Address: 2822 THREE WOOD DR - PORT ST LUCIE, FL 34952
Legal Description: LINKS AT SAVANNA CLUB (PB 40-39) ELK 37 LOT 13 (OR 3727-85).
Property Tax ID #: 3425707-0113-000-9 Lot No.
Site Plan Name: Block No.
Project Name:
Setbacks Front Back: Right Side: Left Side:
DETAILED DESCRIPTION OF WORK:
REPLACE FAILED ELECTRIC WATER HEATER IN CLOSET WITH AO SMITH 30 GAL ELECTRIC
WATER HEATER.
CONSTRUCTION INFORMATIONS`
Additional work to t(p�b�2MbNneo unaertnis permit- ell tIn apply
I :
[=MVAC L IGas Tank E]Gas Piping LJ Shutters ❑Windows/Doors
11 Electric ❑✓_Plumbing Sprinklers 0Generator Roof
Total Sq. Ft of Construction:
Cost of Construction: $ 975.00
DOWNER/LESSEE
St Ft of of First Floor:
Utilities:n Sewer OSeptic Building Height:
Name Robert E 8 Barbara A. LEATHERS
Address: 2822 Three Wood Dr
City: Port St Lucie State: FL
Zip Code: 34952 Fax: nia
Phone No. 772-631-7988
E -Mail: n/a
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
CONTRACTOR:
Name: Robert W. LUDLUM
Company: Benjamin Franklin Plumber
Address: 1631 SW South Macedo Blvd
City: Port St Lucie State: FI
Zip Code: 34984 Fax: 772-871-9069
Phone No. 772-871-9494
E -Mail: pennits@benfranklinplumbeccom
State or County License: CFC1426801
If value of construction is $2500 or more, a RECORDED Notice of !am mencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER:
Name:
Address:
City:
Zip: Phone:
FEE SIMPLE TITLE HOLDER:
Name:
Address:
City:
Zip: Phone:
Not Applicable
State:
Not Applicable
MORTGAGE COMPANY:
Name:
Address:
City:
Zip: Phone:
BONDING COMPANY:
Name:
Address:
City:
Zip: Phone:
I certify that no work or installation has commenced prior to the issuance of a permit.
�i
Not Applicable
State:
_Not Applicable
St. Lucie Counttyv makes no representation that Is granting a permit will authorize the ermrt holder to build the subject structure
which is in conFlict with any applicable Home Owners Association rules, bylaws or an covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. I you intend to obtain financing, consult with lender ora attorney before
commencing woeoTrreour NoticeofCommeicement. //s 5 u �`of CorOarlcenoHolder
STATE OF FLORIDA r STATE OF FLORIDA,�.,y''
COUNTY OF Co�cO/C COUNTY OF e'
The for in inr
wled ed'4efore me The for ing insiru nt was acknowled ed before me
this day o. 20�by this�4pe,
2�i .2ps�by
,i(Name of perso (Namnowledging )
ISure of u iic-S'ate o Florida) (Signature ary Pu'i»� aI
Personally Known 'UMXroouceo slim LL00t Personal nown ✓ R�� uce ery IAM1 YAIWt
Type of Identificatrion /Pr Type o are cation Pr ipik . xrn. a otpo
io% commisvan FF 96166 �,p� ) Commission a FF 961661
Commission Na. .` My Coi W&P,nF 1May9 6,1010 Commission N6. C y 1dp My C{501811 pireF May 5.11
IanQI616mu6p NFliona Xary AtFL ��' 9onCediMouyl MFlpna N6lryA
Revtsed 07/15/2014
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE
COMPLETE
INITIALS
Ce Smith. Residential Electric
Water Heaters
ENHANCED HEATING ELEMENTS
• Dual 4500 watt elements for fast recovery
and reliable operation."
• Incoloy stainless steel lower element lasts
longer than a standard copper element.
DYNACLEAN" DIFFUSER DIP TUBE
• Helps reduce time and sediment buildup
and maximizes hat water output Made
from long-lasting SEX cross-linked
polymer.
HIGH ENERGY FACTORS
• Eco -friendly non -CFC foam insulation,
heat traps and other features combine
to yield a higher Energy Factor that
maximizes savings on operating costs.
COREGARD" ANODE ROD
• Our anode rods have a stainless steel
core that extends the life of the anode
rod allowing Superior tank protection far
longer than standard anode rods.
BLUE DIAMOND- GLASS COATING
• Provides superior corrosion resistance
compared to industry standard glass
lining
ENHANCED -FLOW BRASS DRAIN VALVE
• Our residential water heaters have a solid
brass, tamper resistant, enhanced -Flow,
ball type, drain valve.
• Uses a standard female hose fitting that
allows for fast and easy draining during
maintenance.
• Designed for easy operation, this valve
includes an integral screwdriver slot that
features a V4 turn (open/close) radius,
which not only permits full straight -
through water flaw but also a quick and
positive shut off.
'Madel ENL -20 bas asmgleekmem
CODE COMPLIANCE
• Meets UBC and ICC National Codes and
listed with CEC.
• Complies with the Federal Energy
Conservation Standards effective
April 16, 2015, in accordance with the
Energy Policy and Conservation Act
(EPCA), as amended
APPROVED FOR MANUFACTURED
HOUSING
• All residential electric water heaters are
compliant with HUD Standards for mobile
homes/manufactured housing.
CERTIFIED TO UL 174 FOR HOUSEHOLD
ELECTRIC WATER HEATERS
CSA CERTIFIED AND ASME RATED T&P
RELIEF VALVE
DESIGN -LISTED BY UNDERWRITERS
LABORATORIES
• Certified at 300 psi test pressure and 150
psi working pressure.
• Listed according to UL 174 standards
governing storage tank type electric water
heaters.
6 -YEAR LIMITED TANK AND PARTS
WARRANTY
• For complete information, consult written
warranty or go to hOtwdteLCom.
®Marchi 2016 A O. Smith COT corm All nghts meerved Fre,1 d
en w.M1otwate[mm I SM 537-1953 Toll Free USA I0. 0. Smith COrporafwn 1500 Tennessee Walh Parkway IAshland CXg TN 37015 MSRE50602
Residential Electric
Water Heaters
T&P VALVE -'�•-
ACCESS
PANEL
I
t- C � B A C
ACCESS
PANEL
DRAIN
VALVE
Dimensions in Inchesppprox99.
EirsY Hour
Recovery ®
ii
Element Wattage 240V
Model
Gallon
Rating
Energy
Rlse
I 8
0
Number
Capacity
Gallon
19
EaRor
Gallon Per
Standard
( Maximum
118 I
6blld
51-114
21
131 I
Hour
51-114
22
I Tall Models
56-18
4818
24
145 I
ENT gift
3'1
20
95 I
C 95
30 L2
4500
6000
ENT411
40
51
109
095
21
4500
6000
ENTB-50'
50
]0
65
0 95
21
4500
60M
1 ENT -501
50
71
115 I
095
21
4500
6000
I ENT -551
55
76
Ila 1
0.94
I Z1
4500
6000
I Short Mode s
-
ENS" 30- 30
48
095
21
4500
6000
I ENS -301 30
49
095
ZI
4500
6000
1 ENS -40t 40
55
0 95
21
4500
6000
I ENS -501 50
62
0 95
➢
4500
6000
11II
I Losvb9y Totfonneat Mo els
ENL_ Q 19 5
N/A
N/A
21
4500
6000
1 ENLB-30' 28
40
095
21
4500
6000
I ENL -301 28
43
095
21
4500
6000
I ENLB-00' 38
46
095
21
4500
6"
ENL -401+ 38
44
0.95
21
4500
6000
I ENLB-SOY 48
57
095
21
4500
6000
Male 314' water connections on B• anter
•Models sFlpw4h supplietl msulatlon blanket.
Mr 10 Mr tank and 6 year pans wamnly,change 'E' to"
P" in the model number levample
ENT 3D becomes EST 30).
♦ Top THP can nm available oo he model
ENL 20 a single shoont a,fi,u,.,aO cnfy
Olnronal tops&Plara0on p21s usetl on lM1e ENf 50. fN]B50,EM-SS,
MS
40 mtl ENS 50
OWronal tppl&Plamrmn X3 is used on the ENka-50
Topi is notavailable on the l0 gar model MILE 50
Dimensions and specifications subleet to Orange orhout hours In matters
with ow polity of
oran ous Product
wevemenl
T&P VALVE -'�•-
ACCESS
PANEL
I
t- C � B A C
ACCESS
PANEL
DRAIN
VALVE
ANODE (OR OPTIONAL
r TOPT&P LOCATION #1)
/OPTIONAL TOPT&P
r LOCATION #3
OPTIONAL TOP T&P
LOCATION #2
OO O QO�JUNCTION
BOX
T&P VALVE
mss.. - estw.u.•mno.uuharin.u..-iy..r n.`..1.1�rah. �ok+�13m. .nnh.hnrole�
SWi 3016 A.0 Smit CcrporatlOn AlIrights res rd Pon, 2o•3
www.M1olwatecmm 100013]-1953loll free USA AOSRE50602
Dimensions in Inchesppprox99.
A
I 8
0
( Weh9hilllbsl
46-12
119
19
fll
9, 1
60-I14
53114
20
118 I
6blld
51-114
21
131 I
6PIIZ
51-114
22
134 I
56-18
4818
24
145 I
39
30 1/2
20
95 I
39-314
30 L2
22
94
50
40 3/4
10-1/2
109
49 3l4
40 3/8
23
161
30
21-114
20
65
30
21-314
22
96 I
31-114
21-314
24
115 I
31-314
24
24
118 I
33-112
24
26
Ila 1
34
25
261/2
172 1
ANODE (OR OPTIONAL
r TOPT&P LOCATION #1)
/OPTIONAL TOPT&P
r LOCATION #3
OPTIONAL TOP T&P
LOCATION #2
OO O QO�JUNCTION
BOX
T&P VALVE
mss.. - estw.u.•mno.uuharin.u..-iy..r n.`..1.1�rah. �ok+�13m. .nnh.hnrole�
SWi 3016 A.0 Smit CcrporatlOn AlIrights res rd Pon, 2o•3
www.M1olwatecmm 100013]-1953loll free USA AOSRE50602