HomeMy WebLinkAboutProduct Review Affidavit i
I
I
l.
i i9t
Business Professional Regulation
SCIS Home { Log In { User Registration j Hot Topic { Submit Surcharge Stats&Facts i Publications,{ FBC Staff { BCIS Site Map Links Search
Florida ''
1 r Product Approval
IUSER:Public User
_Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL389-R8
Application Type a l
I
Code Version 20
Application Status Approved
i
Comments
Archived [_1
I
Product Manufacturer American Shutter Systems Associationl,Inc.
Address/Phone/Email 4268"Westroads Drive
West Palm Beach,FL 33407
(561)209-8263
bfeeley@easternmetal.com
Authorized Signature Bill Feeley
Irodriguez@easternmetal.com
I
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory Accordion
'I
I
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer j
ID Evaluation Report-Hardcopy ReceI ived
Florida Engineer or Architect Name who developed Walter A..Tillit,Jr.P.E.
the Evaluation Report
Florida License PE-44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2017
Validated By John W. Knezevich,PE
i
CD Validation Checklist-Hardcopy Received
I
Certificate of Independence FL389 R8 COI HV ACCORDION CI NONHVHZ.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM E-1886 2005
ASTM E-1996 2005
ASTM E-330 2002
TAS 201,202,203 1994
Equivalence of Product Standards
Certified By
I;
Sections from the Code
I
I
1
f
i.
I
Product Approval Method Method 1 Option D
Date Submitted 04/29/2015
Date Validated 04/29/2015
Date Pending FBC Approval 05/07/2015
Date Approved 06/22/2015
Summary of Products
FL# Model,Number or Name Description
389.1 Bertha HV Accordion Shutter- Extruded aluminum interlocking blades retained by tracks
Blade 3-(Non-HVHZ)-Drwg 15- (top and bottom),for storm protection
086 j
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL389 R8 II A.S.S.A.INC. DRWG.'15-086.odf
Approved for use outside HVHZ:Yes Verified By: American Test Lab of South Florida Inc.
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports j
Other:Large Missile Level"D".Max span is 12'-7"for 35 psf FL389 R8 AE X-S.S,A.INC. P.E.R. DRWG.15-086.1)df
positive ASD load and 13'-0"for 35 psf negative ASD load Created by Independent Third Party:Yes
the HV3 blade w/o window blade,5'-2"for 110 psf ASD load
for HV3 blade w/o window blade and W-11"for 62 psf,9'-6"
for 55 psf HV3 blade w/window blade working in
unison.Max.span for HV3 blade w/o window blade for
installations into Metal Stud walls is 79"for max.ASD
pressure rating of+72,-72 and 84"for+64,-64 psf. See
sheet 5 for other spans and ASD pressures.
.i
389.2 =1Only-
V Accordion Shutter glad Extruded aluminum interlocking blades retained by tracks
Non-HVHZ)-Drwg 15-08 (top and bottom)for storm protection
Limits of Use installation Instructions;
Approved for use in HVHZ:No FL389 R8 II A.S.S.A.INC'! DRWG.15-085.Ddf
Approved foruse outside HVHZ:Yes Verified By: American Test!Lab of South Florida Inc.
Impact Resistant:Yes Created by Independent Tli�d Party:Yes
Design Pressure:N/A v ion eports I
Other:Large missile level"D". Max.Span is 16'-0"for 30 FL389 R8 AE A,S.S.A.INC. P.E.R. DRWG. 15-085 HV.pdf
p.s.f negative ASD load depending on centermates and Created by Independent THird Party:Yes
locking rad configuration for the HV1 blade,W-0"for+64,
-72 p.s.f. load for HV blade for Keystone mountings 7'-0"for
+75, -75 p.s.f.for metals stud mountings and W-0"for 110
p.s.f.for HVI and HV1A working in unison.See sheets 7,11
and 20 respectively of installation drawings for other spans
and pressures.
i
389.3 Bertha HV Accordion Shutter- Extruded aluminum interlocking blades retained by tracks
COMBO-(Non-HVHZ)-Drwg 15-084 (top and bottom)for storm-protection
Limits of Use Installation Instructions!
Approved for use in HVHZ:No FL389 R8 II A.S.S.A. INC': DRWG.15-084.pdf
Approved for use outside HVHZ:Yes Verified By: American TestILab of South Florida Inc.
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Large missile. Max. 16'-0"span at 30 p.s.f ASD load FL389 R8 AE A.S.S.A.INC. P.E.R. DRWG.15-084.odf
for Blade 1 and 18'-0"for Blade 2.See schedules on sheet Created by Independent THird Party:Yes
12,25 and 28 respectively
.I
i
'i
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
i
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The