HomeMy WebLinkAboutROOF - METAL (3) RECcI" D A-u-3 0 D ?616 Asmussen Engineering LLC. Engineering&Environmental Services P.O.Box 1998,Okeechobee,FL.34973-1998 Office:(863)763-8546 Fax:(863)467-8560 Memorandum Date: July 29, 2016 To: St. Lucie County Building Department 2300 Virginia Avenue Ft. Pierce, FL. 34982-5652 From: Loris C. Asmussen,P.E. Subject: Gregg &Barbara Henson 471 La Buona Vita Drive Port St. Lucie,FL. 34972 1985 VICT HS (40') Vehicle ID— FL10343 A/B This memorandum is provided to address re-roofmg of a 1985 mobile home. Proposed is Gulf Rib Roof Paneling(26 GA metal—FL 11651.22R1) as a replacement for the originally manufactured roof. Tamko Underlayment (30#ASTM D 226)will be used. Attached are product approvals for the paneling (#11651.22R1) and underlayment(FL12328-R2), which includes attachment methodology for the rib panels and underlayment. The panels are manufactured by Gulf Coast Supply&Manufacturing,Inc. The Engineer Evaluator of the paneling is Terrence E. Wolfe(FL. P.E.No. 44923) and the Validator is Locke Bowden(FL P.E.No. 49704). Based on my review of this proposed project, including product approvals and loads for which the above-referenced structure will be exposed to at this location in St. Lucie County(160 mph 3- second gust and exposure"C"),the project is found to be in substantial compliance with the 2010 Florida Building Code. Any plywood, found to be damaged or in disrepair,will be replaced and fastened in a manner similar or equivalent to that employed during manufacture of the original structure. Sincerely';.,— Loris C Asmussen�'.P E- ..Principle - o -C �. ag C: Henson(Port St. Lucie)