Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 6 r �t > ,,.,.>-a� ,g.,,�''i_ S _ Av�..t�R. P,a.4.y �sitii.�. E Rs NUJ.• "�, Fla i'6Di�artrrertI BCIS Home t Log In I User Registration i Hot Topics ! Submit Surcharge = Stats&Facts i Publications ` FBC Staff Business ' product Approval Professinal 034 4 USER: Public User Regulation Product Approval Menu > Product or Application Search > Application List>Application Detail FL# FL5012-R15 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR. Approvals by DBPR shall POC and/or the Commission if necessary. Comments Archived Product Manufacturer PGT Industries Address/Phone/Email 1070 Technology Drive Nokomis, FL 34275 (941) 486-0100 Ext 22318 druarkCa)pgtindustries.com Authorized Signature Jens Rosowski j rosowski@pgtindustri es.com Technical Representative Jens Rosowski Address/Phone/Email 1070 Technology Drive Nokomis, FL 342,75 (941) 486-0100 Ext 21140 jrosowski@pgtindustries.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications, Inc. Validated By Steven M. Urich, PE ,;A Validation Checklist- Hardcopy Received Referenced Standard and Year (of Standard) Standard AAMA 506 AAMA/WDMA/CSA 101/IS2/A440 AAMA/WDMA/CSA 101/IS2/A440 AAMA/WDMA/CSA 101AS2/A440 ASTM E1886 ASTM E1996 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGE... 7/17/2015 Florida Building Code Online Page 2 of 6 ASTM E283 ASTM E330 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 06/11/2015 Date Validated 06/19/2015 Date Pending FBC Approval - Date Approved 06/27/2015 Summary of Products FL# Model, Number or Name Description 5012.1 FCA - 440 Vinyl Fixed Casement Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5012 R15 C CAC 190-795CAR Approved for use outside HVHZ: Yes FL5012 R15 C CAC 190-796CAR Impact Resistant: No Quality Assurance Contract Exp Design Pressure: N/A 10/28/2015 Other: Please see the Installation Instructions for design Installation Instructions pressure, size and anchorage information. FL5012 R15 11 FCA-440.pdf Verified By: A. Lynn Miller, PE 587 Created by Independent Third Par Evaluation Reports FL5012 R15 AE FCA-440 Evaluat Created by Independent Third Par 5012.2 FCA- 540 WinGuard Vinyl Fixed Casement Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5012 R15 C CAC 190-2701CAI Approved for use outside HVHZ: Yes FL5012 R15 C CAC 190-795CAR Impact Resistant: Yes FL5012 R15 C CAC 190-796CAR Design Pressure: N/A Quality Assurance Contract Exp Other: Please see the Installation Instructions for design 10/28/2015 pressure, size and anchorage information. Installation Instructions FL5012 R15 II FCA-540.pdf Verified By: A. Lynn Miller, PE 587 Created by Independent Third Par Evaluation Reports FL5012 R15 AE FCA-540 Evaluat Created by Independent Third Par 5012.3 FCA - 640 Aluminum Fixed Casement Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5012 R15 C CAC CAPW-640 C Approved for use outside HVHZ: Yes Quality Assurance Contract Exp Impact Resistant: No 02/25/2019 Design Pressure:,N/A Installation Instructions Other: Please see the Installation Instructions for design FL5012 R15 11 FCA-640.12df pressure, size and anchorage information. Verified By: A. Lynn Miller, PE 587 Created by Independent Third Par Evaluation Reports FL5012 R15 AE FCA-640 Evaluat Created by Independent Third Par https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGE... 7/17/2015 Florida Building Code Online Page 3 of 6 5012.4 FCA-5440 EnergyVue Vinyl Fixed Casement M Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5012 R15 C CAC PW-5440 Ce Approved for use outside HVHZ: Yes Quality Assurance Contract Exp Impact Resistant: No 07/29/2018 Design Pressure:N/A Installation Instructions Other: Please see the Installation Instructions for design FL5012 R15 11 FCA-5440.pdf pressure, size and anchorage information. Verified By: A. Lynn Miller, P.E. 5E Created by Independent Third Par Evaluation Reports FL5012 R15 AE FCA-5440 EvaluE Created by Independent Third Par 5012.5 FCA-5540 WinGuard Vinyl Fixed Casement Wi Limits of Use Certification Agency Certificate. Approved for use in HVHZ: No FL5012 R15 C CAC PW-5540 Ce Approved for use outside HVHZ: Yes Quality Assurance Contract Exp Impact Resistant: Yes 08/12/2018 Design Pressure: N/A Installation Instructions Other: Please see the Installation Instructions for design FL5012 R15 11 FCA-5540.pdf pressure, size and anchorage information. Verified By: A. Lynn Miller, P.E. 5E Created by Independent Third Par Evaluation Reports FL5012 R15 AE FCA-5540 Evaluz Created by Independent Third Par 5012.6 PW- 220 Aluminum Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5012 R15 C CAC F-220 Certifi Approved for use outside HVHZ: Yes Quality Assurance Contract Exp Impact Resistant: No 10/24/2017 Design Pressure: N/A Installation Instructions Other: Please see the Installation Instructions for design FL5012 R15 11 F-220.pdf pressure, size and anchorage information. Verified By: A. Lynn Miller, PE 587 Created by Independent Third Par Evaluation Reports FL5012 R15 AE F-220 Evaluatior Created by Independent Third Par- 5012.7 ar5012.7 PW- 420 Vinyl Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5012 R15 C CAC F-420 Certifl Approved for use outside HVHZ: Yes Quality Assurance Contract Exp Impact Resistant: No 08/01/2017 Design Pressure: N/A Installation Instructions Other: Please seethe Installation Instructions for design FL5012 R15 11 F-420.pdf pressure, size and anchorage information. Verified By: A. Lynn Miller, PE 587 Created by Independent Third Par Evaluation Reports FL5012 R15 AE F-420 Evaluatior Created by Independent Third Par 5012.8 PW- 520 WinGuard Vinyl Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5012 R15 C CAC Certification! e HVHZ: Yes Quality Assurance Contract Exp Impact=Resista:nt-:;Ye:sf 08/15/2016 Desi Installation Instructions Other: Please see the Installation Instructions for design FL5012 R15 11 F-520.pdf pressure, size and anchorage information. Verified By: A. Lynn Miller, PE 587 Created by Independent Third Par Evaluation Reports FL5012 R15 AE F-520 Evaluatior Created by Independent Third Par https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGE... 7/17/2015 IMPACT-RESISTANT GENERAL.NOTES: 1)THE ANCHORAGE METHODS SHOWN ANCHOR LOCATIONS HAVE BEEN DESIGNED TO COMPLY WITH 8 SPACING THE FLORIDA BUILDING CODE FOR THE DESIGN PRESSURES LISTED. - MAX.BUCK 6"MAX. I 2" (i 2)WOOD BUCKS DEPICTED AS 1X ARE MAX.BUCK LESS THAN 1-1/2"THICK.1X WOOD BUCKS I I M i ARE OPTIONAL IF UNIT IS INSTALLEDfl —T DIRECTLY TO SOLID CONCRETE.WOOD } BUCKS DEPICTED AS 2X ARE 1-V2"THICK OR GREATER.ATTACHMENT METHOD OF WOOD BUCKS SHALL BE DONE BY OTHERS. 3)SEE TABLES FOR MINIMUM EDGE MAX, DISTANCE FROM CENTER OF ANCHOR TO MAX. MAX O.C. `( SUBSTRATE EDGE(EXCLUDING FINISH OR BUCK I srucco). � � BUCK � 111 4)SHIM EACH ANCHOR LOCATION WHERE 12"MAX.O.C. THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE,USING SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. 5)ANCHORS SHALL BE COATED OR CORROSION RESISTANT AS APPROPRIATE FOR SUBSTRATE MATERIAL.DISSIMILAR MATERIALS SHALL BE PROTECTED AS 6• MAX �--�—12"MAX.O.C. 2'MAX—"'� 4'MAX.O.C. REQUIRED TO PREVENT REACTIONS. ALUMINUM SHALL BE PROTECTED FROM DISSIMILAR MATERIALS AS SPECIFIED IN FLANGE FRAME INTEGRAL FIN FRAME THE FLORIDA BUILDING CODE. 6)ADHESIVE SEALANT SHALL BE USED TABLE 2:ANCHORS FOR FLANGE WINDOWS -TABLE 3:ANCHORS FOR FIN WINDOWS BETWEEN SUBSTRATE AND FLANGE OR FIN. OVERALL SEALING/FLASHING Min.Edge Min. Min.Edge Min. I STRATEGY FOR WATER RESISTANCE OF Anchor Substrate Distance Embedment Anchor Substrate DlsUnce Embedment INSTALLATION SHALL BE DONE BY OTHERS. P.T.Southern Pine(SG-.55) 1/2' 1.3/8' 2-1/2'x.113'Box Nail P.T.Southern Pine(SG-.65) 5/18" 2-7/16' 010 Sheet Metal Screw, Aluminum,6063-T5 min. 318' 1/8' 2-112"x.131•Common Nall P.T.Southem Pine(SG=.55) 3/8" 2-7/16" } 7)MATERIALS USED FOR ANCHOR G5 Steel or 410 ! EVALUATIONS WERE SOUTHERN PINE,2.7 Stainless Steel Steel Stud,Gr.33 mIn. 3/8• 0.0346"(20 ga) 2-1/2"x.145'Roofing Nall P.T.Southern Pine(SG=.65) 3/8" 2-7/16' ; KSI CONCRETE AND CONCRETE MASONRY A36 Steel 318' 1/e' P.T.Southern Pine(SG-.65) 1/2" 1-3/81 UNITS COMPLYING WITH ASTM C-90. P.T.Southern Pine(SG=.55) 1/2" 1.318' Aluminum,606375 min. 3/8" 1/8" GLAZING COMPLIES WITH ASTM E1300. 3116"Steel Uhracon Concrete(min.27 ksl) 1' 1" 010 Steel SMS Steel Stud,Gr.33 min. 3/6" 10.0346"(20 ga) 8)THE M STRESS INCREASE WAS NOT Ungrouted CMU,(ASTM G90) 1" 1-1/4' A36 Steel 3/8" 1 1/8" USED IN THIS ANCHOR EVALUATION.THE NOTE:FOR ALL METAL SUBSTRATES,SCREW EMBEDMENT SHALL BE MN.3THREADS BEYOND INSIDE FACE OF NOTE FOR ALL METALSUBSTRATES.SCREW EMBEDMENT SHALL BE MIN.3 THREADS BEYOND INSIDE FACE OF MATERIAL 1.6 LOAD DURATION FACTOR WAS USED MATERIAL FOR THE EVALUATION OF WOOD SCREWS. 9)IF THE EXACT PRODUCT SIZE IS NOT SHAPES MAY BE USED BY INSCRIBING THE SHAPE IN A BLOCK AND OBTAINING LISTED IN THE TABLES,ALWAYS ROUND DESIGN PRESSURES FOR THAT BLOCK SIZE FROM THE TABLE ON THIS SHEET. UP TO THE NEXT LARGER VALUE. TABLE 1:AS TESTED ...:1,1 ,j, ., rr �' wrn ar. G� rF,mne neo nveoYa Window Buck Size Deslgn Presume Cerdticadon _�, ,:? J.ROSOWSKI 07110/11 VINYL Moam miccremevmvmma ^;'•••�;•�•.,'< AMDPROPF MARKAOFORFIONG"n® Wltlth Height (+)pof (•)p� Numbers _ '•.;g '� MxLveawreEMrs®maeeooMa�FM 96" 60" 80 80 19D-227,474 _ tv'D.�•%%i 0 �csx7wamdEs j 75' 60" 70 70 190-230,475 0 Got+ 75' RIP 80 80 190.228 - � 6 1 • IO ��� Ti 1070 TECHNOLOGY DRIVE 48' 67 75 75 190.232,701 �TH�TE OF •.,�i NOKOMIS.R.34275 •'• a..•' FL CERT.OFAM.:29296 PICTURE WINDOW i A.Lynn Miller,P.E. s.wlrod�I: a'I.' an.e OYnYpMO ; •r��tr;..,,t" P.E.0E8705 PW-520 NTS 1 of 3 3071011JR 1 INSTALLATION WITH FLANGE FRAME EDGE DISTANCE —�- 71 BST T ` EDGE DISTANCE '/SUBSTRATE e SUBSTRATE 1- EMBEDMENT 1 / EXTERIOR 1X WOOD r 3-1/4" SHIM SHIM I Tr n n oD0 IM EXTERIOR EXTERIOR FLANGE FRAME, JAMB INSTALLATION FLANGE FRAME, FLANGE FRAME, (DIRECTLY TO SUBSTRATE) HEAD INSTALLATION HEAD INSTALLATION (USING 1X BUCKSTRIP) (DIRECTLY TO SUBSTRATE) s SUBSTRATE EXTERIOR j 0 � I a EXTERIOR �� EXTERIOR {y I SHIM 1X I u WOOD M lrrr:r SHISHI M FLANGE FRAME, 1X WOOD JA / MB INSTALLATION :,����• ' ;;; �Fa a •," (USING 1X BUCKSTRIP) '•%I �: /SUBS RATE FLANGE FRAME, SILL INSTALLATION i�'•. � N SUBSTRATE (DIRECTLY TO SUBSTRATE) `%.'•. PLCI71°'' :',-'•' FLANGE FRAME, "`1')`•! C SILL INSTALLATION (USING 1X BUCKSTRIP) J.ROSOWSKI D7110/11 VINYL nsn Kocsm oQuuO�vrAo® xa�s>R9ranlarl�varwrrarror WWW"AWCOMEM evlMt ROTO�' wa: RMOna' A PROPMTARY.NOPCRiM 7M OPpAB &YMMCRRFALMMN AWR3LWRQRIIEEASRESSB)I6%r1H/ � nsanwa�rxrsrefs INSTALLATION NOTES: 1)SEE SHEET 1 FOR SPACING REQUIREMENTS. 1070 TECHNOLOGY DRIVE j 2)SEE TABLE(S)ON SHEET 1 FOR ANCHORAGE AND SUBSTRATE REQUIREMENTS. NOKOMIS.FL 34275 TAW 3)MAX.SHIM THICKNESS TO BE I/4". FLCERT.OFAUTH.:29296 PICTURE WINDOW ' 4)GLASS SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER TO MEET DESIGN REQUIREMENTS. A.Lynn Miller,P.E 5"fiNedi1' '�`' D—tvm. Rw: 5)FLANGE MAY BE REMOVED FOR EQUAL-LEG FRAME APPLICATIONS.USE FLANGE INSTRUCTIONS. P.E.#58705 PW-520 NTS 2 of 3 3071011JR i INSTALLATION WITH FIN FRAME 7/16"LAMI GLASS NOMINAL 3/16*ANNEALED OR EMBEDMENT .090*DUPONT HEATSTRENGTHENED EDGE SOBSTFiATEJ SGPINTERLAYER GLASS DISTANCE :AIRSPACE 3/16"ANNEALED OR HEAT STRENGTHENED 3/16"ANNEALED GLASS GLASS EDGE SHIM DISTANCE ID 1/2" EXTERIOR NOR EXTERIOR DOW 1199 SILICONE EXTERIOR FIN FRAME, 40M. HEAD INSTALLATION GLAZING OPTIONS T SHIM 5/16"LAMI M GLASS NOMINAL FIN FRAME, 118"ANNEALED 11 FRAME, JAMB INSTALLATION SUBSTRATE .090"DUPONT GLASS PVBINTERLAYER 1/8"ANNEALED AIRSPACE E)(TERICIR GLASS LASS GLASS r—Ic0) SHIM 112" NOM. EXTERIOR SUBSTRATE A--] DOW 1199 I SILICONE FIN FRAME, SILL INSTALLATION PE WOMnX DEMMWA MWAAW J.ROSOWSKI 0 mcaLow crmr INSTALLATION NOTES: 10/11 VINYL R�VW V, ANtrema N< tw>x xsram'a D XA0 roclenwrelm PDATICNW� wRuRX=vN "m 'w 1)SEE SHEET I FOR SPACING REQUIREMENTS. 35 Xm 2)SEE TABLE(S)ON SHEET I FOR ANCHORAGE AND SUBSTRATE REQUIREMENTS. 3)MAX.SHIM THICKNESS TO BE 1/4-. 4)GLASS SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER TO MEET DESIGN &�'�rr- 1 1070 TECHNOLOGY DRIVE REQUIREMENTS, NOKOMIS.FL 34275 FL PICTUREW INSTRUCTIONS ON SHEET 2. 5)FIN AND FLANGE MAY BE REMOVED FOR EQUAL-LEG FRAME APPLICATIONS,USE FLANGE WINDOW A.Lynn Miller,P.E. P.F#58705 PW-520 NTS 3.13 3071011JR 5/26/2016 Florida Building Code Online Date Pending FBC Approval Date Approved 10/09/2015 Summa ry of Products FL# Model,Number or Name Description 243.1 CA-640 Fixed (Non-Impact) Aluminum Fixed Window used with Casement/Awning Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL243 R17 C CAC 15-0519.16 F.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 04/11/2018 Design Pressure: N/A Installation Instructions Other: Please see the Miami-Dade County Notice of FL243 R17 II 15-0519.16 F.Ddf Acceptance (NOA)for product performance information, Verified By: Miami-Dade BCCO-CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 243.2 CA-740 Fixed (Large Missile Impact) Aluminum Fixed Window used with Casement/Awning Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL243 R17 C CAC 15-0519.15.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 04/11/2018 Design Pressure: N/A Installation Instructions Other: Please see the Miami-Dade County Notice of FL243 R17 H 15-0519.15.odf Acceptance (NOA)for product performance information, Verified By: Miami-Dade BCCO-CER anchorage details, and anchor type,size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 243.3 PW-220 (Non-Impact) Aluminum Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL243 R17 C CAC 15-0609.08.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 08/16/2016 Design Pressure: N/A Installation Instructions Other: Please see the Miami-Dade County Notice of FL243 R17 II 15-0609.08.odf Acceptance (NOA)for product performance information, Verified By: Miami-Dade BCCO-CER anchorage details, and anchor type,size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 243-42 1 PW-520 (Large Missile Impact) WinGuard Vinyl Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL243 R17 C CAC 15-0612.13.odf A r �.: VHZ:Yes Quality Assurance Contract Expiration Date m act Resist01/08/2019 Des g r Installation Instructions Other: Please see the Miami-Dade County Notice of FL243 R17 11 15-0612.13.odf Acceptance(NOA)for product performance information, Verified By: Miami-Dade BCCO-CER anchorage details, and anchor type,size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 243.5 PW-620 (Non-Impact) Aluminum Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL243 R17 C CAC 15-0528.27.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 02/19/2019 Design Pressure: N/A Installation Instructions Other: Please see the Miami-Dade County Notice of FL243 R17 II 15-0528.27.odf Acceptance (NOA)for product performance information, Verified By: Miami-Dade BCCO-CER anchorage details, and anchor type,size,and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 243.6 PW-720 (Large Missile Impact) Aluminum Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL243 R17 C CAC 15-0528.26.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 02/19/2019 Design Pressure: N/A Installation Instructions Other: Please see the Miami-Dade County Notice of FL243 R17 IT 15-0528.26.pdf Acceptance (NOA)for product performance information, Verified By: Miami-Dade BCCO-CER anchorage details, and anchor type,size, and spacing Created by Independent Third Party: information. Evaluation Reports https://www.floridabuilding.org/pr/pr app d.aspx?param=wGEVXQwtDqu3mwFvZ35VD3jztncl%2PhNgbQXPogz3Lk%3d 214