Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 4 RECU."D JU1 ? 9 2016 ,p Ac'y�,n t �'`���t}$- �`.I VnSSI,"� �«sz�' F16,ka L'p' rnen(u` BCIS Home ' Log In ! User Registration Hot Topic Submit Surcharge I Stats&Facts Publications S FBC Staff BCIS Site Map Links f Search Busines Product Professibr"�61 USER:Public U�seerOVal ,� � Relclulation 7 Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL15220-R1 Application Type Revision Code Version 2014 Application Status Approved Comments Archived -0— Product Manufacturer Plastpro Inc./Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES,CA 90045 (440)969-9773 Ext 16 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 16 ronoconnell@plastpro.com Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer R Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J. King,P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL15220 R1 COI CERTIFICATE of INDEPENDENCE.pd Referenced Standard and Year(of Standard) Standard Year ASTM D1929 1996 ASTM D2843 1999 ASTM D635 1998 ASTM D638 2003 ASTM E1300 2004 ASTM E84 2005 ASTM G26 1995 TAS 202 1994 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yV VKJZ 1 Q... 7/29/2016 Florida Building Code Online Page 2 of 4 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect &15220 R1 Equiv EquivalencFOf Standards.odf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/24/2015 Date Validated 04/26/2015 Date Pending FBC Approval 04/28/2015 D. prov � 06/23/2015 i Summary of Products FL# odel,Number or Name Description 15220.1 a.Smooth/Wood 6'8"Non-Impact"Glazed Fiberglass Single Door- Grain/Rustic/Mahogany Series N Inswing/Outswing(X-Configuration) Fiberglass Door Limits se Installation Instructions oved for use in HVHZ:Yes FL15220 R1 11 Inst 15220.1.udf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15220.1 for Design Pressure Ratings,any FL15220 R1 AE Eval 15220.1.pdf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15220.2 b. Smooth/Wood 6'8"Non-Impact"Glazed Fiberglass Single Door with"Non- Grain/Rustic/Mahogany Series N Impact"Sidelite-Inswing/Outswing(OX or XO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15220 R1 II_Inst 15220.2,pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15220.2 for Design Pressure Ratings,any FL15220 R1 AE Eval 15220.2.odf additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 15220.3 rG Smooth/Wood 6'8"Non-Impact"Glazed Fiberglass Single Door with"Non- rain/Rustic/Mahogany Series N Impact"Sidelites-Inswing/Outswing(OXO-Configuration) berglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15220 R1 II Inst 15220.3.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15220.3 for Design Pressure Ratings,any FL15220 R1 AE Eval 15220.3.pdf additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 15220.4 d. Smooth/Wood 6'8"Non-Impact"Glazed Fiberglass Double Door- Grain/Rustic/Mahogany Series N Inswing/Outswing(XX-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15220 R1 II Iris 15220.4.pdf Lyndon Approved for use outside HVHZ:Yes Verified By: Lyon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15220.4 for Design Pressure Ratings,any FL15220 RI AE Eval 15220.4.1)df additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 15220.5 e.Smooth/Wood 6'8"Non-Impact"Glazed Fiberglass Double Door with"Non- Grain/Rustic/Mahogany Series N Impact"Sidelites-Inswing/Outswing (OXXO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15220 R1 I1 Inst 15220.5.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 https://www.floridabuilding.org/pr/pr—app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZ 1 Q... 7/29/2016 Florida Building Code Online Page 3 of 4 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15220.5 for Design Pressure Ratings,any FL15220 R1 AE Eyal_]5220.5.pdf additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 15220.6 f.Smooth/Wood 6'8"Non-Impact"Opaque Fiberglass Single Door- Grain/Rustic/Mahogany Series N Inswing/Outswing(X Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15220 R1 II Inst 15220.6.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15220.6 for Design Pressure Ratings,any FL15220 RI AE Eval 15220.6p df additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15220.7 g. Smooth/Wood 6'8"Non-Impact"Opaque Fiberglass Single Door with"Non- Grain/Rustic/Mahogany Series N Impact"Sidelite-Inswing/Outswing(OX or XO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15220 R1 II Ins',IS220.7.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 15220.7 for Design Pressure Ratings,any FL152.20 R1 AE Eval 15220.7.odf additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 15220.8 h.Smooth/Wood 6'8"Non-Impact"Opaque Fiberglass Single Door with"Non- Grain/Rustic/Mahogany Series N Impact"Sidelites-Inswing/Outswing(OXO-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15220 R1 II Inst 15220.8.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15220.8 for Design Pressure Ratings,any FL15220 RI AE Eval 15220.8.pdf additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 15220.9 i.Smooth/Wood 6'8"Non-Impact"Opaque Fiberglass Double Door- Grain/Rustic/Mahogany Series N Inswing/Outswing(XX-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15220 R1 11 Inst 15220.9.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 15220.9 for Design Pressure Ratings,any FL15220 R1 AE Eval 15220.9.pdf additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 15220.10 j.Smooth/Wood 6'8"Non-Impact"Opaque Fiberglass Double Door with"Non- Grain/Rustic/Mahogany Series N Impact"Sidelites-Inswing/Outswing (OXXO- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL1522.0 R1 11 Inst 15220.1.0.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15220.10 for Design Pressure Ratings, FL15220 RI AE Eval 15220.10.pdf any additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 15220.11 k.Smooth/Wood Grain Series N 8'0"Non-Impact"Glazed Fiberglass Single Door- Fiberglass Door Inswing/Outswing (X-Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15220 R1 1I Inst 1220.11.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15220.11 for Design Pressure Ratings, FL15220 RI AE Eval 15220.11.odf any additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 15220.12 I. Smooth/Wood Grain Series N Fiberglass Door https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yV VKJZ 1 Q... 7/29/2016 Florida Building Code Online Page 4 of 4 • 8'0"Non-Impact"Glazed Fiberglass Single Door with"Non- Impact"Sidelite-Inswing/Outswing(OX or XO- Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15220 R1 II Inst 15220.12.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15220.12 for Design Pressure Ratings, FL15220 R1 AE Eval 15220.12.Ddf any additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 15220.13 IT.Smooth/Wood Grain Series N 8'0"Non-Impact"Glazed Fiberglass Single Door with"Non- Fiberglass Door Impact"Sidelites-Inswing/Outswing(OXO-Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15220 R1 II Inst 15220.13.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15220.13 for Design Pressure Ratings, FL15220 R1 AE Eval 15220.13.odf any additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 15220.14 n.Smooth/Wood Grain Series N 8'0"Non-Impact"Glazed Fiberglass Double Door Fiberglass Door Inswing/Outswing(XX-Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FI-15220 RI II Inst 15220.14.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15220.14 for Design Pressure Ratings, FL15220 RI AE Eval .15220.14.12df any additional use limitations, installation instructions and Created by Independent Third Party:Yes product particulars. 15220.15 0. Smooth/Wood Grain Series N 8'0"Non-Impact"Glazed Fiberglass Double Door with"Non- Fiberglass Door Impact"Sidelites-Inswing/Outswing(OXXO- Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15220 R1 II Inst 15220.15.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 15220.15 for Design Pressure Ratings, FL15220 RI AE Eval 15220.15.odf any additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: u K9 0 Credit Card - safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZl Q... 7/29/2016 ( plastpro 37.60'MAXOVERALL _• 5200 W.CENTURY BLVD. FRAMEWIDTH LOS ANGELES,CA 90045 fid• Jz� Smooth/Wood Grain/White Wood Grain Rustic/Mahogany Series N Fiberglass Doom m a a INSWING/OUTSWING "NON-IMPACT' !R o a GENERAL NOTES '^ i uo m 1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code (FBC)structural requirements inducting the Ifigh Velocity Hurricane Zone(WHZ). e° zo o z Ov y GW 2: Product anchors shaft be as listed and spaced as shown an details.Anchor embedment to base material shall be beyond wall dressing or stucco. > s O rcw O 3. When used In ihe'TiVHP this product Is required to be protected with an impact resistant covering that compiles with Section 1626 of the FBC. m $ o a 4. When used in areas outside of the°HVHr requiring wind bome debris protection this product is required a to be protected with on impact resistant covering that complies with Section 1609.1.2 of the FBC. m 5. For NOW framing construction,anchoring of these units shall be the some as that shown for 2x buck masonry construction. JI_L 6. Site conditions that deviate from the details of this drawing require further engineering anohZsis by a licensed engineer or registered architect. � o 7. Outswing configurations meet water Infiltration requirementsfor'91VHP. i n & Inswing configurations do not meet the wafer InTiration requirements for the 1WHr.Inswing units shah be installed only in nonhobitable areas or at habitable locations protected by an overhang or canopy S such that the angle between the edge of canopy or overhang to A Is less than 45 degrees. s TABLE OF CONTEIM W SHEET It DESCBBri10N o 1lWccd eievafron,design pressures,&general notes 2 Door panel dehn8and glazing detail OVFoetr ='OVERALL ^�ESLGNPRESSURE S 3 Horwrsidvosssections .FRAME =b LO - GLASS -- -02120112 _ 4 Vertical a ass sections ` 'EYPE ..--' sum: N.T.S. ` tt DIMENSION DIMENSION-- POSrtIVE 7 NEGATIVE.= 5 Buck and home ancfrorirg-2)(buck masorsy construction - — _ _ - arm er: JK i 6 Frame anchoring-1X buck masonry wrshuctlon nuc rrc: LFS 3 7 BM of materials&components 37.5^X 81.63^ 20.50~X 6275^ GI +50.0 -50.0 muxwo xo; s FL-75220.1 4rm 1 rr 7 G 0.1 lents Dlas RMAN G - G- 79.25MAX.DOOR PANEL HEIGHT 62.75 MAX.D.L.O.HBGHT yy NN 0� W S 4 11.5 O.C.PP.) G T �_� 4---l.sv°---I ry N N O A IF r 41 H -H S oss r. z O O 00 m� 12 88 1= R Ta 1 o N r A .1r N Gal NA N ,NG zz Z p V,••"�yCElM9•••�' i A No.43/09 Di' R 4 PRODUCT: Dooumenb Pnparad 0Y•�� ` Lm F.S.Kt ,ldti .. •� fl. FIBERGLASSPLASTPRO INC. P.E.No.43409 to�, 2 N 1111111 $ N y O PART OR ASSDABLY: �/{ BUILDING CONSULTANTS.INC. I� p jl N,� 1 1 ZZ 15 DATE iD SRI ED. 201{ TBC JK ✓ PBox 230.Vold—FL 33595 ti 1 DATE BY DOOR PANEL DETAILS P.O.h...No.:813.059.9197 REVISIONS AND GLAZING DETAIL MPE C.&No.9813 O a012 9.w.eui�omo GONeu�eANra I..a. { 0.\OkAm\llastcm,Inc PERMANEN Flaida Pred— orals R-1523 C-Dnawln s Curren 8.15220.1-5. 1-3 Sm 'q O � � I V W� � O $ O V 2y 040 a�n O m is z "a a A A N 2 [s] w w W N W W ^+ A � N Z. N �O X �> o Go W N 0 A JJ00 Z O A ° Z 0 0 Lr No.43908 77aJ'+ 4 PRODUCT: Doaummb Pnpond i�- Lyndon F.SONmldt '• •'• N PLASTPRO INC. P.E.No.43409 lu N 3 2 N FlBERCLASS D '3jT2/11111111\ Q N ti O PART OR ASSEMBLY: s� BUILDING CONSULTANTS,INC. L p y jR fA\ f 4 22 7s UPDATE TO STN ED. zOla FBc UK HORIZONTAL CROSS SECTIONS Y!A P.O.BoN v0,Volrleo.FL 33595 I" rs ND DATE BY Pnono No.:513.559.9197 REVISIONS FBPE CA No.9813 m aGr2 w.w.eu��on.o co..au�.ww.e Iwo. - malems\w.:rom.mc P¢Rn}ANENnnonm swan APpmr+lAN.-u22mc-Or,.,hB,�cwrennT�•Ts2zo.t-sd�.B T.a EMS.MP.) A W a �o g z g I Q N V � O �A o •P m m t-0Id'MiN. EMS.(TYP.) A KN EMS.(TYP.) . m m (^mO V Ce i � '. • 1-I!d'MIN. 0 EMS.PP.) z < ` No.43408 ' yQT 4I PRDQUC. f R Lyndon F.SCh W �i� :pp�•` r'1 N P(RSTPROwT+Da N�,E���h w "Sm—OIASS DOOR AJN15.INC,�1 +� BUILDINQ CONSULTANT"',INC. PART OR ASSEMSt `(y I^ NO N tJl } 4 22}5 QPOATE TO 5TH EO. 201 FSC .!K P.Q.Ba 230,Vold—FL 33585 NO DATE gy VERTICAL CROSS SEC770NS Phone573.55B.BiBT R ISIONS FBPE CA No.BB}3 O ao}2 w.w.euuo�..ca«suuT,....a ruv. �.+4-1 J=.^n ,zma D TYP.HEAD TYP.HEAD 5 Z o•i i &JAMBS E &JAMBS E z m co MASONRY75 MASONRY 4, 5 OPENING OPENING E g.D FRAME z� O 2)(BUCK 7— io zz I 2XBUCK � � W INSWING 0 G a Yx N OUTSWING mm �m • _ TYP.®SILL BUCK ANCHORING SQUID:JAMB FRAMEANCHORING HINGE JAMB g Masonry 2X buck construction CONCRETEANCHOR NOTES: m _ I.Concrete anchor locations of the toners maybe adusfed to maintain the min. edge distance to mortar joints. 2.Concrete anchor focations noted as•MAX.ON CENTER"must be adjusted to S ° maintain the min.edge distance to mortarjoints,additional concrete anchors may be required to ensure the MAA)(ON COWER"dimension are not exceeded. _ 3 Concrete anchor table 9 n W i o .'.`. MIN.CLEARANCE::MIN CLEARAHEE 49 M K ANCHOR'.ANCHOR MIN:_ TYPE SIZE; EMBEDMEM TO INASONRY `TOAD.... : '-'EOGE .ANCHOR 10ITW ±z TAPCON® 1/4 1-1/4" 2" A" 02/20/12 N.T.S. W ELCOZ� vxc.ar: JK s ULTRACON 1/A" 1-1/�' 1" A" aa.ar: LFS ; WOOD SCREW INSTALLATION NOTES: Du—x s' I.Maintain a minimum 5/W edge distance,I"end distance,8 I"o.c.spacing of LATCH i DEADROLTDETAIL HINGE DEUR FL-15220.1 wood screws to prevent the splitting of wood. ° sHar S a 7 O E i Q'i d 0 is"moo 28 V m o 10 27 D G 11 &�aMes Y $ MASONRY mo OPENING U1CN i DEADBOLT DETAIL ?o HINGE DEVIL FRAME am x 1 1X BUCK g yS v U 1 INSWING _O 11 N OUTSWING N CONCRL7EANCHOR NOTES: IYP.@ SILL Z 1.Concrete anchor locations at the comers may be adjusted to maintain the min. D edge distance to modarjofnts. N 2 Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to a maintain the min.edge distance to modarJoinh,additional concrete anchors may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. " -• $ 3.Concrete anchor fable: SMILE JAMS FRAMEANCHORING HINGEJAMB 8 ANfNOR ANCHOR MfM MIN;_c[EpRANCE..:MIN CLEARANCE Masonry IX buck construction _ - 70,MASONRY TOADJACENT TYPE SRE_1 EM9ELTMEM .;:EDGE 1.ANCHOR 11 ITW 4"1/ 1-1 T TAPCON® /4" 4 'o iELCO 1/4" 1.1/4" 1" 4' —02/20/12 ULTRACON@ - ITWsaac: N.T.S. - TAPCON® 3/16' 1-1/4" 3" 1-1/7 owc.ar: JK p aa.er: LFS ; WOOD SCREW INSTALLATION NOTES: auewc rm< 1.Maintain a minimum 5/8"edge distance.1"end distance,i 1"o.c.spacing of FL-15220.1 owood screws to prevent the splitting of wood. �'� 8 2 O BHI OF MATERIALS IA.:''..•.. n 11FM• DEscR11ROH 6u1EUAL A 1X BUCK SG>=055 WOOD B Z(BUCK SG>=055 WOOD 1H','j ' C 1/4"MAX.SHIM SPACE - ^ �y:•., Y.�' z m D Ile X 2-3/4"ELCO OR ITW CONCRETE SCREWyTEg I-^ 4.56"MASONRY- �-I �•.; ;' D_0 0 E 301 OR HOLLOOW BLSOCK COONFORMING TO ASTM CONFORMINGNCRETE TO ACI CONCRETE E�11 I 11*lq o U H.°,m z° G 3/16"X3-1/4"PFH HW CONCRETE SCREW STEEL ti�Em zmco H 1/4"x3-1/4"PFH ELCO OR IIW CONCREE SCREW STEEL I I nvgoa� I 1/4"X2-I/4"PFH ELCOOR IIW CONCRETE SCREW STEEL h h�236"�i 1^ E 3 J 1/4"X33/4"PFH ELCOOR IIWCONCRETE SCREW STEEL K #9X2-1/2'PFH WOOD SCREW STEEL 2n H¢Aoa90E gEg o� �� L #8 X 2-1/2"PFH WOOD SCREW STEEL M #8 X 7 PFH WOOD SCREW STEEL N 1/4"FORxE5/4"PFHIIWCPPING BE SCREW STEEL L�4.56" -j n 7 FORCE 5 WEATHERSTRIPPING BY ENDURA J 8 COMPRESSION WEATHERSTRIP QLON 650 BY SCHLEGEL o v, 9 4"X 4"BUTT HINGE STEEL - ?o �� 10 #9 X 3/4"PFH WOOD SCREW STEN o'er io 11 #9X3/4"PFH WOOD SCREW STEEL 20 FINGER JOINTED PINE FRAME,HEAD&HINGE JAMBSWOOD 244 21 POLY FIBER JAMB COMP./VINYL n 7 m 27 LATCH STRIKE PLATE STEEL 21 HEAD 81,101. o 28 DEADBOLT PLATE STEEL Po1v fil�arm 29 OUTSWING THRESHOLD BY DLP ALUM./WOOD 30 INSWING VINYL DOOR BOTTOM SWEEP VINYL _ 4.56• n m 33 INSWING ADJUSTABLE ALUMINUM THRESHOLD BY DLP ALUM.l WOOD 40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS - 41 DOOR SKIN(MIN.0.069"THICK)BY PLASTPRO FIBERGLASS 42 TOP RAIL CELLULAR PVC 6 43 LATCH&HINGE STILE CELLULAR PVC H N 45 BOTTOM RAIL CELLULAR PVC ;8 c o 46 POLYURETHANE FOAM BY PLASTPRO POLYURETHANE (,- ADJUSTABLE INSWING IHRESHOLD 49 LATCH AND HINGE STILE REINFORCEMENT WOOD 50 LOCK BLOCK(2(rX 1.385') WOOD S' 3 65 ODL LTTE FRAME POLYMER 66 PF1200 P/MERIC FOAM 67 SCREW PLUG POLYMER 68 #8 X W PL PFH SCREW STl$ Ei4ji m e w i 69 GLAZING COMPOUND-FOR ODL BY ADCO BUTYL «o ^z �LOUTSNTNG IHRESNOID aY01f arE 02/20/12 - �J scuF: N.T.S. _ JK auc er: LFS ; owmxc r+a s' Fl.-15220.1 °n = air 7 or 7 O