HomeMy WebLinkAboutProduct Approval Certificate of Authorization No. 29824
CREEK 17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT 2014 FLORIDA BUILDING CODE
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued February 23, 2015
1 Owens Corning Parkway
Toledo, OH 43657
(800)438-7465 `� fes'
www.owenscorning.com ( � pVt:.,a
Manufacturing Plants: Atlanta, GA SEP 1 20%Compton, CA
Denver, CO
Irving,TX PERMITTING
Kearny, NJ St. Lucie County, FL
Medina, OH
Memphis,TN
Portland, OR
Summit, IL
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1507.2.5, 1507.2.7.1
Properties: Physical properties,Wind Resistance
REFERENCES
Entity Report No. Standard Year
UL LLC(TST9628) 13NK05962 ASTM D 3462 2009
UL LLC(TST9628) 13NK05962 ASTM D 3161 2009
UL LLC(TST9628) 13NK05962 ASTM D 7158 2008d
UL LLC(TST9628) 13NK05962 TAS 100 1995
UL.LLC(TST9628) 13NK05962 ASTM G 155 2005a
UL LLC(TST9628) 13NK05962 AC438 2011
PRODUCT DESCRIPTION AND APPLICATION
SUPREME®& ASTM D 3161, Class F &ASTM D 7158, Class H fiberglass reinforced, 3-tab asphalt
CLASSIC® roof shingle. Unless otherwise noted, the following application details shall be followed
for New and Existing construction.
Basic Wind Speed: Max. 194 mph
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min.7/16 in. OSB existing construction.
Underlayment: In accordance with FBC and manufacturer's requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Contact
the OWENS CORNING when installing at slope greater
than 21:12.
Installation: Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Nailing requirements are detailed below in
Figures 1 &2.
OCR13001.1 FL 16638-R1 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
D OWENS CORNING ROOFING AND ASPHALT LLC
jZEEK Asphalt Shingles
TECHNICAL SERVICES, LLC
36°
Min.12 ga.corrosion resistant roofing-nail
With'min.316°:diameter head `
11"
1.
V.
'continuous,factory-applied tab,sealant_
12'
Figure 1. SUPREME®and CLASSIC®
4 Nail Pattern
.36",.
10" Min:12:ge,corrosion msistant roofing nail
1" 2.. with m n:378"diameter head
1"
Continuous;factory=applied.tab.sealant
o -b O O O 12,
5 6I6- 5„
Figure 2. SUPREME®and CLASSIC®
6 Nail Pattern
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) This evaluation report is not for use in the HVHZ.
3) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
5) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
6) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
detail shall prevail.
7) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
OCR13001.1 FL 16638-R1 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEKD jj OWENS CORNING ROOFING AND ASPHALT LLC
i 1 Asphalt Shingles
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the 2014 Florida
Building Code as evidenced in the referenced documents submitted by the named manufacturer.
2015.02.2
c E Ns��Fs- -` 3 14:42:17
No 74021
*: -05'00'
X13 STATE OF 441 Zachary R. Priest, P.E.
i0, .'.•A, Q Florida Registration No.74021
--i-F O R 1 • •�j� ` Organization No.ANE9641
�nn�►
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR13001.1 FL 16638-R1 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.