HomeMy WebLinkAboutBuilding Permit Application i
ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: Permit Number: ����� • �3n'i
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue,Fort Pierce FL 34982
Phone: (772)462-1553 Fax: (772)462-1578 Commercial !'Residential X
PERMIT APPLICATION FOR: Other
PROPOSED IMPROVEMENT LOCATION: �+
Address: 2929 N Old Dixie Hwy, Ft Pierce, FL 34946
Legal Description: TAYLOR S/D FROM NE COR TRACT A RUN S 25 04 46 E 80.34 FT TO POB, TH CONT S 25 04 46
E 84,29 FT,TH S 80 22 56 W 179 FT,TH N 24 50 06 W 85.59 FT,TH N 80 48 54 E 179 FT TO POB(0.35 AC)(OR 3349-501)
Property Tax ID#: 1428-701-0001-030-5 Lot No.
Site Plan Name: Block No.
Project Name: Tom Cope Garage Door
Setbacks Front Back: Right Side: Left Side:i
I
DETAILED DESCRIPTION OF WORK:
CtK 11
CONSTRUCTION INFORMATION:
Additional work to benertormed under this permit—c ec a t a appy:
0HVAC Gas Tank ❑Gas Piping _Shutters h Q Windows/Doors
Electric 0 Plumbing Sprinklers F]Generator Roof Roof pitch
Total Sq.Ft of Construction: 9x7 Garage Door S : Ft.of First Floor:
Cost of Construction:$ 940 Utilities:Sewer E]Septic Building Height:
OWNER/LESSEE; CONTRACTOR: ' E
Name_TOM 6'r Joe Name: Terrance DeVault
Address: 7-9'c'.19 4V Old D ' I P w` Company: Customer's Choice Garage Doors&Openers,Inc.
City: �;-t pie-rce ate: C� Address: 706 NW Buck Hendry Way
Zip Code: 3 Yg Lf-(, Fax: City: Stuart State:FL
Phone No. Zip Code: 34994 Fax:
E-Mail: Phone No. 772-675-1066
Fill in fee simple Title Holder on next page(if different E-Mail: drjett@live com
from the Owner listed above) State or County License: 9 z'`."
11
If value of construction is$2500 or more,a RECORDED Notice of Commencement Is required.
I
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: E
DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: _Not Applicable
Name: Name:
Address: Address:
City: State: City: State:
Zip: Phone: Zip: PI hone:
FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: Not Applicable
Name: Name:
Address: Address:
City: City
Zip: Phone: Zip: Phone:
I certify that no work or installation has commenced prior to the issuance of a permit.
St.Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules,bylaws or and covenants that may restrict or prohibit such
structure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit,I do hereby agree that I will,in all respects,perform the work
in accordance with the approved plans,the Florida Building Codes and St.Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review:room additions,
accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use
WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property.A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend to obtain financing,consult with lender or an attorney before
commencing work or recording our Notice of Commencement.
G s
Sig ture of Owner/Lesse¢/Contractor as Agent for Owner Signatur of Contractor/Lic se Holder
STATE OF FLORIDA / STATE OF FLORIDA
COUNTY OF Sc;lal JAIC_ COUNTY OF
i
The forgoing instrument was acknowledged before me The forgoing instrument was acknowledged before me
this (day of be,+ 20 & by this-Iti-day of5e ylFE.- ,20 (p by
Aeyj� 14-- Q r Dial v 1-i'
(Name of person acknowledging) (Name of person ackn wledging)
(Signature of Notary Public-State of Florida) (Signature of Notary Public-State of Florida)
Personally Known J OR Produced Identification Personally Known OR ProgUGsa,Iderbiaficati=
Type of Identification Produced .•`'�r..o". David Tim o—ne Type of Identification Produced` �.••f U QQ it 11
a �'.Conmission#FF164909 _.���. '�` oo�mLsslo es Ol,2016
Commission No. (���C7`t"sJr: . 56sj)ires:OCl'Ol,2018 Commission No 7�aI
F�•�•• PONDEDTHRU �'a, ,t,',�..•` 1STFLONDEDTHRU RIDAN TARXLLC
1ST FLORIDA NOTARY,LLC
Revised 07/15/2014
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE
COMPLETE
INITIALS
I
Property Identification
I
Site Address: 2929 OLD DIXIE HWY
Parcel ID: 1428-701-0001-030-5
Account#: 9548
Map ID: 14285
Use Type: 0100
Zoning. RS-4
City/County: Saint Lucie County
Ownership
Thomas D Cope
Sharon M Cope
2929 N Old Dixie HWY
Fort Pierce,FL 34946
Legal Description
TAYLOR SID FROM NE COR TRACT A RUN S 25 04 46 E 80.34 FT
TO POB,TH CONT S25 04 46 E 84.29 FT,TH S80 22 56 W 179 IT,
TH N 24 50 06 W 85.59 FT,TH N 80 48 54 E 179 FT TO POB(0.35
AC)(OR 3349-501)
Current Values
Just/Market Value: $79,300
Assessed Value: $75,222 I,
Exemptions: 550,000
Total Areas
Taxable Value: $25,222
Taxes for this parcel: SLC Tax Collector's Office 12 Finished/UnderAir(SF): 864
Download TRIM for this parcel:Download PDF 19 Gross Area(SF): 3,128
Land Size(acres): 0.35
Land Size I(SF): 15,088
This information is believed to be correct at this time but it is subject to change and is not warranted.
C Copyright 2016 Saint Lucie County Property Appraiser.All rights reserved.
I
I
I
II
�I
i
I
1 2 3 4 5 6 7 8
Door Width 9'-2"Shown NOTE: Track configuration above
the door opening does not affect
F See chart below for other the wind load rating of the door. F
Top Bracket door widths
DETAIL A(sheet 2 of 3) Flag Bracket
•• ••..... --•- Detall H(sheet 2 of 3)
0
1.
E C E
Door Height J Slide Lock or Lock Bars
T-0"Shown
Detail O(sheet 2 of 3)
4 Manual door locks are
See Chart required unless an automatic Jamb Bracket
below for other operator is installed. Detall F(sheet 2 of 3)
door heights 66"+!-3"
D ' 38P+/.3" t D
Bottom Bracket End Hinge L Strut A Strut Atlachment Intermediate Hinge 4"+/-3"
Detail C(sheet 2 of 3) Detail B(sheet 2 of 3) Detail E(sheet 2 of 3) Detail D(sheet 2 of 3)
1 •I
This product has been evaluated per ANSI/DASMA 108-05 for static air pressure. Jamb bracket quantities shown are for use with grade 2 or better southern
pine jambs.
This product has been evaluated per ANSI/DASMA 115-05 for large missile Impact and cyclic wind pressure.
Supporting structural elements are to be designed by a registered professional 'a' ST;S'fL•GF
Modal Number engineer for specific wind loads_ _
- - - PAN 02460 A R2460 SERIES - - - - - - - --- —•r 4n..A ------•'•:
PAN C24106 R24f0 SERIES PAN C24616 R2461 SERIES Door Total#Of Jamb Brkis NOTICE: .�,n,��!ORjDG;- `•:��
PANC24e0S R2460SERIES PAN 02471&172471 SERIES Haight SeeOone Total#of Sbuta rSlde eh�se drawings are a ��'/.`�OpJP.!-L:
8'-0° 4 4 4 supplement to the installation
PAN C24618 R2461 SERIES PAN 02472 a R2472 SERIES Instructions}fir a standard door
6 PANc24626R2A62sERIEs PANR2560SERIES _ 6'J" 4 4 4 and..only covers those
-- - PAN R2580 SERIES PAN R2561 SERIES PAN C2000 SERIES - - 6'-6" 4 - 4 4 -procedures that vary from - 9
PAN R2581 SERIES PAN R2571 SERIES PAN C2400 SERIES 6'-g° 4 4 4 standard door installation. If - --- -- -
these specific procedures are ` ,(
PAN 82582 SERIES PAN 82572 SERIES PAN C2500 SERIES T-0° 4 4 4 not followed, the door may not "�l'�C. `�
Door Width Des n Pressums End Stile Intermediate Stiles Intermediate Stiles Intermediate Stiles Impact T-0" 5 5 6 perform as designed. John E Scutes, A.
+ s -Ps /Hinges /Hinges 1HIn es Resistant T-8" 6 6 5 3121 Fairgate Drive
8'-2' 46.1 -52.0 Double 3H 311 311 NO 8'-0" 5 5 5 Florid.
P.E.Texas 75007
Florida P. $ 51737
0'-2" 41.1 -08.4 Double 3/1 311 3/1 YES Maximum section height is 21 in. Professional Engineer seal provided and, for
10'-2' 33.4 -37.7 Double 4/2 3/1 311 NO Maximum door height Is 16 ft. verification of wind load construction any,
12'-T 23.3 -26.3 Double 5/2 5/2 6/2 NO Doors taller than 8'-0" will be provided with commercial fullOESCBIPTIOC:
8'-2" 41.1 -08.4 Double 311 3/1 311 YES angle track having brackets and Jamb mounting spaced at r2'PAN 20DO SERIES"D LOAD
A This product is designed and sold by PSF. The AHJ or Engineer of Record Is responsible for determining the 24 Inches. +..��- SECTIONALDOGR
i
DESIGN PRESSURE 441.1/-04.4 PSP A
PSF required for any given site. IMPACT RESISTANT ',zOIUWDIIISO; YL-2000-01104144 SKEET;1 OF7 REV.
D►TE06k4/11/14 DRAWIM MVS
MODEL(S): See Sheet3
1 2 3 4 5 6 7 8
&hF
ND STILES 24e END HINGE 3
Go Galvanized Steel 14 Go Galvanized Steel TEK SCREW 24'
INTERMEDIATE STILE
P anufactured by Haas Door Co. TEK SCREW 1/4'X 3/4" Hex Washer Head 16 G° Galvanized Steel F
USH NUT 1/4' X 3/4" Hex Washer Head Self Drilling (3 per Bottom Bracket) Manufactured by Haas Door Co.
/16" Self Drilling (6 per Hinge) O BOTTOM BRACKEr
ee DETAILK for push nut o " 13 Go Galvanized Steel o®olacement. NOTE: This screw should LOW HEADROOM TOP INTERMEDIATE HINGE
ADJUSTABLE TOP FIXTURE be located below the prepunched BRACKET 18 or 14 Go Galvanized Steel
12 Ga ° hole and go through the hinge, PUSH NUT ° °end stile and skin edge.
TEK SCREW O O PUSH NUT SeeeDETAIL K for push nut TEK SCREW
1/4" X 3/4" Hex Washer Head 7/16-SH placement. 1/4"X 3/4" Hex Washer Head
Self Drilling (4 per Bracket) o o Sea DETAIL K for push nut Self Drilling (4 per Hinge)
E DETAIL A DETAIL B DETAIL C BOTTOM SEAL DETAIL D E
placement.
2 1/4" x 2 3/4" E STRUT
18 Go 50 KSI Minimum
Galvanized Steel
23e JAMB BRACKET p
I I 12 Ga Galvanized Steel 0 0 0
4 SLIDE LOCK or LOCK BARS I
I. (not required with operator) 31„
DO 2
D1Z o a TEK SCREW �� D
O 2—r, 1/4" X 3/4' Hex Washer
4 BOLT & NUT n n
TEK SCREW Head Self Drilling (4 per ��4 7
1/4"X 3/4"Hex Washer 1/4-20 X 5/B'Carriage Slide Lock)
Head Self Drilling (1 per Bolt & 1/4-20 Hex Washer DETAIL K ROLLER
DETAIL E End & intermediate Stiles) DETAIL F Nut (' per Jamb Bracket) DETAIL G There should be a space of
p 2" Diameter Nominal
1/4" between the roller hub Eleven Ball Nylon or
and the outside edge of the Ten Ball Steel with
NOTE: Details on some views omitted for clarity. roller holder which is set by a Minimum Workable
the push nut. Shaft Length Shown
C Double end stiles and end hardware may be
required on wider or heavier doors. >a�F fia �� a
CD 0 0 o m ti Sid .aeras
FLAG BRACKET
NOTE: Door must over hang side s Ja; ,ry
0
�O —
-- —— -- —---- --Jambs-a-m nlmum-of-1=„ on=each-- -- — - — - _ -- -,oTaTO
side to meet required wind load. BOLT -
a O 5/16 X 1 5/8" Log Bolt
."(=LORt�•
Mln, DOOR SKIN Min. (4 per Flog Bracket).
Of'I° - Minimal 25 Go Galvanized Pointed Steel -Qf-�°
BOLT & NUT
1/4-20 X 5/8"Track Bolt John E Scales, P.E.
& 1/4-20 Hex Washer Nut 3121 Fairgate Drive
(2 for Horizontal & 2 for Carrollton,Texas 75007
Vertical Track) Florida P.E. # 51737
VERTICAL TRACK Professional Engineer seat provided only for
BOLT & WASHER 2" Nominal 13 Go Galvanized Steel verification of wind load construction details.
WOOD JAMB DESCRIPTION:
5/16 X 1 5/8"Lag Bolt & 2" The vertical wood jamb fasteners may , 9'7"PAN 2000 SERIES WIND LOAD
O.D. x 7/16" I.D. Flat Washer be counter sunk to provide a flat SECTIONAL DOOR
A ';
NOTE: Jamb bracket must be in direct mounting surface. See Jamb p 9 9 DESIONPRESSl1RE+41dM6.051' A
contact with the 2x6 (No drywall allowed), attachment details onsheet 3 for DETAIL H IMPACTRESISTANT DeAwIRDH6tWL-1005-511041-16 EXEEhzDP3 UV.iambs CO the structure. tmryerms, DUEDRU:4111/14 10FAWlIff. efvS
mews�4rn:'�
MODEL(S): SeeShcet3
1 2 3 4 5 6 7 8
1 2 3 4 5 8 7 8
.. FASTENER TO CONTINUE
F PAST HEADER F
0
o
o
o E MODEL NUMBERS E
Lo
MODEL NUMBERS AVAILABLE OPENING
HEIGHT 2 X 6 GRADE 2 OR BETTER SOUTHERN
PAN C2000 SERIESPINE JAMBS.
° SEE CHART FOR WOOD JAMB ATTACHMENT
PAN C2400 SERIES TO STRUCTURE.
PAN C2500 SERIES
0
PAN C2410&R2410 SERIES MAXIMUM ON
D PAN C2460&R2460 SERIES CENTER SPACING D
PAN C2461&R2461 SERIES
PAN C2471&R2471 SERIES
FIRST FASTENER 4°to 10°
PAN C2472&R2472 SERIES ABOVE THE FLOOR OPENING
PAN C2480&R2480 SERIES WIDTH
PAN C2481&R2481 SERIES
PAN C2482&R2482 SERIES
PAN
SERIES
0 C PAN 82581SERIES Jemh Material FaslenerType Embed ma edtmnm gn�rd.,j.nCat�r eTlaw
�aa �� � � � XC
PAN 82571 SERIES Mim 2000 PSI Concreta Tapmn 1W W/1'OD washer 1.76' 2.50^ 4.00' ' 443 per Dade 12-0816-065'h37
PAN R2572 SERIES MN.3000PSICrroalo Tepwn1/4'w/1'OD-.her 1.76' 2.60' 4.00 ' 508 per Dade 12-0816-06
PANR2580SERIES MIa.4000PSIConcrete TepconlWw/1'ODwasher 1.75' 2.50' 4.00" ' 638 par Dade l2-0816-06Southern Phe 3/8'lag wll l/6'OD weeher 1.50' 1.50' 1.60' ' 620 per TDS-161e �'�• STATE OF
___PAN 82581 SERIES —SPmoaPlnnW—-318-Lgw/11/B'OD—h°r-—1:60'——1:50°-—fsD'— •.--—4e2—-perms-161e-- -- -r:L''Jn-,:p� C"•=� -— - -
PAN R2582 SERIES -- —- ,�4c�•nRiQ v'�;Or—- _= i -
NOTE:2X8==tsd to Ore wall must be Southam Pine Grade 2 or haver. !,%�%!O I �`��`,,�•
_ _.B B
John E Scates, P, .
3121 Fair Drive
Carrollton,Texas 75007
Florida P.E. # 51737
Professional Engineer seal provided only for
verification of wind load construction details.
DESCRIPTION:
A 9'r PAN 2000 SERIES WIND LOAD
SECriONALDOOR
B B DESIGN PRESSURE+41.1145,4 PSP A
IMPACT RESISTANT 'd 'DRAYMO804 IVL-2000-01104146 BHERt 3 OP 7 Rev.
IfaeNuyr 86II 01ah 4/11/Id avlvtl Bh MVS
mra�jpa.%any
MOOELISI: See Sheet
1 2 3 4 5 6 7 8
MkL Qiffl
o
Florida Departmentof SCIS Home Log In User Registration I Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff I 130S Site Maps finks -Search
Busines
ProdProfessi nal USER!PublicUser l
r^ �iI'
Regulation
Product Approval Menu>Product or Aoolication Search>Application List>Application Detail
• FL# FL16660-R4
Application Type Revision
Code Version 2014
Application Status Approved
i
Comments
Archived
i
Product Manufacturer Haas Door Company
Address/Phone/Email 320 Sycamore St.
Wauseon,OH 43567
(419)337-9900 Ext 243
mschweltzer@haasdoor.ctxn
Authorized Signature Mark Schweitzer
mschweitzer@haasdoor..com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Sectional Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
✓: Evaluation Report-Hardoopy Received
Florida Engineer or Architect Name who developed the John E.Scates
Evaluation Report
Florida License PE-51737
Quality Assurance Entity Architectural Testing,Inic,
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Kurt Dietrich PE
v'' Validation Checklist'-Hardcopy Received
Certificate of Independence FL16660 R4 COI Cert iof Ind Scates 2015 s.odf
i
i
Referenced Standard and Year(of Standard) Standard Year
ANSI/DASMA 108 2012
ANSI/DASMA 115 2005
Equivalence of Product Standards
Certified By
Sections from the Code
u '
Product Approval Method Method 1 Option D
Date Submitted 04/16/2015
Date Validated 04/25/2015
Date Pending FBC Approval 04/29/2015
Date Approved 06/22/2015
Date Revised 08/20/2015
Summary of Products
Go to Page i_ 0 0 0 Page 1/20 0
FL# Model,Number or Name Description
16660.1 01.HT 5000 Series HT Series sec onal Aluminum sandwich type garage door 9'2"
wide
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16660 R4 III WL-5000-0110-40-45 RevC s.odf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:+40.0/-45.0 Evaluation Reports
Other: FL16660 R41AE EvalReot r4s.odf
Created by Independent Third Party:Yes
i
16660.2 02.HT 5000 Series HT Series sectional Aluminum sandwich type garage door 16'2"
wide
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16660 R4 JI WL-5000-0194-31-35 RevC s.odf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:+31.3/-34.9 Evaluation Reports ,
Other: FL16660 R41AE EvalReot r4s.odf
Created by Iddependent Third Party:Yes
16660.3 03.HT 5000 Series HT Series sectional Aluminum sandwich type garage door 187"
wide
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16660 R4 PII WL-5000-0218-30-34 RevB s.odf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:+30.0/-33.9 Evaluation Reports
Other: FL16660 R411AE EvalReot r4s.odf
Created by Independent Third Party:Yes
16660.4 04.HT 600,700,2000,800,&900 HT Series sectional sandwich type garage door 9'2"wide
Series
Limits of Use Installation instructions
Approved for use in HVHZ:No FL16660 R41[II W1--0600-0110-25-281- RevC s.odf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+24.8/-28.0 Evaluation Reports
Other:Glazing is an available option for the 600,700,2000& FL16660 R4 AE EvalReot r4s.odf
800 Series product only but it does not meet the impact Created by Independent Third Party:Yes
resistant requirement for windbome debris regions.Glazing is
not an available option for the 900 Series product.
i
16660.5 05.HT 600,700,2000,800,&900 HT Series sectional sandwich type garage door 162"wide
Series 1'
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16660 R41;II WL-0600-0194-24-27L RevC s.odf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:No Created by Independent;Third Party:Yes
Design Pressure:+23.9/-26.7 Evaluation Reports
Other:Glazing is an available option for the 600,700,2000& FL16660 R4 AE EvalRept r4s.pdf
800 Series product only but it does not meet the impact Created by Independent Third Party:Yes
resistant requirement for windbome debris regions.Glazing is
not an available option for the 900 Series product.
16660.6 06.HT 600,700,2000,800,&900 HT Series sectional sandwich type garage door 18'2"wide
Series
Limits of Use Installation IInstructl ns
Approved for use in HVHZ:No FL16660 R41,II WL-0600-0218-24-27L RevD s.ridf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:No Created by Independent,Third Party:Yes
Design Pressure:+23.9/-26.7 Evaluation Reports "
Other:Glazing is an available option for the 600,700,2000& FL16660 R41 AE EvalReot r4s.pdf
I�
I
Ii I
800 Series product only but it does not meet the impact Created by Independent Third Party:Yes
resistant requirement for windborne debris regions.Glazing is
not an available option for the 900 Series product.
16660.7 07.HT 600,700,2000,800,&900 HT Series sectional sandwich type garage door 18'2"wide
Series
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16660 R41 II WL-0600-0218-30-34 RevB s.pdf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:+30.0/-33.9 Evaluation Reports
Other: FL16660 114�AE EvalRept r4s.pdf
Created by Independent Third Party:Yes
I
16660.8 08.PAN C2000,C2400,C2410, PAN Series sectional pan type garage door 9'2"wide
R2410,C2460,R2460,C2461, I'
R2461,C2471,R2471,C2472,
R2472,C2480,R2480,C2481,
R2481,C2482,R2482,C2500, I'
R2560,R2561,R2571,R2572,
R2580,112581,112582
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL16660 R41 II WL-2000-0110-25-281- RevC s.pdf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+24.8/-28.0 Evaluation Reports
Other:Glazing is an available option for all the Pan Series FL16660 R41'AE EvalRept r4s.pdf
product listed but it does not meet the impact resistant Created by Independent Third Party:Yes
requirement for windborne debris regions.
16660.9 09.PAN C2000,C2400,C2410, PAN Series sectional pan,type garage door 9'2"wide
R2410,C2460,R2460,C2461,
R2461,C2471,R2471,C2472,
R2472,C2480,R2480,C2481,
R2481,C2482,R2482,C2500,
R2560,R2561,R2571,R2572,
R2580,R2581,R2582 I�
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16660 R4I II WL-2000- 0110-35-39 RevB s.pdf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+35.0/-39.0 Evaluation Reports '
Other: FL16660 R4� AE EvalRept r4s.pdf
Created by IndependentThird Party:Yes
i.
16660.10 10.PAN C2000,C2400,C2410, PAN Series sectional pan type garage door 16'2"wide
R2410,C2460,R2460,C2461,
R2461,C2471,R2471,C2472,
R2472,C2480,R2480,C2481,
R2481,C2482,R2482,C2500,
R2560,R2561,R2571,R2572,
R2580,R2581,R2582
Limits of Use InstallationlInstructlons
Approved for use in HVHZ:No FL16660 114111 WL-2000-0194-24-27L RevC s.pdf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+23.9/-26.7 Evaluation Reports
Other:Glazing is an available option for all the Pan Series FL16660 Rd AE EvalRept r4s.pdf
product listed but it does not meet the impact resistant Created by Independent Third Party:Yes
requirement for windborne debris regions.
16660.11 11.PAN C2000,C2400,C2410, PAN Series sectional pan type garage door 16'2"wide
R2410,C2460,R2460,C2461,
R2461,C2471,R2471,C2472,
R2472,C2480,R2480,C2481,
R2481,C2482,R2482,C2500,
82560,R2561,R2571,R2572,
112580,112581,112582
Limits of Use Installation'Instructions
Approved for use in HVHZ:No FL16660 114'II WL-2000-0194-31-35 RevB s.pdf
Approved for use outside HVHZ:Yes Verified By:'!John E.Scates 51737
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:+31.3/-34.9 Evaluation Reports
Other: FL16660 R4. AE EvalRent r4s.pdf
Created by Independent Third Party:Yes
i
16660.12 12.PAN C2000,C2400,C2410, PAN Series sectional pan type garage door 18'2"wide
R2410,C2460,R2460,C2461,
i
R2461,C2471,R2471,C2472,
R2472,C2480,R2480,C2481,
112481,C2482,R2482,C2500,
R2560,R2561,R2571,R2572,
R2580,R2581,R2582
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL16660 R41 II WL-2000-0218-24-27L RevD s.odf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant,No Created by Independent Third Party:Yes
Design Pressure:+23.9/-26.7 Evaluation Reports
Other:Glazing is an available option for all the Pan Series FL16660 R4I AE EvalReot r4s.12df
product listed but it does not meet the impact resistant Created by Independent Third Party:Yes
requirement for windborne debris regions.
16660.13 13.HT 600,700,2000,800,&900 HT Series sectional sandwich type garage door 9'2"wide
Series i,
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL16660 R4 II WL-0600-0110-41-46 RevA s.odf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:Yes Created by IndependentThird Party:Yes
Design Pressure:+41.1/-46.4 Evaluation Reports
Other: FL16660 R4 AE EvalReot r4s.ndf
Created by Independent Third Party:Yes
16660.14 14.HT 600,700,2000,800,&900 HT Series seconal sandwich type garage door 9'2"wide
Series
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16660 R4 II WL-0600-0110-41-46L RevC s.pdf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:+41.1/-46.4 Evaluation Reports
Other:Glazing is an available option for the 600,700,2000& FL16660 R4I AE EvalReot r4s.pdf
800 Series product only.It does meet the impact resistant Created by Independent Third Party:Yes
requirement for windborne debris regions.Glazing Is not an
available option for the 900 Series product.
16660.15 15.HT 600,700,2000,800,&900 HT Series sectional sandwich type garage door 16'2"wide
Series
Limits of Use Installatioril Instructions
Approved for use In HVHZ:No FL16660 R4 II WL-0600-0194-31-35 RevA s.odf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:+31.3/-34.9 Evaluation Reports
Other: FL16660 R4'AE EvalReot r4s.odf
Created by Independent Third Party:Yes
16660.16 16.HT 600,700,2000,800,&900 HT Series sectional sandwich type garage door 167'wide
Series
Limits of Use Installation!;Instructions
Approved for use in HVHZ:No FL16660 R41 II WL-0600-0194-31-35L RevC s.odf
Approved for use outside HVHZ:Yes Verified By:John E.States 51737
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:+31.3/-34.9 Evaluation Reports
Other:Glazing is an available option for the 600,700,2000& FL16660 114!AE EvalRent r4s.odf
800 Series product only.It does meet the impact resistant Created by Independent Third Party:Yes
requirement for windborne debris regions.Glazing is not an
available option for the 900 Series product.
16660.17 17.PAN C2000,C2400,C2410, PAN Series sectional pan type garage door 9'2"wide
R2410,C2460,R2460,C2461,
R2461,C2471,R2471,C2472,
R2472,C2480,R2480,C2481,
R2481,C2482,R2482,C2500,
R2560,R2561,R2571,R2572,
R2580,112581,112582
Limits of Use Installation 1!
Approved for use in HVHZ:No FL16660 114 II WL-2000-0110-41-46 RevA s.odf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:+41.1/-46.4 Evaluation Reports
Other: FL16660 R4 AE EvalRept r4s.odf
Created by Independent Third Party:Yes
16660.18 18.PAN C2000,C2400,C2410, PAN Series sectional pan type garage door 16'2"wide
R2410,C2460,R2460,C2461,
R2461,C2471,R2471,C2472,
R2472,C2480,R2480,C2481,
R2481,C2482,R2482,C2500,
ii
f
R2560,R2561,R2571,R2572,
R2580,R2581,R2582
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16660 R4 II WL-2000-0194-37-42 RevA s.Ddf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:+37.4/-41.7 Evaluation Reports
Other: FL16660 R41 AE EvalReot r4s.0df
Created by Independent Third Party:Yes
16660.19 19.HT 600,700,2000,800,&900 HT Series sectional sandwich type garage door 97'wide
Series
Limits of Use Installation 131instructitins
Approved for use in HVHZ:No FL16660 R4 Ii WL-0600-0110-21-241- RevB s.Ddf
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+21.3/-24.1 Evaluation Reports
Other:Glazing is an available option for the 600,700,2000& FL16660 R41!AE EvalReot r4s.ndf
800 Series product only but it does not meet the impact Created by Independent Third Party:Yes
resistant requirement for windborne debris regions.Glazing is
not an available option for the 900 Series product.
i
16660.20 20.HT 600,700,2000,800,&900 HT Series sectional sandwich type garage door 167'wide
Series
Limits of Use Installationlinstructions
Approved for use in HVHZ:No FL16660 R411 WL-0600-0194-37-42 RevA s.0df
Approved for use outside HVHZ:Yes Verified By:John E.Scates 51737
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:+37.4/-41.7 Evaluation Reports
Other: FL16660 R41 AE EvaIR'eot r4s.Ddf
Created by Independent Third Party:Yes
Go to Page i 0 0 Page 1/20 0
Sack Next '
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850.487-1824
I
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Flodda.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your a-mail address released In response to apublic-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.'Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,
please click h.er .
Product Approval Accepts:
®® FRCi M
sccuritva i.-mucs
I �
I,
I �
i
I ul,
i
I li
i
I.