ASCE 7-10&FBC 2014 5th Edition ENCLOSED BLDG X SEMI ENCLOSED BLDG OPEN=
PART LOW RISE C&C SIMPLIFIED
RISK CAT 2/V--ILOJEXPOSUREJKzt- 1.0/h=ji7/ -J12 PITCH/MEAN PARAPET ht
ROOF SYSTEM Iz NOA_ 6 4- SZR,G
ZONE 1 B @ h=30 = X = PSF x 0.6
ZONE 2 B @ h=30 = X = PSF x 0.6=-4&'4'
ZONE 3 B @ h=30 = X = PSF x 0.6= .P a= 3' Z 3'
MAX DESIGN PRESSURE PER NOA �2•`�
DECK TYPE QL%-L WOO O THICKNESS_01,3 Z t, 1 W.
BASE SHEET ALL- NO.OF PLIES I
FASTENERS B648ENG LL. 4A•i2,51_W rt�nrttUl+
/ f.IJ4_ t 0 GAPS
FASTENER SPACING FOR ANCHOR/BASE SHEET ATTACHMENT:
Field"oc @Lap,#Rows_ @8"oc Perimeter:$"oc @Lap,#Rows 3__@_4L_"oc Corner: "oc@Lap,#Rows oc
INSULATION BASE LAYER TYPE SIZE
TYPE OF FASTENERS/OR BONDING MATERIAL ^^
INSULATION TOP LAYER TYPE SIZE
TYPE OF FASTENERS/OR BONDING MATERIAL
NUMBER OF FASTENERS PER INSULATION BOARD: Field- Perimeter -- Corner
PLY SHEET NO.OF PLIES ^ TYPE OF FASTENERS/BONDING
TOP PLY FucsT t ks rit, 6A NO.OF PLIES A TYPE OF FA&TE+4E-RS/BONDING -roe_61A
2.6-"PA W H m a
9- osf
T reasure Harvey E. Koehnen
C oast Professional Engineer#32831
B uilding Architect#AR0009471
E ngineers, Certified General Contractor#CGCO24776
Inc.
These tables Are For Roof'Coverings
Roof coverings Installed on Buildings With a
Mean Roof Height of 30'or Less Located In Exposures B, C or D
'Table 8301.2[21_.O�- P 0,siu AS---Eff 7-tom
COMPONENTS AND CLADDING WORST CASE DESIGN PRESSURE TPSF].
160Exp B 16OExp G 16oExp C 16OExp D 160Exp D
(One story (TWO story*) (One story')(Two story*)
-FRoof>0 to7degrees Zone 1 -27.6 -33.4 -38.7 _40.6 -45.9
Roof
rees=11 Z(
7degrees=1112112 pitch Zone 2 -46.4 -56.2 -65.0 -68.3 -77.1
Zone 3 9.8-6 -84 -97.7 -102.7 -115.9
Roof>7 to 27 degrees Zone 1 -26.3 * -30.7 -35.5 -42
27 degrees=6/12 pitch Zone 2 -44,1 -63.4 -61.8 -64.9 -73.3
Zone 3 -65J -78.8 -91.2 -95.7 -108::1
Roof>27 to 45 degrees Zone 1 -27.8 -33.7 -40.0 -40.1 -46:2
2
45 degrees= 12112 pitch Zone 2 - -32.4 -39.3 -45.4 -47.7 -53.8
Zone 3 -32.4 -39.3 -45A -47.7 -53.8
.160 Exp B 15OExp C 150Exp C J50Exp D 160 Exp D
(one story*) (tvvo story*) (one story*) (two story)
Roof>0 to 7 degrees Zone 1 -24.3 -29,6 -34.1 -35.8 -40.4
7degrees=11/2112 pitch Zone 2 -40.8 -49A -57.2 -60-0 -67.8
Zone 3 -61.4 -743 -86.0 -90.3 -102.0
Roof>7 to 27 degrees Zone 1 -22,2 -26.9 -31.1 -32.7 -36.9
27 degrees=6/12 pitch Zone 2 -38.7 .-46.0 -54.2 -56.9 -84.3
Zone 3 -57,3 -69.4 -B0.3 -843 -95.2
Roof>27 to 45 ftrees Zone 1 -24.3 L29.5 -34.1 -85.8 -40.4
45 degrees=12/12 pitch Zone 2 -28.4 -34.4 -39.8 -41.8 -47.9
Zone 3 -28.4 -34.4 -393 -41.8 -47.2
One story*=one story building with a maximum mean roof height of 15 feet
lWo story*=two story building with a maximum mean roof height of 30 feet
If-allowed by the Miami Dade N.O.A or Florida Product Approval., any system-that does.-not meet the
M111111num components and cladding pressures for the area that the building Is located per this form
may require a Florida licensed engineer to revise the fastener spacing