Loading...
HomeMy WebLinkAboutProduct Review Affidavit i I I l. i i9t Business Professional Regulation SCIS Home { Log In { User Registration j Hot Topic { Submit Surcharge Stats&Facts i Publications,{ FBC Staff { BCIS Site Map Links Search Florida '' 1 r Product Approval IUSER:Public User _Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL389-R8 Application Type a l I Code Version 20 Application Status Approved i Comments Archived [_1 I Product Manufacturer American Shutter Systems Associationl,Inc. Address/Phone/Email 4268"Westroads Drive West Palm Beach,FL 33407 (561)209-8263 bfeeley@easternmetal.com Authorized Signature Bill Feeley Irodriguez@easternmetal.com I Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Shutters Subcategory Accordion 'I I Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer j ID Evaluation Report-Hardcopy ReceI ived Florida Engineer or Architect Name who developed Walter A..Tillit,Jr.P.E. the Evaluation Report Florida License PE-44167 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2017 Validated By John W. Knezevich,PE i CD Validation Checklist-Hardcopy Received I Certificate of Independence FL389 R8 COI HV ACCORDION CI NONHVHZ.odf Referenced Standard and Year(of Standard) Standard Year ASTM E-1886 2005 ASTM E-1996 2005 ASTM E-330 2002 TAS 201,202,203 1994 Equivalence of Product Standards Certified By I; Sections from the Code I I 1 f i. I Product Approval Method Method 1 Option D Date Submitted 04/29/2015 Date Validated 04/29/2015 Date Pending FBC Approval 05/07/2015 Date Approved 06/22/2015 Summary of Products FL# Model,Number or Name Description 389.1 Bertha HV Accordion Shutter- Extruded aluminum interlocking blades retained by tracks Blade 3-(Non-HVHZ)-Drwg 15- (top and bottom),for storm protection 086 j Limits of Use Installation Instructions Approved for use in HVHZ:No FL389 R8 II A.S.S.A.INC. DRWG.'15-086.odf Approved for use outside HVHZ:Yes Verified By: American Test Lab of South Florida Inc. Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports j Other:Large Missile Level"D".Max span is 12'-7"for 35 psf FL389 R8 AE X-S.S,A.INC. P.E.R. DRWG.15-086.1)df positive ASD load and 13'-0"for 35 psf negative ASD load Created by Independent Third Party:Yes the HV3 blade w/o window blade,5'-2"for 110 psf ASD load for HV3 blade w/o window blade and W-11"for 62 psf,9'-6" for 55 psf HV3 blade w/window blade working in unison.Max.span for HV3 blade w/o window blade for installations into Metal Stud walls is 79"for max.ASD pressure rating of+72,-72 and 84"for+64,-64 psf. See sheet 5 for other spans and ASD pressures. .i 389.2 =1Only- V Accordion Shutter glad Extruded aluminum interlocking blades retained by tracks Non-HVHZ)-Drwg 15-08 (top and bottom)for storm protection Limits of Use installation Instructions; Approved for use in HVHZ:No FL389 R8 II A.S.S.A.INC'! DRWG.15-085.Ddf Approved foruse outside HVHZ:Yes Verified By: American Test!Lab of South Florida Inc. Impact Resistant:Yes Created by Independent Tli�d Party:Yes Design Pressure:N/A v ion eports I Other:Large missile level"D". Max.Span is 16'-0"for 30 FL389 R8 AE A,S.S.A.INC. P.E.R. DRWG. 15-085 HV.pdf p.s.f negative ASD load depending on centermates and Created by Independent THird Party:Yes locking rad configuration for the HV1 blade,W-0"for+64, -72 p.s.f. load for HV blade for Keystone mountings 7'-0"for +75, -75 p.s.f.for metals stud mountings and W-0"for 110 p.s.f.for HVI and HV1A working in unison.See sheets 7,11 and 20 respectively of installation drawings for other spans and pressures. i 389.3 Bertha HV Accordion Shutter- Extruded aluminum interlocking blades retained by tracks COMBO-(Non-HVHZ)-Drwg 15-084 (top and bottom)for storm-protection Limits of Use Installation Instructions! Approved for use in HVHZ:No FL389 R8 II A.S.S.A. INC': DRWG.15-084.pdf Approved for use outside HVHZ:Yes Verified By: American TestILab of South Florida Inc. Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Large missile. Max. 16'-0"span at 30 p.s.f ASD load FL389 R8 AE A.S.S.A.INC. P.E.R. DRWG.15-084.odf for Blade 1 and 18'-0"for Blade 2.See schedules on sheet Created by Independent THird Party:Yes 12,25 and 28 respectively .I i 'i Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement i Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you area licensee under Chapter 455,F.S.,please click here. I Product Approval Accepts: Credit Card Safe 1 I