grain Series N 8'0"Impact"Opaque Fiberglass Double Door with"Impact"
Fiberglass Door Sidelites-Outswing(OXXO-Configuration)
Umits of Use Installation Instrulctions
Approved for use in HVHZ:Yes FLIS180 R1 11 Inst 15180.20.odf
Approved for use out#+de HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15180.20 for Design Pressure Ratings, FL15180 Ri k, Eval 15180.20.odf
any additional use limitations,installation Instructions and Created by Independent Third Party:Yes
product particulars. h
Go to Page S 0 0 Page 1/20 0
0
QatuLla
1
::2801 Blair Stone Road.Tallahassee FL 32399 Pho*r �850-487-1824
The State of Florida Is an Aa/EEO employer.Uevrilia 2007-2013 State of Florida.::i I01C01::Accessibility Stir[::Refund Statement
Under Florida law,email addrtlsses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.]rc#oad,contact the office by phone or by traditional mail.If you have.any questions,please contact 950.487.1395.*pursuant to
Section 455.275(1),Florida StaWbes,enactive October 1,2012,licensees licensed under chapter 455,•F.S.must provide the Department with an email address 9
they have one.The smalls provided may be used for official communication with the licensee.Howeva,•email addresses are public record.If you do not wish to
supply a personal address,pleas*provide the Department with an email address which an be made available to the public.To determine If you are a licensee under
Chapter 455,F.S.,please Wtk bat.
Product Approval Accepts;
Credit Card
S81t
}y,
http://www.floridabuilditlg.org/pi,,.pr_app_dtl.aspx?param=wGEVXQwtDgsidcHd6ieP8H... 7/16/2016
i
--
'—" last ro � ��
p p
5200 W.CENTURY BLVD.
LOS ANGELES,CA 90045
Smooth/ Wood Grain o
Series N fiberglass Door
OUTSWING 74.00'MAX.OMALLRAW WIDTH
�
"IMPACT'
- _-- =-
(3049t/LL Nola Z
1. This product hos been evaluated and is in conVkmce with the Stn Edition 14)Faida BukkV Code & > <
shuclwd requirements hckx kg the MO Veloctty Hurricane Zone•(HVHZ).
W
2. Producrt anchors shall be as listed and spaced as shown on details.Anchor ernbedment to base
f
shd be beyond wall dressing or stucco. X X ( a
& When used in the•HVHZ•this product comples with Section 1626 of the Paido Building Code and does not � a
require an impact resistant cove ft. 6
4. When used In areas outside of the•HVHT mqutkg wild borne debris protection this product complies with
Section 1609.1.2 of the MC and does not require an irrlpact resistant covering.This product meets.,
,rel•D"
leand klckrdes Wind Zone 4 as defined In ASPM E1996 and Section 16M.122 of the fBC. �
P O
5. For 2x stud ha nk construction,anchortng of these units shd be the somas that shown for 2x bu& I `V
w masonry corrahuctiom j f3 Z
6. Site corldBions that deviate ham the distorts of this drov,Mlg regalgtn
e further eneerklg analysis by a licensedengineer or registered architect.
7. ftproduct meets water Ini tration req Aements for'F W.
rAWOFCOMM
SPIWO DOCtih10M i
1 TVpicoi ekvation a notes o i
2 Door panel delals and detail ^z v
3 Horizontal am seeMore
4 Vertical am sections so"Mme' ah 02 21 12 i
5 Buck and frame 2X buck masonry conshuctlon sry•. N.T.S.
dRaw re tx
1X ,dc cornhuction .:. M.a: JK i
7 deta6cm or.
B M of mawak a 74.0'x 96.50" 20.50"x>82S �T +50.0 -50.0 ORO"NO.:LFs 3
FL-15180.9 "
0
s„m
—L OF J 0
R1 1 AWEITIARadd�Rodutt AaoronldFL-151x1[-lkawYrratGmntlEL-151801-10d.n.9-2 - •
95.25 MAX.DOOR PANE:H9GIlfa*sii
alas MAX O.A.R2AME HEICiHf
—76.25'MAGI.DLO.HEO f I I SE
4
i 4.5
ll�S MAX
L274'—�-i
x-176'
We -
g/
0.07P o
Mr
Ift 43400
� � m
�I PRODUCT: hot
PLASTPRO INC. troF43s oa tae ��' :'•••```
Z N FIKKLASS DOOR ����/IIIIIIIIA,``
IR ` PART OR ASSEMBLY: sU0D910 CONSULTANTS. INC.
p vl 12? 15 UPDATE TO STN ED. 2014 FEC JK P.O. sox 230.Vok$co.PL 33598
o N NO A 8Y DOOR PANEL DETAILS PhorN No: 013.959.9197
R 1 N AND C1AZINC DETAIL FOMC& No. 9513
o 2012 M.W.GUI—Im COME—iwo.
R 4 ro,Inc PERMANFliM°AA�RodiM AoorowltlR-1516.'.C-DrawNMCvle:a�Fl-IS].BQ7•IOdug 9.3
T
e
a v
w r
� A
V
any
ww
® m
o
aleN.
s
ts
r s w w
h70 � wa A
o
x
V p
0
A v
n v
r
w O
o '
n
NIL43400
g
PRODUCT:
L 3 4 o PIAS(PRO INC. 4- No. 43409
I N Z + FTEIERGLASS DOM '�l1J111111111\,,
PART OR ASSEMBLY: ck BUILDING CONSULTANTS. INC.
N I
13 LIPOATE jRL
4 FBC JK P.O. Boa 230.Vokko.FL 33696
x . N HORIZONTAL CROSS SECTIONS Pkerr Ne.: st3.969.9/97
APE CA Ne. 9613
O ao i a a.w.•�no:He Oow�u�.wnv n.o.
X.10' W ro kK PERMANUMAWI&Product rove -ISMOkC-MVWM9ACwMAK-153[0.1-10Awa 9-1
v
A s
r
CIINKJ
7O
E'
♦ A
O V ' •
I70 ♦a
r
O.1S' � •
(IYN
t� n
1-1/4 MAV.
EMB.prP.)
1-114 MIN
'N-11• EMB.(TYP.)
Lo
I70
• D
acw
D
A 3_
' V O fTt
•D 0
. O
PO
Im 30
a.W
D
x xA
m
�a •! °
A
1-1/4 MN.
Be.(IYP.)
_*:• N9.43400
�23�s i
$ PRMCT: Mw O
•1 @ PLASTPRO INC. ML No.F43409 i��i'' ••.�R61da•',```��
I'N to Z N
n9EKLASS WOR ./� '!!!l11111111E1E�
R r ` PART OR ASSEMNLY: ' BURAINO CONSULTANI3• INC.
c x to r t is uPnATE 70 STH m. 2014 F8C JK VERTICAL CROSS SECTIONS JI�Ii P.O. em ZJO.VdAoe.ft 33696
C. io ro NO By Ii Phom Na:813.WD.9197
R I _ PSPE CA H. 9613
O 2012 w.w.s.--
0. 1 Inc PFAMANENi�ilpidA Roduct ACorowlt�F41558gC•Dr+winMCvrtwrt�Ft-151lOa-SOdwa 9.5 •
P 10 —
if
S Z y
a O.C.mma
a
0
1 1 1 I 1
77-1
MV MAX
Iet m
,,,• I � 1 1 _ t 1 I
O.C.(I1T.)
--26' -W 2S 9.25
>R pp
171
V
F
s
a�w
o
Nff.19109
PRODUCT:. I,pddon F. SahrnWt --i-••~-•ROIa}•'' ,��
PIASTPRO INC.
FlSMI ASS R
p, ti PART OR ASSEMBLY: y( BUIDINO CONMXTANI3. INC.
p x to .. f 13!UPDATE TO 3111 ED. 2014 FE1C JK +. P.O. Box 230.Valrleq FL 331596
�o to ro NO BUCK AND iRAME ONCHORMG 2X Phar No.: 613.969.9197
BUCK MASONRY CONSTRUCTION 69PE CA Na 9613
O 2012 R.W.BU—INR CONS—i—iiI INC.
t
R Inc PERMAN Product R-IS C-Dr L-15160.1-10 9-6
F N
9.
Ak
. a&
n �1¢I� 977g a
1
Q � Q t3
N
9
73� N Y•
a
� 3
X ?
m
I I I I 1
x -
N� N
m
o z
I 1 I I1 1 II ^ a
17.=MAx.—i�--�-1
a.C.pp.'
•1+ Tb' --�26' '-1 211 *
$ _ r? r: 1.
Y
PRODUCT:
1 3 Y c PLASIPRO INC. F.43409 �'�i� •~ `��`
U 2 N Schmldt
nsDOOR
��JJJJlllllll�t�,
PART OR ASSEMBLY: BIMLCINO CONb1 UMTS. INC.
p x tq I IS UPDATE TO 37N ED. 2014 FUC JK P.O. 6OK 230.VaWm. PL 33396
r0 ro NO DATE BY FRAME ANCHORING IX BUCK Phe Ne.: 613.939.9197
MASONRY CONSTRUCTION POPE C.A. No. 9613
O 90:4 R.W.OUILDINO CONS-INO.
0. Rrc PERMANENWWd&Product L-15180 C-Onwi Cwre -1S1l111.10 9.7 '
A-A Me
v
� � y
y
�I {--oar
0
97
m
D
O
ro
O
y
C
x
0
u�
k v y
O
2.6S—�{
n
• x
H
x
7a
C.
rO
T ti
a
OW
Mom
Ne.49W9
$
zx-sisrPROD1Cr: CROP'..
L~
F. Sah""
PiASTPRO INC. FL No. 43409IIIIIIS.5'S5S•`���
Q m r- -f PART OR ASSEMBLY: fryr 9VILOINO CONSULTANTS, INC.
O y x in 1 15 UPWTE TO STN ED. 2014l:HC JK ASTRAGAL �� • P.O. Box 230.VaHm. FL 33395
e N NO DATE BY Pham Na.:813.889.9197
N FBPE CA No.9813
O ao r a..w. c.....r.. rrc.
i
ML OF MATEMALS 456'
M# owirwN MAMM I =
A 1X BUCK SG-0.55 WOOD * a
B 2X BUCK SG-0.55 WOOD
C I/4"MAX.SHIM SPACE �� •.,y l �� i
D CONCREIE SCREW
MMASONRY OOO PSI MN.CONCRETE ONFORMING TO ACI STEL 2.m� ,,,,���irp 11�� � J' $
N
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE
••
_ STEEL �
H. 114"x 3.1/ PFH ELCO ORITW CONCRETE SCREW STEEL 456" H I I
J 114"X 33/4"PFH ELCO OR BW CONCRETE SCREW STEEL
K /9 X 2-1/7 PFH WOOD SCREW STEEL
L #9X 2-1/7 PFH WOOD SCREWw
Sim. -
M 88 X 7 PFH WOOD SCREW I
7 FORCE 5 WEATHERSTRIPPING BY ENDURA FOAM Fes-- 2A r--I
8 COMPRESSION WEATHERSTRIP QLON 650 BY SCHLEGEL FOAM
9 4"XC BUTT HINGE STET 21
10 89 X 1"PFH WOOD SCREW STEIN ci
11 N9 X 3/4'PFH WOOD SCREW STET z Y S
20 FINGER JOINTED PINE FRAME,HEAD 3 HINGE JAMBS WOOD
21 POLY FIBER JAMB COMP./VINYL `S
27 LATCH STRIKE PLATE STEEL m�
28 DEAIMLT STRIKE PLATE SIM
W OUTSWM*THRESHOLD BY DLP ALUM./WOOD � oI
36 EXTRUDED ALUMINUM ULTIMATE ASTRAGAL"BY BOURA ALUMINUM . a
37 SUDEBOLTROD STEEL
38 93/4"LENGTH TOP BOLT RETAINER ALUMINUM
39 93/4"LENGTH BOTTOM BOLT RETAINER ALUMINUM
40 DOOR PANEL-SEE DOOR PANEL DEW L SHEET FOR CONSTRUCTION DETAILS
87 ASTRAGAL STRIKE PLATE STEL Qy(J, nBResRFOLn�r Rxr
RIn
e 0
n -
N O J
O c
Z p
W..L N.T.S.
0
owc.er: JK i
aaL n: LFS 3
D WW N0. C
FL-15180.9 N
0
sNm�a� o