Loading...
HomeMy WebLinkAboutEngineering i I PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone(772) 785 -9888 Email pwelchinc@aol.com August 25,2016 Re: Salopek Re-Roof 10725 S. Ocean Drive Unit 275 i Jensen Beach,FL 34957 SCOPE OF WORK: Remove existing roofing and install new 5-V Crimp Metal Roof(Gulf Coast Supply& Manufacturing FL# 11651.13) at above referenced residence address over new underlayment and existing plywood sheathing. DESIGN CRITERIA: , FBC 2014 ASCE7-10 PROJECT DATA: BUILDING HIEGHT= 18' A=3' MEAN ROOF HIEGHT=<30' ROOF ANGLE=3:12 SHAPE=PITCHED HIP IMPROTANCE FACTOR= 1.00 WIND VELOCITY V ult= 165 MPH WIND VELOCITY V asd= 124 MPH EXPOSURE=D ENCLOSURE CLASS=ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF (usf1: ZONE 1 (Field)=-44.7 ZONE 2 (Perimeter/Ridge)_-75.5 ZONE 3 (Comers)_-110.8 Paul Welch Inc. Pau_1 Welch P.E. Reg.No. 29945 August 25,2016 10725 S.Ocean Drive Unit 275 Jensen Beach,FL 34957' - 1 of 4 METAL ROOFING ATTACHMENT REQUIREMENTS: Metal roofing to be attached with#9- 15 x 1 %2"long(minimum %a"penetration through plywood sheathing)Woodgrip screws with weather sealing washers spacing as follows: I ALL FASTENERS IN THE FLAT OF THE PANEL ZONE I (Field): Fasteners adjacent to ribs one side(Type 1 per product approval) at 16" O.C. ZONE 2 (Perimeter/Ridge): Fasteners adjacent to ribs one side (Type 1 per product approval) at 16" O.C. ZONE 3 (Corners): Fasteners adjacent to ribs both side(Type 2 per product approval) at 16" O.C. i Zones 1 &2 Design uplift Pressure: -94.25 psf Zone 3 Design uplift Pressure: - 131.0 psf I Zones 1 &2: 94.25 >75.5>44.7 Therefore O.K. Zone 3: 131.0> 110.8 Therefore O.K. NOTE: CONTINUOUS APPROVED LAP SEALANT MUST BE USED AT ALL PANEL SIDELAPS FOR SLOPES LESS THAN 3:12. I UNDERLAYMENT: Underlayment shall be Tri-Built Roofing Products FL# 16048.1 "Tri-Built S/A HT TU". While priming is optional, TRI-BUILT recommends priming the deck if the final roof cover is not slated for installation within 24 hours. i Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place,peel-off the release f hn diagonally while holding the membrane tight. Firmly roll the membrane into place to;achieve a bond.Horizontal seams should be minimum 3-inches, configured to shed water.Vertical seams should be 6inches and staggered not less than 2-ft from vertical seams in the course below.All-over-granule end- laps shall be sealed using either heat-welding or hot air welding techniques.-Tor Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release-paper ailiieenter sheet over valley or ridge. Drape and press sheet into place,working fron .the center of the valley Jor ridge in each direction. For valleys,apply the sheet starting at the lowest point-arid work upward. PAUL WELCH INC. MECH-ELECT-CI 10725 S.Ocean Drive Unit 275 aolviFk /r 2 of4 PORT SAINT LUCIE, FL 34984 PAUL WELCH P.E. FLA RFG NO.29945 AUS 2 5 2b16 f I I i DECK INSTALLATION: Re-nail all plywood sheathing(15/32"thick minimum)with 8D ring shank nails at 4" O.C. perimeter and 6" O.C. field for all zones. All work to be in compliance with product approval (FL# 11651.13), (FL# 10648.1), manufacturer's specifications, and the Florida Building Code 2014. I f I I I I i I ' i I I - - Paul'Welch Inc. ul:Welch:P.EReg.No. 29945 August 25 2016 10725 S.Ocean Drive Unit 275 Jensen Beach,FL 34957 -'✓^ ^`\ 3 of 4 i OAA e4 Eater 3 O I O 1 z 1 ROOF ZONE PLAN A=3' QQQ,Q=ZONE DF,SIGNA77ON(TYPICAL) NOTE: CONTINUOUS APPROVED LAP SEALANT MUST BE USED AT ALL PANEL SIDELAPS FOR SLOPES LESS THAN 3:12. - Paul Welch Inc. Paul Welch-P.E. Reg.No. 29945 -A 9-Ust25,2016 10725 S.Ocean Drive Unit 275 Jensen Beach,FL 34957 - 4 of 4 iFfBusiness & ctda:. ufs usr C3sii Professional e :Bf:LS.-3losrxx� I t=or}-�rrr I i115��-Rcais,acionI EtacTopics I :5ulvnif:5urrhara�I Sla>•,:-:t§::FacEs � !?uGti�f3uns,I .FBr:StriF � I3�.15-5iCeM3n: � .Liriks:l 5earch- Florida r b F 11+yN�(+CG'S%S E i.,,c-sral Fri!s`rn ' Product Approval Menu>Product or Application Search Application List>pprMaUacrDelaT • s£4" F1316�T-� � Code-Version, =4; .nTwt g Arrtuwed Ci :Product Kat tturer, ;Gaff CoastSUPO..+&Ms not ctl.�r'qr L.LC- 4ti€r=ssFFfran=l 4BM Horseshoe 3eeck. FL 32-64a- {3523 I 648{3523 49B-781;7 rayCa3rsffcaaspty:com AjAhari�df greb-ma RW SSW--n; ra;st�s3 iE =a;rep�sar; fdresshe itai9 Qili'iu'-e'�S�*�L1ild":-t€E`:'xrt�'L'��.—^.''i3ti tog• i Canary F�u?nsta Subcattogary, Ketal:Runfli g. i ramp Fa ce INL--- E xx !nes a .Fp s a• �r � �.AFd3ltect! zsed Rani `Prax�ssxtl>raf Eaais�eer^ U svatrra.-dar..,Reprrrt I�!iarzdcnpy..Fzeei`recs: rfoT:isia r iza .;nr%§x i et r ;wi#sr aevef f: 'T anieG: n;. i svaivationReport ;fis tY3a Li ensue Q ftty-.— R.2}! 't..L..`Cerfi .S r:ItT£v ity.Qssnrestce�tnni pit3iis�rc Date aq!-Z�7_924 Widate&By ELacce.8aidem U `8��fan:,Cfeltlist-i iriicaPY:izi.:ri Clef Mir of ndependentma FL11651 R2 COI Cert of Ind Kuhn Eng.pdf FL11651 R2 COI Letter of Name change.odf I €L ie..�cia=..rl':Star4dard,-and:16 ar rof:standwdf}� TAS iffl . TAS 119 ZeIQ TAS M- 2023- UL 1997 2DG4 `€11.:5E8: �ffQ6 CerYisi:ed.8 f�s-:t�€bri "�a:�. fu';��P_dff :' �'I?�gs� ��r�efx'i✓k�g��w�I�s"TrlPpltiifYl�i� �EBt ;rg�°!�d°losr€ 1iS