Loading...
HomeMy WebLinkAboutProduct Approval Company: The Home Depot At Home Services Job Description: Replacing 4 doors and 1 wir Prepared By: Amber Client Name: Schweiger Project Number: 9441664 Zr� tr.0u_c_ E.7.30:a. .w•�; . DESIGN PRESSURES FOR WALL COMPONENTS&CLADDING Design Data Building Data Wind Velocity(mph) 160 Mean Roof Height 20 Risk Category 2 Building Width(ft) 56 Exposure Category D Building Length(ft) 33 Directionality Factor 0.85 . Roof Slope (x:12) 1 Internal Pressure Coefficient+/- 0.18 Design pressures listed below are: Allowable Stress OPENING OPENING LOCATION OPENING OPENING DIMENSIONS MAXIMUM POSITIVE MAXIMUM NEGATIVE MARK DESCRIPTION ZONE ELEVATION WIDTH(INCHES) HEIGHT(INCHES) PERSSURE(PSF) PRESSURE(PSF) 1 5500-PD-SL 5 0 96 80 33.5 -43.8 2 5500-PD-SL 5 0 72 80 34.2 -45.2 3 5500-SH 5 5 32 38 37.5 -52.1 4 5500-PD-SL 5 0 96 80 33.5 -43.8 5 5500-PD-SL 5 0 72 80 34.2 -45.2 Width of End Zone(a)in feet= 3.3 s h �Q 5 O 4 a Y i �Q 5 5 UWE -'STRUCTURES.INTERNATIONAL, LLC 7/26/2016 3:05 PM