HomeMy WebLinkAboutBuilding Permit ApplicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: Permit Number:
� 7,._..;,,,.
• Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772)462-1553 Fax:(772)462-1578 Commercial Residential J
PERMIT APPLICATION FOR: Plumbing
PROPOSED IMPROVEMENT LOCATION:
Address: 9400 S OCEAN DR APT 604 - JENSEN BEACH, FL 34957
Legal Description: OCEAN TOWERS CONDOMINIUM B - UNIT 604 AND UNDIV SHARE IN COMMON ELEMENTS (OR 3320-2791).
Property Tax ID #: 3535-702-0043-OOM
Site Plan Name:
Project Name:
Setbacks Front Back:
Right Side:
DETAILED DESCRIPTION OF WORK:
le, - hert k. -//o Ila
Wr i 3o yq //on e%e94-1 c uia-hcv h
INFORMATION:
[_MVAC L__1 Gas Tank
11 Electric ❑✓_Plumbing
Total Sq. Ft of Construction: _
Cost of Construction: $ 975.00
Left Side:
Lot No.
Block No.
under /i�c Cl n, /-
Sas Piping IL�IShutters II��IIWindows/Doors
Sprinklers L�IGenerator t -Roof Roofpitch
S . Ft. of First Floor:
Utilities: Sewer Septic Building Height:
m W fR/LESSEE: N ..
CONTRACTOR: -
Name Barbara NICHOLSEN
Name: Robert W. LUDLUM
Address: 10508 SW Stratton or
Company: Benjamin Franklin Plumbing
City: Port St Lucie State: FL
Zip Code: 34987 Fax: nia
Phone No. 772-708-3425
Address: 1631 SW South Macedo Blvd
City: Port St Lucie State: FL
Zip Code: 34984 Fax: 772-871-9494
Phone No. 772-871-8494
E -Mail: nia
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
E -Mail: Permits@benfranklinplumber.com
State or County License: CFC1426801
u varve or construction is pcwu or more, a rmcueueu nonce or commencement Is regwrea.
SUPPLE
Name:
City:
Zip: -
FEE SIMPLE TITLE HOLDER:
Name:
Address:
City:
Zip: Phone: _
LIEN LAW INFORMATION:
Not Applicable
MORTGAGE COMPANY: _ Not Applicable
Name:
Address:
City: State: _
Zip: Phone:
BONDING COMPANY:
Name:
Address:
Zip:
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie Court makes no representation that is granting a permit will authorize the Dermit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or antl covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
Inconsideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection_ If you intend to obtain financing, consult with lender or an attorney before
STATE OF FLORIDA
COUNTY OF S' "may' z e -
The for oing instru nt was acknowledged before me
this AKbday of UST— 20 Lby
(Name of person acknowledging)
(Signbture of rotary Public -State of Florida I
Personally Known V OR Produced Identification
Type of Identification Pro
blit, . Stale al F10101
Commission No. '�� lesion M IF 961861
icj�96/ble/ { Mr Comm. Expires May 5. 202C
ppprNNrenaNbwyOsm
Revised 07/15/2014
STATE OF FLORIDA /
COUNTY OF T
The forgoing instrum t was acknowledged before me
this ( �tlday of 5'E 20/60 by
(Namee of person aacckn wlleedddgringI
(Signatu of Nota Public- State of Florida )
n ✓OR Produced Identification
ation Produced
Public - slab of
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEA TURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
COMPLETE
INITIALS
•Smith® Residential Electric
Water Heaters
ENHANCED HEATING ELEMENTS CODE COMPLIANCE
• Dual 4500 watt elements for fast recovery • Meets UBC and ICC National Codes and
and reliable operation." listed with CEC.
• Incoloy, stainless steel lower element lasts • Complies with the Federal Energy
longer than a standard copper element. Conservation Standards effective
DYNACLEAN'" DIFFUSER DIPTUBE April 16, 2015, in accordance with the
Energy Policy and Conservation Act
• Helps reduce lime and sediment buildup (EPCA), as amended.
and maximizes hot water output. Made
from long-lasting PEX crass -linked
polymer,
HIGH ENERGY FACTORS
• Eco -friendly non -CFC foam insulation,
heat traps and other features combine
to yield a higher Energy Factor that
maximizes savings on operating costs.
COREGARD' ANODE ROD
• Our anode rods have a stainless steel
core that extends the Irfe of the anode
rod allowing superior tank protection far
longer than standard anode rods.
BLUE DIAMONDer GLASS COATING
• Provides superior corrosion resistance
compared to industry standard glass
lining.
ENHANCED -FLOW BRASS DRAIN VALVE
• Our residential water heaters have a solid
brass, tamper resistant, enhanced -flow,
ball type, drain valve.
• Uses a standard female hose fitting that
allows for fast and easy draining during
maintenance.
• Designed for easy operation, this valve
includes an integral screwdriver slot that
features a 1/4 turn (open/close) radius,
which not only permits full straight -
through water flow but also a quick and
positive shut off.
'Model ENL -20 M1,10 single eierrent.
APPROVED FOR MANUFACTURED
HOUSING
• All residential electric water heaters are
compliant with HUD Standards for mobile
homes/manufactured housing.
CERTIFIED TO UL 174 FOR HOUSEHOLD
ELECTRIC WATER HEATERS
CSA CERTIFIED AND ASME RATED T&P
RELIEF VALVE
DESIGN -LISTED BY UNDERWRITERS
LABORATORIES
• Certified at 300 psi test pressure and 150
psi working pressure.
• Listed according to UL 174 standards
governing storage tank type electric water
heaters.
6 -YEAR LIMITED TANK AND PARTS
WARRANTY
• For complete information, consult written
warranty or go to hotwateccom,
SA° UL
01,mtl,2016 A. 0, S.m Corpomtlon. Al rl9M1rs,esewed 4a➢el of J
wwerholwatermm 19003279953 Toll -Free OSA IA. Q Smith Corporation I SOO Tennesee MIU Parkway IAShrand Ciry, TN 37015 AOSRE50602
Ce Smith.
Residential Electric
Water Heaters
Model
Number
Gallon
Capacity
First Hour
patio
all
Energy
Factor
Recovery®
90-F Rise
Gallon Per
Hour
Element Wattage 240V
Dimensions in Inches
Apprax.
Shipping
Weight (lbs)
Standard Maximum
A B G
Tall Models
ENT -30t
30
4]
095
21
4500
6000
46112
39-112
19
95
ENi-40t
AO
51
0.95
L
4500
6000
60114
53 1w
20
118
FMB�50"
50
]0
095
21
4500
6000
60114
1 51114 1
F
131
ENr-sot
so
]I
0.95
D
4500
6000
fi0.112
s1-114
zz
134
ENT -551
55
]fi
0.94
2'h
4500
6000
56V2
48 112 1
24
1 145
Short Models
EMM"
30
48
0.95
21
4500
600D
39
30412
20
95
ENS-3ot
30
49
095
21
4500
6000
39-31<
30.112
22
94
ENS 401
40
55
0.95
dl
4500
1 6000
50
40-314
20-112
109
ENS -501
50
62
1 095
1 21
1 4500
1 6000
49-314
1 40-318 1
23
161
Lowba Ta
Connect Models
ENL -20
19.5
1 NIA
WA
21
4500
6000
30
21114
20
65
28
40
0.95
21
4500
bo0o
30
21-314
22
96
28
43
0.95
21
4500
6000
31-114
21-314
24
115
a
38
46
0.95
21
4500
6000
31 314
24
24
118
38
44
0.95
21
4500
6000
33-112
24
26
118
48
5)
0.95
21
1 41
1 6000
1 34
25 1
26112
1 122
Male 314" wale, 11,111,11, 118- 1Cel.
"Models ship with supplied coolant, blanket
lit 1O year lank and 6,ear pans pence,, Change -Ftp -P'In The lndel number (example ENT M becomes Ped 30).
_ Top go
option nor am1a01e o, this model
ME 20u asingle element funfigwalion only
Opll0nal cop'BP 1111tl0n 12 Bused tin the FNR50. EN1850, ENb55, ENS 40 and ENS 50
Opliondl l.p &P lorauon 1315 used on the Thin 50.
lop TSP is not available on The 10 year model Ends 50.
Dimensions rude spefdhcaL9 us zu bleO to (nnnge w.0mid muc, in accordance with ou, pfbry of m,unuoas podam h mpmvemen:.
T&P VALVE
ACCESS
PANEL
ACCESS
PANEL
DRAIN
VALVE
ANODE (OR OPTIONAL
TOP T&P LOCATION #i)
OPTIONALTOPT&P
LOCATION #3
} OPTIONALTOPT&P
o o LOCATION #2
C OO OO O JUNCTION
BOX
T&P VALVE
door x016 Asmmn Cnrpmallon. Nl rights ree,vea- ia,,,n1]
—hotwatermm 1900 5171953 Toll Free OSA AOSRES0602