HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 4
'-091i
�.•t+ `5 I F i p.� 7 1 C b. �.: + C ��a)�i'+'�.a 14i 6�r �i�` r.. - f r+wnll�yd
',i i-t t SCIS Home , Log in User R_y,stratlon Hot Topic. Submit Surcharge Stats&Fads Publications FOC Stall - MS Site Map Links Search
Business,,
Professional l;;jt5 USER:Pc lic Use Approval
USER:Public Use
17Prtxhrct Aotxoyal wenu>Pm,4at:c Acnitcatson S=arch>Amh:ation uv,>Appiimtion Detail
12112 T
FL# FL1956-R12
RM1VIE ,� Application Type Editorial Change
Code Version 2014
Application Status Approved
Approved by DBPR.Approvals by:DBPR shall be reviewed and
ratified by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer TAMKO Building Products,Inc.
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerri Eden.
kerri_eden@tamko.com
Technical.Representative Kern Eden
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri—eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Certification Mark or Usting
Certification Agency UL LLC
Validated By Robert J.M.Nieminen,PE
Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
Date Submitted 09/17/2015
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6... 3/23/2016
Florida Building Code Online Page 2 of 4
Date Validated 10/06/2015
Date Pending FBC Approval
Date Approved 10/09/2015
Summa of Products
FL# Model,Number Description
or Name
1956.1 Elite Glass-Seal A three tab asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in F41956 R12 C CAC FL1956 R13 G CAC Tamko Stay Conf FL 195§ 2035 idf
HVHZ:No F0956 R12 C GIC UL certification 10-11-12.ndf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A FL1956 R12 II Giass Seal Elft Mass Seal apg inst.ndr
Other:Asphalt shingles Verified By:Robert Nierninen 59166
shall be used only on roof Created by Independent Third Party:No
slopes of 2:12 or greater. Evaluation Reports
Nails must be used as the Created by Independent Third Party:
method of attachment.
1956.2 1 Glass-Seal A three tab asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R1 C CAC Tamko Sery Conf FL 1956 2015.pdf
HVHZ:No F€1956 Rt 2 C CAC UL Certification I0.11.12 pdf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact,Resistant:N/A Installation Instructions
Design Pressure:N/A _&7 Q56R.11JI Gass Seal Elite Gf1 ss Seal gap inst,pdf
Other:Asphalt shingles Verified By:Robert Nieminen PE 59166'
shall be used only on roof Created by Independent Third Party:No
slopes of 2:12 or greater. Evaluation Reports
Nails must be used as the Created by Independent Third Party:
method of attachment.
1956.3 Heritage A dimensional asphalt-shingle.
Limits of Use Certification Agency Certificate
Approved for use in E41 ._CA� FL1956 !211 C i1a� ddf
HVHZ:No FL1956 R12 C CAC UL certification 10-11-12.adf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A f.L19-56 R12 11 H%itaae D F 1 P,-aop inst'adf
Other:Asphalt shingles11956 R1?i� r'rltMa F app iQst.;p_4f
shall be used only.on roof EL19S6 P7� ti r Rage T apo inst:odf
slopes of 2:12 or greater. Verified By:Robert].M.Nleminen FL 59166
Nails must be used as the Created by Independent Third Party:No
method of attachment. Evaluation Reports
Created by Independent Third Party:
1956.4 1 Heritage 30 A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in 1= 1956 R12 C CAC FL1956 R13_C CAC Tamko Sery Conr FL 1956 2015.L+df
HVHZ:No FLI956 R12 C CAC UL certification 10-11-12,pdr
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A FL1956 R12 11 0 dtaoe 30 aap in,—, april 10.0f
Other:Asphalt shingles FL1956 R12 11 heritage 30app_irlst rprfl SD.ptlf
shall be used only on roof Verified By:Robert Nieminen PE 59166
slopes of 2:12 or greater. Created by Independent Third Party:No
Nails must be used as the Evaluation Reports
method of attachment. Created by Independent Third Party:
1956.5 Heritage 50 A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in _1956 RIZ r_ (. C FL1 25 R 1.C aC TArnlL rry Conf FL 1956 2QJ
HVHZ:No FI,1956 RI2 C CAC U" certification 10.11-12.0f
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A FL1956 R12 I7 heritage 50 app Inst april 1O,odf
Other:Asphalt shingles FL1956 R12 IT heritage 50 app Inst f wfil 10.pd
shall be used only on roof Verified By:Robert Nieminen PE 59166
slopes of 2:12 or greater. Created by Independent Third Party: No
Nails must be used as the Evaluation Reports
method of attachment. Created by Independent Third Party:
http://vvtvnv.floridabuilding.org/pr/pr_app_dtl.aspx?param=wG EVXQwtDgs%2finGFoyT6... . 3/23/2416
Florida Building Code Online Page 3 of 4
1956.6 1 Heritage Premium A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in FL 956 R.2_'-- CAC FL1456 R11 C CAC Taro SerV Conf FL 1955 2015 )df
HVHZ:NoFL056 E12 C C (� L ce
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:NIA Installation Instructions
Design Pressure:N/A FL1956-R12 II Heritage PreMiUrn
Other:Asphalt shingles LAL)p insL od j
shall be used only on roof FLI56 R12 11 Heritagg Prprniurrj T apu ipst-odf
slopes of 2:12 or greater. Verified By:Robert Nleminen 59166
Nails must be used as the Created by Independent Third Party:No
method of attachment, Evaluation Reports
Created by Independent Third Party:
1956.7 Heritage Vintage A heavy weight dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in FL19 6 R12 C CrC F, Q- Rl:.__Q :AC
HVHZ:No FL1956 R1' C r AG if[ zh1nMAMAtrjXj3df
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A FL1256 R!2 11 Heritaop VintaqE, apy inst,odf
Other:Asphalt shingles Verified By:Robert 3.M.Nieminen PE 59166
shall be used only on roof Created by Independent Third Party:No
slopes of 2:12 or greater, Evaluation Reports
Nails must be used as the Created by Independent Third Party:
method of attachment.
1956.8 Heritage Vintage -Hip and ridge shingles
12 X 12 Hip and
Ridge
Limits of Use Certification Agency Certificate
Approved for.use in I9 6 gig C CAC Fl_1956_Rll C A_C_j4Mk�,,1r�CqnLEL q �2 5
_91 _J.5C)_ CLI f
HVHZ:Nof
Approved for use outside Quality Assurance Contract Expiration bate
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A i"12M RIZ 11
Other.Asphalt shingles Verified By:Robert J.M.Nieminen PE 59166
shall be used only on roof Created by Independent Third Party: No
slopes of 2:12 or greater. Evaluation Reports,
Nails must be used as the Created by Independent Third Party:
method of attachment.
1956,9
1956.9 Heritage A dimensional asphalt shingle,
Woodgate
Limits of Use Certification Agency.Certificatia
Approved for use in &M-6�11 C _1C_CAS_—Ta nak�q�;e C o Lif L 9 0
HVHZ:No �5 d
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A FL1,956 R12 It Her"ta e W od - g Q ;4nn inct nrif
Other:Asphalt shingles FL1956 k12 11 Heri awA Vin ri e-
shall be used only on roof Verified By:Robert Nieminen 59166
slopes of 2:12 or greater. Created by Independent Third Party;No
Nails must be used as the Evaluation Reports
method of attachment. Created by Independent Third Party.:
1956.10 Heritage XL A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in EU_95LM_L_(!_CAC_EL_j256 aij
HVHZ.No FL55R!2_g;
_&AC
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ.,Yes 09/1712018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A EL1956.,R12 11 111_21itaile xi 3PP Mst d M-ii Modf
Other:Asphalt shingles FL-1956 R12 11 h_-ritaae xi ann inst, f aoril jo.pdf
shall be used only on roof Verified By:Robert Nleminen PE 5*9166
slopes of 2:12 or greater. Created by Independent Third Party:No
Nails must be used as the Evaluation Reports
method of attachment. Created by independent Third Party:
F71956.11 Hip and Ridge Hip and ridge shingles
gi Ridge
Shingle,
Limits of Use Certification Agency Certificate
Approved for use in FL12UI C
_Aj� C nf
HVHZ:No F .956 R12 C r"AC UL certification IO-11 12 ndF
http://wv"v.floridabuilding.org/pr/pr—avi)—dti.aspx?pa-ramz=-*VGEVXQwtDqs�/�2fmGFOYT6... 3/23/2016
Florida Building Code Online Page 4 of 4
Approved for use outside Quality Assurance Contract Expiration Date
HVMZ:Yes 09117/2018
Impact Resistant;N/A, installation Instructions
Design Pressure:N/A
_R: L paf
Other,Hip and Ridge Fl-•1956 RI 2 L
shingles shall be used only EL1956 R12 11_12-1-4X12 HjuRidge Sealant Dab JIlu5trahon$,pd
on roof slopes of 2:12 or 11141956 Rig 11 12L(I2 Hir)Rldge Sealant Dab Illustrations.cia
greater,Nails must be used Verified By:Robert Nieminen 59166
as the method of Created by Independent Third Party:No
attachment. j Evaluation Reports
Created by Independent Third Party-
Cent=U ::1949 North fvlonrcie Streilt.Laine *IN F-L 32349 Phone:850-487-142
The State of Florida is an AA/EEO employer.q02MMt 2007.2013 State of'Floncia.::Privacy Ratemen ::Accessi6'10 Statement::Refund Statement
Under Florida law,email add ressez are public records.If You do not want your a-mall address releasod in response to a public records request,d I o not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail,if you have any quL-AiGnS,Please contact:$50.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email addn�—s if
they have one,The entails provided may be used for official communication with the licensee.However email addresses,are public record,If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine it you are a licensee under
Chapter 455,F.S.,please dick ftaIl_.
Product Approval Accepts:
=W. rr M
http://Nvww.floridabuilding-.Org/pr/pr app dtl.aspx?param=WGE
VXQwtDqs%2fmGFoyT6... 3/23312016
Application lnsimcdons for
TAMK0.1H 11TAGE6 30
BUILDING PItIDDilCTG 16AMINATED ASPHA1a,T SNINti1.SS
Dallas, TX • Tuscaloosa, AL • Phillipsburg, KS • Joplin, MO
THESEARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.
TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING
FROM FAILURE TO'FOLLOW THE MANUFACTURER'S INSTRUCTIONS.
THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER.
IN COLD WEATHER(BELOW 40°F),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES.
IMPORTANT:It is not necessary to remove the plastic strip from the back of the shingles.
1.Boor BECK 3.FASTENERS
These shingles are for application to roof decks capable of receiving WIND CAUTION: Extreme wind velocities can damage these
and retaining fasteners,and to inclines of not less than 2 in.per foot. shingles after application when proper sealing of the shingles
For roofs having pitches 2 in.per foot to less than 4 in.per foot,refer does not occur.This can especially be a problem if the shingles
to special instructions titled"Low Slope Application".Shingles must are applied in cooler months or in areas on the roof that do not
be applied properly.TAMKO assumes no responsibility for leaks or receive direct sunlight.These conditions may impede the sealing
defects resulting from improper application,or failure to properly of the adhesive strips on the shingles.The inability to seal.down
prepare the surface to be roofed over. may be.compounded by prolonged cold weather conditions and/
NgYV ROOF DECf(CONSTRUCTION:Root deck must be smooth, or blowing dust.In these situations,hand sealing of the shingles is
dry and free from warped surfaces. It is recommended that metal recommended.To insure immediate sealing,apply 4 quarter-sized
drip edges be installed at eaves and rakes. dabs of TAM-PRO'"Premium SBS Adhesive or TAMKO Tam-Seal
Adhesive on the back of the shingle 1 in.(25mm)and 13 in.(330mm)
PLYWOOD:All plywood shall be exterior grade as defined by the in from each side and 1 in. (25mm) up from the bottom of the
Engineered Wood Association.Plywood shall be a minimum of 3/8 shingle.Press shingle firmly into the adhesive.For maximum wind
in.thickness and applied in accordance with the recommendations resistance along rakes,cement shingles to the underlayment and
of the Engineered Wood Association. each other in a 4 in.(102mm)width of TAM-PRO SBS Adhesive or
SHEATHING BOARDS: Boards shall be well-seasoned tongue- TAMKO Tam-Seal Adhesive. Caution:Apply ONLY a thin uniform
and-groove boards and not over 6 in.nominal width.Boards shall layer of adhesive less than 1/8 in.(3mm)thick.Excessive amounts
be a 1 in. nominal minimum thickness. Boards shall be properly can cause blistering of the shingles and may soften the asphalt in
spaced and nailed. certain underlayments resulting in the asphalt flowing,dripping and
staining.Shingles must also be fastened.according to the fastening
8.VENT"TION Instructions described below.
Inadequate ventilation of attic spaces can cause accumulation of Correct placement of the fasteners is critical to the performance
moisture in winter months and a build up of heat in the summer. of the shingle. If the fasteners are not placed as shown in the
These conditions can lead to: diagram and described below,this will result in the termination of
TAMKO's liabilities under the limited warranty.TAMKO will not be
1.Vapor Condensation responsible for damage to shingles caused.by winds in excess of
2.Buckling of shingles due to deck movement. the applicable mph as stated in the limited warranty. See limited
warranty for details.
3.Rotting of wood members.
FASTENING PATTERNS:Fasteners must be placed 6-1/8 in.from
4.Premature failure of roof, the bottom edge of the shingle, penetrating through the common
bond,and located horizontally as follows:
To insure-adequate ventilation and circulation of air,place louvers
of sufficient size high in the gable ends and/or install continuous 1)Standard Fastening Pattern.(For use on decks with slopes 2 in.
ridge and soffit vents. FHA minimum property standards require per foot to 21 in.per foot.)One fastener 1 in.back from each end
one square foot of net free ventilation area to each 150 square feet and one 13-1/2 in.back from each end of the shingle for a total of 4
of space to be vented,or one square foot per 300 square feet if a fasteners.(See standard fastening pattern illustrated below).
vapor barrier is installed on the warm side of the ceiling or if at least
one half of the ventilation is provided near the ridge.If the ventilation STANDARD FASTENING PATTERN
openings are screened,the total area should be doubled. FASTENERS NAIL ZONE
COMMON
BOND
IT IS PARTICULARLY IMPORTANT TO PROVIDE
ADEQUATE VENTILATION. exPoSURE 6-6r8"
L
12-1121—+—12-3/8"-+ya— 12-112--- h--1"
(Contlnued)
Central District 220 West 4th St.. Joplin,MO 64801 800-641-4691 11/09
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tatTlkO.COm. Southwest District 7910 S.Central Exp.. Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 1
-. r- -
ZZ
CD (CONTINUED from page 1)
TAMKO BER'TAGE" 30
BUILDING PRODUCTS 6AlNINATEN ASPHA6T SHINGLES
Dallas, TX • Tuscaloosa, AL ® Phillipsburg, KS • Joplin, MO
2) Mansard Fastening Pattern. (For use on decks with slopes be a minimum of 1-1/4 in. for new construction and 1-1/2 in. for
greater than 21 in.per foot.)One fastener 1 in,back from each end reroofing thus allowing a minimum deck penetration of 3/4 in.The
and one fastener 8-1/2 im back from each end and one fastener 16 crown of the staple must be parallel to the length of the shingle.
in.back from each end for total of 6 fasteners per shingle. (See The staple crown should be driven flush with the shingle surface.
Mansard and High Wind Fastening Pattern illustrated below.) Staples that are crooked,underdriven or overdriven are considered
MANSARD AND HIGH WIND FASTENING PATTERN improperly applied.
FASTENERS _ NAIL ZONE Property Driven Improperly Driven
COMMON
BOND Si off Im.��vr!Ir¢n overarrven taaoked
�
h�gles
&18" D i
FESURE5-518'
i�7.12'�-T•12'-►�0-T-316"-►(�-7-12°-►}�'7-1/2"-�I �1" i, ma
3) High Wind Fastening Pattern. (For High Wind Application C_f4!>r M ALL FASTENERS MUST BE DRIVEN INTO THE NAIL
requirements)One fastener 1 in.back from each end.One fastener ZONE/COMMON BOND AS SHOWN IN THE DIAGRAM ABOVE.
8-1/2 in.back from each end and one fastener 16 in.back from each 4.ONDERWIYNENT
end fora total of six(6)fasteners per shingle,In addition to this shingle
fastening pattern requirement for High Wind Application,TAMKO UNDERLA MENT:An underlaymerit consisting of asphalt saturated
also requires the use of the following TAMKO products:TAMKO felt must be applied over the entire deck before the installation of
felts or underlayments;TAMKO Moisture Guard Plus underlayment TAMKO shingles.Failure to add underlayment can cause.premature
at all eaves,rakes,and valleys;TAMKO or TAM-PRO cements and failure of the shingles which is not covered by TAMKO's limited
coatings products where required:TAMKO ventilation where required, warranty.Apply the felt when the deck is dry.On roof decks 4 in.
TAMKO starter shingles if available in area,and TAMKO Hip and Ridge per foot and greatecapply the telt parallel to the eaves dapping each
shingles installed on all hips and ridges.Along rakes,cement shingles course of the felt over the lower course at least 2 in.Where ends
to the underlayment and each other in a 4 In.(102 mm)width of TAM- join, lap the felt 4.in. If left exposed, the underlayment felt may
PRO SBS Adhesive or TAMKO Tam-Seal Adhesive.Also,see local be adversely affected by moisture and weathering. Laying of the
building codes for proper nailing application.High Wind Application underlayment and the shingle application must be done together.
is offered on new constructionor complete tear-off applications only. Products which are acceptable for use as underlayment are:
It is not offered for recover applications. If High Wind Application
requirements are not followed,the High Wind Application Warranty - TAMKO No.15 Asphalt Saturated Organic Felt
MPH, as stated on Table I in the Limited Warranty, reverts to the - A.non-perforated asphalt saturated organic felt which meets
Standard Application Wind Warranty MPH limit.(See Mansard and ASTM:D226,Type I or ASTM.D4869,Type I
High Wind Fastening Pattern Illustrated above.) - Any TAMKO non perforated asphalt-saturated organic felt
- TAMKO TW Metal and Tile Underlayment,TW Underiayment
NAILS;TAMKO recommends the use of nails as the preferred method and Moisture Guard Plus'(additional ventilation may be
of application. Standard type roofing nails should be used. Nail required.Contact TAMKO's Technical Services Department
shanks should be made of minimum 12 gauge viire,and a minimum for more information.)
head diameter of 3/8 in.Nails should be long enough to penetrate
3/4 in.into the roof deck.Where the deck is less than 3/4 in.thick, In areas where ice builds up along the eaves or a back-up of water
the nails should be long enough to penetrate completely through from frozen or clogged gutters is a potential problem, TAMKO's
plywood decking and extend at least 1/8 in.through the roof deck. Moisture Guard Plus'waterproofing underlayment(or any specialty
Drive nail head flush with the shingle surface: eaves flashing product) may be applied to eaves, rakes, ridges,
valleys, around chimneys, skylights or dormers to help prevent
°°'"'°""a" t°° P°"gOn"" water damage:Contact TAMKO's Technical Services Department
ys^mtaat°n+ae. uneenfdven ovarddvan eroWxA for more information.
AsphA
s�ta� TAMKO does not recommend the use of any substitute products
DMkUV as shingle underlayment.
�,S nammet S.APPLICATION INSTRUCT110NS
fka'J1U•�fxtA p!aetntlan. InodaQllaia tan aMr;CUl4 inaelryu°Ie
Imo Itilch rLLh rhing4 curtxa panotration °�t+ta4� otxran9° ST_AF E8 COURSE:A starter course may consist of TAMKO Shingle
Starter,self-sealing 3-tab.shingles or a 9 inch wide strip of mineral
STAPLES:df staples are used in the attaching process,follow the surface roll roofing.If self-sealing 3-tab shingles are used,remove
above instructions for placement.All staples must be driven with the exposed tab portion and install with the factory applied adhesive
pneumatic staplers.The staple must meet the following minimum adjacent to the eaves. Attach the starter course with approved
dimensional requirements.Staples must be made from a minimum fasteners along a line parallel to and 3 in.to 4 in.above the eaves
16 gauge galvanized wire.Crown width must.be at least 15/16 in. edge.The starter course should overhang both the eaves and rake
(staple crown width is measured outside the legs).Leg length should edges 114 in.to 3/8 in.
(ContinuetQ
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 nx�
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.COm Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 °�
6 (CONTINUED from page 2)
TAMKO I HER1TAGW 30
I;O16DING PRODUCTS U.1,11NATED ASPHALT.SHINGLES
Dallas, TX •Tuscaloosa,AL • Phillipsburg, KS • Joplin, MO
SHINGLE AEPLiCATION:Start the first course with a full size shingle S.LOW SLOPE APPLICATION
and overhang the rake edge 1/4 in.Cut 10-378in.from a full shingle On pitches 2 in.per foot to 4 in.per foot cover the deck with two layers .
to form a shingle 29{n.long,Use this to start the second course(see of asphalt saturated felt.Begin by applying the felt in a 19 in.wide strip
diagram below).Cut a 23 in:long shingle to start the third course.Use along the eaves and overhanging the drip edge by 1/4 to 3/4 in.Place
the remaining 16-3/8 in.piece of shingle to start the fourth course and a full 36 in,vide sheet over the 19 in.wide starter piece,completely .
use the remaining 10-3/8 in.piece to begin the fi th course.Continue overlapping it-All succeeding courses will be positioned to overlap the
up the yake In as many rows as necessary using the same formula preceding course by19 in.If winter temperatures average 25eF or less,
as outliner)above.The butt of the shingle should be aligned with thoroughly cement the felts to each other with TAM-PRO or TAMKO
the top edge of the sawtooth of the underlying shingle for a 5-5/8 in. Plastic Roof Cement from eaves and rakes to a point of a least 24 in.
exposure(see shingle application drawing illustrated on this,paneQ. inside the interior wall line of the building.As an alternative,TAMKO's
When you make your final cut at the roof's edge,flip any pieces that Moisture Guard Plus-"self-adhering waterproofing underlayment may
are 8 In,or longer back onto the roof.These pieces can be worked be used in lieu of the cemented felts.
in anywhere without creating zippers or color variations.
NOTE:Do not,align joints of shingle courses when working in cut 7'MANSARD ROOF OR STEEP SLOPE 800F
pieces.Joints should be no closer than 4 in.from one another. If the slope exceeds 21 in.perfoot(60),each shingle must be sealed with
TAM-PRO SBS Adhesive or TAMKO Tam-Seal Adhesive immediately
upon installation.Spots of cement must be equivalent in size to a$.25
piece and applied to shingles with a 5-5/8 in.exposure,use 6 fasteners
i to-als" per shingle.See Section 3 for the Mansard Fastening Pattern.
I a.BE-ROOFING
cours" - _ to-�e �u Before re-rooting,be certain to inspect the roof decks.All plywood
23"_' shall meet the requirements listed in Section 1.
Nail down or remove curled or broken shingles from the existing
: 11tsars": roof.Replace all missing shingles with new ones to provide a smooth
rake - Fuu base, Shingles that are buckled usually indicate warped decking
t0 318" or protruding nails. Hammer down all protruding nails or remove
them and refasten in a new location. Remove all drip edge metal
slh course _ •, y8,3/8" and replace with new.
41h course
if re-roofing over an existing roof where-now flashing is required
3rd course 3" 1 to protect against ice dams(freeze/thaw cycle of water and/or.the
2nd course asw . backup of water in frozen or clogged gutters),remove the old.rofing
to a point at least 24 in. beyond the interior wall line and apply
tst cwres Fu11 10-318• TAMKO's Moisture Guard Plus,waterproofing underlayment.Contact
CRY, TAMKO's Technical Services Department for more information.
Measurements will varywhen nesting over an existing 5 in.exposure
single roof:Call TAMKO Technical Services for further information.
CW,—kat a:+rsa,+:^ykr.a ma+e:3•w4 a 10111
1.1-wi C.A. qie W re W J;Q1, The nesting.procedure described below is the preferred method for
reroofing over existing metric size shingles with a 5-5/8 in.exposure.
See description belom
71, rn a a. StarterComer se:Remove the tabs and an additional portion from the
head of a full size shingle so that its height is equal'to the exposure
of the existing shingles.Position the resulting strip over the existing
roof edge(with the factory-applied adhesive strip along the eaves).
Cut approximately 6 in.from the rake end and apply the remaining
,, ~l portion at the eaves.Continue the starter strip by applying full length
shingle strips cut to height as.above.evenly along the existing roof
at the eaves.The existing roof should overhang the eaves far
2.r�,�,wt"zs,a•.1oa•n-�r�+og�1:>.,ua. enough to carry Water off into the gutter.If this Is not the case,
A',%can tae.+urcaer"my-m+"n arts cut and apply the starter strip so that it will provide sufficient
. ka lna.u.rvs
overhang for proper drainage.
3ron°�'""" °'"a "°°'" ` °"" "`"" rrst r Remove an amount from the butt edge of a full-size
.:.."M^n. gra ;. .,,.r +a ^"e ar>�w E_�4�, g
shingle so that the remaining portion of the shingle fits between the
NOTE:C. d 0 lame W=^^oras="t.._%i.01. butts of the existing third course.This course must also be applied
lid pie4ea.dn.wl Otdd Qe Im r4eeer WD4't d e_a.rorna.
evenly along the eaves edge of the new starter strip.
(continue6)
Central District 220 West 4th St., Joplin,MO 64801. 600-641-4691 i uos
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 .800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.eorn Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 `3
®�I G) (CONTINUED from page 3)
TAMKO HERITACCO 30
BUILDING PRODUCTS 16AMINATED ASPHALT SHINGLES
Dallas,TX •Tuscaloosa, AL • Phillipsburg, KS • Joplin, MO
Second and Succeeding Courses: Remove 10-3/8 in, from the FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE
rake end of the first shingle in the second course, and continue CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT.
with full width shingles for the remainder of the course, placing
the top edge of each new shingle against the-butt edge of the old �aty«Kne me
r>�r2a-yf
shingle in the course above.This method should create an exposure of r>,il FrtSt.Moi:hea � Estrn rau
of 5-5/8 in,after the first course.When beginning the succeeding C.,ad Pou5 or 50 tc.
or heavrrr,."rtmTsYj� % anti a!ci5r_vyo
courses continue to follow the Heritage application instructions. ;�_ � x
(See section 5). valioy° wUn"
ri r
Existing shingles,„
♦. `' - Urdatay—I �� No fasteners urchin
{... \r `731/4 1'f > 1�714h}
Y$174r-
V 41
Drip edge,'
1 Pi au tip of S1.4,c ate vg*
't � / `\ \\ r� Ilre—tical stn h,2 lncixrs bask
r„ i \tr \” r "Drip edge rrem'alley ce a lin wct co,,r6+g
..i ,`•�, 4, / a,e wtical sun;:e.
New shingles'
exposure 10.DIP AND RIDGE FASTENING.DEVAIL
exposure
Apply the shingles with a 5 in.exposure beginningat the bottom
f I of the hip or from the end of the ridge opposite the direction of the
9.GALLEY APPLICATION prevailing winds.Secure each shingle with one fastener on each side,
5-112 in.back from the exposed end and 1 in.up from the edge.
Over the shingle underlayment,center a minimum 36 in,wide sheet TAMKO recommends the use of TAMKO Hip & Ridge shingle
of TAMKO Nail-Fastt,,Moisture Guard Plus'or a minimum 50 Ib.roll
roofing in the valley.Nail the felt only where necessary to hold it in Products.Where matching colors are available,it is acceptable to
place and then only nail the outside edges. use TAMKO's Elite Glass-Seal shingles cut down to 12 in.pieces.
I NSP RTAMT:PRIOR TO INSTALLATION WARM SHINGLES TO Fasteners should be 1/4 in.longer than the one used for shingles
PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING IMPORTANT. PRIOR TO INSTALLATION, CARE NEEDS TO BE
SHINGLES TO FORM VALLEY. TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE
After valley flashing is in place: BENDING SHINGLE IN COLD WEATHER.
• Apply the first course of shingles along the eaves of one of the Direction of prevalling wind
intersecting roof planes and across the valley. Start s°exposure
Note:For proper flow of water over the trimmed shingle,always here- N t
start applying the shingles on the roof plane that has the lower / '.-. �
slope or less height. :'ri. �\i-, Fastener
' i1
• Extend the end shingle at least 12 in.onto the adjoining roof. I Start
Apply succeeding courses in the same manner,extending them here 5e exposure
across the valley and onto the adjoining roof.
Press the shingles tightly into the valley. THESE ARE THE MANUFACTURER'S APPLICATION
• Use normal shingle fastening methods, INSTRUCTIONS FOR THE ROOFING CONDITIONS
DESCRIBED.TAMKO BUILDING PRODUCTS, INC.ASSUMES
Note-No fastener should be within 6 in,of the valley centerline, NO RESPONSIBILITY FOR.LEAKS OR OTHER ROOFING
and two fasteners should be placed at the end of each shingle DEFECTS RESULTING FROM FAILURE TO FOLLOW THE
crossing the valley. MANUFACTURER'S INSTRUCTIONS.
• To the adjoining roof plane,apply one row of shingles vertically
facing the valley and 2 in.back from the valley centerline.
Note: For a neater installation, snap a chalkline over the tradernar sof stureTAM Guard Plus•Nail s,IM.nc.TAM-PROD and He dageJ are registered
P lradentarks o!TAMKO Building Products,Inc.
shingles for guidance. Informatlon Included in these application instruc4ons vias current at time of printing.To
• To complete the valley,apply shingles on the adjoining roof obtain a copy of the most current version of these application Instructions,visit us online
plane by positioning the tip of the first shingle of each row at at tamtm.com or call us at 800.641.4691.
the 2 in.point from the centerline where the edge of the vertical
shingle has been applied,covering the vertical shingle.
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11109
Visit Out Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 4