NOA No.: 14-0828.04
Expiration Date: 02/28/17
Approval Date: 02/12/15
Page 1 of 6
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
CertainTeed Corporation
1400 Union Meeting Road
Blue Bell, PA 19422
SCOPE :
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION : Landmark, Landmark Pro, Landmark Premium, Landmark Impact Resistant, Landmark
Solaris, and Landmark Pro/Architectural 80
LABELING : Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT : The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety .
INSPECTION : A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA #12-1204.01 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 14-0828.04
Expiration Date: 02/28/17
Approval Date: 02/12/15
Page 2 of 6
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials Dimensional
Deck Type: Wood
SCOPE
This renews CertainTeed Landmark, Landmark Pro, Landmark Premium, Landmark Impact Resistant and
Landmark Solaris Shingles as manufactured by CertainTeed Corporation described in Section 2 of this Notice of
Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test
Specifications
Product Description
Certainteed Landmark
Manufacturing
Locations #1, 2, 3, 4, 5, 6, 7, 8, 9
13¼" x 38 ¾” TAS 110 A heavy weight, dimensional asphalt
shingle.
Certainteed Landmark Pro
Manufacturing
Locations #1, 3, 4, 5, 6, 9
13¼" x 38 ¾” TAS 110 A heavy weight, dimensional asphalt
shingle.
Certainteed Landmark Premium
Manufacturing
Locations #1, 3, 4, 5, 6, 8, 9
13¼" x 38 ¾” TAS 110 A heavy weight, dimensional asphalt
shingle.
Certainteed Landmark Impact
Resistant
Manufacturing
Locations #1, 7
13¼" x 38 ¾” TAS 110 A heavy weight, dimensional asphalt
shingle.
Certainteed Landmark Solaris
Manufacturing
Locations #1, 8
13¼" x 38 ¾” TAS 110 A heavy weight, dimensional asphalt
shingle.
Certainteed Landmark
Pro/Architect 80
Manufacturing
Locations #8
13¼" x 38 ¾” TAS 110 A heavy weight, dimensional asphalt
shingle.
Accessory Shingles
various proprietary Accessory shingles for hip, ridge and starter
strip applications.
NOA No.: 14-0828.04
Expiration Date: 02/28/17
Approval Date: 02/12/15
Page 3 of 6
MANUFACTURING LOCATION (S):
1. Peachtree City, GA.
2. Ennis, TX.
3. Oxford, NC.
4. Shakopee, MN.
5. Avery (Milan), OH
6. Norwood, MA
7. Shreveport, LA.
8. Portland, OR.
9. Wilmington, CA.
EVIDENCE SUBMITTED :
Test Agency
Test Identifier Test Name/Report Date
Underwriters Laboratories, Inc. R684 UL 790 04/02/01
PRI Asphalt Technologies, Inc. PCTC-01-02-01 TAS 100 01/12/01
CTC-006-02-01 TAS 100 11/12/02
PRI Construction Materials Technologies CTC-092-02-01 TAS 100 02/23/12
CTC-091-02-01 TAS 100 02/21/12
CTC-090-02-01 TAS 100 09/02/11
CTC-087-02-01 TAS 100 07/07/11
CTC-086-02-01 TAS 100 07/07/11
CTC-101-02-01 TAS 100 10/05/11
CTC-102-02-01 TAS 100 10/05/11
CTC-109-02-01 TAS 100 01/18/12
CTC-106-02-01 TAS 100 11/02/11
CTC-105-02-01 TAS 100 10/31/11
CTC-089-02-01 TAS 100 07/18/11
CTC-088-02-01 TAS 100 07/18/11
CTC-213-02-01 TAS 100 05/20/14
CTC-212-02-01 TAS 100 05/21/14
CTC-207-02-01 TAS 100 05/20/14
CTC-206-02-01 TAS 100 05/20/14
CTC-110-02-01 TAS 100 02/13/12
CTC-109-02-01 TAS 100 02/13/12
Underwriters Laboratories, Inc. 94NK9632 Wind uplift resistance TAS 107 11/30/00
02NK42448 Wind uplift resistance TAS 107 11/08/02
09CA28873 Letter 07/23/09
11CA59020 TAS 107/ ASTM D3161 01/25/12
11NK07864 TAS 107/ ASTM D3161 09/29/11
07CA26696 TAS 107/ ASTM D3161 09/21/07
11CA38844 TAS 107/ ASTM D3161 01/28/12
11CA38844 TAS 107/ ASTM D3161 01/27/12
11CA38844 TAS 107/ ASTM D3161 01/26/12
06CA02648 TAS 107/ ASTM D3161 02/23/06
NOA No.: 14-0828.04
Expiration Date: 02/28/17
Approval Date: 02/12/15
Page 4 of 6
06CA28237 TAS 107/ ASTM D3161 09/22/06
10NK17366 TAS 107/ ASTM D3161 01/04/11
4786334383 TAS 107/ ASTM D3161 05/28/14
4786307351 TAS 107/ ASTM D3161/ASTM D 3462 05/13/14
11NK08333 ASTM D3462 05/15/12
11NK08333 ASTM D3462 04/15/12
11NK07864 ASTM D3462 09/29/11
11NK08333/Letter ASTM D3462 / UL790 11/05/12
11NK08333/Letter ASTM D3462 / UL790 11/05/12
11NK08333/Letter ASTM D3462 / UL790 11/05/12
12NK13474 ASTM D3462 / UL790 05/27/13
4786325932 ASTM D3462 / UL790 04/04/14
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Detail 'B', attached.
LABELING
1. Shingles shall be labeled with the Miami-Dade Product Control approved seal as seen below or the wording
“Miami-Dade County Product Control Approved”.
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 14-0828.04
Expiration Date: 02/28/17
Approval Date: 02/12/15
Page 5 of 6
DETAIL A
5
32 3/4
11
11
27 3/4
6
5 5/8
6
16 3/4
Eaves
Shingle
Full Starter
6
CertainTeed Landmark, Landmark Pro,
Landmark Premium, Landmark Special, and Landmark So laris
5
6
Edge
Rake
LANDMARK , LANDMARK PRO , LANDMARK PREMIUM , LANDMARK IMPACT RESISTANT ,
LANDMARK SOLARIS , AND LANDMARK PRO /A RCHITECT 80
SHINGLE LAYOUT
NOA No.: 14-0828.04
Expiration Date: 02/28/17
Approval Date: 02/12/15
Page 6 of 6
DETAIL B
12"
38 3/4"
NAILING
AREA
WIDE 1"
{
5 5/8"
Exposure
12" 14 3/4"
Release Tape
Nailing area for "low and standard" slopes (from 3.5:12 to 21:12)
Nail between upper & lower nail lines.
13 1/4"
7 1/2"
6"
1"
LANDMARK , LANDMARK PRO , LANDMARK PREMIUM , LANDMARK IMPACT RESISTANT ,
LANDMARK SOLARIS , AND LANDMARK PRO /A RCHITECT 80
(L OW AND STANDARD SLOPE )
1"
Nailing area for "steep" slopes (greater than 21:12)
Nail between bottom 2 nail lines.
Release Tape
13 1/4"
1"
6 1/8" 5 5/8"
Exposure
12" 14 3/4" 12"
LANDMARK , LANDMARK PRO , LANDMARK PREMIUM , LANDMARK IMPACT RESISTANT ,
LANDMARK SOLARIS , AND LANDMARK PRO /A RCHITECT 80
(STEEP SLOPE )
END OF THIS ACCEPTANCE