' Company: The Home Depor Q home Services Job Description: Replace 36 WindDand
Prepared By: Erick De Dios
Client Name: Liddell,Jack and Kim Project Number: 8196612 and 8288077
Version 10.0 -
.(c)2a12SiruetureslNernptional,LLG ti .,:. .••,. Conforms withA5CE7.16
DESIGN PRESSURES FOR WALL COMPONENTS&CLADDING
r
Design Data Building Data
t Wind Velocity(mph) 160 Nrean Roof Height 30 r
F Risk Category 2 Building Width(ft) 40
Exposure Category D Building Length(it) 60
Directionality Factor 0.85 Roof Slope (x:12) 6
Internal Pressure Coefficient+/- 0.18
Design pressures listed below are: Allowable Stress
OPENING OPENING LOCATION OPENING OPENING DIMENSIONS MAXIMUM POSITIVE MAXIMUM NEGATIVE
MARK DESCRIPTION .ZONE ELEVATION WIDTH(INCHES) HEIGHT(INCHES) PERSSURE(PSF) PRESSURE(PSF)
1 e window 5 5 24 28 45.8 6 761.4
2 Window 5 5 24 28 45.8 -61.4
3 ✓• window 5 5 24 28 45.8 -61.4
4 ✓ -----window- 5 5 40 62 -- 44.2 -58.1
5 ✓ window 5 5 40 62 44.2 -58.1
6 7 window 5 5 24 36 45.8 -61.4
7 window5 5 35 36 45.8 -61.4
8 window 5 5 52 .37 45.0 -59.6
9 ✓ r window 5 5 52 50. 44.1 -57.9
10V vOndo , 5 5 24 35 45.8 -61.4
it 7 window 5 5 52 50 44.1 -57.9
12/ window 5 5 24 35 45.8 -61.4
13✓.' window 5 5 52 50 44.1 -57.9
14 Of window 5 5 52 50 44.1 -57,9
15 Door 5 5 72 80 41.7 -53.1
16 window 5 5 34 38 45.8 -61.4
17 AC window 5 5 106 50 42.0 -53.6
18 jV window 5 5 36 35 45.8 -61.4
19 window 5 5 80 58 42.4 -54.4
20 window 5 5 48 60 43.8 -57.2
21. window 5 5 48 60 43.8 -57.2
22./' window 5 5 40 60 44.3 -58.3
23V window 5 5 40 60 44.3 -58.3
24 tr window 5 5 40 60 44.3 -58.3
25'4 window 5 5 40 62 44.2 -58.1
t ,
Width of End Zone(a)in feet=4
s h
s
a
r �t 4 R
5 5
ti AUG 0 2016
PEPi,/ilTfiNG
St- Lucie County, FL
USTRUCTURES INTERNATIONAL,LIC
5/25/2015 12:22 PM
• - ' Company: The Home Depof@,.Home services Job Description: Replace 36 Windows and 1
Prepared Ely: Erick De Dios
Client Name: Liddell Jack and Kim Project Number: 8196612 and.8288077
DESIGN PRESSURES FOR WALL COMPONENTS.&CLADDING
Design Data Building Data
Wind Velocity(mph) 160 Mean Roof Height- 30
Risk"Category 2 Building Width(ft) 40
Exposure Category D Building Length(ft) 60
Directionality Factor 0.85 Roof Slope (x:12) 6
Internal Pressure Coefficient+1- 0.18
Design pressures listed below are: Allowable Stress
OPENING OPENING LOCATION OPENINGOPENING DIMENSIONS. MAXIMUM POSITIVE MAXIMUM NEGATIVE
MARK DESCRIPTION ZONE ELEVATION :WIDTH(INCHES) HEIGHT(INCHES) PERSSURE(PSF) PRESSURE(PSF)
26V Windows 5 5 40 62 44.2 -58.1
27-/ Windows 5. 5 40 62 44:2 -58.1
28-/ Windows 5 5 40 62 44.2 -58.1
29✓ Windows 5 5 24 61 45.8. -61.3
30 Windows 5 5 24 .61 45.8 -61.3
31 Windows 5 5 40 62 44.2 -58.1
32 Windows 5 5 40 62 44.2 -58,1
33 f Windows 5 5 40 62 44:2 -58.1
34 ✓ Windows 5 5 40 62 44.2 -58.1
35 Windows 5 5 40 62 44.2 -58.1
36• Windows 5 5 40 62 44.2 -58.1
38 Windows 5' 5 40 62 44.2 -58.1
Width of End Zone(a)in feet=4
5 h
4 a.
Y i
�Q 5 5
STRUCTURES INTERNATIONAL.LLC
,..:�'f5»S�S:C^a�:t1&^S!��^..t'"'�C�r'tC:3M.1•
5/25/201512:43.TM