60° X 80" RECEI V!p A.0 03 ?ol,6
REPLACE DOORS IN 1 OPENING ONLY.
OPENING HAS EXISTING HURRICANE PROTECTION PER
HOMEOWNER.SHUTTER PERMIT NOT MADE AVAILABLE.
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 60 80 33.33 1 4 35.1 1 -38.3 FL13541.4 50.0 1 -50.0 FAMILY ROOM-LSMI
U-FACTOR SHGC
FL13541.4 0.29 0.25
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH#10 WOOD SCREWS INTO WOOD STRUCTURE
WITH A MINIMUM 1 1/2"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 11 FT 4 IN
ZARAGOZA RESIDENCE
1007 CORAL STREET DOOR REPLACEMENT PLAN
FORT PIERCE, FLORIDA