Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 Bustness • ff ' a Regulation rZ BCIS Home I Log In I User Registration Hot Topics I Submit Surcharge I Stats&Facts I Publications I FBC Staff BCIS Site Map I Links I Search Flori a "- = :IProduct Approval USER:Public User Cror�r ME^tp;;ixl Product Approval Menu>Product or Aoollration Search>Aooiiption Ust>Application Detail FL# FL10674-1112 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived ❑ Product Manufacturer Owens Coming Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscoming.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M.Nleminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W.Knezevich,PE ® Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R12 COI 2016 01 COI Nieminen.odf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5VD/o2boQT%2b6w7ahReglCQ8ucR6ixE... 8/8/2016 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 04/18/2016 Date Validated 04/19/2016 Date Pending FBC Approval 04/20/2016 Date Approved 06/08/2016 SummarV of Products FL# Model,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FL10674 R12 II 2016 04 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R12.Ddf Impact Resistant:N/A Verified By:Robert 1.M.Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to ER,Section 5. Evaluation Reports FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT SHINGLES FL10674-R12.odf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,small addresses are public records.If you do not want your e-mall address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the llcensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a llcensee under Chapter 455,F.S.,please dick hem. Product Approval Accepts: cCtreck M Credit Card Sate I https://www.floridabuilding.org/pr/pr app_dtLaspx?param=wGEVXQwtDgtBNbEY5V°/D2boQT%2b6w7ahReglCQ8ucR6ixE... 8/8/2016 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 353 CHRISTIAN STREET,UNIT#13 TtRRINITYIERD OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-117 One Owens Corning Parkway FL10674-R12 Toledo,O1H 43659 Date of Issuance:02/06/2012 Revision 7: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for Lse of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections{noted herein. DESCRIPTIION: Owens Corning Asphalt Roof Shingles LABELING Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This EvalJuation Report consists of pages 1 through 8. Prepared by: +,'�y�'• The facsimile seal appearing was authorized by Robert Nieminen, Robert J.M.Nieminen,P.E. 's'';; _ � i;t 1i�v�F�t- ssa••- - P.E.an 04/18/2016.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 'f�"'"`�t�tdocument Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitlERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distri uting products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. TRIIIIIIY�ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Stab-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section PropertV Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Entity Examination Reference Date U�LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 U,L LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UIL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 41.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 1.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 41.1.3 Devonshire'are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, Tru Definition' Duration', Duration' Premium Cool, Tru Definition® Duration' Designer Color Collection, TruDefinition'Oakridge, Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. .2 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge'"Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. _I.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. UIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certfcaoa of Authorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 2 of 8 5.4 Wind Classification: TRINITY�ERD 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph (Volt=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles,Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph(Volt=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 55 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building 1 Code and F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 61.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shinales: 61.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire®shingles require minimum five(5)nails per shingle. ➢ WeatherGuard*HP shingles require minimum six(6)nails per shingle. ➢ DevonshireTM'shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Feltundedayment Deck Feltundedayment Deck SOadhered Weatharl.ockg Self-adhered undedaymem WeatherLocka underiayment Oripedge �Dri Drip edge Drip, 9 Nails located Naas located Yom'hom cave Z"-3"from eave install first Self-sealing adhesive ung adhesiva Starter Strip positioned along eave v 6"Well rre Dred rStr'p Plus paadwned along eave shingle with \ 6"removed Starter Strip shingle overhangs eaves and rakes/P-yh" Starter Strip Plus avuhangs eaves and rakes IM-3/4' Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Ce�cate ojAuthorization 09503 FL10674-R12 Revision 7:04/18/2016 Page 3 of 8 6.I .6 Minimum Nailing—Classicm&Supreme: TRINITY I ERD Normal Mansard or Area para Normal Mansard or Area para Wind Areas High Wind desvanes y Wind Areas High Wind desvenes y Area para vientos normaies Areas viontoa fuerres Area para vientos normales Areas vientos fuerres rz• r �` IA► �• r' z' lel z. 1. �r �r �z� rzt 5°Exposure 5 518"Exposure Erposieidn Erposieidn 6.2.7 Minimum Nailing—Berkshire®: Seabin strip. Sealard strip La tka de seAadar /La dra de seflador MIN TI_ f3 Vi" 9 Vr 9 Vf 8Vi t "8 Yt" 8 rh" e+h" Lj " t" t•1 t -L r r r Standard Fastening Pattern 6-Nail Fastening Pattern Sealantstrip La Ara de seAadar B Yf 9 Yf a Yf 8 Yr t" 1 1 r. 1 2" Asphalt roormgoement Comento de tethode astado Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-117 Certificate ofAutherizotion#9503 FL10674-R12 Revision 7:04/18/2016 Page 4 of 8 i 1 �TRINrryj ERD 6 2.8 Minimum Nailing—Devonshirelm: n Ott 8" 47 clam Nails — •••••• t• r a r 5.5/8"exposure Sealantloation Fxposiddn de 5.518 pulp Ubieaeib def sellador s§• G,, Ten 1"Spots of Ashaft Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing—Duration®,TruDefinition® Duration, Duration® Premium Cool &Tru Definition® Duration® Designer Color Collection: 4-Nail Fastening Pattern 6-Nail Fastening Pattern sumNatntasten ft area wiattt fawning area Mm Nag,>S1bm Nail,IYPIm r fr 1r 1^ 1^ 1r I 1r t^ FI F� , vs^eae^ r ve•ssa^ Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 sunNell9 cetnttng a'ea wlatn N11,lyplul 1^ 1r I 12^ 1" &11C 5yp^ �r Four 1•Spot!of Aspnett RaafNg Cement Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certificate ofAuthorization#9503 FI10674-R12 Revision 7:04/18/2016 Page 5 of 8 TRINITV ERD 6.2.1 Minimum Nailing—TruDefinition'Oakridge®,Oakridge°: 4 Nail Pattern 6 Nail Pattem Esquema con 4 clavos Esquema con 5 clavos r r I'-- �1 1. P re 12• 12' 5518 Exposure Nabs 6 5/8"Exposure Nabs Ezpodefda de 55/8pufg Clavas Expcskidn de 55/0pulg 5 5/8"Exposure Clavas 5 518"Exposu2 Exposicidir de 55/8 ptdg Exposidda de 55/8 pufg Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 S—N.Narmtemngm width Noll,To" r +r +r r rF+m"ssm• . 0 Four r-spots cIAspW RooMg Cement Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard®HP: w ' V111E AMWAY .i:%• �'�:l� IiMerw'71tt�tt�Nt7�adierI lis CiMwa6i�� Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-117 i CertirTicate of Authorization#9503 FL10674-R12 Revision 7:04118/2016 Page 6 of 8 TRINITY�ER® 6.3 Hip&Ridge Shingles: 63.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard' HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using four (4) nails per shingle. Installation of DuraRidgeTm Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 4 Flg.2 Plevalmtppvuna Direainn P TaPVlew SIUeView Naas------------------ p Nis Nails 4 Top LanGtated r t p t I 4' Piae I I T- I I p I I I I I W Tir 5i �I �Expostae V I I I I I I I 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.A 4 4 Fig.C Hip&Ridge Shingle Fastening Puevaflpl Wind ToPVWI �-Direction p p Nails Halls plans A p i i T I z' 2" I I I I �• �• A i i I T.� V. .i. i ♦ V F.Ilgt:uR 91 Eposure `I 17' I Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 7 of 8 TRINITY,ER® 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard 11°� Wind DirectionFastening Scalerlt Strip Pattern �r G°Exposure Y 'I 12° 1 Sealant Fasten 7'h° 7'h° I 6b Exposure Cover Exposed }I {I IL Fasteners with Roof Cement i 6.3.6 Minimum Nailing—DuraRidge' Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. PruailingVEM Dirocdcn Top Mew Diraeiondomimmad vwt `V en e r Diratd6ndal viantapradornimnto coo 2 it: c•� flail: j a Ovrcos Coning S=NaTi I I I ? B I I Id ' 1 i a ald� u I� — I A I�12"————-- 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA regluirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-117 Certcote ojAothorization 119503 FL10674-R12 Revision 7:04/18/2016 Page 8 of 8