HomeMy WebLinkAboutProduct Approval MIAMmanum bELAM-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) %"v-4v_miarnidade_Lrov/econornv
CertainTeed Corporation
18 Moores Road
Malvern,PA 19355
SCOPE:
This NOA is being issued-under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below-The Miami Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks.
LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement:"Miami-Dade County Product Control Approved%unless otherwise noted herein.
RENEWALof this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA_Failure to comply with any section
of this NOA shall be,cause for termination and removal of NOA.
ADVERTISEMENT: 0 by
The NOA number preceded by the words Miami-Dade County, Florida, and foll wed- the-h—
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,tlieh,_it.'6hal1_be:done
in its entirety. i
INSPECTION:Acopy of this entire NOA shall beprovided to the user by the manufacturer or its.dfM!'6u-tor§_and-,.
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA#14-0224.03 and consists of pages I through 42.
The submitted documentation was reviewed by Alex Tigerq.
NOA No.-.444520.02
MIAMWMECOLIPM
Expiration Date., 06/19/18
Approval Date: 09124/15
Page 1 of 42
Membrane Type: APP Modified
Deck Type 11: ood,Non-Insulated
Deck Description: 1
V/W.9132"or greater plywood or wood plank
v/SystenType E(3); Base shoot mechanically fastened
All General and System Limitations apply.
Base Sheer. One ire Base Spee osemite Venting Base Sheet Flexiglas Base
Sheet,Fli�tlasti----cccc- o y S astic Ultra Poly SMS Base Sheet,Glasbase Base
Sheet or Ffintglas Premium Ply Sheet Type VI mechanically attached as detailed below.
�a
5fip--ir�ese�Shee
P—or�—T&,M—RWSftmt-l�
Fastening: Base sheet shall be lapped 47 and fastened with I I ga-annular ring shank nails and approved tin
caps 8"o.c.in the lap and three rows staggered in the center of the sheet 8"O.C.
Ply h t: One ply of'All Weather/Empire Base Sheet Flintlastic Ultra Poly SMS Base Sheet Glasbase
(0 'on Base Sheet Flexiglas Base,Sheet,Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one,
or more plies of Ffintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in
fall mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq.
or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic
STA or Flintlastic APP Base T torch adhered.
Membrane: f FlintlasticGT Flintlastic GTA CoolStar,Flintlastic GTA-FR or Flintlastic GTA-FR CoolStar
torch adhered to baselply sheet.
�urfaci4: Any of the approved surfacing/coating options listed in Table 4.
nal)
�101
Maximum Design -52.5 psf.(See General Limitation 47)
Pressure:
NOA Na-t 14-0929-02
MLAMWADECOUNWY ExpirationDatet 06119/19
Approval Date: 09124115
Page 23 of 42
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub-Catepory: Modified Bitumen
Material: APP/SBS
Deck Type: Wood
Maximum Design Pressure: 427.5 psE
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT:
TABLE I
Test Product
Product Dimensions Specification Description
Z,Weather/Empire Base 39'/g"x 65'10"; ASTM D 4601,Type Asphalt coated,fiberglass reinforced
Sheet Roll weight: 70 lbs. il base sheet.
(2 squares) UL Type G2
Flexiglas Base Sheet 39'/s"x 98'9"-*Roll ASTM D 4601,Type Modified Bitumen coated fiberglass
weight:90 lbs. Id base sheet.
(3 squares) UL Type G2
Flintlastic Base 20 393/81,x 49'6";Roll ASTM D 6163, ' Modified Bitumen coated fiberglass
weight:90 lbs. Grade S,Type I base sheet.
(1.5 squares)
Flintglas Ply Sheet Type IV 39 318"x 164'7";Roll ASTM D 2178,Type Fiberglass,asphalt impregnated ply sheet.
weight 38 lbs. IV
(5 squares) UL Type GI
Flintglas Premium Ply Sheet 39 /s"x 1647';Roll ASTM D 2178,Type Fiberglass,asphalt impregnated ply
Type V1 weight:40 lbs, V1 sheet.
(5 squares) UL Type GI
Flintlastic STA 39'/8"x 32' 10";Roll ASTM D 6222, Smooth surfaced APP Modified
.............. weight-87 lbs. Grade S,Type I Bitumen membrane with non-woven
(I square) polyester mat reinforcement for torch
application.
Flintlastic GTA 39'/g"x 32' 10";Roll ASTM D 6222, Granule surfaced APP Modified
weight: 105 lbs. Grade G,Type I Bitumen membrane with non-woven
(I square) polyester mat reinforcement for torch
application.
Flintlastic GTA-FR 39?/,s"x 32' 10";Roll ASTM' D 6222, Granule surfaced APP Modified
weight: 105 lbs. Grade G,Type I Bitumen membrane with non-woven
(I square) polyester mat reinforcement for torch
application.
Flintlastic GMS 39'/8"x 32' 10";Roll ASTM D 6164, Granule surfaced SBS Modified
weight:94 lbs. Grade G,Type I Bitumen membrane with non-woven
(I square) polyester mat reinforcement for mop
application.
NOA No.: 14-0529.02
Expiration Date: 06/19/18
Approval Date: 09124/15
Page 2 of 42
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet
GENERAL LIMITATION&
I Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a fall mopping of approved asphalt applied within the
EVT range and at a rate 617 20-40 lbs./sq.,or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment- When applied in approved asphalt, panel size
shall be 4!x 4!maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6"break sball be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of 45 psL
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf,as
tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested,are below
275 lbf.insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing,
prepared,signed and sealed by a Florida registered Professional Engineer,Registered Architect,or Registered
Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value
taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application
Standard RAS 117.
17. Perimeter and comer areas shall comply with the enhanced uplift pressure-requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When -this limitation is specifically referred
within this NOA,General Limitation#9 will not be applicable.)
8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
9- The maxinnim designed pressure limitation listed shall be applicable to all roof pressure zones(i.e.field,
perimeters,and comers).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones(i.e.perimeters,extended comers and comers).(When this limitation is specifically
referred within this NOA,General Limitation#7 will not be applicable.)
10- All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.:14-0529.02
M"PDADEGOUiVT7 Expiration Date: 06119/18
Approval Date: 09/24/15
Page 42 of 42