Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Certification for Design Load Compliance
Castle Impact Windows FACTORY DIRECT-SINCE.1969 -' 1 COMPLETE HURRICANE PROTECTION SOLUTIONS 7089 Hemstreet Place West Palm Beach,FL 33413 806.643.6371 Property Information Building Information Owner.; MESSINEO, JOE Wind.Zone: 1,65:WH. .Address: 2410 OAK.DRIVE Exposure Category-, D FORT PIERCE,FL 34957 Minimum Buildirig Dimension: 40 ft. Mean Roof Height: 2.5 ft. Risk Category Il Design Pressure. Calculations- Openuig Location Device Device, Device. Max Positive Max Negative Number Zone Width(in). Height,(in) Elevation(4) Pressure(psfl. Pressure(psf) 1 Int 37.5 _52.75 _ 7 46.3; -50.3 2 Int 37.5 52.75 7 46.3 -50.3 3 End 62 86.25 7 .43.2 -55.0 4 I.nt 45:5 48.75. '7 45.9 --49.9 5, Int 45.5 4.8.75 7 '45.9 -49.9 6 Int 36.75 8475 7 _ _ 44.9 -48;9 7 Int 40.5 41 7 46.8. -5.0.8 8 Int 25.5 36.75 7 47.2 -51.2 9 Int 25.5 36:75 7 47.2 _ -51.2 10 Int 48 29 7 47.2 -51.2 11 Int 48 29 7 47.2 ,=51.2 12 Int 48 29 7 _ 47.2 -51.2 13 Int 48 29 7 47:2 -51.2 14 Int 37.5 52.75 7 46:3 . -503 15 _ Int 37:5 52.75' 7 46.3 -50:3 16 Int 48 67.25 7 44.7 _ 17 Int 72 85 7 _ _ 42.8 -46.8 18 Int 76.25 52.5 7 44.1 -48.1 19 Int 71.7.5 85.25 7 42.8 -46.8 20 Int 25.75 3635 7 47.2 -51.2 Prepared in accordance wilh:ASCE 7-10,Chapter-30,Wind Loads-Components and Cladding.Sth Edition(2014)Florida Building Code. Page 1 of 1 Customer: MESSINEO WorkOrder Number: 04222016003 N0301 Sales Engineer- Wall Opening Opening Shutter Shutter Anchor Sections Opening# ing Pressure Width Height Width Height Spacing Opening# 1 1 -50.3 37.5 52.75 51.75 57.75 9"o.c. 1 9"o.c. 2 2 -50.3 37.5 52.75 51.75 57.75 9"o.c. 1 9"o.c. 3 3 -55 62 86.25 73.125 87.25 9"o.c. 1 9"o.c. 4 4 -49.9 45.5. 48.75 _57.5 53.75 9"o.c. 1 9"o.c. 5 5 -49.9 45.5 48.75 1 57.5 53.75 9"o.c. 1 9"o.c. 6 6 -48.9 43.75 84.75 57.5 85.25 9"o.c.. 1 6"o.c. 7 7 -50.8 40.5 41 51.75 46 9"o.c. 1 9"o.c. 8 8 -51.2 25.5 36.75 40.25 41.75 9"o.c. 1 9"o.c. 9 9 -51.2 25.5 36.75 40.25 41.75 9"o.c. 1 9"o.C. 10 10 -51.2 48 29 63.25 33 9"o.c. 1 9"o.c. 11 11 -51.2 48 29 63.25 33 9"o.c. 1 9"o.c. 12 12 -51.2 48 29 63.25 33 9"o.c. 1 9'b.c. 13 13 -51.2 48 29 63.25 33 9"o.c. 1 9"o.c. 14 14 -50.3 37.5 52.75 51.75 57.75 9"o.c. 1 9"o.c. 15 15 -50.3 37.5 52.75 51.75 57.75 9"o.c.. 1 9"o.c. 16 16 -48.7 48 67.25 63.25 72.25 To.c. 1 9"o.c. 17 17 -46.8 72 85 86.25 87.5 9"o.c. 1 3"o.c. 18 18 -48.1 76.25 52.5 92 57.5 9"o.c. 1 9"o.c. 19 19 -46.8 71.75 85.25 84.625 87.75 9"o.c: 1 3"o.c. 20 20 -51.2 25.75 36.75 40.25 41.75 9"o.c. 1 9"o.c.