Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 Business & Professional r t FA= �ra+ m DezimerliJ BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications ! FBC Staff BCIS Site Map Links Search Busines Professial Product Approval USER:Public User Regulation Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL10674-R10 Application Type Revision Code Version 2014 Application Status Approved, Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who Robert J.M. Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W. Knezevich, PE Validation Checklist- Hardcopy Received Certificate of Independence FL10674 R10 COI 2015 01 COI Nieminen odf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2... 9/11/2015 Florida Building Code Online Page 2 of 2 Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/22/2015 Date Validated 04/23/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/23/2015 Summary of Products FL# IlModel,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab, 5-tab,laminated,starter and hip&ridge Shingles and Starters shin les Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674 R10 II 2015 04 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R10.Ddf Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE- 59166 Design Pressure: N/A Created by Independent Third Party:Yes Other: Refer to ER, Section 5. Evaluation Reports FL10674 R10 AE 2015 04 FINAL ER OC ASPHALT SHINGLES FL10674-R10.odf 11 Created by Independent Third Party: Yes Back Next Contact Us:: 1940 North Monroe Street Tallahassee FL 32M Phone:850-487-1824 The State of Florida is an AA/EEO employer.Cooyriaht 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395. 'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® ® sm-uirlty%i}TRIC., http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2... 9/11/2015 EXTERIOR RESEARCH&DESIGN,LLC. Certificate ofAumouzation#9s03 3j3CHRISTIAN STREET,UNIT#1] !ERD OXFORD,CT 06478 TRINITY , PHONE:(ZO3)262-g24S FAX:(2O3)26Z9Z4J EVALUATION REPORT Owens Corning Evaluation Report 03794Q.02.12'RS One Owens Corning Parkway FL10674'RlO Toledo,0H43659 Date ofIssuance:Q2/06/2012 Revision 5: 04/22y2015 Scopo This Evaluation Report is issued under Rule 61G20'3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5 1h Edition(2014)Florida Building Code sections noted herein. DEszn/rnow: Owens Corning Asphalt Roof Shingles LAooums: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance ufthis Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Thnity\ERD requires complete review of this Evaluation Report relative toupdated Code requirements with each Code Cycle. uovEmnuEmswn The Evaluation Report number preceded by the words °Trnity\ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. |msPEcnom: Upnnrequest' acupyofthisentieEva|uadmnReportsha|| beprovidedtothauserbythemanutacturerori|s distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists ofpages lthrough 6. Prepared by: The facsimile seal appearing was authorized by Robertw"rn.°n, Robert1--.N—|e—nm—in—en,P,E. ,�c��w�vw� nm��~w="° "",* � � =m m�aoxe«u�v�wwusmxamxm^DCA A�oao *==*Signed,sealed hardco'ieshave been transmitted mthe Product Approval Administrator and m*°named client CERTIFICATION o"INDEPENDENCE: 1. Tnnitv|EnDdoes not have, nor does itintend to acquire or will it acquire, a financial interest in any company manufacturing o, distributing products uevaluates. 2� Trinity|[xDi,not owned,operated urcontrolled bwany company manufacturing o,distributing products itevaluates. 3. Robert wieminen'P.c.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This i,a building code evaluation. Neither Trinity|sno no,Robert Niemioen, P.E. are, in any way,the Designer of Record for any project onwhich this Evaluation Report,n,previous versions thereof,is/was used for permitting o,design guidance unless retained specifically for that purpose. TRINITY I ERa ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance with the fallowing sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM 07158 2008 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 Miami-Dade(CER1592) FRC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic'and Supreme*are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire'"are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition Duration', Duration Premium Cool, TruDefinition* Duration* Designer Color Collection, TruDefinition*Oakridge',Oakridge'and WeatherGuard'HP are fiberglass reinforced,laminated asphalt roof shingles. 4.2 Berkshire Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Pius and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity(ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H.indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph(Vmt=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS Certificate of Authorization x9503 FL10674-R10 Revision S:04/22/201S Page 2 of 6 TRINITY ERD 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per ESC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions: Y Berkshire•shingles require minimum five(5)nails per shingle. ➢ WeatherGuard•HP shingles require minimum six(6)nails per shingle. Devonshire'"shingles require minimum six(6)nails per shingle. Starter Strip Plus requires minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing—Classic®&Supreme: NNonnaAnd AArias Nkm srd orind �Yy� Normal Mansard or Aron pin Aron pan vlintos norrnales Arias vie ntos lwrtii �Aram Nigh Wind tosvinis y pars YlarKoa nor►»a/ia A►iai YIMtOf Iiri1'tas ir 2- Ir •� ;iAII�. it• —..IBS �. ti tw t� Z� is z. 1. •i it Exposure 6 5/i•Exposure Exposkldn 6.2.6 Minimum Nailing—Berkshire": Sea6rd swp Seabrg$4 Lo tht do"Vida to W do oothdIr i t�-�► i 4---!• a�---i i if�T M w-i• i.1�1•i 1-x-1• ir B ih' 9 Yf 9 Yf 8 Yf t 8 Yt 8 YC 8 Yf 8 Yf r t r A*wIt roorogcoamal Cmunto do Wo do aWto Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R5 certificate of Authorization#9503 FL10674-R10 Revision 5:04/22/2015 Page 3 of 6 TRINITY j ERa 6.2.7 Minimum Nailing—Devonshire'": W �— Nails Nails Ten i`Spots of Asphaft Roof Cement 6.2.8 Minimum Nailing—Durations,TruDefinitions Duration, Durations Premium Cool&TruDefinition•Duration Designer Color Collection: 4 Nail Pattern 6 Nail oa atm n saft1b; Esquemad•4davos Pattern ieamMaedoA t. SuwNailOtasMatag ams vrNtfi do6da ��� — aL ria•at•rtt sir aArrecaa �.. =11T4 datiarosSuwNale t • t aOMar•trCarar. t _1— —• T WOW* \ Ylraaii� ackri{g ZaCer�qq eau 11(0111 Il�leaaa�� IIII —tr AID do cow W9411. 72' Ina bt's"Hxpoww Nab Bb puig.di exposleidrr Claw Ssb polo,de aYposleksn SW t:aapasae Nails W EP Osm 5%padp.ds wW*bn parous 5%pulp.de a4vOddn 6.2.9 Minimum Nailing—TruDefinitionOakridges,Oakridges: 4 Nail Pattern 6 Nail Pattern Esquarna eon 4 dams Esquaw coat 6 dams r r Ir T T T2 —il►� 6 618"BtpaF6n sum Nab 6 518"dM dew Nab b 618"Expoeww Cbvm 5 bJB"Exposuw Exposid6adaS6/Spulg. C6tvos Erposlotda+da6b/8p+dp. Etrpasloi6adt5618p+d9 ExyostcW de 66/8putp. 6.2.10 Minimum Nailing—WeatherGuards HP: sod-Avowal .t;. fiiliaeiewm7iaael�r Iltail tlie• let!as b lien•ab>ladis Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 FL10674-R10 Revision 5:04/22/2015 Page 4 of 6 TRIM Y 1 ERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard' HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions, using four(4)nails per shingle. Installation of DuraRidge—Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using two(2)nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations,including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshires'Hip&Ridge and High Ridge: Fig.1 a Fig.2 t""— PfsM&VVNnd Dksaba A TapViwe SideNsw A Nays NsiIs 4 �\ A\ r TnP 1we al T 1 �" Pira 4 i � i t Vt \ I r i I � 1 6.3.4 Minimum Nailing—Hip&Ridge with Sealant: em Fig.2-NighWindF g m 4Nj rh�nr Shingie— nd Dtsaard 2" 2" E cem 1" 1" i_4. ss� "t 12" Fastiening 61/e" 5"Expossoe Distance 12" 6.3.5 Minimum Nailing—WeatherGuard"HP Hip and Ridge: v4 Fig.C Hip&Ridge Shingle Fastening Fig.A TaP V bx Prowssq riMM \ A Mohs Nslls R EIjIO11tN1 Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 FL20674-R10 Revision S:04/22/2015 Page S of 6 r TRINITY I ERa 6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard +-11'—• Wind Direction Sad�nt> Fastening 6'Exposure 12• Saalan Fajta.7%* 7'h' R.Exposure Roof Caerau i,_12•_._„I I I 6.3.7 Minimum Nailing–DuraRidgeT"Hip&Ridge Shingles: Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. To View �—Dlir�mdn >i �d�iat 1• N Dirocdfn dsl womb pra"wit. I cures. qqor � I j I Ch- 12- 7. 1-7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC–QUA9625;(414)248-6409;karen.buchmann@u(.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 FL10674-R10 Revision 5:04/22/2015 Page 6 of 6