HomeMy WebLinkAboutProduct ApprovalFlorida Building Code Online
Page 1 of 5
Referenced Standard and Year (of Standard) Standard Year
AN51/DASMA 108
2005
ANSI/DASMA 115
2005
ASTM E1886
14
Fpbda DepmInkrK. d
ens xoroo Spm I est, Rnarahon Hot Toots I stoxt
sorNxrye I sun Sam I wbixot— I rSc sun SCIS Sao MIP. Live , see,oh
Business�,
TAS 201
1994
TAS 202
Proaoot Approval
TAS 203
Professibhal
VSE R.n Ho Vsw
Regulation
P�st A00,01al Menu> PWUR of ArIlHoirg, Soto IA,W-t-umI Application ottan
FL N
FL16102-RB
Application Type
Revision
Code Vemlon
2014
Application Status
Approved
Comments
Archived
❑
Product Manufacturer
Clopsy BuOding Products Company
Address/Phone/Email
8585 Duke Blvd.
Mason, OR 45040
(513) 220-6062
mwesterfield@dopay.mm
Authorized Signature
Scott Hamilton
shamllton@clopay.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
AddresWPhone/Email
Category
Exterior Doors
Subcategory
Sectorial Exterior Door Assemblies
Compliance Method
Evaluation Report from a Rondo Registered Architect or a Licensed
Florida Professional Engineer
W Evaluation Report- Fanlike, Received
Flonda Engineer or Architect Name who developed
Scott Hamilton
the Evaluation Report
Florida license
PE -63286
Quality Assurance Entity
Intertek Testing Services NA Inc. - ETE/Warnock Hersey
Quality Assurance Contract Expiration Date
12/31/2028
Validated By
Gary Pfuehler
2 Validation Checklist - Hardcopy Received
Certificate of Independence
FL1610I R9 COI Certification of Independence of Validation En[ty-
G,,ry pleehler ndf
FL161 2 R8 COT Statementn Independence ofEvelbabonEatily-
SlcttHc,,,,Itan 120424.cdf
Referenced Standard and Year (of Standard) Standard Year
AN51/DASMA 108
2005
ANSI/DASMA 115
2005
ASTM E1886
2005
ASTM E1996
2009
ASTM E330
2002
TAS 201
1994
TAS 202
1994
TAS 203
1994
http://www.floridahuilding.org/pr/pr_app_Atl.aspx?param=wGEVXQwtDgvyf4ngAXhl09... 1/20/2016
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option O
Date Submitted 08/31/2015
Date Validated 08/31/2015
Date Pending Fee Approval 09/07/2015
Data Approved 10/16/2015
Summary of Products
Go to Page O 42
Page 2 of 5
0 0 Page2/300
http://www.floridahuilding.org/pr/pr_app_dtl.aspx?param=wGE V XQwtDgvyf4ngAXh 109... 1/20/2016
FL#
Model, Number or Name
Description
16107.21
21 WB -16 DSIE-11`471: GD25P,
Double -skin Insulated EPS (exterior skin 27 ga. min.;
GR25P, GD2LP, GR2lP, AR25P,
Interior skin 27 ga. min.) Double -Car (9'2' to 16'2' wide)
Afta P, ED2SP, ED2LP, 4302,
WINDCODE(D W8 Garage Door with Opidonal Impact-
HDGC, 6202, MFC68, 4305, HDGR,
Resistant Lites
6205, SPES, MFR68
Limits of Use
installation instructions
Approved for use In HVHZ: Yes
FL16107 R811 304786-Rev04-smed.od
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes
Created by Independent Third Party: No
Design Pressure: +46 PSF/-52 PSF
Evaluation Reports
Other: Max. Wind Speed (V_ulu: 170 MPH. Solid doors or
FL16107 RR AE CBPC 130214-A,Pdf
doors with optional Impact -resistant glazing are Impact-
Created by Independent Third Party: No
resistant (large missile Impact).
16107.22
22 W6-09 DSIE-1F171: 4400,
Double -skin Insulated EPS (exterior skin 27 ga. min.;
4401, 4301, 4300, 4301, 4310,
Interior skin 22 ga, min.) Single -Car (up to 9'0' wide)
HDC, HDGL, HDGF, 66, 66G, 67,
�6200,6201,6203
WINDCODES W6 Garage Door with Optional Impact -
67G, 68, SP200, SF200, SE200,
Resistant Utes
Limits o/ Use
Installation Instructions
Approved for use In HVHZ: Yes
FL16107 R811 I01526-A-Rev19-sianed.ntlf
Approved for use outside HVHZ: Yes
Vedfed By: Scott Hamilton FL PE 63286
Impact Resistant: Yes
Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF
Evaluation Reports
Other: Max. Wind Speed (V_ulD: 170 MPH. Sold doors Or
FL16107 RB AE CBPC 130214-Andf
doors with optional Impact -resistant glazing are Impact-
Created by Independent Third Party: No
resistant (large missile Impact).
16107.23
23 W6-09 DSIE-1F171: 4400,
Double -skin Insulated EPS (exterior skin 27 ga. min.;
4401, 4300, 4301, 4310, HOG,
Interior skin 27 ga. min.) Single -Car (up to 9'0' wide)
HDGL, HDGF, 66, BIG, 67, 67G,
WINDCODER W6 Garage Door
68, SP200, SF200, SE200, 6200,
6201, 6203
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
EL151n7 R8 II 101526-B Rev19-siunetl otlf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No
Created by Independent ThlM Party: No
Design Pressure: +38 PSF/-44 PSF
Evaluation Reports
Other: Doors with standard glazing meet the wind load
FL16107 RS AE CBPC 130214-A ndf
requirements of the building code but DO NOT meet the
Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
16107.24
24 W6-09 PAN -21`353: 04A, 94, 73,
Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide)
75, 1500, 190, 4RST, 4RSF, 41`,
WINDCODEO W6 Garage Door with Optional Impact-
6RST, 6HSF, 48, 42, 55, 48B, 425,
Resistant Dies
555, GOSS, GD5SV, GR5S, GRSSV,
AR5S, AR5Sv, EOSS, EDSSV
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16107 RB 11 101348-A-Rev17-sinned odf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes
Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF
Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or
EL16107 RB AE CBPC 130214-A cdf
tloors with optional Impact -resistant glazing are Impact-
Created by Independent Third Party: No
resistant (large missile impact).
http://www.floridahuilding.org/pr/pr_app_dtl.aspx?param=wGE V XQwtDgvyf4ngAXh 109... 1/20/2016
Florida Building Code Online
Page 3 of 5
16107.25
25 W6-09 PAN -2F353: 84A, 94, 73,
Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide)
75, 1500, 190, 4RSr, 4RSF, 4F,
WINDCODE® W6 Garage Door
6RST, 6RSF, 48, 42, 55, 48B, 428,
55S, GOSS, GD5SV, GR55, GR5SV,
AR55, AR55V, EDSS, EDSSV
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16107 R6 II 101348-6-Rev17-s nnetl odf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No
Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF
Evaluation Reporter
Other: Doors with standard glazing meet the wind load
FL16107 R8 AE CBPC 130214-6odf
requirements of the building castle but DO NOT meet the
Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
16107.26
26 W6-09 PAN -2F356: 76, 76%
Steel Pan (min. 25 ga.) Single -Gr (up to 911" wide)
j 2RST
WINDCODE®W6 Garage Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16107 R8 II 101346-A-Rev17-sonedudf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes
Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF
Evaluation Reports
Other: Max. Wind Speed (V_u1n: 170 MPH. Solid doors or
FL16107 RB AE CBPC 130214-A odf
doom with optional impact -resistant glazing are Impact-
Created by Independent Third Party: No
resistant (large missile Impact).
16107.27
27 W6-09 PAN -21`156: 76, 76V,
Steel Pan (min. 25 ga.) Single -Car (up to 9'0' wide)
2RST
WINDCODE® W6 Garage Door
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL16107 RB II 101348-8-Rev17-sionetl iid
Approved for use outside HVHZ: Yes
Variied By: Scott Hamilton FL PE 63286
Impact Resistant: No
Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF
Evaluation Reports
Other: Doors with standard glazing meet the wind load
FL16107 RS AE CBPC 130214 -Ani f
requlrements of the building code but DO NOT meet the
Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
16107.28
28 W6-09 DSIE-IA171: 2050,
Double -skin Insulated EPS(extenor skin 27 ga. min.; interior
2051, 2053, 4050, 4051, 4053, 62,
skin 29 ga. min.) Single -Car (up to 9'0" wide) WINDCODE&
64, 65, 62G, 62LG, 64G, SDP38,
WG Garage Door
SF B, SRP38, 134, 135, 136,
6130, 6131, 6133
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16107 RB II 104614-A-Rev00-5nned odf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes
Created by Independent Third Party: No
Design Pressure: +36 PSF/-44 PSF
Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors are
FL16107 RB AE CBPC 130423-A.Ddf
Impact -resistant (large missile Impact).
Created! by Independent Third Party: No
16107.29
29 W6-09 DSIE-1A171: 2050,
Double -skin Insulated EPS(eMerior skin 27 ga. ming Interior
2051, 2053, 4050, 4051, 4053, 62,
skin 29 ga. min.) Single -Car (up to 9'0" wide) W INDCODEd4
64, 65, 62G, 62LG, 64G, SDP38,
W6 Garage Door
SHOO, SRP38, 134, 135, 136,
6130, 6131, 6133
Limits of Use
Installation Instructions
Approved for use In HVHZ: NO
FI 1610) RB II 104814-9-Rev00-sia redmif
Approved for use outside HVHZ: Yes
Venfied By: Scott Hamilton FL PE 63286
Impact Resistant: No
Created by Independent Third Party: No
Design Pressure: +36 PSF/-44 PSF
Evaluation Reports
Other: Doors with standard glazing meet the wind load
FL36107 IS AE CBPC 130423-A.odf
requirements of Ne building code but DO NOT meet the
Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
16107.30
30 W6-09 DSIE-1F471: GD2SP,
Double -skin Insulated EPS (exterior skin 27 ga. min.;
GR25P, GD2LP, GR2LP, AR25P,
Interior skin 27 ga. min.) Single -Car (up to 9'0' wide)
AR20, ED2SP, ED2LP, 4302,
WINDCODEO W6 Garage Door with Optional Impact-
HDGC, 6202, MFC68, 4305, HDGR,
Resistant Lites
6205, SFR68, MFR68
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16107 R8 It 103954-A-Rev05-sgnetludf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact ResistanH Yes
Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF
Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or
FL16107 R8 AE CBPC 130423-A odf
doom with optional impact -resistant glazing are Impact-
Created by Independent Third Party: No
resistant (large missile Impact).
16107.31
31 W6-09 DSIE-1F471: GD2SP,
GR25P, GD2LP, GR21P, AR2SP,
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?pu m=wGEVXQwtDgvyf4ngAXh109... 1/20/2016
Florida Building Code Online
Page 4 of 5
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?pa==wGEVXQwtDgvyf4ngAXh 109... 1/20/2016
AR21-P, ED2SP, E02LP, 4302,
Double -skin Insulated EPS (exterior skin 22 ga. min.;
HDGC, 6202, MFC68, 4305, POOR,
interior skin 27 ga, min.) Single -Car (up to 9'0' wide)
6205, SFR68, MFR68
WINDCOOE® W6 Garage Door
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL16107 RB 11103954-B-Rev05-smmMJ.Md
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton 11 PE 63286
Impact Resistant: No
Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF
Evaluation Reports
Other: Doors with standard glazing meet the wind load
FL16107 RS AE CBPC 1301
requirements of the building code but DO NOT meet the
Created by Independent Third Party: No
impact resistant requirement for windbome debris regions.
16107.32
32 W6-09 PAN -2F443: G4S, GS4,
Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Sogle-
GD4S, GR4S, G45V, G54V, GDGSV,
Car (up M 9T' wide) WINDCODE® W6 Garage Door with
GR45V, E4S, ED4S, E4SV, ED4SV,
Optlonal Impact -Resistant Lite.
554, AR45, S54V, AR45V
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16107 RB II 103488-A-ReYaLain e0.odf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant Ye.
Created by Independent ThlM Party: No
Design Pressure: +38 PSF/-44 PSF
Evaluation Reports
Other: Max. Wind Speed (V_ult): 120 MPH. Sold doom or
FLIE107 R8 AE CBPC 130423-A.Ddf
doors with optional impact -resistant glazing are impact-
Created by Independent Third Party: No
resistant (large missile impact).
16107.33 33 W6-09 PAN -21`443: G4S, GS4,
Double -skin Insulated EPS (exterior skin 27 ga. min.;
GD45, GR4S, G4SV, GS,IV, GD4SV,
interior skin 27 ga. min.) Single -Gr (up to 9'0' wide)
GR45V, E4S, ED45, E45V, ED4SV,
WINDCODEct W6 Garage Door
SS4, AR45, SSAW, AR4SV
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL 16107 RR 11103488-8-Rev07-,mm,d.M1
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No
Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF
Evaluation Reports
Other: Doors with standard glazing meet the wind load
FL16107 R8 AE CBPC 130423-A otlf
requirements of Ne building mtle but DO NOT meet the
Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
16107.34
34 W6-09 PAN -21`446: G,IL, GL4,
Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Single-
GD41L, GR4L, G4LV, GL4V, GD4LV,
Car (up to 9'0- wide) WINDCODE® W6 Garage Door with
GR4LV, E4L, ED4L, E4LV, ED4LV,
Optional ImCact-Resetant Lites
SL4, AR4L, SL4V, AR4LV
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16107 RB II 103488-A-Re07-amnetlodf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant Yes
Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF
Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or
FL16107 RB AE CBPC- 130423-A odf
doom with optional Impact -resistant glazing are Impact-
Created by Independent Third Party: No
resistant (large ml69lle Impact).
16107.35
35 W6-09 PAN -2F446: G4L, GL4,
Gallery/ArtIRry/Expressions: Steel Pan (min. 24 ga.) Single-
GD4L, GR4L, G4LV, GL4V, GD4LV,
Car (up to 9'0" wide) WINDCODE® W6 Garage Door
GR4LV, E4L, ED4L, E4LV, ED4LV,
SL4, AR4L, SL4V, AR4LV
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16107 RS 11 103488-B-Rev07-sioned.odf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No
Created by Independent Third Pa": No
Design Pressure: +38 PSF/-44 PSF
Evaluation Reports
Other: Doors with standard glazing meet he wind load
FL16107 RB AE CBPC 130423-A-0df
requirements of the building code but DO NOT meet the
Created by Independent Third Party: No
Impact resistant requirement for windbom , debris regions.
16107.36
36 W6-16 PAN -2F443: GD45,
Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.)
GR4S, ED4S, AR45
Double -Car (92- to 162' wide) WINDCODEG, W6 Garage
Door with Optional Impact -Resistant Utes
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16107 8811104790-A-Revo5-sp,:,Lm1
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes
Created by Independent Third Party: No
Design Pressure: +38 PSF/-42 PSF
Evaluation Reports
Other: Max. Wind Speed (V_ultb 170 MPH. Solid doors or
FL16107 RS AE CBPC 130423-A odf
doors with optional impact -resistant glazing are impact-
Created by Independent Third Party: No
resistant (large missile impact).
16107.37
37 W6-16 PAN -2F443: GD45,
Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.)
GR4S, ED45, Ax
Double -Car (9'2"to 16'2"wide) WINDCODE®W6 Garage
Door
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?pa==wGEVXQwtDgvyf4ngAXh 109... 1/20/2016
Florida Building Code Online
Page 5 of 5
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16107 RS I ID4290-B-Rea05-s cccdydf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No
Created by Independent Third Party: No
Design Pressure: +38 PSF/-42 PSF
Evaluation Reports
Other: Doors with standard glazing meet the wind load
FL16107 RS AE CBPC 130423-A udf
requirements of the building code but DO NOT meet the
Created by Independent Third Party: No
impact resistant requirement for wintlbome debris regions.
16107.38
38 W6-16 PAN -2F446: GD4L,
Gallery/Ardstry/Expressions: Steel Pan (min. 24 ga.)
GR4L, ED4L, AR4L
Double -Car (9'2" to 16'V wide) WINDCOOE W6 Garage
Door with Optional Impact -Resistant toes
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL16107 R811104790-A-Rey05-simetlml
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes
Created by Independent Third Parry: No
Design Pressure: +38 PSF/-42 PSF
Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Said doors or
FLI6107 RB AS CBPC 130423-A odf
doors with optional impect-redstant glazing are Impact-
Created by Independent Thlyd Parry: No
resistant (large missile impact).
16107.39
39 W6-16 PAN -2F446: GD4L,
Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.)
GR4L, ED4L, AR4L
Double -Car (9'2" to 16'2' wide) WINDCODE(D W6 Garage
Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16107 RS II 104790-B-RPv05-ohned.odf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No
Created by Independent T61M Party: No
Design Pressure: +38 PSF/-42 PSF
Evaluation Reports
Other: Doors with standard glazing meet the wind load
FL16107 R8 AE CBPC 130423-A.odf
requirements of the building code but DO NOT meet the
Created by Independent Third Party: No
Impact resistant requirement for wintlbome debris regions.
16107.40
40 W8-09 DSIE-1F471: GD2SP,
Double -skin Insulated EPS (exterior skin 27 ga, min.;
GR25P, GD2LP, GR2LP, AR25P,
Interior skin 27 ga. min.) Single -Car (up to 9'O" wide)
AR21P, ED2SP, ED21P, 4302,
WINDCODE® W8 Garage Door with Control Impact-
HDGC, 6202, MFC68, 4305, HDGR,
Resistant Utes
6205, SFR68, MFR68
Limits of Use
Installation Instructions
Approved for use in HVHZ; Yes
FL16107 RS 11 104119-Re44-sinned odf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes
Created by Independent Third Party: No
Design Pressure: +54 PSF/-60 PSF
Evaluation Reports
Other: Max. Wind Speed (V_u1n: 170 MPH. Solid doors or
FL16107 R8 AE CBPC 130423-A.odf
doors with optional impact -resistant glazing are impact-
Created by Independent Third Parry: No
resistant (large missile impact).
Go to Page O® 0 Page 2/ 3 d m
0
fPp1a[tUs ::
rpOidech nemrc sVxc1dyVdzeft32329 mane ssoae7;ers
iMstab Mrwnea isxn NJtEOemolWe.. rnrvim .. ::Mrer emnt..Rr
Pori APPI-1 AMestu
w®0®
credits(I�FE
http://www. floridabuilding.org/pr/pr_app_dtl.aspx?pa==wGEV XQwtDgvyf4ngAXh 109... 1/20/2016