Loading...
HomeMy WebLinkAboutPRODUCT APPROVALTABLE 16013.1 WIND SPEED CONVERSION6"l r - r 100 110 120 130 140 150160 170 180 190 200 Vu 78 85 93 101 108 116 121 132 139 147 1 155 F.SL Imike hear=()Mud. b.a V ur=n terp dmi ie per®ard. e. VW=va®vel deei�wintl.e.d epp0ceb1em5vModr aPaifiedin H2ap8wsINmOgb5ofSa6ov ]609.1.1. e. V,v=vl8rouedenigv wind .peed. detumined from Hgmu 1609A, 1609B, m 16090. TABLE 1509.7(1) NOMINAL (ASO) GARAGE DOOR AND ROLLING DOOR WIND LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (PSF)'•0.&4e ULTIMATE DESIGN WIND SPEED (V,d DETERMINED IN ACCORDANCE WITH SECTION 1609.3 (MPH - 3 SECOND GUM wIYU1 HM91d (a) IWMFH 110MPH 120 MPH ISOMPH 160MPH 1S)MPH IWMPH Ira MPH 130MPH 19OMPH 20014141IS) 0oo4"WO-10tleg. 8 8 9.7-9.8 103-11.9 125-342 1 14A-164 1 17.1-193 1 194-221 1 223-213 1 25.1-225 28.2-31.9 31A-355 34.8-194 10 10 8A-94 ,02 -IIA 12.1-13.6 14.2-16.0 1 163-18.5 189-213 213-U2 1 U3 -W3 W3-304 30.4 -MA 33.7-372 14 14 8.0-8.9 9.7-10.8 113-128 133-15.0 15.]-1]A 1B.0-20.0 103-222 19.1 -237 25.9-28.8 28.9-32.1 320-35.6 floM Angle >10031paa3 ' 9 7 9.6-10.9 IIA -129 13.7-1S3 16.1-132 183-519 213 -XI U.3 -W3 .6-312 S&S -3,16 30.2-384 3B2-43.0 16 7 92-10.3 10.9-122 13.1-144 155-17.2 17.7-19.7 20.4-127 13-26.0 1 26A -29A 293-316 317-365 36.6-404 79WH &5MPH 93NIPH 101MPH IOBMPH 1 116NPH 1 IUMRi 1 132" 139WH 1471,iPH IMMPH Pw SL 1 foot=309.8 vat, l 1. Fm eBadve...•aw wivtl pada hernem d,.aol 2. Table vMud .hall be djuetedtwhelght eede2p0 3. Plva evd mivoe siva rtBVUY PmMuru actingbw, d. Ncgetive prcuu seuome doahes2fruofwldt 5. Tabk vdvea im:lvd. ills Q61oed reducuw h.w, p&f=47.&SN&. TABLE 1808.7(2) ADJUSTMENT FACTOR FOR BUILDING HEIGHT AND EXPOSURE, (X) MEANSOOFHEIGHT(kep B EXPOSURE D 15 LOD - 121 1.47 20 1.00 129 -:55 25 1.00 135 f 1.61 30 LOD 1.40 '166 35 .1.05 1.45 .' 1.70 40 1.09 1.49 '- 51.76 45 1.12 1.53. 1.78 50 1.16 1.56 1.81 55 1.19 159 1.84 60 I -M 1 1.62 1.87 awl. e. daI ad euodaud with the lowereffative &lea iem1o7&W.16093(2) 'aq.L-io 8612.4.1 Garage door labeling. Garage doors &bag be labeled with a permeaem label provided by the garage door manufactmcr. The label shall identify the garage door manufacturer, the garage door model/series number, the positive and negative design pressure rating, indicate impact rated if applicable, the installation instruction, drawmg reference number, the Florida Product Approval or Miami -Dade Product Approve] number if applicable, and the applicable last standards. The required garage door components for an approved garage door assembly may be indicated using a checklist form on the label. If a checklist former is used on the label, the door installer or the garage door manufacturer shag mark We selected components on the checklist that are required to assemble an approved garage door system The installation instructions shall be provided and available on thejob am. FLORIDA BUILDING CODE -BUILDING, SU1 EDNION (2014)