HomeMy WebLinkAboutProduct Approval Florida Building Code Online r r r littps:/lflol7dabuilding or+=,Opr/pr app_Otl.aspx?parralxl-wGEVXQwtI3q.
RC l D"_'D Sg 2016
NP
Vm
. eMHome L99 In User Registration Hot Topks sltmt Swdtrge sta's&Facts Pdeca bns FSC staff HCS Std Map Oft search
Business f-, t
Professional P'°d°`t User ° 'IL
A ossa:pub:e User GO
PY
t,,� CrorklrcflF�n'LaIL•fenu>Pio1�o:nra:c2t�n�se�.r,'r,>�.�xn C�;>A9""r'ID1�t' +Q"Sa9
{, FL# FL389-R8
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer American Shutter Systems Association,Inc.
Address/Phone/Email 4268 Westroads Drive
West Palm Beach,FL 33407
(561)209-8263
bfeeley@easternmetal.com
Authorized Signature. Bill Feeley
frodriguez@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory Accordion
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Walter A..Tillit,)r.P.E.
Evaluation Report
Florida License PE-44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2017
Validated By John W.Knezevicit,PE
Validation Checklist-Hardcopy Received
Certificate of Independencei X89 RR9 COI HV ACyoRDZON CI_NQ_hHZ_pdF
Referenced Standard and Year(of Standard) Standard ear
ASTM E-1886 2005
ASTM E-1996 2005
ASTM E-330 2002
TAS 201,202,203 1994
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method i Option D
Date Submitted 04/29/2015
Date Validated 04/29/2015
Date Pending FBC Approval 05/07/2015
Date Approved 06/22/2015
1-oft 9/8/2015.1:19 Pl
Florida Building Code Online haps://floridnbuildingorgepr;pr_app_dtl.aspx?paran--wGEVXQwtDq,
c p
FL## =Madel Number or Name Description j
389.1 , .'Bertha HV Accordion Shutter-Blade 3- `Extruded aluminum interlocking blades retained by treats(top and '
(Non-HVHZ)-Dnvg 15-086 bottom)for storm protection
Limits of Use Installation Instructions
Approved for use In HVHZ:No rt389 R8 TI AA.S.S_3_iNC. DR4ci.15-42{_pdf !
t Approved for use outside HVHZ:Yes Verified By:American Test Lab of South Florida Inc
Impact Resistant:Yes ' Created by Independent Third Party:Yes
'r Design Pressure:N/A ;Evaluation Reports ±
Other:Large Missile Level"D".Max span is 12'-7"for 35 psf positive FL389 �.E R.S�S_A INC. P.E.r.DRY1-.1_086 df
i ASD load and 13'-0"for 35 psf negative ASD load the HV3 blade Wo Created by Independent Third Party:Yes
window blade,5'-2"for 110 psf ASD load for HV3 blade yr/o window
blade and 8'-11"for 62 psf,9'-6"for 55 psf HV3 blade w/window blade
working in unlson.Max.span for HV3 blade w/9 windmv blade for
Installations into Metal Stud walls is 79"for max.ASD pressure rating
of+72,-72 and 84"for+64,-64 psf.See sheet 5 for other spans and
ASD pressures.
'389.2 Bertha HV Accordion Shutter-Blade i Extruded aluminum interlocking blades retained by tracks(top and —?
Only-(Nan-HVHZ)-Dnvg 15-085 bottom)for storm protection
Limits of Use i Installation Instructions
Approved for use in HVHZ:No 8 R.8 II A.S..$_xA C. DR-Wr-19_0$55.pdf
Approved for use outside HVHZ:Yes Verified By:American Test Lab of South Florida Inc
j Impact Resistant:Yes Created by Independent Third Party:Yes j
i Design Pressure:N/A ;Evaluation Reports
j Other:Large missile level"D".Max.Span is W-0"for 30 psf Fi?SRB A IC P_E.R_DR,Y .2551 Of
!negative ASD load depending on centermates and locking rod Created by Independent Third Party:Yes
configuration for the HVI blade,8'-0"for+64,-72 p.s.f.load for HV
y blade for Keystone mountings 7'-0"for+75,-75 p.s.f.for metals stud t
mountings and 8'-0"for 110 p.s.f.for HVI and HV1A working In unison.
I See sheets 7,11 and 20 respectively of installation drawings for other
ispans and pressures.
389.3 — i `~ r Bertha HV Accordion Shutter-COMBO- Extruded aluminum Interlocking blades retained by tracks(top and
(Non-HVHZ)-Dnvg 15-084 µ^--- -- _bottom)for storm protection —
j Limits of Use ;Installation Instructions j
t Approved for use in HVHZ:No FL853 IIII A.S,S.A_ft1_ DRldG.15 08 F.Ddf !
Approved for use outside HVHZ:Yes Verified By:American Test Lab of South Florida Inc
I Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports i
j Other:Large missile.Max.16'-0"span at 30 p.s.f ASD load for Blade 1 FQ3_9 R3 AE A.S.S_A._11C�P,E,R_DR1"JG,15 fTBl;gc7f
and 18'-0"for Blade 2.See schedules on sheet 12,25 and 28 Created by Independent Third Party:Yes
I respectively
i9adri 'lPc`aM
Curtest ct Its:;X940 earth 44amoe Saet Ta3ehaseE R 3E399 phone:05087-1824
The State of Florida tan WEED empbyer.Comrrioht 2oD7-2013 State of Ronda.;:Pr:vary Statement::AccessMy Statement.:Refund Statrsrrar>S.
Under Florida tare,emal addresses are puM records.If you 0 not runt your e•marT address reaased In response to a p,bHc-records request,do not send edachmn"s mai to this erddy.Instead,
contact the office by phone or by tractional nrua IF you have any questions,please contact 850.497.1395.*Pursuard to Section 455.275(1),Florida Statutes,eRaUt2 October 1,2D12,@censees
licensed under Chapter 455,F.S.must provide the Department wCh an ema3 address if they have one.The emaris provided may be used for offioal communratton rr2h the 6mnsee,however emaa
addresses are pubbe record.If you do not wish to supply a personal address,p'iaase proyde the Department wfth an e=3 address viNch can be made avalat to to the pry To determine 8 you are a
rnansee newt-r Oupler 455,FS.,pian a c*ah jlire.
product Appmvaf Accepts,
M99EEED
2.of 2 9/9/9.al 5 1.19 P1