HomeMy WebLinkAboutPRODUCT APPROVALFLORIDA OqFA�'Ny 0'
Business & Professional Regulation
J_ r
11,,,,1 D""r"T�(d SCIS Home I Log In I User Registration I Hot Topla ! Submit Surrharge I Stats & Fads Publications FBC Staff SCIS site Map Links Search
Pro s ss�i(h
Professi l Product Approval
USER: Pudic User
Regulation
®Product Aoomval Menu > Pnaoud or Aooilotion Search > Aoolication List > Application Detall
E 3y:L�4:ti� FL * FL10674-R12
Application Type Revision
Code Version 2014
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscornlng.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE -59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/20/2017
Validated By John W. Knezevich, PE
� Validation Checklist - Hardcopy Received
Certificate of Independence FL10674 R12 COI 2016 01 COI Ni min n odf
Referenced Standard and Year (of Standard) Standard Vear
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date
Submitted
04/18/2016
Date
Validated
04/19/2016
Date
Pending FBC Approval
04/20/2016
Date
Approved
06/08/2016
Summary of Products
FL #
Model, Number or Name
Description
10674.1
Owens Corning Asphalt Roofing
3 -tab, 4 -tab, 5 -tab, laminated, starter and hip & ridge
Shingles and Starters
shingles
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10674 R12 If 2016 04 FINAL ER OC ASPHALT
Approved for use outside HVHZ: Yes
SHINGLES FL10674-R12.Ddf
Impact Resistant: N/A
Verified By: Robert J. M. Nieminen PE - 59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER, Section 5.
Evaluation Reports
FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT
SHINGLES F1.10674-1112 odf
Created by Independent Third Party: Yes
Back NBYt
Contact Us :: 1940 North Mcnroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coovrioht 2007-2013 State of Florida.:: Privacv Statement :: Accessibility Statement :: Refund Statement
Under Flodda law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section
455.275(1), Flodda Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do net wish to supply a
personal address, please provide the Department with an email address which on be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please dick here-.
Product Approval Accepts:
Credit Card
SAFEI
TRINITY ERD
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization 49503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report 037940.02.12-R7
FL10674-R12
Date of Issuance: 02/06/2012
Revision 7: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E. "-,-%,%. ""', P.E.nThe simlles2016.Thisdgwas snotsrveastlbyRobertNieminen,
..V 4�'(p � P.E. m nt. Signed,
Thisdhardotserveve an been
itlly tedtotd
Florida Registration N0. 59166 Florida DC4ANE1983 ='�"""'I"" tlocument.Signed, sealed hardcoples have beentransmMetl to the
product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TTRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Prope
Standard
Year
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2009
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2009
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2008
3. REFERENCES:
Entity Examination Reference Date
UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol.3 02/15/2007
UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012
UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC (TST9628) Physical Properties Classification letter 02/13/2014
UL LLC (TST9628) Physical Properties Classification letter 10/02/2015
Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation, R2453 Exp.08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme are fiberglass reinforced, 3 -tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced, 4 -tab asphalt roof shingles.
4.1.3 DevonshireT" are fiberglass reinforced, 5 -tab asphalt roof shingles.
4.1.4 Duration*, TruDefinition Duration, Duration Premium Cool, TruDefinition Duration Designer Color
Collection, TruDefinitionOakridge, Oakridge and WeatherGuard' HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard* HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidgeT" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity(ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R7
Certtf7cate of Authorization #9503 FL10674-R12
Revision 7:04/18/2016
Page 2 of 9
E
�I I KINITY ERD
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to V,ad = 150 mph (Val, = 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified
in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F. indicating the shingles are
acceptable for use in all wind zones up to Vaad = 150 mph (Vali = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations. Contact
the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61G20-3.
INSTALLATION:
6.1 Underlavment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6_2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
➢ Berkshire shingles require minimum five (5) nails per shingle.
➢ WeatherGuard HP shingles require minimum six (6) nails per shingle.
➢ Devonshire" shingles require minimum six (6) nails per shingle.
Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing— Starter Strip Shingle and Starter Strip Plus:
Felt undedayment
Drip edge
Nails located
2 -3" from eave
eave
6"removed
Starter Strip shingle overhangs eaves and rekea'/."-Yi
Exterior Research and Design, U.C.
Certificate ofauthori:ation #9503
Srx-ssakng adhesive
positioned olong save
Plus overhangs eaves and cakes 11V -31V
Evaluation Report 037940.02.12-R7
FL10674-R12
Revision 7:04/18/2016
Page 3 of 8
6.2.6 Minimum Nailing —Classic®&Supreme:
Normal Mansard or Aro. porn
Wind Areas Nigh Wind desvenes y
Area pan ulnas, nmol,# Areas vientos ruertes
Fr
t•
6• Ex"re
E#pwidi6n
6.2.7 Minimum Nailine— Berkshire®.
Standard Fastening Pattern
TTRINITY ERD
Normal Mansard or Ana para
Wind Areas High Wind desWnas y
Ane pen vientos norneles Ar... Hants, fuems
r IA) t' t• z• Igl x. t.
t
6 618• Exposure
Exposial6n
N
See lent strip
V 6s de sdlador
eh I I'll,I S
6 -Nail Fastening Pattern
rvidnsdra ur xeep mope rastemng rauern
Exterior Research and design, I.I.C. Evaluation Report 037940.02.12-R7
Certificate of Authorization #9503 FL10674-R12
Revision 7: 04/18/2016
Page 4 of 8
6.2.8 Minimum Nailing—Devonshire'":
1„ 7" 1 8„ 8" i 8„ 7"
ShcB'exposure
Exposition de 5 -518 pulp Sealant location
Uhieacion del sell dor
Standard 6 -Nail Fastening Pattern
(TTRINITY ERD
Nags
r r
Ten 1" Spots of As hah Roof Cement
Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duratione, TruDefinitione Duration, Duration® Premium Cool & TruDefinitions Durations
Designer Color Collection:
4-11811 Fastening Pattern
9xanYlOM1tYN,q nu wqN
rxa. rypa
Standard Fastening Pattern
pas Greater Than 21:12
r x.e. ryP a
Mansard or Steep Slope Fastening Pattern
o -Nail rasiening vattern
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R7
CertiJieote of Authorization #9503 FL1G674-R12
Revision 7:04/18/2016
Page 5 of 8
6.2.1 Minimum Nailing—TruDefinitiona0akridge®, Oakridge°:
4 Nall Pattern
Esquiana con 4 clavus
t- t.
Imo— ,r —N I<— ,s —>►I
66/8" Exposure6 sts" Exposure
ExpWcl6nd166/B ulg. nails
P Clavus Expos(ddnM 66/8pd8
Standard Fastening Pattern
n -
(TTRINITY RINIIY ERD
6 Nall Pattern
Esquatat ton 6 clavus
r r
651W Exposure to 66/8"E re�
Expoudkin de 66/Bpu/g. Exposidon Ge 66/8pulg.
xa Greater Than 21:12
funXYW tuYnl�q eN wpq
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
6 -Nail Fastening Pattern
VA.&tatrind
Rlarer
ChM en b fLer 6 f=
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R7
Cc16fk.tI ul authorization #9503 FL10674-R12
Revision 7:04/18/2016
Page 6 of 8
\l TRINITY I ERD
6_3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard* HP Hip and Ridge Shingles and
ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four
(4) nails per shingle. Installation of DuraRidgeTM Hip & Ridge Shingles shall comply with the manufacturer's
current published instructions, using two (2) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand -sealing for wind
warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge:
6.3.4 Minimum Nailing— WeatherGuardd HP Hip and Ridge:
Fig. A
vn wE wba
t—dlMbn
Wlk
I I i i
AP i i I I
I
Exterior Research and Design, LLC. Evaluation Report 037940.02.12•117
certificate of Authorization #9503 FL10674-R12
Revision 7:04/18/2016
Page 7 of 8
6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles:
PrevaAing
Wind Direction s b,, Strip
A� 8' EKPown -
7'h'
(T�RINJTY ERD
Standard
Fastening
Pattam
1Y
Salmt
7 h'
8' Eapnun
6.3.6 Minimum Nailing — DuraRidgeT" Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
P..R p Wild Dlr.d.
~ Dim da+limnen onr
Di.mtndeh� pr.Idorniiama
aWE I I
ol� M I I
I I
I I
I I
Kr=
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC— QUA9625 ; (414) 248-6409; karen.buchmannoul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R7
Certificate of Authori:atlon #9503 FL10674-R32
Revision 7: 04/18/2016
Page 8 of 8