Loading...
HomeMy WebLinkAboutProduct Approval Opening I Size (wx H) cn 1. FL17162.1 36 x 86 (Fixed) 2. FL17162.1 36 x 86 e LL 00 (Fixed) 3. FL14604.6 52 x62 g CT � ~ (Single Hung) g ($ n; X 4. FL17162.1 52 x26 $ (Fixed) . ~ 5. FL14604.6 37 x 57 (Single Hung) 6. FL14604.6 37 x 57 (Single Hung) W� v 7. FL14604.6 36 x56 `n (Single Hung) 1 2 8. FL17162.1 35 x 35 Liv Liv (Fixed) O 9. FL17162.1 76 x 38 (Fixed) ca en en c 10. FL17162.1 76 x38 v (Fixed) O u �3 PP Si!SStairs LLLJJJ � CL > r C Orn 10 N � M ® m ca J Foyer --I LL L U U ca L— .0 _N L it O in ti LL LO 7 Bed 3 SCALE: 8 NOT TO SCALE Bed 3 DAM 6 5 Sep 20,2016 Bed 2 Bed 1 PAGE DESCRIPTION: Site Plan _ _ PAGE: OF1 Jr F WINDOW&DOOR 1000 Clint Moore Dr.#109 P:561-988-2444 Boca Raton,FL 33487 F:561-826-9180 Lic.#:CRC1330842 SCC131151629 Property Information Building Information Owner: Barbara Bishop Wind Zone: 170 MPH. Address: 5730 Place Lake Drive Exposure Category: C Ft Pierce,FL 34951 Minimum Building Dimension: 44 ft. Mean Roof Height: 20 ft. JU Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 36 86 14 38.2 -41.6 2 Int 36 86 14 38.2 -41.6 3 Int 52 62 14 38.1 -41.5 4 Int 52 26 14 40.2 -43.6 5 Int 37 57 14 39.2 -42.6 6 Int 37 57 14 39.2 -42.6 7 Int 36 56 14 39.3 -42.7 8 Int 35 35 14 40.2 -43.6 9 Int 76 38 14 38.3 -41.7 10 Int 76 38 14 38.3 -41.7 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.51h Edition(2014)Florida Building Code. Page 1 of 1 WINDOW & DOOR OPENING INFORMATION — —— — A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE OPENING (Location) IS THIS A PRODUCT ROUGH ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS NUMBER or Interior OR DOOR TYPE NUMBER + PSF + PSF TESTED DIMENSIONS MULLION REQ YM ( ) (-)PSF ( ) (-)PSF SIZE REQ Y/N/NA 1 Int W 7/16"Lami FL17162.1 70 70 38.2 41.6 120x48 36x86 Y N 2 Int W 7/16"Lami FL17162.1 70 70 38.2 41.6 120x48 36x86 Y N 3 Int W 5/16°Lami FL14604.6 60 60 38.1 41.5 53X96 52x62 Y N 4 Int W 7/16°Lami FL17162.1 70 70 40.2 43.6 120x48 52x26 Y N 5 Int W 5/16"Lami FL14604.6 60 60 39.2 42.6 53X96 37x57 N N 6 Int W 5/16"Lami FL14604.6 60 60 39.2 42.6 53X96 37x57 N N 7 Int W 5/16°Lami FL14604.6 60 60 39.3 42.7 53X96 36x56 N N 8 Int W 7/16"Lami FL17162.1 70 70 40.2 43.6 120x48 3505 N N 9 Int W 7/16"Lami FL17162.1 70 70 38.3 41.7 120x48 76x38 Y N 10 Int W 7/16"Lami FL17162.1 70 70 38.3 41.7 120x48 7608 Y N 5/16/2016 Florida Building Coda Online e a i i s a ' . i 5- fto tuniuo T1as,3 Ol kn Horne tag in user MVIstratlon Hot Topics Submit Surcharge stats&Fads Publlcaft- # FEC Staff, efts Site Map Unks search �B}puns'#pnP^e`s` 'tgl P 1 V I Product Approval USER,Public User Regulation Product Aobtovai Menu>PC24lt or Aooit6ation Search> onliwkion list>ApplptSo Data « A FL# FLi7162-R� Application'type Revision Fl— -7 Kp 2 . Cade Version C9D Application Status *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Q Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft.Myers, FL 33912 (800)432-2204 Ext 4314 thoard@easternmetal.com Authorized Signature Timothy Hoard thoard@easternmetal.com Technical Representative Timothy).Hoard Address/Phone/Email 10030 Bavaria Road Fort Myers,FL 33913 (SOD)432-2204 Ext 4314 thoard@easternmetat.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Certification Mark or Usting Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) ftandard X-M AAMA/WDMA/CSA 101/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996 2009 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By n r 3 i httnsJ/www,floridWxhlding.org/pr/pr app ctrl.aspx?param=wGEVXQwtDgvCo3Ea IIBUi2%2bfT%2fkczkvalmgMKwc6S49yc%2bnziIIMA%3d%3d 112 5116=6 _ Florida Stiilding Code Online * } Product Approval Method Method 1 Option A Date Submitted 06/22/2015 Date Validated 09/14/2015 Date Pending FBC Approval Date Approved 09/17/2015 Summary of Products FL# Model,Number or Name Description 17162.1 Series 3000 Aluminum Impact fixed Series 3000 Aluminum Impact Fixed Window with PVB Window with PVB Interlayer interlayer Limits of Use CertMkation Agency Certificate Approved for use In HVH Yes E 2 T R2 C n N10 0 5:Ddf Approved for use outside Z.Yes FL17162 R2 C CAC NI012096.odf Impact Resistant:Yes QuaNty Assurance Contract Expiratlon Date Design Pressures+85.0/-9D.0 05/31/2018 Other.Maximum size of 120"x 48"at+70.0/-70.0 Installation Instructions Maximum size of 48"x 54"at+85.0/-90.0 EL17162. R2_II_08-02310A.odf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party:Yes Evaluation Reports EL17162 R2 AE 13-01 9,27-COMP,pdf EL17162 R2 AE 51 67A.12df FJ, n62 R2 AE NOA 13-0129:27 Du,Ro�t Py LM Created by Independent Third Party:Yes 17162.2 Series 3000 Aluminum Impact Fixed Series 3000 Aluminum Impact Fixed Window with Sentryglas Window with Sentryglas interlayer interlayer Limits of Use CertiAeation Agency Cettililcite Approved for use in HVHZ:Yes EL17162_R2 C CAC NI012994.01.odf Approved for use outside HVHZ:Yes FL17162,_R2__C CAC N1012094-R1.Ddf Impact Realstant.Yes Quality Assurance Contract Expiration Date Design Pressure.+100.0/-100.0 05/31/2018 Other Insulated Impact Glazing Type A: +95.0/-100,0 Installation Instructions Impact Only Glazing Type B: +100.0/-100.0 EL17162 R2 1I 08-02309A.12df Verified By: Luis R. Lomas,P.E.62514 Created by Independent Third.Party:Yes Evaluation Reports FL17162 R2 AE 13-0328.09-COMP.DdF X17162 R2 AE 513066A.20f FL17162 R2 AE NO lA 3-0328.09.ndf Created by Independent Third Party:Yes aeoh Next Contact ::1940 Horth Mon"Street,tbnahassee ft.32399 ¢one:sso-487-1824 The State of Florida Is an ANEW employer.Convri=20007-741 State of Florida. priyacv Slatement;:Actesslbllity Statement::Reftmd Statement Under Florida law,email addresses are public records.if you do not want your e•mall address released In response to a public-records request,do not send elechonic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487,1395.`Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public To determine If you are a licensee under Chapter 455,F.S.,please click JIM. Product Approval Accepts: Sf.{:t:Tlt'Att'71:2{:3' t i t i 1. httpsJtwww.f cridabuilding.orgtpr/pr app dU.aspx?param=wGEVXQwtDgvCo3Ee#llBUR%2bfT%2fkczkvalmgMKwc6S4gyca/o2bnzilIMA%3d%3d 2l2 a �■■• NOTICE OF PRODUCT CERTIFICATION x S`4! ' r CERTIFICATION NO: N1012095 "? DATE: 08/1912014 CERTIFICATION PROGRAM: Structural h =" COMPANY: Eastern CODE: 17834 r� To verify that the"Notice of Product Certification"is valid,please visit MM.NAMICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required ;to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Eastern Architectural Systems Series "3000" Aluminum Flange Frame 10030 Bavaria Road Fixed Window(Low Design Pressure) Ft.Myers,FL 33913 Configuration:O Glazing:Monolithic-3/16"Heat Strengthened Glass/0.090" DuPont PVB Interlayer/3/16"Heat Strengthened Glass or IG-3/16"Annealed Glass/Laminate-3/16°Heat Strengthened Glass/0.090"DuPont PVB Interlayer/3/16"Heat Strengthened Glass Frame: W-3048mm(120.00") H-1219mm(48.00") DLO: W-2984mm(117.50") H-1181mm(46.50") SPECIFICATION PRODUCT RATING AAMA/WDMA/CSA 101/I.S.2/A440-11 Class CW-PG70 3048 x 1219(120 x 48)-FW AAMA 506-11 Design Pressure:3351 Pa(70 psi) ASTM E1886-05/E1996-09 Negative Design Pressure:3351 Pa(70 psi) TAS 201/202/203-94 water Penetration Resistance Test Pressure:718 Pa(15.00 psi) Wind Zone 4 -Missile Level D Large Missile Impact Rated Product Tested By: Certified Testing Laboratories,Inc. Report No: CTLA 3010W-2/CTLA 301QW-2A CTLA 3010W-1/CTLA 301OW-1A Expiration Date: May 31,2018 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel: (804)684-5124/Fax: (804)684-5122 1 �■� NOTICE OF PRODUCT CERTIFICATION Ul` CERTIFICATION NO: NI012096 r , DATE: 08/19/2014 CERTIFICATION PROGRAM: Structural COMPANY: Eastern CODE: 1783-1 To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied.A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAM] if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Eastern Architectural Systems Series"3000" Aluminum Flange Frame 10030 Bavaria Road Fred Window-' Ft.Myers,FL 33913 Configuration:O Glazing:Monolithic-3/16"Heat Strengthened Glass/0.090" DuPont PVB Interlayer/3/16"Heat Strengthened Glass or IG-3/16"Annealed GlassftA- inate-3/16"Heat Strengthened Glass/0.090"DuPont PVB Interlayer/3/16"Heat Strengthened Glass' Frame: W-1219mm(48.00") 11-1372mm(54.00") DLO: W-1181mm(46.50") H4333mm(52.50") SPECIFICATION PRODUCT RATING AAMA(WDMA/CSA 101/I.S.2/A440-11 Class CW-PG851219 x 1372(48 x 54)-FW AAMA 506-11 Design Pressure:4069 Pa(85 psi) ASTM E1886-05/E1996-09 Negative Design Pressure:4309 Pa(90 pst) TAS 2011202/203-94 water Penetration Resistance Test Pressure:718 Pa(15.00 pst) Wind Zone 4-Missile Level D Large Missile Impact Rated Product Tested By: Certified Testing Laboratories,Inc. Report No: CTLA 3010W-3/CTLA 3010W-3A CTLA 3010W-1/CTLA 301OW-1A Expiration Date: May 31,2018 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway ' Hayes,VA 23072 Tel: (804)684-5124/Fax: (804) 684-5122 t L. Roberto Lomas P.E. 13-01.29.27-COM' P 233 W.Main St Danville,VA 24341 434-688-M9 illoni-as@ltlonmoe.com June 8,2015 Ref- N.O.A. 13-0129.27 Manufacturer. E.I.DuPont De Nem-ours&Co... Inc. DuPont P&JP Chestnut Run Plaza,712/1.61;P.O.Box 80712 Wilmington,DE 1,9880 Product: DuPont Buta.citeO PVB Interlayer To Whom It May Concerns This is to certify that I have reviewed all documentation.for_the enti0aw N A- r r my.review and to the,best of my Imowled e I found that the products in the RO.A.listed above) comp} with the-requvements of the Florida Building Code;; Edition{2014), Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributin in g the product(s)for which the reports are he g issued. Also, I don't have nor will acquire a financial interest.in any Other entity involved in the approval process of the listed product(s). Sincerely, A E N .0 TAT.T "A ! r . i '!-rti V NAL 'N /-,,I J I I'l-ON Luis R. Lomas P.E. FL No.: 62514 1 of I } 1 , L. Roberto Lomas P.E. Engineering Evaluation Report 233 W.Main St Danville,VA 24541, Report No.: 513067A 434688-0609 rilomas@lrlomaspe.com Manufacturer: Eastern Architectural Systems 16341 Domestic Ave. Ft.Myers, FL 33912 Product Line: Series 3000 Aluminum Flange Frame Impact Fixed Window—HVHZ-PVB Compliance. The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(aj.The product listed herein complies with requirements of the Florida Building Code. Supporting Technical Documentation: 1. Approval document:drawing number 08-02310 Revision A,prepared,signed and sealed by Luis Roberto Lomas P.E. 2. Test report No.:CTLA 301OW-2&-3 signed and sealed by Ramesh Patel P.E. Certified Testing Laboratories,Orlando,FL TAS 201-94 Large Missile Impact Test,Level D,Wind Zone 4 TAS 202-94 Uniform Static Air Pressure,00.0psf design pressure,I5.0psf water penetration(120"x48") +85.0/-90.Opsf design pressure, I6.0psf water penetration(48"x54") TAS 203-94 Cyclic Pressure loading t70.Opsf(120"x48") +85.01-90.Opsf(48"x54") 3. Report No.:CTLA 301OW-2A&-3A signed and sealed by Ramesh Patel P.E. Certified Testing Laboratories,Orlando,FL AAMA/WDMA/CSA 10111.S.2/A440-11 Design pressure: t70.Opsf(120"x48") +85.01-90.0psf(48"x54") Water penetration resistance /5.Opsf ASTM E1886-05 and ASTM E1996-09 ASTM E1886/E1996 Large Missile Impact,Level D,Wind Zone 4 ASTM E1886/E1996 Cyclic Load Test,t70.Opsf(120"x48") +85.0/-90.0psf(48"x54") 4. Anchor calculations,report number 513067-1,prepared,signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: Maximum design pressure: i7O.Opsf(120"x48") +85.0/-90.Opsf(48"x54") • Maximum unit size: 120"x 48"and 48"x 54" • Units must be glazed per ASTM El 300-04,see installation instructions for glass details. • This product is rated to be used in the HVHZ. • This product is impact resistant and does not require impact protection in wind bome debris regions. • Frame material to be aluminum. Installation: Units must be installed in accordance with approval document,08-02310 Revision A. Certification of independence: Please note that I don't have nor will acquire a 1�1111l.!!L! financial interest in any company manufacturing or distributing the product(s)for which ��� this report is being Issued.Also,I don't have nor will acquire a financial interest in any yt� 5 ', �lr other entity involved in the approval process of the listed product(s). NN;,Z,•\0 E TAT OF OR !�11111 1 of 1 Luis R.Lomas,P.E. FL No.:62514 06/22/2015 MIAMI, ADE MIANH DADECaUM PRODUCT CONTROL SECTION 11805 SIN 26 Street,Room 20$ DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2390 F(796)315-2599 NOTICE OF ACCEPTANCE tNOA) www miamidade.aov/eevnomv EX DuPont De Nemours&Co.,Inc. DuPont P&IP Chestnut Run Plaza,712/161,P.O.Box 80712 Wilmington,DE 19880 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami--Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOAH shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (in Miami Dade County)and/or the AHI(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. V this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within;their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with tate Florida Building Code,including the High Velocity Hurricane Zone. DESCRIPTION:DuPont ButaciteO PVB Interlayer APPROVAL DOCUMENT:Drawing No. 13-0129.27,titled"DuPont Butacite®PVB Interlayer",Sheet 1 and 2 oft,dated 01/15/2013,prepared by i✓.1.DuPont Do Nemours&Co.,Inc,signed and sealed by Allan A.Kozich,P.E., bearing the Miami-Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:None LABELING:Laminated lites under this Product Approval shall be permanently marked in a corner of the glass with:"MDCA-Butacite*PVB';standing for'?vfiami-Dade County Approved-Butacite@ PVB",and the laminator's identification mark. These marks shall be applied by the individual laminator producing the finished laminated glass product containing the Butacite®PVB interlayer. RE,NE,WAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,andlor manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building,Official. T19s NOA revises NOA#11-111&03 and consists of this page 1 and evidence page E-1,as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M.Utrera,P.E. NOA No.13-0129.27 terra- ac uM f Expiration Date:December 11,2016 } _ Approval Date:April 11,2013 0 Page I E.I.DuPont De Wetngurs&Co.:Inc, NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No.13-0129.27,titled"DuPont Butacitee PVB Interlayer'; Sheet 1 and 2 of 2,dated 01/15/2013,prepared by E.1.DuPont De Nemours,&Co.,Inc,signed and sealed by Allan A.Kozich,P.E. B. TESTS "Submitted ander NOA #11-0624.01" Test report Standard Date Sip-nature 1. A2280.01-10-18 ASTM D1929 03/29/11 Joseph A.Reed,P.E. 2. A2280.01-10-18 ASTM D 635 03/29/11 Joseph A.Reed,F.E. 3, A2280.01-10-18 ASTM D 2843 03/29/11 Joseph A.Reed,P.E. 4. A2280.01-10-18 ASTM G 155 03/29/11 Joseph A.Reed,P.E. 5. A2280.01-10-18 ASTM G 158 03129/11 Joseph A.Reed,P.E. C. CALCULATIONS 1. None, D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources(RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS "Srrbfnitted tinder NOA #11-1118.03" 1. Statement letter of code conformance to 2010 FBC issued by Allan A. Kozich & Associates,dated 03/01/2012,signed and sealed by Allan A. Kozich,P.E. "Submitted under NOA#11-0624.01" 2. Statement letter of co49,,ponformance to 2007 FBC and no financial interest issued by Allan A. Kozich &."Associates, dated 08/09/2011, signed and sealed by Allan A. Kozich,P.E. 113 Carlos M.Utrers,F.E. Product Control Examiner NOA No.13-0129.27 Expiration Date:December 11,2016 Approval Date:April 11,2013 f E-i 3 , DUPONT BUTACITE0 PVB INTERLAYER i EBQQUCT OESCRIPTIO-N MANUFACTURED BY: E.I.DUPONT DE NEMOURS&CO.,INC. A PLASTIC INTERLAYER MATERIAL FOR LAMINATION WITH GLASS ON BOTH SIDES. A TYPICAL GLAZING 18•MADE OF THE FOLL. OWING COMPONENTS: f A B C A - 118" 3.0 mm Annealed Glass ' 9ECTl B - 0.030° 0.76 mm DuPont ButedteO PVB Interla r C - 1/80 3.0 mm Annealed Glass MATERIAL CHARACTERISTICS ButackeS PVB Interlayer (Clear) Desi Wetton Test prop!!203 ButaciteO PV13 intens . Clear Self Ignition itmpemwe ASTM D1929 788'F 420 L^ Flash-IgnItimje ratWre ASTM D1929 788 OF 420•C Aw Smoke Diensity-Wt—Ing Density—Wt—IASTM D2843 7.2 . ' Burning Rate ASTM D635 0 mmfndm Xenon Weethering(4540 hrs) ASTM C168-02 `Weathering Flwwrel Strength Method A ASTM C13S-02 Method A Before I Atter 2940 psi 1- -.3189pi •WRATEIERING PER SECTION 2612 OF TIE FLORIDA BUILDING CODE THIS IS A COMPONENT APPROVAL AND DOES NOT INCLUDE AN EVALUATION OF STRUCTURAL PERFORMA NOE OF THIS COMPONENT. SYSTEMS INCORPORATMIG THIS COMPONENT SHALL APPLY FOR A PRODUCT APPROVA!. TO THIS OFFICE AND SHALL SUBMIT TEST REPORTS AND OTHER REQUIRED DOCUMENTS SHOWING THAT THE SYSTEM USING THIS COMPONENT WILL RESIST THE LOAD$ACCORDING TO CHAPTER Is OF THE FLORIDA BUILDING CODE. VB laterla,ver:,, BdMka Ce&- !. .1,t .E:I..duPont-de Nemotsni&Co.,Inc. . gm, ��� � � � pO PnlP&)P,-G><.• ?4 Chestnut Run Plaza Bldg 7121161 ��1E"aF•• S►'• �' �'.O. Box 80712 No iiBoe4 s > Wilmington DE 19880-0712 _= Phone: 302-999-2125 Ray.File#13•012U1 Sheet 1of 2 $TATE OF Drawing Date: 01/15/13 �i3O,�•••A- ,01�•'�2� 04- 03 2013 Allan A. Kozich, PE ••.0 A..••'�d�+` CA No. 1165 Registration# 16864 9 i DUPONT BUTACITEt. PVB INTERLAYER Material Characteristics Butacite@ PVB Interlayer (Colors) Designation Test es Self IgniflorILem ereture a ASTM 01928 788'F 420'C SON i rdtlorl T tore ASTM 01829 788' 420 Satf Ignition Temperature 3 ASTM D1929 788 7 W20'C• $elf I n$tion Temperature 141 ASTM 01929 188F 420 G) Self i nitir n Tram store J1 ASTM D1929 788 7 420 r Flash n38on 1'em nature 1 I ASTM A1929 788 7 E20 r,) Rash.i riitian Tempenatrrre t2J - ASTM D1928 770'1: 4101✓ Flash Igniffm Tempenature 3 ASTM D1929 770 IF 410 t Flash nitlost lekerature-fAl ASTM D1929 7887(420'C) f lash i nition Tern ratture OtASTM DIM 78871120 Av Smote g 1I ASTM 02843 7.2 . Avg Smoke Riung 121ASTM D2843 9.1 Av 8moke C} i taO ASTM D2843 10,2 Av &rioke'Densit Ratan 4 ASTM D2843. 90.1" Amg Smoke Dan sit R$8rlg[ ASTM D2843 8.1 Burning 8019,01 ASTM D836 0 mm/min. Burnt Rete[91 ASTM D635 0 rnmfinin. Bu Rats t4l ASTM D635 0 mmIr-Wn. Burn Rate 4 ASTM D635 0 r-ardin. BuRate S ASTM D635 0 mnvnrdn. [1]Gear Butedle®PVB interi�ayer swftocia bMianlda 121 Charcoal Grey Butadte®PVB Interlayer -AoD'N' "Tl0' `d •�7 (31 Blue-Green ButackeV PVB Interlayer 141 Azure Blue Bt acksO PV8 interlayer ���• 15)Solar Bronze Butadte®PVB Interlayer THIS IS A COMPONENT APPROVAL AND DOES NOT INCLUDE AN EVALUATION OF STRUCTURAL PERFORMANCE OF THIS COMPONENT. SYSTEMS INCORPORATING THIS COMPONENT SHALL APPLY FOR A PRODUCT APPROVAL TO THIS opme:AND SHALL SUSMrT TEST REPORTS AND OTHER REQUIRED DOCUMENTS sHOwme THAT THE SYSTEM USING THIS COMPONENT VOLL RESIST THE LOADS ACCOR13 NO TO CHANTER 16 OF TNS FLORIDA BUILDING CODE. iuobirr �'CuPOnt BUtacitsO PV8 lnter�eye'r' 4 ��iti� • K h��, E.I.duPont de Nemours &Co., Inc. �� DuPont KIP GLS ��,ti'� RB `• '� Chestnut Run Plaza Bldg 712/161 P. O.Box 80712 �• t Wilmington DE 19880-0712 -• Phone: 302-998.2125 STATSkV, file#13-012UT Sheet 2of2 ♦ �~ Drawing Date; 0.1115113 r �'• �+ . . �► �► D 4- to 3If-613 Allan A. Koz{ch, PE E flu 0. l'7 G+5 Registration#16864 �ttiiilE F r F REVISIONS REV DESCRIPTION DATE APPROWD A REVISED INSTALLATION DETAILS 08/22/15 R. NOCRE-11RIMENTS 15. FOR.ANCHORING FRAME INTO MASONRY/CONCRETE USE 1/4' TAPCONS WITH SUFFICIENT 1. E PRODT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION 2. WOOD FRAMI AND MASONRY OPENING BE DESIGNED AND ANCHORED TO PROPERLY DETAILS. TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE 16. FOR ANCHORING FRAME INTO METAL STRUCTURE USE 1/4" SMS OR SELF DRILLING SCREWS RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1% BUCK OVER MASONRY/CONCRETE IS OPTIONAL. WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2' WINDOW UNITS MUST BE 17. ALL FASTENERS TO BE CORROSION RESISTANT. ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED 18.INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE I (OR GREATER). MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. D. METAL STRUCTURE: STEEL 18GA, 33KST OR ALUMINUM 6063—T5 1/8` THICK MINIMUM 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED 19.WINDOW MAY BE INSTALLED HORIZONTALLY OR VERTICALLY COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF 20.GEOMETRICSHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS THE ARCHITECT OR ENGINEER OF RECORD. SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS IN SHEET 2. GEOMETRIC SHAPES ARE NOT LIMITED TO SHAPES SHOWN HEREIN. PROVIDED. B. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED ALUMINUM 6063—T6. 12.UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 2 FOR GLASS DETAILS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT R QUIREQ FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING FRAME INTO WOOD FRAMING OR 2X BUCK USE #14 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 7/16' MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED.,0623/2015 _ r Eastern. IE. . 'N`b. TABLE OF CONTENTS SERIES 3000 ALUMINUM FLANGE FRAMES 6' SHEET N0. DESCRIPTION IMPACT FIXED WINNDDO S- HVHZ .� tV`• 1 NOTES DRAM:2 ELEVATION AND GLAZING DETAILS JJLEE vAc 08- E310 A 3 - 4 INSTALLATION DETAILS NTS 07 24/14 1 OF 4 AllL V. =MAXFIRAMEocscmanor+ areA REVISED INSTALLATION DETAILS 06/22/15 R.L. AX 48" MAX FRAME WIDTH 6" MAX 6" M 6" MAX 2 ( O.C. 6` MAX 6' MAX / ll 8" M 12' MAX � O.C. / �\ 48 46 1/2" \ MAX FRAME HEIGHT D. 0. 54" 52 1/2" MAX MAX / HE GHT / D.L.O. l 10 \\ I 6" MAX _ MAX O.C. B" 6" NAX —!—! MAX I 6' MAX O.C. 4" MAX Imo—4" MAX 4" MAX 46 1/2" MAX D.L.O. A" MAX 117 1/2" D.L.O. DESIGN PRESSURE RATING IMPACT RATING DESIGN PRESSURE RATING IMPACT RATING f70.OPSF RGE MISSILE1MPACT +85.01-90.OPSF [AR GE MISSILEIMPACT MISSILE LEVEL D,WIND ZONE 4 AND NVHZ MISSILE LEVEL D,HIND ZONE AND HVlff SERIES 3000 PW FIXED WINDOW EXTEROR VIEW 1 1/32' 7/16 3/16` Hs 3/16 Hs SIGNED.06/23/2015 3/16" ANN .090 PVB BY DUPONT .090 PVB BY DUP T rrm a+.aw,:enaue e,no EXTERIOR EXTERIOR wii e'+wtir ..... `� 11L 3/16" HS 7/16' LAM] 3/16- HS 'IS a -1 1/32" LAMI INTERIOR GLAZING INTERIOR1!GLAZINGNPACERE { SIKAFLEX ERIES 3000 ALUMINUM FLANGE FRAMEr�-*•. 0IMPACT FIXED WINDOW — HVHZ — PVBSIKAFLEX 4" SITE 552 ELEVATIONS AND GLAZING DETAILS � ,3/4" 917E 552p,v !GLAZING DETAIL A GLAZING DETAIL 8 TS WE 07/24 14 08-023105N�T20F 4 A M 5/8" MIN. REVISIONS EDGE DISTANCE 1" MIN REV DFS[PoP110>+ DATE A° D WOOD FRAMING METAL EDGE DISTANCE f I A REVISED INSTALLMON DETAILS 06/22/15 R.L. OR 2X BUCK 1 7/16" MIN STRUCTURE BY OTHERS EMBEDMENT BY OTHERS 1/4' MAX. I_ r SHIM SPACE —1/4' MAX. 1" MIN. APPROVED 1/4" MAX. APPROVED SHIM SPACE EDGE DISTANCE INTERIOR SEALANT SHIM SPACE. SEALANT BEHIND FLANGE BEHIND FLANGE �- 1 4' SMS OR 1/4" SMS OR #14 WOOD SELF DRILLING SELF DRILLING SCREW SCREW SCREWS METAL STRUCTURE BY OTHERS EXTERIOR APPROVED SEALANT BEHIND FLANGE IV INTERIOR EXTERIOR INTERIOR JAMB.INSTALLATION DETAIL METAL STRUCTURE INSTALLATION EXTERIOR 1 7/16" MIN. 1/4" MAX. EMBEDMENT r SHIM SPACE EDGE DISTANCE INTERIOR #14 WOOD 1/4- SMS SELF DRILLING SCREW SCREW #14 WOOD APPROVED APPROVED SCREW SEALANTSEALANT 1/4" MAX q BEHIND FLANGE BEHIND FLANGE 1/ " MAX. WOOD FRAMING EXTERIOR SHIM SPACE _�SHIM SPACE OR 2X BUCK BY OTHERS APPROVED SEALANT WOOD FRAMING METAL BEHIND FLANGE OR 2X BUCK 1 7/16' MIN STRUCTURE BY OTHERS EMBEDMENT BY OTHERS JAMB INSTALLATION DETAIL. 1' MIN WOOD FRAMING OR2XBUCKINSTALLATI0N 5/8" MIN. a EDGE DISTANCE SIGNED:06/23/2015 EDGE DISTANCE VERTICAL CROSS SECTION um�.wmenraer..nu sn METAL STRUCTURE � � � \\\1llNfIJ/r. VERTICAL CROSS SECTION rSERIES EsSBrn � Ls 'i= WOOD FRAMING OR2XBUCKINSTALLA7TONEAI 3000 ALUMINUM FLANGE FRAME *•OAT #�' NOTES: PACT FIXED WINDOW - HVHZ - PVB 1.INTERIORANOEXTERIOR FINISHES.BYOTHERS, FLANGE INSTALLATION DETAILS i ce` NOTSHOWNFORCLARITY. 2.PERIMETER AND JOINT SEALANT BY07HERSTOBE V.vONO, �DESIGNEDINACCORDANCEWITHAS7ME2f12 �� OS- 10 A 7i'll"07/24/14 3 OF 4 Itifill 2 1/2" MIN. REVISMM EDGE DISTANCE REV oEsemolww w1E AWRGVM CONCRETE/MASONRY ARENSED IN5iAUATION DEfNLS 06/22/15 R.L. BY OTHERS e • ' e• e • 1 1/4" MIN. OPTIONAL IX BUCK • •e. e. ' EMBEDMENT SEE NOTES 3-7 SHEET 1 • EMBEDMENT { CONCRETE/MASONRY 1/4" MAX. BY OTHERS ... APPROVED SHIM SPACE 1/e" MAX. SEALANT OPTIONAL 1X BUCK a SHIM SPACE BEHIND FLANGE SEE NOTES 3-7 SHEET 1 �. ' 1/4" TAPCON 1/4" TAPCON INTERIOR AIL �.a 2 1/2" , EXTERIOR INTERIOR MIN. EDGE .. DISTANCE a EXTERIOR APPROVED SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL 1/4' TAPCON CONCRETEWSONRYINSTALLAWN APPROVED SEALANT BEHIND FLANGE OPTIONAL 1X BUCK HIM MAX. SEE NOTES 3-7 SHEET 1 SHIM SPACE NOTES: 1.INTERIORAND EXTERIOR FINISHES,BYOTNERS, T I PERIMETER OTSHOWN FAND�AOI SEALANTSYOTHERS TOBE CONCRETE/MASONRY _� DESIGNED INACCORDANCE WMI ASTM E2112 BY OTHERS 4 SIGNED:M3/2015 a+ 1 1/4" MIN. lllll e• •• e ' < EMBEDMENT M ..._ Sam I Ym�.. \,````R .. � • •• .• �_:jy:�.�r".«u��.«v.n,:�•u.�a�tru+ nd�iaivn VERTICAL CROSS SECTION SERIES 3000 ALUMINUM FLANGE FRAME w� p CONCRETFJMASONRYINSTALLATK3N IMPACT FIXED WINDOW - HVHZ - PVB FLANGE INSTALLATION DETAILS � . oRAwn: IM ND. REv i 4 iOR SCN EMrE 14 OB-0231 D A NTS 0724 4 OF 4 O 2016 Florida Building Code Online p. i a 1r. d Bas Home I Login I user Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publicntio s FOC Stell eardr I Usines I Product Approval ProfessiWUOR.Public User Regulation grt Aoorovai Menu>Product or Aodlratlon Search>Aodication List>Appkation Detep FL34604-R4 F L( ,�. �#.�c Application Type Rev son Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived tri Product Manufacturer CFt. rn Architectural Systems Address/Phone/Email Domestic Ave. yers,FL 33912 432-2204 Ext 4314d:@easternmetal.com Authorized Signature Timothy Hoard thoard@eastemmetal.com Technical Representative Timothy J. Hoard Address/Phone/Email 10030 Bavaria Road Fort Myers, FL 33913 I (800)432-2204 Ext 4314 E thoard@easternmetal.com ill ' Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute } Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) SAandard Year AAMA 506 2006 AAMA 506 2008 AAMA/WDMA/CSA 101/I.S.2/A440 2005 ANSI/AAMA/NWWDA 101/I.S.2 1997 ASTM E1886 2002 ASTM E1886 2005 ASTM E1996 2005 ASTM E1996 2002 ASTM E1996 2006 TAS 201 1994 TAS 202 1994 TAS 203 1994 i Equivalence of Product Standards } httpsJM rww.floridabL ildirig.orgW/pr app c 1.aspx?param=wGEVXowtDgsw8ZVNfeBA7ba&84AYj7ta/`2t*Etd6yLZmllQcT5Ve9Rdw%3d%3d 1/3 5/9 2096 Florida Building Code Ordine Certified By Product Approval Method Method 1 Option A Date Submitted 04/2212016 Date Validated 05/12/2016 Date Pending FBC Approval Date Approved 05/15/2016 Surrimary of Products Fl.# Model,Number or Name Description 14604.1 Series 1000 Non-Impact Aluminum Series 1000 Non-Impact Aluminum SH SH Umlti of Use Certification Agency Certificate Approved for use In HVHZ:No FL14604 R4 C CAC N11006177&IR4-sloned-od Approved for use outside HVHZ:Yes EL146W R4 !C CAC N100617702-112--sloned.od Impact Resistant:No Quality Assurance Contract Expiration i Design Pressure: +45/-45 06/30/2020 Other. Installation Instructions EL14604 R4 11 08=02477,od Verified By: Luis R. Lomas,P.E. 62514 Created by Independent Third;Party: Yes Evaluation Reports FL14604 R4 AE 513233.pd Created by Independent Third,:Party: Yes 14604.2 Series 1431 Non-Impact Vinyl SH Series 1431 Non-Impact Vinyl SH Nailing Fin Nailing Fin Umfts of Use Certl0cation Agency Certifleite Approved for use In HVHZ:No FL! D4 R4 I d.odf Approved for Use outskile HVHZ.Yes Quality Assurance contract Ekipfration Date Impact Resistant:No 12/31/2019 Design Pressure:+50/-50 Installation Instructions Other.Configuration:O/X Vent Size: W-44.38"H-35" 8L14604 R4 11 0 Ei±-00SSfiB,SWf Glazing: 3/4"Overall I.G. Verified By: Luis R. Lomas,P.E. Florida P.E.62514 Created by Independent Third,Party:Yes Evaluation Reports F 60 R4 AE 510945.2df Created by Independent Third,Party: Yes 146043 Series 1441 Non-Impact Vinyl SH Series 1441 Non-Impact Vlnyl�SH Range Flange Limits of Use Certification Agency Certlifficalle Approved for use In HVHZ:No FLI4604 R4 C CAC Approved for use outside HVHZ:Yes Quality Assurance Contract t, xplra p1ra p1ra p1m on Date Impact Resistant:No 04/30/2020 Design Pressure:+50/-50 Installation Instructions Other.Configuration: O/X Vent Size: W-50.38"H-35.13" Fi"Wfj04 R4 II 0Q558B.odf Glazing: 3/4"Overall I.G. Verified By: Luis R. Lomas, P.E. Florida P.E.61514 Created by Independent Third Party: Yes Evaluation Reports 8,14604 R4 AE 510S Created by Independent Third Party: Yes 14604.4 Series 2451 Impact Vinyl SH Nailing Series 2451 Impact Vinyl SH Nailing Fin Fin umilts of Use Certification Agency CertificateApproved for use In HVHZ:No E314604 R4 C CAC NIO1253 I 3-Rj=sioned�o. df Approved for use outside HVHZ.,Yes Quality Assurance Contract Expiration Date Impact Resistant,Yes 02/28/2017 Design Pressure:+50/-50 Installation Instructions Other.Configuration: O/X Max. Frame Size: W-48"H-72" EL14604_R4 11 08-0562B.odf Max.Vent Size:W-44.25"H-35"Glazing: 3/4"Overall Verified By: Luis P. Lomas, PE. Florida P.E. 62514 Laminated IG Created by Independent Third Party. Yes Evaluation Reports F L14604 R4 AE 510951.ndf FL14604— R4 AE NOA 14-0423,17.PD Created by Independent Third ParW1 Yes 114604.5 series 2461 impact vinyl SH flange Series 2461 Impact Vinyl SH Mange https:ik^vw.floridabUlcOng.agtpripr_app o.aspx?param=wGEVXQwtDqsw8ZVNfeBA7ba&84AYj7?k2bkEWyLZmltQcTSVe9Rdw%3do/.3d 213 5J9f6 Florida Bonding Code Olfine Limits of Use Certification Agency Cartificete Approved for use In HVHZ:No CAC NI012522,0_ 1-R?.ndf Approved for use outside HVHZ:Yes Quality Assurance Contract E�plri tion Date Impact Resistant,Yes 02/26/2017 Design Pressures t50/-50 InsWilation Instructions Other:Configuration: 0/X Vent Size: W-51"H-34.5"Glazing: RA4604 R4 II 08.005648. f 3/4"Overall Laminated IG Verified By: Luis P. Lomas,RE. Florida P.E. 62514 Created by Independent Third Party:Yes Evaluation Reports EL14604 R4 AE S10953A,odE i FL14604.R4 AE NOA 14-0423,17,PD Created by Independent Third Party:Yes 14664.6 Series FWI 1000 Impact Aluminum Series FWI 1000 Impact Aturnin.1m SH SH Limits of Use Certification Agency Certilicate i Approved for use In HVH :Yes. FL14604 R4 C ,AC NI409t)20i01-R2-slangda Approved for use outside Z:(E) pJ,igp04 R4 C CAC NI009020102-111-signed.odf impact Resistant:Yes EL14604 R4 C CAC N1009020103 R2-sioned:Ddf Design Pressure:N/A FL14§0 g4 C CAC N1010670,101-Ri of Other.See drawing 08-02476 for design pressures. EL14604 R4 C CAC NI010670- 1- ioned.odf Quality Assurance Contract Expiration Date 12/31/2019 installation Instructions ` fl14SQQ Rd II 08-02476.adf Verified By: Luis R.Lomas,P.E. Florida P.E. 62514 Created by Independent Third{Party: Yes Evaluation Reports is 1. 4604 114 AF 5132_32.odf EU4604 R4 AE NOA 74-04 113;,6.PDF EL14604 R4 AE NOA 14-02311'7 POF ° Created by Independent Third0arty:Yes pock Next ::1940 North Mon.=Street.IbilahassM FL 32399 Phone:850.487-1824 The State of Florida Is an AglEEO employer.QWaht 2007.2013 State of 52 dda.::Prlyacv Statement::A bility Statement::Refund Statement Under Florida law,email addresses errs public records,It you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity,Instead,contact the office by phone or by traditional mail.u you have am questions,please contact eso.487 ws.*Pursuant to Section 1 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Departmerit vdth an email address It they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal oddness,please provide the Department with an emali address which an be made available to the public,To detemslne if you are a licensee under Chapter 455,F.S•,please dl&b,, Product Approval Accepts: Wcuntymmuce t i t https:]www,floridabuilcing.org/pr/pr app rid.aspx7param=wPEVXQWtDgswBZVNfe8A7badr84AYj7t%2bkEtdWmlfgcTSVe9Rdw%3clo/o3d 313 j NOTICE OF PRODUCT CERTIFICATION CERTIFICATION NO: N1009020.01 R2 DATE: 04113/2011 CERTIFICATION PROGRAM: Structural COMPANY: Eastern CODE: 1783-1 REVISION DATE: 08!0512014 t k _ To verify that the"Notice ofProduct Certification"is valid,please visit www.NANUCertification.cbm to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAM AND ADDRESS PRODUCT DESCRIPTION Eastern Architectural Systems Series"FWI 1000"Aluminum 10030 Bavaria Road Impact Rated Single Hung Window Ft,Myers,FL 33913 Configuration:O/X Glazing:Laminate-3/16"Heat Strengthened Glass/0.100"HP Solutia/ 3/16"Heat Strengthened Glass Frame: W-1359mm(53.5") H-1943mm(76.5") Sash: W-1283mm(54.5") 11-912mm(38.25') SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: 5746 Pa (120 psi) Negative Design Pressure: 7152 Pa(150 psi) Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories Report No: NCTL-210-3753-1 Expiration Date: April 30,2020 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 t Tel: (804) 684-5124 { Fax: (804)684-5122 x NOTICE OF PRODUCT CERTIFICATION - ,rc vTPACERTIFICATION NO: NI009020.02 Rl h a Tr DATE: 04/13/2011 CERTIFICATION PROGRAM: S tructural COMPANY: Eastern CODE: 1783-1 REVISION DATE: , 08105/2014 To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be appliedto the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. t COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Eastern Architectural Systems Series"FWI 1000" Aluminum 10030 Bavaria Road Impact Rated Single Hung Window Ft.Myers,FL 33913 Configuration:O/X Glazing:Laminate-1/8"Annealed Glass/ 0.090"Safety-Plus II interlayer/ 1/8"Annealed Glass Frame: W-1349nun(53.13") H-2438mm(96") Sash: W-1281mm(50.44") H-1226mm(48.25") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure:12873 Pa(60 psf) Large Missile Impact Rated Product Tested By: Fenestrtion Testing Laboratory,Inc. Report No: 07-311/5417/02 Expiration Date: September 30,2020 Administrator's Signature: NATIONAL ACCREDITATION AND. MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway ; Bayes,VA 23072 Tel: (804) 684-5124 Fax: (804)684-5122 { t t i NOTICE OF PRODUCT CERTIFICATION 9 � CERTIFICATION NO: NI009020.03-R2 = M� DATE: 04%26!2011 Nr M CERTIFICATION PROGRAM: Structural poll COMPANY: Eastern � CODE: 1783-1 REVISION DATE: 06/16/2014 To verify that the"Notice ofProduct Certification"is valid,please visit www.NAMICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Eastern Architectural Systems Series "FWI 1000" Aluminum 10030 Bavaria Road Impact Rated Single Hung Window Ft.Myers,FL 33913 Configuration:O/X Glazing:IG-Laminate-1/8"Heat Strengthened Glass/0.090"Saflex by Solutia/l/8"Heat Strengthened Glass/0.250"Air Space/l/8"Heat Strengthened Glass Frame: W-1219mm(48") H-1829mm(72") Sash: W-1194mm(47") H-965mm(38") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: +75/-75 psf Large Missile Impact Rated Product Tested By:National Certified Testing Laboratories/Fenestration Testing Laboratory Report No: NCTL-210-3374-1/FTL-3598-File 02-311 Expiration Date: December 31,2019 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel: (804)684-5124 ' Fax: (804) 684-5122 NOTICE OF PRODUCT CERTIFICATION r � �Ce CERTIFICATION NO: NI010670.01-R1 � DATE: 10/43/2012 y � 8 .. ' CERTIFICATION PROGRAM: Structural COMPANY: Eastern ��a r R � ���,,y. _ " CODE: 1783-1 k` REVISION DATE: 02/89/2016 To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.c6m to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied io':thc product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Eastern Architectural Systems Series"FWI 1000SH"Aluminum 16341 Domestic Avenue Flange Frame Single Hung Window Ft.Myers,FL 33912 Configuration:O/X Glazing:IG-i/8"Annealed Glass/laminate-3/16"Heat Strengthened Glass/0.090"Saflex' Interlayer/ 3/16""Heat Strengthened Frame: W-1349mm(53.13") H-1981mm(78") Sash: W-1283mm(50.5") H-1003mtn(39.5") SPECIFICATION PRODUCT RATING f ASTM E1886-05/E1996-06 Design Pressure: +80/400 psf TAS 201/202/203-94 Wind Zone 4-Missile:Level D AAMA/WDMA/CSA 101/I.S.2/A440-05 Large Missile Impact Rated H-LC801349 x 1981 (53 x 78) Product Tested By: Element Materials Technology Report No: ESP009274P-I O/ESP009274P-11 Expiration Date: April 30.2021 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. ' 4794 George Washington Memorial Highway Hayes,VA 23072 Tel:(804)684-5124 Fax:(804)684-5122 i NOTICE OF PRODUCT CERTIFICATION " '''IG`"��'� ' , CERTIFICATION NO: NI010670-R1. f`o ' DATE: 05/25/2011 ' CERTIFICATION PROGRAM: Structural i COMPANY: Eaitern CODE: 1783-1 REVISION DATE: 08/05/2014 _ 4 To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label mustbe applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Eastern Architectural Systems Series"FWI 1000" Aluminum 10030 Bavaria Road Impact Rated Single Hung Window Ft. Myers,FL 33913 Configuration:O/X i Glazing:Laminate-3/16"Heat Strengthened Glass/0.090"Saflex I1IG PVB Interlayer/ 3/16"Heat Strengthened Glass Frame: W-1346mm(53") H-1956mm(77") Sash: W-1314mm(51.75") H-984mm(38.75"). SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: 3830 Pa(80 psi) Negative Design Pressure:4788 Pa(100 psf) Large Missile Impact Rated Product Tested By: Fenestration Testing Laboratory, Inc. Report No: 5682/11-749 Expiration Date: July 31,2020 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Bayes,VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 r , L. Roberto Lomas P.E. Engineering Evaluation Report 233 W.Main St Danville,VA 24541 Repoit No.: 513232 434-688 0609 rllomas re lrlomaspexem Manufacturer: Eastern Architectural Systems 10030 Bavaria Rd FT Myers,FL 33913 Product Line: Series FW)1000 Aluminum Single Hung Window—Impact Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida a rtment of Business and Professional Re ulation for Statewide Acce arca r Rule 61620-3.005 method 1{a} The product listed herein comp les with requirements of the Florida Building Coda. Supporting,Technical Documentation; 1. Approval document:drawing number 08.02476,prepared,signed and sealed by Luis Roberto Lomas P.E. 2. Test report No.:NCTL 210-3374-1 signed and sealed by Gerard J.Ferrara P.E. National Certified Testing Laboratories,Orlando,FL TAS 201-94 Large Missile Impact Test,Level D,Wind Zone 4 TAS 20.3-94 Cyclic Pressure loading t75.0psf design pressure 3. Test report No.:NCTL 210-3753-1 signed and sealed by Gerard J.Ferrara P.E. National Certified Testing Laboratories,Orlando, FL TAS 201-94 Large Missile Impact Test,Level D,Wind Zone 4 TAS 202-94 Uniform Static Air Pressure,+120.0/-150,Opsf design pressure,20.Opsf water penetration. TAS 203-94 Cyclic Pressure loading+120.0/-150Apst design pressure 4. Test report No.:FTL 5682/11-749 signed by Manny Sanchez. Fenestration Testing Laboratory,Medley, FL TAS 201-94 Large Missile Impact Test,Level D,Wind Zone 4 TAS 202-94 Uniform Static Air Pressure,+80.0/-100.0psf design pressure, 12.Opsf water penetration. TAS 203-94 Cyclic Pressure loading+80.0/-100.Opsf design pressure 5. Test report No.:ESPOO9274P-10 signed and sealed by Ramesh C.Patel P.E. Element Materials Technology,Wausau,WI AAMAANDMA/CSA 101/I.S.2/A440-05 Design pressure: +80,0%100.0psf Water penetration resistance i2.Opsf ASTM E1886-05 and ASTM E1996-05 ASTM E1886/E1996 Large Missile Impact,Level D,Wind Zone 4 ASTM E1866/E1996 Cyclic Load Test,+80.01-100.Opsf design pressure 6. Test report No.:ESPOO9274P-11 signed and sealed by Ramesh C.Patel P.E. Element Materials Technology,Wausau,WI TAS 201-94 Large Missile Impact Test,Level D,Wind Zone 4 TAS 202=94 Uniform Static Air Pressure,+80.0/-1 OO.Opsf design pressure, 12.Opsf water penetration. TAS 203-94 Cyclic Pressure loading+80.0/-100.0psf design pressure 7. Test report No.:FTL 07-311/5417/02 signed by Manny Sanchez. Fenestration Testing Laboratory, Medley, FL TAS 201-94 Large Missile Impact Test,Level D,Wind Zone 4 TAS 242-94 Uniform Static Air Pressure,t60.Opsf design pressure,9.Opsf water penetration. TAS 203-94 Cyclic Pressure loading t60.Opsf design pressure 8. Anchor calculations,report number 513166-1,prepared,signed and sealed by Luis Roberto Lomas P.E. �,t S 0 i�✓ 0 496 11fr TATE OF �,'ft►,S t p ipQ;'- .. 1 of 2 Luis R.Lomas,P.E. FL No.:62514 09/08/2014 t. L. Roberto Lomas P.E. Engineering Evaluation Report 233 W.Main St Danville,VA 24541 Report No.: 513232 434-688 0609 rllomas@lrlomuspe.com Limlfeflons and Condidons of use: • Maximum design pressure: Refer to installation drawing. • Maximum unit size: Refer to installation drawing. • Units must be glazed per ASTM El 300-04,refer to installation drawing for details. • This product is rated to be used in the HVHZ. • This product is impact resistant and does not require impact protection In wind borne debris regions. • Frame material to be extruded Aluminum 6063-T5. tnsfallation:Units must be installed in accordance with approval document,08-02476. Cerflf caflon of independence: Please note that i don't have nor will acquire a financial interest,in any company manufacturing or distributing the product(s)for which this report Is being issued.Also,i don't have nor will acquire a financial interest In any other entity involved in the approval process of the listed product(s). b NN • i # V • i • 'y,� W TAT OF O _ jNA1 2 of 2 Luis R.Lomas, P.E. FL No.:62514 09/08/2014 R Y MIA MD1ADE' MIAMI DADE COUNTY PRODUCT CONTROL SECTION I 1805 SW 26 Street,Room 208 DEPARTMENT OF:REGULATORY AND ECONOMIC RESOURCES(RER) idiami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F{78 r£j 31S 2599 NOTICE OF ACCEPTANCE (NOA) ww�vmlamtdad�e.¢ov/ecoaomv Eastman Chemical Company(MA) 730 Worcester Street Springfield,MA 01151 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has.been reviewed and accepted by Miami-Bade County RER Pro&ct pontroI Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction{AHS. This NOA shall not be valid after the expiration date stated below.The Miami-Dade County*net Control section(in Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the acceptedrimnner,the manufacturer will incur the expense.of such testing and the AHI may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet:the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florlda•Building Code, including the High Velocity Hurricane Zone. DESCItI MON:Sailex EP Clear or Color Glass Interlayers APPROVAL DOCUMENT: Drawing No.1814,titled"Saflex HP Interiayers for Laininat6d Glass",sheets I and 2 of 2,dated 04/06/2012,prepared by W.W.Schaefer Engineering&Consulting,P.A.,signed and sealed by Warren W.Schaefer,P.E.,bearing the Miami Dade County Product Controlrevision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:None LABELING:Glass lites laminated under this Product Approval shall be permanently marked in a corder of the glass with:a)Saflex IN,b)Glass standard specifications,c)Laminator identification mark and d) MDCA,standing for Miami Dade County Approved, LIMITATION:This approval does not include an evaluation of structural performance of this component. i RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in'the applicable building'code negatively affecting the performance of this product. TERMINATION of this NOA will occur atter the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any'other purposes shall automatically terminate this N. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the jab site at the request of the Building Official. This NOA revises NOA 012-1231.09 and consists of this page I and evidence page E-1,as Well as approval document mentioned above. The submitted documentation was reviewed by Carlos M.Utr6ra,P.E. NOA No.14-0423.16 es Expiration Date: April 14,2018 14 Approval nate:June 19,2014 Dtia��l Page 1 Eastman Chemical Company(MA) NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS ",S'uhmitted under NOA#12-1231.09" 1. Drawing No.1814,titled"Saflex IIP Interlayer for Laminated Glass",sheets 1 and 2 of 2, dated 04/002012,prepared by W.W.Schaefer Engineering&Consulting,P.A.,sighed and sealed by Warren W.Schaefer,P.E. B. TESTS "Submitted under NOA#09-0223.03" Test report Standard Date Signtitare 1. ETC-07-726-20120.0 ASTM D2843 " 07/17/08 Joseph L.Doldan,P.E. 2. ETC-07-726.20120.0 ASTM D1929 07%17/08 Joseph L.Doldan,P.E. 3. ETC-07-726-20120.0 ASTM D635 07117108" Joseph L.Doldan,P.E. 4. ETC-07-726-20120.0 ASTM C158 07/17/08 Joseph L.Doldan,P.E. "Submitted tinder NOA#081224.09" S. : ETC 03-191-13748.0 ASTM D'2843 07/25/03 Joseph L.Doldan,P.E. "Submilled under NOA #03-042101" 6. Omega 15542-109493 ASTM E 84 09/12/01 J.W Dougherty,P.E. 7. Omega 15542-109763 ASTM E 84 10)30101 J.W!Dougherty,P.E. 8. HIL 0003-0913-01 PA 201 &203 09/12/02 V.J Abraham,P.E.- -9. ETC 01-726-10071.0 ASTM C 158 - 10/15/01 J.L.'Doldan,P.E. 10. ETC 01-72641204.0 ASTM D 1929 09/24101 J.L;Doi"P.B. 11. ETC 01-726-11204.0 ASTM D 635 09/24/01 J.L.Doldan,P.E. 12. ETC 01-726-11204.0 ASTM D 2843 09/24/01 J.Lr,Doldan,P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources( ER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to 2010 and 51h edition(2014)FBC issued by,W.W. Schaefer Engineering&Consulting,P.A.,dated 04/10/2014,signed and sealed by Warren W. Schaefer,P.E. "Submitted under NDA 411-1102.10" 2. No financial interest letter issued by W.W.Schaefer Engineering&Consulting,P.A., on 10/24/2011,signed and sealed by Warren W. Schaefer,P.E. Carlos M.Utrers,P.E. Product Control Examiner NOAA No.14-0423.16 Expiration Date: April 14,2018 Approval Date:June 19,2014 i f PAi�I�A/y1 A B A SaflexO HP I" Product Description Manufactured By: Eastman Chemical Company Description: SaflexO HP is a clear andfor colored Polyvinyl Butyral between 10—3+4%plasticizer for lamination between two or more cites of glass. A typical glazing Is made of the following components(minimum thicknesses indicated-multiple layers of Interlayer to be used as necessary): A-2.3 mm 0.090-in Annealed Glass B-- .76 mm 0.030-in) Safiex@ HP lnterlayers ear or Colored) SECTION Clear Product Properties Denoription Test PV81101 PVB 1343 Flame Spread Index ASTM E84 10 70 Smoke Develop Index ASTM 1584. 6 165 Self Ignition Temp ASTM Di929 7WF 744°F Rete of Buming . ASTM D035 1.64 Int min. 0.79 lntmin smoke Density ASTM 2843 -- 0.7'Yo Avg Mod of Rupture ASTM 0168 DeHa:10% Delta:7.8'ft. vtvu� Before:11090 pal Before:6319 pat o _: +villi dei lfueiin Aflor.9978 psi After.Gogo pet . (1)Spechnen:laminated glance vAth SWUS HP type Werloyer (2)SaftXV HP We kAedgw by tlselt(unpmtoded)does NOT aamply with Ftodda OUNIV code. 0)Woalhedng per soallon 2992 of The FlWal Butldtm Coda Color Product Properties Material Realgnatton Smoke Rsnslty gating Wade Notification ti Vancava 0&We* ASTM D 2843 . . . sotar�coforenus Clear b96 ETCr11-72B-25Ot9.0 Whnb 20% ETC-11-720-25M.0 3 Dina 2% ET611.728.260= // Blue 6% ETC-41728.26W7.0 �,��- ,• X% Yebw OVO ETC-99?29-25U78.0 Red 10°/. ETC 11728 2A@82.0 4 CHARGEDFORLABEL WAIFiGMON OW12 t: y 8 GllAtiGED PRODWTNAME*6 GAF'tEX Osrrr2la9 2 IDELOTED RM&INO OPTION6 031240 'i• :3 ,,, ti i A013ED1►rrM"YER-6- ` WHIM REV.O FIESi;RiPT10N DATE Eastman Chemical Complany DEC I I W2/�� 730 WorcesteMmet,Springfield,MA 01161 Phone.413-730-3413,FAX 808.861=0127 WARREN W.$CF1A R,P.E, aaer €" 'title:SafiexO HP lntorlayers for Laminated Glass 1NW.BGNACtl111:ld0Ua ACOktUITigOVJ1. . Drawing No. Drawn by: Drawing Date Sheet No. 104 04/06/12 1 OF 2 F s SAFLEXO FIP drawing page 2 of 2 Extruded Multi-ia erProperties Footnote Deaoriptlon Teat ludo County Criteria llafivx®MuttNayer• Series(2) (1) ?est for Smoke t]enalty ASTM D 2843 Parted(,4M%) 28.8'4 (i) Self tgnitfon Temperature ASTM D 1929 Passed(>85fl'Ft 710 (i) state of humin ASTIR D 835 Passed(C•i:ii.a —• hxhrxin) ' (1) Average The of Burning ASTM D 835 --- 6 sec. (1) Average Extent of Buratnp ASTM D 635 •— 0.b1 in {1) (3) Average Modulus of Rupture ASTM G 158 Patted(<10.0%) De WA. Before:3542 pig Atter.4042 psi (1)Specimen:Laminaled glasswith U119 'Multi-layer Intedayer (2)Interlayer by llself(unprolec led)does NOT comply with Florida Building Code (3)Weathering per section 2812 of the Fforldo 8ultdinp Code . me cyst Notetsk ' SafieA HP can be constructed as layers of Saflex,Safiex MuWayer and VanoevaO PV13 Wedayers to add color, performance or thicknessl2f�the use of a Pi;T flirt». ; • r Sellex FIP type Interlayers are currently provided as:Sallex D series and Saftex Structural and encompasses products known as known as Sallex Ata,Sallex DO.88(ex DM,Safiex DN,Saftax RM,Safiex PS and SeBex PV. Pollex Inter'►ayers era known as Sallex,Sallex colors.Sallex Mul$layer,Slient(3lass Technololl f"and vanceva Color and can carry designations such as:AR CL,DA through D2„MG,NA,RA•through Rx,SA through SZ,and VA through VZ,(e.g.:R841,NA7f). Saflex MullMayer Interlbyers are known as.Q series(QA through 02) and Stent G)ass Technology (e.g,:QB 5i, QS 41 etc...). . 0 Saffox and Vanceve are registered trademarks of Eastman Chemical Company SlisntGiass Tiechnology Is a trademark of Eastman Chemical Company This Ise—component approval and does not Include an evaluation of structural performance of this component. Systems Incorporating this component chaff apply for ab NOA to the Mlaml4)ade Product; Control and shell submit test reports and other required documents showing that the syatetxje using this component wlil resist the toads according to chapter 18 of the F.A.C. Allot of authorized laminators shall �.lrpf�d with Mlamt•Dade County by Eastman Chemical Company 1'llf�utyif7titiSlMftfi PRt)pLICTVlSob .ti aaai�#aMNlt tart f'krLta ao moxptytntf r�tdr it+.FlarWa Ace-Wool”No 1+ '; ., ''� #trNMy� Ilidldiipy'GbAe r'• ' DEC 112012 $ by =,T= Eastman Chemlcal Company ri r: 730 Worcester Street,Springfield,MA 01151 .'• �•,f -. :* �� Phone:413-730-3413,FAX 608.861=0127 .S REN INFER,P.E. f!"' 'title: Saflex@ HP Interlayers for Laminated Glass 1NEER ww.scxusrea tioscoxraviuMPA Drawing No. Drawn by. Drawing Date Sheet No. r i 1814 04/06112 20172 PJtifD•i8t'Agt O1NIDit}S,tLNrxB p930.VriD61-y4�1t1 . t i MIAM!•DiADE I�tIAMI-DADS COUIaT -- PRODUCT CONTROL SECTION 11803 SW 26 Stred,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175.2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-,"2590 F{786)3152599 NOTICE OF ACCEPTANCE (NOA) www.tniamld8aagovitconnrgy Eastman Chemical Company(MA) 730 Worcester Street Springfield;MA 01151 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami Dado County RER Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid lifter the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Bade County) and/or.the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. N this product or material fails to perform in the accepted manner, the manrifaetirrer will'incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements ofthe applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone.. DESCRIPTION: Saflex Clear and Color Glass Interlayers APPROVAL DOCUMENT:Drawing No. 1813,Jitled"Saflex Based Interlayers for;Laminated GlaW' sheets 1 through 3 of 3,dated 0410612012,prepared by W.W.Schaefer Engineering&Consulting,P.A., signed and sealed by Warren W.Schaefer,P.E.,bearing the Miami Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. A%SILE IMPACT RATING:None LABELING:Glass laminated under this product approval shall be permanently marked in a corner of the glass with:a)Sallex,b)Authorized laminator's name,c)M.D.C.A.that stands for Miami Dade County Approved acrd d)Markings required by federal law for safety glazing. •LIMITATION:This approval does not include an evaluation of structural performance of this component. RENEWAL of this NOA shall be,considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration elate or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to'comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT:The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done. in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This?TOA revises NOA#12-1231.X0 and consists of this page 1 and evidence page B-1,as well as approval document meritibi ed above. The submitted documentation was reviewed by Carlos 1%Utrera,?.E. MLMr•DADECOt rTY NOA No.14-0423.17 ... ,i Expiration Date: May 21,2016 Approval Date:June 19,2014 Page•1 Qyfa912o14 Eastman Chemical Company WA) NOTICE OF ACCEPTANCE:EVIDENCE SUBMITTED A. DRAWINGS "Submitted under NOA#12-1231.X0') 1. Drawing No.1813,titled"Saflex Based Interlayers for Laminated Glase"sheets i thmugh 3 612 of 3,dated 04/0012,prepared by W.W.Schaefer Engineering&Consulting,P.A.,signed and sealed by Warren W. Schaefer,P.E. B. TESTS "Submitted under NOA#11-0325.05» Test Report No. Standard Date Signature 1. ETC-11-726 25078.0 ASTM D1929/D2843 03/08111 Joseph L.Doldan,P.E. 2. ETC-11-726 25076.0 . ASTM D1929/D2843 03/08/11 Josob L.Doldan,P.E. 3. ETC-11-726-25080.0 ASTM D1929/D2843 03/08/11 Joseph L.D'oldan,P.E. 4. ETC-11-726-25077.0 ASTM D1929/D2843 03/08/11 Joseph L.Doldan,P.E. 5. ETC-11-726-25079.0 ASTM D1929/D2843 03/08/11 Joseph L.Dolden,P.E. 6. ETC-11-726-24882.0 ASTM D1929/D2843 03/08/11 Joseph L.Doldan,P.E. 7. ETC 96-191-3253.0 ASTM 026&C158 11/05/97 Joseph L.Doldan,P.E. 8. ETC 98.191-5523.0 ASTM G26&C158 05/11/99 Joseph L.Doldan,P.E. "Submitted under NOA#09-0223.05" 9. ETC-07-726-20120.0 ASTM D2843 07/17/08 Joseph L.Dollop,P.E. 10. ETC-07-726 20120.0 ASTM D1929 07/17/08 Joseph L.Dolda T.E. 11. ETC-07-726-20120.0 ASTM D635 07/17/08 Joseph L.Doldan,P.E. 12. ETC-07-726-20120.0 ASTM 0158 07/17/08 Joseph L.Doldan,P.E. C. CALCULATIONS: 1. None. D. QUALITY ASSURANCE ' 1. Miami-Dade Department of Regulatory acid Economic Resources(NER) E. MATERIAL CERTIFICATIONS 1. None, F. STATEMENTS 1. Statement letter of code conformance to 2010 and 5h edition(2014)FBC,issued by W. W. Schaefer Engineering&Consulting,P.A.,dated 04/1012014,signed and sealed by Warren W. Schaefer,P.E. "Submitled under NOA #ll-110A11" 2. No financial interest letter issued by W.W.Schaefer Engineering&Consulting,P.A.,on 1=41201 1,signed and sealed by Warren W.Schaefer,P.E. e9 20 Carlos X.Utrera,P.E. Product Control Examiner NOA No. 14.0423.17 U` Expiration Date: May 21,2016 Approval Date:June 19,2014 E-1 i • t ABA SAW PVB interlayer (Clear&/or colored Seflex 0.35 J—50%) Product Description Manufactured By: Eastman Chemical Company Description Clear or Colored monolithically extruded Interlayers made of polyvinyl butyral resin and triethyleneglycol b1s(2 ethyl hexanoate)plasticizer at.concentrations between 35 and 50%. Interlayer Is offered under the brand names of Saflexe and Vanc eva's for lamination between a minimum of two glasses. A typical glazing Is made of the following components(minimum thicknesses Indicated-multiple plies of interlayers tobe used as necessary); SECTION PRwuor wlvr.'i -2.3 mm(3/32-45)n Annealed ass a ootr tylag wide ft FlW* —0.76 mm (0.030-in) Saf ex* and/or VAncevalk Interlayers " �' rdsvlsEO » wplMrr et Mtrnntrot ! i' Product Properties Descrt�tt� Ust S$nft 4 Q 30%cza (1)861f-Ignition temperature ASTM D 1929 760°l' (1)Smoke Density ASTM D 2843 6% (1)Rate of Burning ASTM D635 a 25 mm mark(not reported) i (1)Time of Burning ASTM D635 {5 sea (i)Extent of Burning ASTM D035 0.31 In (1)Avg Mod of Rupture ASTM 0158 (1)Weathering(3) i Befor*Lj Attejpw 2559 psi 2857 (1)Specimen:Laminated glass with SaRW and/or Vencevao Interlayer (2)int$rlayer by Itself(unprotected)does NOT comply vAh Florida Building Code (3)Weathering per section 2612 orttie Florida Building Code t; ; tieicjap�,Vanpeva are registered trademarks of Eastman Chemical Company +0 ,*. !' • ' C Combined Multi-layer and SaAex;removed IIIG name 12/12111 i 8 Renewed FlammebiilMet data 03/21111 A Combined RM&ilia Products Info one document 04102!03 `.<�'•. ReyO Description Date Eastman Chemical Company 2012 730 Worcester Street,Springfield, MA 01151 Phone:413-730-341$ FAX 508-861-0127 Warren afar,P.E. Str4cluol Ongineer Title: Saftee Based lnteriayers for Laminated Glass P.EAV 44135 W.W.Schaefer E ' eering&Consulting,P.A. Drawing Sheet Drawing Revisions, Structural Gonsuiting Engineers Number Number Date Date 1486150'Court North .1813 1 of 3 04108/12 Palm Beach Gardens,Fl 33418 Phone:581-744-3424 Salta*PVB Interlayer continued Saflex@ Multi-layer Product Properties • Footnote Description Tent Dade County Siaflex Muld- Criteria layer Series (1) Test for Sfnoke Density ASTM D 2843 Passed(<75%) 2616% (1) $elf ignition Temperature ASTM D 1928 Passed(>66WF) 750°F (1). Rate of Burning ASTM D 635 Passed(C-1:<1.0 tnlmin) (1) Average Time of Burning ASTM D 635 --- <5 sec. (1) Average Ment of ASTM D 835 0.61 In Storting (1)&(3) Average Modulus of ASTM C 166 Passed(<10.0%) DeltaA.00A Rupture Before:3842 pal Aftar.•4942 psi (1)Speclmen:Laminated glass with 5aliexOMulll-layer interlayor (2)Interlayer by.lisell(unprotected)does NOT comply with Florida Building Code (3)Weathering per section 2812 of the Flodda Buftng Code Saflex@ and VancevaOD Solar/Color and Colorant Prope�rtles Material Ooaignatlon Smoke Venally Rating Dade N60flcation# ASTM D 2849 vemova 0&sag"—Clear 6% ETC4172&25078,0 Venceva 0&Satter While 209k ETC41-728-25076.0 Vanceva O&8~—Black 2% ETC-11 726.26080.0 Venceva 0&Salicyl®--Blue 66A ETC-11728 26Q7T.0 vanceva®&Saliew--Yeflaw 9°!e. ETC-11728.2078.0 j Venceva 4i►&Saflex®—Red 10°! ETC-11.728.24662.0 VOW ••f I ' . - `% httwp�or�in � ��C1'I0iVL98b r-:;, WS eq?wtlA ttK rik NO 12-12J - :,. lratldty t704r 1 2012 Eastman Chemical Company � � ° •,' = ' :' ' 730 Worcester Street,Springfield,MA 01151 Sc a P>E. Phone;413-730-3413 FAX 60841-027 �+alt �t;;4;�t�turat ] Bar P.E.No 44 35 Title: SaflaxO 1110 Based- lnterlayere for Laminated Glass W.W.Schaefer Engineering&Consulting,P.A. Drawing Sheet Drawing ReralslOns Structure]Censuhing Engineers Number Number Date Date 7480150th Court North Palm Beach Gardens,FI 33418 1813 203 04/06192 Mone-661-744-2424 3 Satter PVB Interlayer continued Sapex@ Interlayers are known as Safiex,Safiex colors,SafWc Multilayer,"SlIentUass Technologym and VancevaO Color Vanoeva and/or Saflex are known as:AR,CL,DA through DZ,,MG,NA,RA thiough RZ,$A through SZ,and VA through VZ.(e.g.:RB41,.NA71). SaitexV Muld-layer interleyers are known as:Q series(QA through OZ) and Silent Glass Technology (e.g..,QB 61,QS 41 etc...}. eSaflex and Vanceva are registered trademarks of Eastman Chemical Company *"r Silent Glass Technology Is a trademark of Eastman Chemical Company This Is a component approval and does not Include an evaluation of struokwal performance of this component. Systems incorporating this component shall apply for an NOA to the Miami- Dade Product Control and shall submit test reports and other required documents stiowJng that the systems using this component will resist the loads according to chapter 16 of the F.B.C. A Nstofauthorized laminators shall be filed with Miami-Dade County by Eastman Chemical Company •.,.` �• • ',�:'�, fl%tQOtJ471t1&Y� t;7ttifilt#6't'I2$Vt.98D - a fMtFllortdrr !lABwidr!!rl�lotldn f. Aalt Ne Acotpt�ar+b fel TO �rrxfiur anntrot DEC 1'12012 Eastman Chemical Company 730 Worcester Street,Springfield,MA 01151 Warren W.Scha er,P.E. Phone.413-730-3413 FAX:508-861.0127 Structu;74- irteer P.E.N135 Title: Saftee ING Based- Interiayers for Laminated Glass WA Schaefer En re ring&Consulting,P.A. Drawing Sheet Drawings . Revisions Structural ulUng Bnglneere Number Number Date Date 7480160th Court Nodh Palm Beach Gardens,F133418 1813 Sof 3 04108/12 Phone:56'1»744-3424' - r1 Rensor+s rscv o�scawrau oar IPPR&.'o NO 15.FOR FRAME ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #14 WOOD SCREWS WITH 1, THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH SUFFICIENT LENGTH TO ACHIEVE A 1 7/1.6' MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE REQ I EM F THE FLORIDA B I I ODE INCLUDING THE HVHZ. ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY 16. FOR FRAME ANCHORING INTO MASONRY/CONCRETE USE 1/4' TAPCONS WITH SUFFICIENT TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. LENGTH TO ACHIEVE A 1 1/4' MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2' WINDOW UNITS MUST BE DETAILS. ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED 17.FOR FRAME ANCHORING INTO METAL STRUCTURE USE #14 SMS OR SELF DRILLING SCREWS INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR MASONRY. CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. WALL LOCATE ANCHORS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. All FASTENERS TO BE CORROSION RESISTANT. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2' OR GREATER, BUCK SHALL BE SECURELY 19.INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR FASTENED TO MASONRY. CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. A. WOOD - MINIMUM SPECIFIC GRAVITY OF G-0.42 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). THE ARCHITECT OR ENGINEER OF RECORD. D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063-T5 1/8' THICK MINIMUM 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. FOR FIN INSTALLATION SHIM AS NEEDED_ FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16' OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4'. 9. SHIMS SHALL BE LOCATED. APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEETS 2-7 FOR GLASS DETAILS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR FIN INSTALLATION INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8' MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED:.08/2SM14 E8 . o< 8fern " TABLE OF CONTENTS - .arwve,rtam�mn �V:\GEAI�q•.'��.5 SHEET NO. DESCRIPTION 1 NOTES SERIES FWI 1000 IMPACT * 0 SINGLE HUNG WINDOW 2 — 6 ELEVATIONS NOTES 7 CROSS SECTIONS AND B.O.M. DRAww 8 — 11 INSTALLATION DETAILS saw �� OS X076 - 12 COMPONENTS NTS 08/20/14 1 OF 12fill REMONS pty EPROM DATE APPROVED 48" MAX FRAME WIDTH 48" MAX FRAME WIDTH 13' 5" MAX I I 13" MAX O.C. 5" MAX 5' MAXMOAX 5" MAX 5" MAX 5" MAX I !� / 12" / 10" / MAX. O.C. / MAX O.C. / 72" 11/16" MAX 72" FRAME MAX 1/8" HS HEIGHT FRAME / HEIGHT 090" SAFLEX BY SOLUTIA Z1/8" HS 1/8' HS EXTERIOR ffaERIOR / ALUMINUM SPACER SYSTEM / 3/4" BITE STRUCTURAL SEALANT SETTING ^^ SIKAFLEX 552 ETT GLAZING DETAIL A 5" MAX 5" MAX SERIES FWI 1000 IMPACT SINGLE HUNG WINDOW SERIES FW/1000 IMPACT SINGLE HUNG WINDOW EXTERIOR VIEW FRAMEINSTALLAT/ON EXTERIOR VIEW FIN INSTALLATION DESIGN PRESSURE RATING IMPACT R47M t75.OPSF LARGEANDSMALL MISSILE IMPACT MISSILE LEVEL D,WIND ZONE 4,AND HVHZ INIM GLAZING A NOTES: 1. SASH SIZE: 47" X 38 2. D.L.O.: 42 3/4" X 31 5/8'. 3. HARDWARE: a.(1) METALLIC CAM LOCK-LOCATED-MIDSPAN OF TOP RAIL.. _•�_ � F �� . o�AtAND ANCHORED TO FIXED MEETING RAIL POWb.(2) SPIRAL BALANCE LOCATED ON EACH JAMB. ms."«�»::iy =- '°"' `V ` \GENBc.(2) BALANCE SHOES LOCATED ON EACH SASH BOTTOM RAIL ENO. SERIES FWI 1000 IMPACT • 0 4. NO REINFORCEMENTS_ SINGLE HUNG WINODW •ELEVATIONS �0E OF '"��• pRAWM: V t:MD. REV IO�►•:"1CR1a�'►�C�� V.L. 08-02476 — //SSS/Q(��L� O�` I-NTS °" 08/20/14 JTAM2 OF 12 ��T/IIIIHI%Xj Ilk 53 1/2" MAX FRAME WIDTH ams ~ 53 1/2- MAX FRAME WIDTH wLv ots�ivnow w>E ,lrwtouEp 5" MAX 10 5' MAX MAX O.C. 5" MAX 13 5" MAX 1 11 MAX O.C. 5" MAX �-- 5" MAX _. 8" 1� / MAX O.C. �(( 9' MAX O.C. 76 1/2" MAX 76 1/2' FRAME MAX 1/2" HEIGHT FRAME 3/16" HS HEIGHT j 100" HP SOLUTIA 3/16" HS f ( / DCTERIOR INTERIOR 1/2" B� SETTINITE G n, STRUCTURAL SEALANT BLOCK SIKAFLEX 552 5' MAX 5" MAX GLAZING DETAIL B SERIES FWl 1000 IMPACT SINGLE HUNG WINDOW SERIES FWl 1000 IMPACT SINGLE HUNG WINDOW EXTERIOR VIEW FRAME WSTALLATXIN EXTERIOR VIEW FW INSTALLATION DESIGN PRESSURE RATING IMPACT RATWG +120.01-150,OPSF LARGEANDSMALL MISS RE IMPACT MISSILE LEVEL D,WIND ZONE♦,AND HVFIZ WRHGLAZWG B NOTES: rnry« tiww r�mea 1. SASH SIZE: 50 1/2" X 38 1/4", _ ` .E�i1ri1 ._....:sm., x.°F,ra.. ��111�R11�1//�fjt! 2. O.L.O.: 47 11/2" X 31 3/4"• ., ,` w+ .m _ `,`�.�g���,EN p y�yi'i= 3. HARDWARE: - o.{1) METALLIC CAM LOCK LOCATED MIDSPAN OF TOP RAIL SERIES FWI 1000 IMPACT Q tlr. AND ANCHORED TO FIXED MEETING RAIL. SINGLE HUNG WINODW b. (2) SPIRAL BALANCE LOCATED ON EACH JAMB. ELEVATIONS ,oa► c.(2) BALANCE SHOES LOCATED ON EACH SASH BOTTOM ,n �. 4. NORAILRE REV.LINFORCEMENTS. nuwwo 08-02476r ✓�/ bRtCti•�' `� —NTS �^� 08/20/14 a OF 12 �f�rjlaNA� Y' RVASIWIS 53' MAX FRAME WIDTH REy 53' MAX FRAME WIDTH DESCRIvnoR DATE APVRU" 14 5" MAX �"r MAXD.C. 5" MAX 3 5' MAX �MAX0.C. � 5" MAX ' 5' MAX 5' MAX E_ T J / I / 12" / 10" MAX O.C. MAX O.C.77" 77" 3/16" HS MAX MAX .090' SAFLEX IIIG BY SOLUTIA FRAME FRAME HEIGHT HEIGHT 3/16" HS EXTERIOR INFERIOR 3/4' BITE SETTING nr-i STRUCTURAL SEALANT BLOCK SIKAFLEX 552 GLAZING DETAIL C 5" MAX 5' MAX 1_-r SERIES FWI 1000 IMPACT SINGLE HUNG WINDOW SERIES FWI 1000 IMPACT SINGLE HUNG WINDOW EXTERIOR VIEW FRAME INSTALLATION EXTERIOR VIEW FIN INSTALLATION DESIGN PRESSURE R47ING IMPACT RATING +80.0%100.OPSF LARGEANDSMALL MISSILE IMPACT MISSILELEVEL D,WIND ZONE 4,AND HVHZ WM4 GLAZING C NOTES: 1: SASH-SIZE: 51 3/4" X..38.3/4". MO�"�or 2. D.L.O.: ,ss a7 3/a" X 34". t _ 3. HARDWARE: .. a.(1) METALLIC CAM LOCK LOCATED MIDSPAN OF TOP RAIL �� �+ �°"�'nD1 � vJ•V���N��'.p/� AND ANCHORED TO FIXED MEETING RAIL. SERIES FWI 1000 IMPACT *• 0 6 *G: b.(2) SPIRAL BALANCE LOCATED ON EACH JAMB. SINGLE HUNG WINODW t a.(2) BALANCE SHOES LOCATED ON EACH SASH BOTTOM ELEVATIONS �_ ►��1E OF y, �: RAIL END. oRAww. Ow0 NO, REV �i�.•:2bR1�1;� 4. NO REINFORCEMENTS. O scene oaTt OS—�0�'i6 NTS OB 20 14 4 OF 12 4' 53 1/8" MAX FRAME WIDTH 53 1/8' MAX FRAME WIDTH rmv o[SCRwnoN DATE nn*MM 5" MAX �'- 14� 13* MAX 10 C. S" MAX 5' MAX �MAY—4 � 5' MAX 5 MAXmA-X— 5" MAX T— T— / J / 12" / 10' / 7/8' MAX O.C. J MAX O.C. f fJ 3/16" HS .090' SAFLEX BY SOLUTIA 78" 1/8' ANN. 3/16* HS MAX MAX7EXTERIOR FRAME FRAME I INTERIOR HEIGHT HEIGHT I ALUMINUM SPACER SYSTEM /// 3/4' BITE 1 / STRUCTURAL SEALANT /f /J SETTING SIKAFLEX 552 BLOCK LAZING DETAIL D t 5' MAX 5" MAX SERIES FWI 1000 IMPACT SINGLE HUNG WINDOW SERIES.FW/1000 IMPACT SINGLE HUNG WINDOW EXTERIOR VIEW FRAME INSTALLA77ON EXTERIOR VIEW FIN INSTALLATION DESIGN PRESSURER47ING IMPACT RA77NG +80.01100.OPSF LARGEANDSMALL MISSILE IMPACT MISSILE LEVEL D.tWNDZONE 4 AND XVNZ WTH GLAZING D NOTES: 1. SASH SIZE: 50 1/2" X 39 1/2". 2: HARD: 47 1/2" X 33 t. 2. - \g11tIIJ11 3. HARDWARE: M" .... �. eowemwoF _ wYears�a..ccnr'aeax,cre ..tYM1]. ETK II9JlY. _ ...� �I o.(1) METALLIC CAM LOCK LOCATED MIDSPAN OF TOP RAIL , �tti�'� •.d;�+'/�"" ' AND ANCHORED T4 FIXED MEETING RAIL. 3 ',_...- �».. a .»� •m*wxrtanmo.*on `�V�.'�CEA►�+.',qjf�i� 40 b.(2) SPIRAL BALANCE LOCATED ON EACH JAMB. SERIES FWI 1080 IMPACT tIP�• p %41.. c.(2) BALANCE SHOES LOCATED ON EACH SASH BOTTOM SINGLE HUNG 0 IMPACT RAIL END. ELEVATIONS ,NDOW AT 4. NO REINFORCEMENTS. DRI"; owa No, RLV : ;;�roR*,dh� ': CALF MTS of 08/20/14 08'S6OF 12 *lltf Jl�itj llll�b,1`` r- 3 1/"8-+":MAX:FRAM:EM:D 53 1/8" MAX FRAME WIDTH REV510N5 y I REV UESCPIPSFOH OATC 1J�ROVEC 13'` 5' MAX 1 MAXO0 C. 5' MAX MAX MAX O.C. 5` MAX �5' MAX MAX O.. _ 5- MAX C. / MAX O.C. / j --� f/ 3/8" -4 1/8" ANN. 96• 090" SAFETY-PLUS II lAA 6" MAX 1/8" ANN FRAME ME HEIGHT HEIGHT EXTERIOR !MERIDA I 3/4' BRE SETTING STRUCTURAL SEALANT / BLOCK SIKAFLEX 552 J !J GLAZING DETAIL E 5" MAX 5" MAX __RIES FWl 1000 IMPACT SINGLE BUNG WINDOW SERIES FM 1000 IMPACT SINGLE HUNG WINDOW EMRIORVIEWFRAME/NSTALLATICRV �. �-�-� EaERIORVIEWFININSTALLATIDN DESIGNPRESSURERATM IMPACTRAT1Nt; NOTES: t60.0PSF LARGEANDSMAtt 1. SASH SIZE: 50 7/16" X 48 1/4". M/SS2EIMPACT 2. D.L.O.: 47 5/8" X 43 5/8" MISSIL'ELEVM-D., - _.... 2 ►_ �y berry as X1 11 1 3. HARDWARE: W1TNL,`LiZiNGE gatfi�'I-//-._. ._. emr.. - tti�k\Q to c.(1) METALLIC CAM LOCK LOCATED MIDSPAN OF TOP RA .t. 'tc!v..2'::`^."": nvn°wr•s+w `y\>�i \V`EjVdi••'�jlp/i AND ANCHORED TO FIXED MEETING RAIL. ` • V R a• o b.(2) SPIRAL BALANCE LOCATED ON EACH JAMB. SERIES FWI 1000 IMPACT • p c.(2) BALANCE SHOES LOCATED ON EACH SASH BOTTOM SINGLE HUNG WINDOW RAIL END. ELEVATIONS �' ,� ATi—or ' 4, NO REINFORCEMENTS. z 5. ALL UNITS RATED UP TO 16O.OPSF MAY BE INSTALLED DR'WH0 e,dC Ho. REV r, OR�b.:�� VlITHOLTt ANCHORS AT THE SILL. scuE NTS °ATE 08/20/14 08-02476T60F 12 f'`J�s»111I�111�W, ArL BILLOF MATERIALS FOR ILLUSTRATION PURPOSES ONLY rrEM No.:PAarNo.: FFRAM HEA FAS A C1URER ALUM6 -ffi INUM FOR INSTALLATION DETAILS as o 2 FRAMESILL EAS ALUNNUM6063-T6 REFER TO SHEETS 9-12 3 HI-RISESILL EAS ALUMNUMOD63-T6 4 FRAMEJAMB MFASALUNNUMGM-T6, WWNUM6063-T6 5 FIXEOMEETINGRAILUNflNUM6063-T6 6 APPUEOFIN 7 MEETINGRAIL MNUM6063-T6 8 UFT RAIL NUM6063-T69 HI-RISEUFTRAILUMINUM6D63-T610 SASHJAMB AWMINUMS063-T6 11 11 IG GLAZING BEAD EAS ALUNNUMGM76 12 MONOLITHIC GLAZING BEAD EAS AWMNUM6063TG 13 CAOWELLSPIRAL BALANCER EAS EXTERIOR INTERIOR 14 SASH LOCK EAS DIE-CASTZINC JS BALANCER PIVOT LOCK EAS 16 VENTSTOPS EAS 12 14 17 BALANCER PIVOT BARS EAS 1s UFTRAILBULB EAS VINYL 19 FRAMESILLBULB EAS VINYL 5 7 20 SASH WEATHERSTRIPPING EAS 21 RAILWEATHERSTRIPPING EAS 12 EXTERIOR INTERIOR 11 i 21 s 19 18 12 13 20 10 19 3 8 2 INTERIOR 18 VERTICAL SECTION EXTERIOR _. ._ ... _ w A■anea t� ADWSMW e.em+a VERTICAL SECTION JR� 0SERIES FWI 1000 IMPACT SINGLE HUNG WINODW-02476 10 B.O.M., CROSS SECTIONS do GLAZING DETAILAT HORIZONTAL SECTION owwn owe uoi'''�►� ORLO�;6�!`� ISCALE NTS 08/20/14 14 7 OF 12 REASONS REV OESCR"OR MTE n�ROVEo METAL STRUCTURE BY OTHERS 1/4' MAX. SHIM SPACE APPROVED SEALANT X14 SMS OR SELF DRILLING SCREW 1/4' MAX. r SHIM SPACE L- I INTERIOR 7/6' MIN. EDGE DISTANCE t 14 EXTERIOR INTERIOR SE ELF SMS OR F DRILLING SCREWS } i METAL STRUCTURE EXTERIOR BY OTHERS BACKER ROD do APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION P14 SMS OR SELF DRILLING SCREW BACKER ROD & APPROVED SEALANT 1/4' MAX. SHIM SPACE METAL STRUCTURE BY OTHERS VERTICAL CROSS SECTION METAL STRUCTURE INSTALLA7ION STANDARD SILL SHOWN,HI RISE SIMILAR ADNWONOF NA _.•. - IEI®MVAINIbIC fllwOl9JR� \vY owl'o-s7{1�l�I r-y:;J��r.+tiww�. arm IOR WP1RIlGlmllmlf NOTES. SERIES FWI 1000 IMPACT 1.INTERIORANDEXTER/ORFINISHES.BYOTHERS. SINGLE HUNG WINODW NOT SHOWN FOR CLARITY INSTALLATION DETAILS l2.PERIMETER ANDJOINTSEALANTBYOTHERSTOBE �A owc�.DESIGNEDINACCORDANCEWRHAS7ME2f12 V.L. 08-02476 z/ it seuE NTS °"� 08/20/14 ��T9 OF 12 ��I/IiNjtIj% � CONCRETE/MASONRY 2 1/2" MIN. rtty D=RMn0N �� APPROVED BY OTHERS jEDGE DISTANCE G •• •e 1 1/4- MIN. • a • ° e EMBEDMENT { OPTIONAL 1X BUCK SEE NOTES 3 — 7 SHEET 1 1 1/4' MIN. 1/4" MAX. EMBEDMENT BACKER ROD SHIM SPACE & APPROVED CONCRETE/MASONRY SEALANT BY OTHERS ' 1/4- TAPCON OPTIONAL 1X BUCK •'Q 114- MAX. SEE NOTES 3 — 7 �' SHIM SPACE SHEET 1 EXTERIOR INTERIOR 1/4" TAPCON .' INTERIOR �.b 2 1/2' , MIN. " EDGE DISTANCE EXTERIOR BACKER ROD & APPROVED SEALANT 1/a^ TAPCON JAMB INSTALLATION DETAIL CONGRETEA64SONRY INSTALLAT ION BACKER ROD & APPROVED 1/4' MAX. SEALANT r SHIM SPACE NOTES. OPTIONAL 1X BUCK _IL 1.INTERIOR AND EXTERIOR FINISHES.BY OTHERS, SEE NOTE 3 — 7 NOTSHOWNFORCLARITY. SHEET 1 ! 2.PERIMETER AND JOINTSEALANT BY OTHERS TO BE DESIGNED INACCORDANCEWMAS1ME2112 " a 1 1/4' MIN, • 'EMBEDMENT— /0/.0 ��/ y\G�NV-'..s.^. �e •� • • r SERIES FWI 1000 IMPACT *' V CONCRETE/MASONRY 2 1/2" MIN' SINGLE HUNG WINODWBY OTHERS EOGE DISTANCE INSTALLATION DETAILS S. ' AT VERTICAL CROSS SECTION DRAM: owc eu. RLv i"c�.�[QR*,9* STANDARD EIMSHOWN,NSTALRISTRSIMILAR V.L. OB-02476 — ����I�B�ON� scut NTS °A� 08/20/14 SRS 10 OF 12 RMONS 1 3/8" MIN. oESCmPnoN aQE APPRMO (j10 WOOD EMBEDMENT WOOD SCREW FRAMING BY OTHERS �--_ 1/4 MAX, SHIM SPACE 7/18" MIN EDGE DISTANCE WOOD FRAMING 1/4" MAX BY OTHERS I SHIM SPACE i INTERIOR 1 3/8" MIN. EXTERIOR INTERIOR EMBEDMENT M STANE #10 WOOD SCREW 7/16" IN EXTERIOR EDGE DIC JAMB INSTALLATION DETAIL IV00O FRAMING OR2X 8VCKrNSrALLATM t/4" MAX NOTES: SHIM SPACE 1.LVMR10RAND EXTERIORRNISHES.8YOTHERS, --T NOTSHOM FOR CLARRY. 16" MINZPERMWMRANDJO#VrSEALANrOYOTHERSTZTSE 7/16- DESIGNED IN ACCORDANCE IWMASME2112 EDGE DISTANCE #10 WOOD WOOD SCREW FRAMING _. . . cmrAwwaanenxae+nan { ! IIJ Ih 1 Eastern- EMBEDMENT MIN. BY OTHERS VERTICAL CROSS SECTIONwi SERIES FWI 1000 IMPACT WOOD FRAMWGOR2X8UCKINSTALLATTAV SINGLE HUNG WINDOW i 'y �` INSTALLATION DETAILS TAT OF V.L. NTS 0A1E 08/20/14 09 5 2416 OF 12 �r'ffi$1a11A11% b`�` RCVISIONS 3 3J8" — DCSCRVPY v D.� �rvawm 3 7/16" �- 3 5/16" 1 11/16" 3 3/8" Lw�fl 4 5/is" T— 3 tj16 7 13{j16" 2 5/8" 2 9/16" L t I li FRAME HEAD FRAME SILL FRAME HI RISE SILL FRAME JAMB FIXED MEETING RAIL ALUMINUM6063-TS 2 ALUMINUM606346 Q ALUMINUM6W-T6 �4 ALUMWUM6083-T6 (5 ALUMINUM6=-T6 .062'THICK OW THICK .06Y THICK .052"THICK OW THICK 2 3/8" I--2 --{ 4---2 9/16" 3/8" � II — 1--5/16" 1 7 9/16" 1 3 13/16' 2 1/4., 2 1/2- 7 T--- L 1 5j _L___� L L—i1 3/8" APPLIED FIN MEETING RAIL LIFT RAIL Hl RISE IMPACT UFT RAIL SASH JAMB 6� ALUMINUM 60&3-T6 (7 ALUMINUM6083-TB 8 ALUMINUM 60046 �9 ALUMINUM6W3-TS 10 ALUMINUMSOS3-T8 OG2'THICK CW THICK .052'THICK 062'THICK 052'TTfICFC 7 5/16" 15/16" F. 15/16' 17 �.� � A,)% _INSULATING BEAD GLAZING BEAD i 1 ALUMINUMSdq-T6 12 ALUMINUMAW-70 'THrcx SERIES FWI 1000'IMPACT *� p SINGLE HUNG WINODW COMPONENTS 0' aRawN m Na. REV i is.LQ ttS!•� � V.L. Darz 082476 NTS 08/20/14 12 OF 12 4/142016 Florid Building Code Opine ■,+:- IEEAr IF0.10,00 . Mm I•�7tUd rlanathnard0! eas Home i.L09 In I User Registration I Hot Topics ( Submit Surcharge I Stats a Fads I Publications I FEC Staff I BCIS Site Map I Links I Seirdi I Busines Productppro Atfel Profess I us2R:Pit User Regulation % Product Aooroval menu>PrQdv&or ApoligtIgn search>Appiratlon Liat r, - Search CriteriaRefine Search G1de Version 2014 '' Flit "i747Y2<,, Application Type ALL Product Manufacturer ALL } Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Plumber or(dame ALL Product Description ALL Approved for use In HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Resuits-A Ilcations M 7 Mantafeetttrer Vagidated By r4tatills F J7472� Revislan, Eastern Archltettural Systems Keystone Approved fL>Jk FL17472 2 Certifications,Inc. Model:`HVHZ Clipped Aluminum Tube.Mullion (717)932-85tH ,Description�HYHZ Clipped Aluminum Tribe Mullign Yertl"e'al, Horizontal,T and X'tonfigurations Category Windows ;Stabc6teBory:=Mullions *Approved by DBPR.Approvals by DBPR shell be reviewed and ratified by the POC&Wor the commission If necessary. CWP-d Lis::Std:With Monroe street.TallebAmm FL 323oa Big=850-487-1624 The State of Florida Is an AA/EEO employer.Convrlotd 7007-2013 State of FM&.::Privacy Statement::Aooesslhility Statement;;Refund Statement Under Florida law,email addresses are public records.U you do not ward yaw e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pwmnt to Section 455.275(1),Randa Statutes,effective October 1,2012,Ilcensees licensed under Chapter 455,F.S.must provide the Department with an email add+ess H they have one.The emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not rush to Supply a personal address,please provide the Department with an ernall address which can be made available to the public.To determine H you are a licensee under Chapter 455,F.S.,please dict.. Product Approval Accepts, KD®ERV stY+nTjt St►:Yt�lt'If I i i I I i I f i s i F hM*://Aaridabuildirm.orWpr/pr app. Ist.aspx a 4/44016 Florida Bdldfg Code Ondine �, •."w'`il! ix'+µ e�� :xY ���_` iP �a��i;a � � �� " � �,�._.. , �� u``�°: F ., f%a' „ter ��'r x a� � p • Y1y,tl ' $1 s� r` FII 1 c' SCIS home Lop In user Registration Hot Topics submit surcharge j Stats a Fadon Facts ( Pubilratts ( Fac Staff sas site Map i,Links ( soarch BU nes Proessi I ' Product Approval USER:Pubbe User Regula 1 I Menu>bvdv&or Avolicytfon >Aooileatlon use>11ppUwthm OabN `£* x FL274?2 R1; ' Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived ! Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft. Myers,FL 33912 (800)432-2204 Ext 4314 thoard@)easternmetal.com Authorized Signature Timothy Hoard thoard@easternmetal.com Technical Representative Timothy 3. Hoard Address/Phone/Email 10030 Bavaria Road Fort Myers,FL 33913 (800)432-2204 Ext 4314 thoard@easternmetal.com Quality Assurance Representative Address/Phone/Email h Category.;,.. ;N!i+sdorvs.' Subcategory. hiulii0, (A: e Compliance Method Certification Mark or Usting Certification Agency Keystone Certifications,Inc. Validated By Keystone Certifications,Inc, f i Referenced Standard and Year(of Standard) Standard XAN j AAMA 450 2010 t TAS201 1994 TAS202 1994 TAS203 1994 1 Equivalence of Product Standards Certified By t� t C i Product Approval Method Method 1 option A hrirzc lftirsriri�taulrfins.ardcst/� am dtI-esox?oaram=wGEVXQWtDQtCUGoviQlz6AVC%2bOtoUJB%2fiWIPJ6hz%2Mg9Nf7cCfmsA%3d%3d i/2 4/1412016 , Florida Building Code Online _ Date Submitted 03/24/2015 t Date Validated 04/02/2015 Date Pending FBC Approval Date Approved 05/08/2015 Summary of Products FL# Model,Number or Name Description 17472.1 HVHZ Clipped Aluminum Bay/Bow HVHZ Clipped Aluminum Bay/Bow Mullion Mullion Limits of Use Certlfkstion Agency Certificate Approved for use In HVHZ:Yes FL17472 111 C CAC 622-104CAR.odf Approved for use outside HVHZ:Yes Quaity Assurance Contract Ekpiration Date Impact Resistant:Yes 09/22/2018 Design Pressure:N/A Installation Instructions other.See drawing set for mullion size,angle and design P117472 RX H PA-0004 HVHZ SS 2015-02-28.D9f pressure rating Verified By: Hermes F.Norero,P.E. 73778 Created by Independent Third Party: Yes Eventration Reports FLIZ472 RI AE PER3286 HVHZ SS 2015-02-28.odf Created by Independent Third Party: Yes f 37472 2 A HVHZ Cd d Aluminum�fiube ClippedAluminum Tube Mullion�Vi6Mdil HoNzontel ;T; PFe._ _ , Configurations z.a._ LJrrtitts of Usa - ICertifkatbn Ages."CertSieato Approved Mr apo in HVHZ Yes 4,, Ft.17472 Ri C=CAC 623 101CAR:odf Approved for use outsiYes Fl 17872 R1 C=CACk622-4b-kARtodf' Impset„ResislaM Yes �.. _ F117472 Ri CfCAC b22=103CAR.Ddf DeslgnPehedsuie5"N/A - -,' - J�17472 Ri GCAC 622-�05CAR.odf Other.See drawing set for mullion size, configuration and 17.17472 Ri C:CAC 622=1o6CAR:odf design pressure rating "' r ”: Qt�`ity'Asouriarica Contiact Expiration Date 07 18/2018 _. lis Inat8Matipiii InsIL 000 tnlctia;ns ` - Fi:17472-R1 PA- 3 HVHZ SS 2015-02-28.ndf Verified By 'Hermes F Rlorero;P E�73776-- F,J?x Created;#►y.Inifependent`Fhlyd Party:Yes EvAlation Reports ELN..2-R1 AE PER3285-HVHZ SS-2A1S=Q2=28.odf Created by IndependenE-Third-Party Yes�"` FEED Pi�zt Contact .:Ia4a North Monroe Street.Tallaha____FL 32- 9 Phone:BW407-1824 The State of Florida Is an WEED employer.Convnaht 2007-2013 State of Fhxlda.::Privacy Statement::AcxAg hility Statement::Refund Statement thrder Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send e4edron1c mail to tills entity.Instead,anted the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section. 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide We Department vrlth an email address If they Have one.The emalls provided may be used for official communication with the licensee.Howevei email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be mads avallable to the public.To determine If you are a licensee under Chapter 455,F.S.,please dick JIM. 1 Product Approval Accepts: srcurit'surittcs l r i 4 i G l I i ff1 k' f , I httpsJiflofidabuitdirtg.org/pr/pr_appdti.aspx?param=wGEVXQwtDgtCUGgvjQiz6AVC%2bDloUJ5%2fiWIPJ6hz%2iBg3hlf7cCfinsA%3d%3d 2!2 r Document e: ooc TilFRM,81.02' AL =7 Structural Performance Rev No: 7 PW: 1 or: 1 -)TTON& Certification .,O..>�. Authorization Report Required By: PRO 81-03 CAR & Product ID Number: 622 - 101.0 Issue Date: 1/16/2015 Revision Date: 4/1/2015 Expiration Date: 7/18/2018 Company Code: 622 This Certification Authorization Report(CAR)is issued by Keystone Certifications, Inc. (KCI)after full validation review, and is based on a standardized evaluation of the product conducted by an Independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, Including installation, condition of the wall/roof substrate and the age of the product and Installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels: Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified at www.keystonecorts.com. Licensee Information: Product Information: Eastern Architectural Systems Model-Name: 1"x3-1/8" Light Alum Mullion HN/T/X 10030 Bavaria Road Operator Type: Mull Fort Myers FL 33913 Configuration: No Reinforcement Max. Width: See Table Max. Height: See Table Referenced Standard: Product Rating: AAMA 450-10& PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings i i Qualifying 'fest Information: Test Report No: CTLA-3010W-4A/5A Test Report Expiration: 7/18/2018 Authorized Signature: Keystone Certifications, Inc. 1 564 Old York Road, Suite 5 Digitally signed by Steven M.Urich Etters, Pennsylvania 17319 DN:cn=steven M.urkh,o Keystone Phone: 717-932-8500 'Certiflwtions,Inc-ou, email=surlch@keystonecemxom,c=uS Fax:717-932-8501 Date:2015.04.01 1033A3-04'OD' i� it 141 W.KEYSTONECERTS.COM CAR No:622-101.0 Appendix . � .. Expiration Date:7/18/2018 Eastern Architectural Systems 10030 Bavaria Road Fort Myers,FL 33913 Load Tables for the: 1"x3.1/8"Ught Aluminum Mullion,Noriz/Vert/T/X DESIGN PRESSURE LIMITS FOR MULLION:I"x 3-1/8"(LIGHT)-ONE-WAY MULLIONS SPAN'L' TRIBUTARY WIDTH'W'(IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 2011.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 . 60 200.0 200.0 181.0 158.0 143.3 134.3 129.8 129.3 127.6 72 161.6 123.7 101.5 87.3 77.7 71.1 67.2 66.7 63.8 84 101.0 76.9 62.7 53.5 47.1 42.6 39.7 39.3 36.9 96 67.4 51.1 41.5 35.2 30.8 27.6 2S.6 25.2 23.5 108 47.2 1 35.7 28.9 24.4 1, 21.3 19.0 17.5 17.2 15.9 DESIGN PRESSURE LIMITS FOR MULLION:1"x 3-1/8"(LIGHT)-TWO-WAY MULLIONS SPAN 'L' TRIBUTARY WIDTH'W'(IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0, 36 200.0 200.0 200.0 200.0 191.4 167.5 151.3 148.9 134.0 48 200.0 200.0 200.0 167.5 143.6 125.6 113.5 111.7 100.5 60 200.0 200.0 160.8 134.0 114.9 100.5 90.8 89.3 80.4 72 157.6 118.2 94.5 78.8 67.5 59.1 53.4 52.5 47.3 84 99.2 1 74A 59.5 49.6 42.5 37.2 33.6 33.1, 29.8 96 66.5 49.9 39.9 33.2 28.5 24.9 22.5 22.2 19.9 108 46.7 35.0 28.0 1 23.3 20.0 17.5 15.8 1 15.6 14.0 Impact Ratings - t ASTM E1996-Wind Zone 4,Missile Level D i PA/TAS 2011203-Large Missile and Small Missile compliant Keystone Certifications,Inc. 564 Old York Road,Suite 5 Etters,PA 17319 Phone:717.932.8500 www.keystonecerts.tom i a Do rmntTitle: Ddc No: FRM:B9-02 Structural Performance Rev No: 7 pw: 1 or. 1 .,,.,c, nTONEi Certification Authorization Report__- . Required By: PRO B 1-03. CAR & Product ID Number: 622 - 103.0 Issue Date: 1/16/2015 Revision Date: 4/1/2015 Expiration Date: 7/18/2018 Company Code: 622 This Certification Authorization Report(CAR)is issued by Keystone Certifications, Inc.(KCI)after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels: Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified at www.keystonecerts.com. Licensee Information: Product Information: Eastern Architectural Systems Model Name: 1"x4"Aluminum Mullion HN/T/X 10030 Bavaria Road Operator Type: Mull Fort Myers FL 33913 Configuration: No Reinforcement Max. Width: See Table Max. Height: See Table Referenced Standard: Product Rating: AAMA 450-10& PA/TAS 201/202/203 See Appendix 1 Load Tables and impact Ratings Qualifying 'Pest Information: Test Report No: CTLA-3010W-8A/9A Test Report Expiration: 7/18/2018 Authorized Signature: Keystone Certifications, Inc. i Digitally signed by Steven M.Urich 564 Old York Road,Suite 5 DN:cn=Steven M.Urkh,o--Keystone Etters, Pennsylvania 17319 1 _ certtttcatlons,inc,ou, Phone: 717-932-8500 d `emalhsurich@keystonecerts com, Fax:717-932-8501 c=US Date:2015.04.01 11:02:39-WOO' i r 1 1%rW W.KEYSTONECERTS.COM �r l` F.Y `,a Appendix 1 CAR No:622-103.0 �R�.+..m�,.o+•.k Expiration Date:7/18/2018 Eastern Architectural Systems 10030 Bavaria Road Fort Myers,FL 33913 Load Tables for the: 1"x4"Aluminum Mullion,Horiz/Vert/T/X DESIGN PRESSURE LIMITS FOR MULLION:1"x 4"-ONE-WAY MULLIONS SPAN 'L' TRIBUTARY WIDTH'W'.(IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200..0 200.0 200.0 200.0 60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 72 200.0 200.0 200.0 181.5 161.6 147.9 139.7 138.6 132.6 84 200.0 159.9 130.4 111.2 98.0 88.5 82.5 81.7 76.7 96 140.1 106.3 86.3 73.2 64.1 57.4 53.1 52.5 48.8 108 98.1 74.2 60.1. 50.8 44.3 39.5 36.3 35.9 33.1 DESIGN PRESSURE LIMITS FOR MULLION: 1"x 4"-TWO-WAY MULLIONS SPAN 'L' TRIBUTARY WIDTH'W'(IN.) (IN.) 18 1 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 198.5 48 200.0 200.0 200.0 200.0 200.0 186.1 168.1 165.4 148.8 60 200.0 1 200.0 200.0 198.5 170.1 148.8 134.5 132.3 119.1 72 200.0 200.0 196.6 163.8 140.4 122.9 111.0 109.2 98.3 84 200.0 154.7 123.8 103.2 88.4 77.4 69.9 68.8 61.9 96 138.2 103.7 82.9 69.1 59.2 51.8 46.8 46.1 41.5 108 97.1 72.8 58.2 48.5 41.6 36.4 32.9 32.4 29.1 Impact Ratings ASTM E1996-Wind Zone 4,Missile Level D PA/TAS 201/203-Large Missile and Small Missile compliant {r Keystone Certifications,Inc. 564 Old York Road,Suite 5 Etters,PA 17319 ! Phone:717.932.8500 www.keystonecerts.com t ooeunent Title: Doc No: FRM 81-02' . Structural Performance R°"" ' P'go ' or. 1 iroj Ly S.M.N Certification Authorization Report Required By. PRO 81-03 CAR& Product ID Number: 622 - 105.0 Issue Date: 2/11/2015 Revision Date: 4/1/2015 Expiration Date: 7/18/2018 Company Code: 622 This Certification Authorization Report (CAR) Is issued by Keystone Certifications, Inc. (KCI) after full validation review, and Is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard.Actual fenestration product performance may vary used on many factors, Including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified at www.keysiDnewtscom. Licensee Information: Product Information: Eastern Architectural Systems Model:2"x4"Aluminum Mullion HN/T/X 10030 Bavaria Road Operator Type: Mull Fort Myers FL 33913 Config: No Reinforcement Max Width: See Table Max Height: See Table i Referenced Standard: Product Rating: AAMA 450-10& PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings Qualifying Test Information: Test Report No: CTLA-3010W-8A/9A r Test Report Expiration: 7/18/2018 Authorized Signature: 1 Digitally signed by Steven M.Urich Keystone Certifications' Inc. Did:cn=Steven M.Urich,o=Keystone 564 Old York Road, Suite 5 5 Certifications,Inc,ou, Etters, Pennsylvania 17319 email=surich@keystonecerts.com, Phone: 717-932-8500 c=US Date:2015.04.0111:06:34-04'00' Fax: 717-932-8501 { W W W.KEYSTONECERTS.COM u a o Appendix x 1TCAR No:6U.105.0 Expiration Date:7/18/2018 Eastern Architectural Systems 10030 Bavaria Road Fort Myers,FL 33913 Load Tables for the: 2"0'Aluminum Mullion,Horiz/Vert/T/X DESIGN PRESSURE LIMITS FOR MULLION:2"x 4"-ONE-WAY MULLIONS SPAN 'L' TRIBUTARY WIDTH'W'(IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.6 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 200.0 200.6 200.0 200.0 200.0 200.0 72 200.0 200.0 200.0 200.0 200.0 197.0 188.0 186.8 180.1 84 200.0 200.0 195.1 166.4 146.6 132.5 123.5 122.2 114.8 96 200.0 159.0 129.1 109.5 95.9 85.9 79.5 78.5 73.0 108 146.7 111.1 89.9 76.0 66.2 59.1 54.4 53.7 49.5 DESIGN PRESSURE LIMITS FOR MULLION:2"x 4"-TWO-WAY MULLIONS SPAN 'L' TRIBUTARY WIDTH'W'(IN.) (1N.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 197.0 178.0 175.1 157.6 60 200.0 200.0 200.0 200.0 180.1 157.6 142.4 140.1 126.1 72 200.0 200.0 200.0 175.1 150.1 131.3 118.7 116.7 105.1 84 200.0 200.0 180.1 150.1 128.7 112.6 101.7 100.1 90.1 96 200.0 155.1 124.1 103.4 88.6 77.6 70.1 68.9 62.0 108 145.2 108.9 87.1 72.6 1 62.2 54.5 49.2 48.4 43.6 Impact Ratings I ASTM E1996-Wind Zone 4,Missile Level D PA/TAS 201/203-Large Missile and Small Missile compliant Keystone Certifications,Inc. 564 Old York Road,Suite 5 Etters,PA 17319 Phone:717.932.8500 !` www.keystonecerts.com : �` d Docuneot 7ft: Qac No: FRM 10111-021 Performance Rev No: 7 Pa9m 1 1 ,�YS'TON Certification cel Authorization Report Required By: PRO 81-03 CAR& Product ID Number: 622 - 106.0 Issue Date: 2/11/2015 Revision Date: 4/1/2015 Expiration Date: 7/18/2018 Company Code: 622 This Cerfi ication Authorization Report(CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an Independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, Including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates In affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall .be considered certified. The information in this report can be verged at www.keys$Dnecerts.com. Licensee Information: Product Information: Eastern Architectural Systems Model:2"x6"Aluminum Mullion HN/T/X 10030 Bavaria Road Operator Type: Mull Fort Myers FL 33913 Config: No Reinforcement Max Width: See Table l Max Height: See Table Referenced Standard: Product Rating: HAMA 450-10& PAITAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings Qualifying Test Information: Test Report No: CTLA-3010W-8A/9A t Test Report Expiration: 7/18/2018 Authorized Signature: ti Digitally signed by Steven M.Urich Keystone Certifications, Inc. t DN:cn=Steven M.Urich,o=Keystone 564 Old York Road, Suite 5 0 4. Certifications,Inc,ou, Etters, Pennsylvania 17319 email=surich@keystonecerts.com, phone: 717-9-32-8600 c=US Date:2015.04.01 11:26:48-04'00' Fax: 717-932-8501 ll. WW W.KEYSTONECERTS.COM "r i ,�1VST9/I i Appendix Z CAR No:622-106.0 Expiration Date:7/18/2018 Eastern Architectural Systems 10030 Bavaria Road Fort Myers,FL 33913 Load Tables for the: 2"x6"Aluminum Mullion,Horiz/Vert/T/X DESIGN PRESSURE LIMITS FOR MULLION:2"x V'-ONE-WAY MULLIONS SPAN'L' TRIBUTARY WIDTH'W'(IN.) (IN,) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200:0 200.0 1 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 72 200.0 200.0 200.0 200.0 200.0 197.0 188.0 186.8 180.1 84 200.0 260.0 200.0 191.0 171.5 157.6 148.7 147.5 140.1 96 200.0 200.0 186.8 161.6 144.1. 1 131.3 123.0 121.8 114.6 108 200.0 197.0 162.7 140.1 124.2 1 112.6 104.9 103.8 97.0 DESIGN PRESSURE LIMITS FOR MULLION:2"x 6"-TWO-WAY MULLIONS SPAN 'L' TRIBUTARY WIDTH'W'(IN.) (IN.) 18 1 24 1 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 197.0 178.0 175.1 157.6 60 200.0 20D.0 200.0 200.0 180.1 157.6 142.4 140.1 126.1 72 200.0 200.0 200.0 175.1 150.1 131.3 118.7 116.7 105.1 84 200.0 200.0 180.1 150.1 128.7 112.6 101.7 100.1 90.1 96 200.0 197.0 157.6 131.3 112.6 98.5 89.0 87.6 78.8 108 200.0 175.1 140.1 116.7 1 160.1 87.6 79.1 77.8 70.0 s Impact Ratings `r ASTM E1996-Wind Zone 4,Missile Level D PA/TAS 201/203-Large Missile and Small Missile compliant i Is � D Keystone Certifications,Inc. 564 Old York Road,Suite 5 Etters,PA 17319 Phone:717.932.8500 ' www.keystonecerts.com s EASTERN ARCHITECTURAL SYSTEMS HVHZ CLIPPED ALUMINUM TUBE MULLIONS _ GENERALNDTES: Wl`. '4V2' ;'.{�•Wl•�•VVZ•+-�"- . 1 THE PRODUCTSHOWNHEREIN ISDESIGNEDANDMANUFACTUREDTOCOMPLYWTN'THE2010&SthE0Ti0N 4 FLORIDA BUILDING CODE,INCLUDING THE HIGH VELOCITY HURRICANE ZONE. MULL 3. APPROVED.tMPAtTPROTECTiVESYSTEM ISNOTRfQUIREDFOR THLSPRODUCT INWINDBORNE DEBRIS REGIONS. 4 INDMDUALUNITSATTCHEDTOMULLION I �IMPACTRATED. `\� SQ'AN•I _�`� 4, ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRYAND 2X FRAMING ASA MAIN WIND FORCE RESISTINGSYSTEM CAPABLE OF WITHSTANDING ANDTRAIMERRING APPLIED PRODUCT LOADSTOTHE FOUNDATION is THE RESPON519MWOfTHE ENGINEER ORARCHITECT OfRECORD FORTHEPROIECTOF INSTALLATION. S. 1X AND ZX BUCKS(WHEN USED)SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADSTO THE VE47TCAL MILU STRUCTURE.BUCK DESIGN ANDINSTALLATTON ISM RESPONSIBIUTYOFTHE ENGINEER OR ARCKITECTOF RECORDE SPAN`L.• �SMULL L� FOR THE PROJECT OF INSTALLATION. 4 6. THEINSTALLATIONDETAILS DESCRIBED HEREIN ARE GENERICANDMAY NOTREFLECTACTUAL CONDTIONSFOR A TIM. OM SPEGfECSTTE.If SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQtRREMENTSOETAiLEDHERE{N, M � Q � A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPEGTC DOCUMENTS MR USE WITH THIS DOCUMENT IN NON-HVNZ AREAS.IN HVNZAREAS.ONE TIME PRODUCT APPROVAL TO BE OBTAINED FROM MIAMN)ADE PERJL 7. MULLION&CLIP MATERIAL:ALUMINUM WOS-TS&606346(AS NOTED) IL MULLIONS MAY BE USED WITH ANY APPROVED FENESTTIATION PRODUCT,UNDER SEPARATE APPROVAL ,y(, y1F Wl. 9. SEE SHEETS S-9 FOR INSTALLATION ANCHOR REQUIREMENTS FOR SPECIFIC ANCHORING REQUIREMENTS,MULLION CONFIGURATIONS,AND DESIGN LOAD CAPACITIES. AN04GR aV. A 10. IN ACCORDANCE WITH THE 2010&STH EDMON FDC,DISSIMILAR METALS INCLUDING FASTENERS THAT MAY COME TYP 4 1noCONTACFWTHALUMINUMUNITFRAMINGSHALLBEPROTECTEDASDEFINEDINSEC2003.RA. TYPICAL HORIZONTAL" F'MULLSPAN MULL ^— "TRUCUMS. 1. DETERMINE REQUIRED DESIGN PRESSURE FOR OPENING. ) L CHOOSE AMULLION THAT PROPERLY FFMT14EFENE5TRATNINPRODUCT. `W2` TABLE OF CONTENTS 3. DETERMINEWHETHERASSEMBLY REQUIRES ONEWAYOlt TWO-WAY MUUTONS. } . ASSEMBLIES CONSISTING OF STACKED Olt SW.SY,STDEUNTSREQUIREUSE OF SHEET REVISION SHEETbESCWTION ONE-WAY MULLIONS. . ASSEMBLIES CONSISTING OFMUVWUEUNITS MUUEDTOGETHERWTH 1 - GENERAL NOTES,INSTRUCTIONS.ANDELEVATfONS MULTIPLE MULLIONS REQUIRE USE OFTWO-WAY MULLIONS. SEE SHEET Il FOR'ASSEMMY ANO WAO MI AMPLES. 2 - MUUSONDETATLS . IFASSEMMYTYPECIINfNOFBEDLTERMIN0USETWO-WAYMUWONCHART. a. vEQIFY r'18 ANC14MO-TPDETAMS PRFSSUREOFOPENINGUSINGCHAIMONSHEEI3"0.' - MULLION SECTIONS S. QUALIFIED"TYPESAPPEARONSHEETS6d0.MUMPLEANCHOR WKISUBSiR WJMPODMSMA tOMWMfDUANOPEWWAREALLOWEDTYPICAL MULLION&CL PASSEMBLIES & THE LESSER DESIGN PRESSURE OR MULLION Olt FENESTRATION PRODUCT WILL HORIZONTALSF N 1'X 3-11V grMTy MULLION DEsing"LOAD TABLES GOVERN OVERAILASSEMBLYDFSIGN PRESSURE RATtNG. - 1'X 3-1/6"(MEAN!)MULLION DESIGN LOAD TABLES - 1•X 4'MULLION DEMON LOAD TABLES t�ttttELittFtjP� RE'iTRRIQAlB �„ ustER+n v lrafne� 9 Y X 4•MULLION bES16N LOAb TABLES \��(Orj IF �I� EaSterjt ffAMMEar u�MV SO - Z'X 6'MULLION OESI6N LOAD TABLES 4-� f! - MULLION ASSEMBLY AND LOAD EXAMPLES ; - * ALPPED RZTSNGW�MCAND HORIZONTAL,CORURAR JAS"13 TJ)i Norero,MDigitally signed by Hermes F. Reason:I am approving this document �''�,- S�'"""'"�����;•`� °"+�°'I>a` Fr� YeQ PA-0003 MT.S. 2 attlflO�AYLGfit♦b.t73!{ Date:2015.02,2812:010-05'00' 1 F ^M P t ' t --{ f-- 1.000 x.ow H»- --� 1 0.230° 0.2w 6.000" 0.125 0.125F 4,006' 4.000' 3.123' 3,12"5° i I 0.373° 0.625' 0.250' 0.230' 0.236' 1"X 3-llr(UGH'1`) 1"X 3-1/8"(HEAVY) Me e r X e r X fi MULLION MULLION MULLION MULLION MULLION SEE SHEET 6 FOR SEE SHEET 7 FOR SEE SHEET 8 FOR SEE SHEET 9 FOR SEE SHEET IO FOR QUALIFIED CLIPS QUALI'F 4CLIPS QUALumb aysQUA tZ D Q IPS QUA TMD CIPS NOTE:SEE SHEET 3 FOR SPECIFIC QIP TYPES ANO bU*NSI x1�$F J 1 eOY�,i,'i ti+,�~� •"' .•A.�O�I� YS; AWMINAw a~OM�~AEVKM~�� amllb0a HVHZ CUPPED ALUMINUM TUBE MULLIONS VERTICAL AND HORIZONTAL CONFIGURATIONS "ri .'1• *r`� �� 02/0 13� TJH waonrews n+c •��, "!•...:••- (3�.,..�. wawsoue; wse nrea+rmwaar PA-0-003 NT.S amuunawrea�ste w we msoonw 1-1-2 OF 11. av ;r Q2. 22 —0 0 ^/tL 7r 2. 3.373° 425° 0 2.28° o 4,625• 5,375' 0.1 0.125' 2° 11 0.129' _1j� 0 0 2,25• 2"X 5"X 21/4" L-CUP 2"`X 3"X 1314" t-CLIP a.:25• �2�• 2"X 4"X 3 3/8W' L-CLIP ALUMINUM 6063-T6 ALVMIt3UM 9063 T ` ALUMINUM 6063-T6 2"X 4"X s 3/8" L-CLIP 10.46" ALUMINUM 6063-T6 2.50° A 0.722'--i 1.- 2.25• O o 2,25" o -T 0.722'-,--q i— 10.44V 2.25' 0 2.25• L76• 0 2.25. 0 0 2,25° 1 1 a i 2,33'. 2 25° _L oO —L _ .L a K-271. 0,188• 1,25° ! 0 25• 0 a - Jlf� H-T H-T11 o.1ar 1015/32"X 21/4!'H-CUP 1.25" 1 ALUMINUM 6063 T6 21/4" U-CLIP 13/4" U-CLIP ALUMINUM 600-T5 ALu 005 M 6 -T5 1015/32"X 13/4!' H-CLIP ALUMINUM 6063-T6 8.25• 2,25° 2,25° 2,25° 0 0 0 0 2.625 ��rr ,``�"{{1""t7ttt��' RE1ft8"ON3 .iNSMOrn awampns"aftMsicfa 0 0 0 0 ♦����rGS K O ptt ,m"vnnme ``t)¢++++••s • * �,✓ti ,�o-N A� �. HCIIOI131l1! 0.125' ±�Yi' -O HMZ CLIPPED ALUMINUM TUBE MULLIONS 0.875° �� *• :t*r VERTICAL AND HORIZONTAL CONFIGURATIONS ill to 81/4"X 3 3/8"" H-CLIP o ''•; �.i�w 02 05 t3°'� T 14 ALUMINUM 6063-T6 it, '+••; \ �� O1� 101° '0MS °"" ARO° A-0003 N T.S. Iii amact� arro assn n oaa oirwarrtw ""'r 3r OF7' st INSTALLATION INSTALLATION INSTALLATION ANCHOR(SEE NOTES 211x•MIN. ANCHOR(SEE -S7 3 3/2•MIN. ANCHOR(SEE'NOTES HORIZONTAL SHEETS 6-20) EDGE DIST. SHEETS 6-10) EMBEbMENT SHEETS 6-10) Mme' ' CONCRETE OR ` • MASONRY BY OTHERS '� • ♦. s'- CAULK BETWEEN a d e 2 iJ4'MIN 314'MIN. f EXTERIOR MULLION CLIP CONCRETE/MASONRY b IX ° Q. • .� EMBEDMENT EDGE DIST. i; TYP. WOOD BUCK BY OTHERS _ _ __ 'U'0.2P TYP. 1 X WOOD BUCK CONCRETE OR EXTERIOR INTERIOR tr' BY OTHERS MASONRY BY OTHERS CAULK BETWEEN ,t VERTICAL_ 1 I MULLION CLIP CONCRETE/MASONRY A 2X TYP. WOOD BUCK BY OTHERS + MULLION,TYP. I I . q. - 1 i I 1 z X WOOD BUCK EXTERIOR I 1 INTERIOR BY OTHERS - +. . I _ INTERIOR _ TripON ORIZONTAL SECTION I I SMYUP�ON T•MUIItONIN1EliSECiDETAI HORIZONTAL SECTION smvm'" C g VERTICAL SECTION JAMB-n B►« w SIDE VtEW4RWJZONTRL H NERD-tOt3GtESEjMASONRY SIDEV1EW VEIMCAL INSTALLATION 1 i ANCHOR(SEE NOTES SHEETS 6-14j HORIZONTAL MULLION,TYP. EXTERIOR i I INTERIOR I ",—MuWON NOTE PRIOR INTERIOR I { TYP. ® TMYA�ON CLIP DETAILS SHOWN ARE TYPICAL FOR 1 1 ALL MULLION A CLIP A IN S. VERTICAL I ISEE SHEETS 6-10 FOR ALLOWABLE MUL XON,TYP. 1 MULLION CONFIGURATIONS,SIZES, I ( MULLION CLIP AND DESIGN PRESSURES. i I TYP' ORIZONTAL SECTION •. v' �� X*#UWO%""0SECIDETAIL ° c MEV1EW e 13/4"MIN. d, EMBEDMENT PRECAST SILL a - ti11{lfl/ftt tr WASKIM uemw.nwnmuRaeronxee BY OTHERS %110' ' NOW= QN � •~ • ,''moi INSTALLATIONL Q. .•�. pQ��„ ANCHOR(SEE NOTES 21/2°MIN. .� ? – rVWERnCAI-HZ CUPPED ALUL41HUM TUBE MULLIONS SHEETS 6-10) EDGE DISTANCE =* slr p AND HORIZONTAL CONFIGURATIONS A VERTICAL SECTION ..=�; Dom: a . ,a SIL-COPICRETT/NIam" �'. ;g: • ,' ,Q im J «�a�rseaosa¢ SiDEVIEWVER1TtAL 'ice aweftle G� N T ,uuTIMAEo aarne at lie oaiT pr , f VERTICAL MULLION U—CLIP TO MULLION CONNECTION HORIZONTAL MULLION "—CUP SUBSTRATE BY OTHERS SUBSTRATE VARIES, SEE NOTES SHEETS 6 — 10 H--CUP ANCHORS ALL INSTALLATION HOLES MUST HAVE AN ANCHOR INSTALLED IN THEM MULLHON AND CLIP ASSEMBLY TYPICAL ASSEMBLY SHOWN WFM I-x 311V MULLION AND H CLIP.OTM MULLIONS AND CLIPS ARE APPROVED. SEE INDIVIDUAL MULLION SHEETS F r►tOrr�',4 REvIstBtaseaenmmFAm,M° an+nes ,i/!►. ~ '� /�LYMIMUMYYONMbL +`�.•r~••• ��� ,II ...Va;.`1v..,.......,nw.i......e,+� rmy. asararn �'• • O HVHZ CLIPPED ALUMINUM TUB£ MULLIONS VERTICAL.AND HORIZONTAL CONFIGURATIONS A°• , um n: C!'' O O 13 TJH + wmenrab+a.n+c ��. l,t... ,.•�U`.,� awumwae taus aca�taruiem ��`•,` 14� PA-0003 N,T.S. ++ mo�stao:fare "` 5 OF 11 �v I � .l R LOWOFSIGNPRESS1RtEUMF7SFORMSA210N:1'%3 t!G -ONE-WAYMtA1SONS MUL1SON MULLION SPAN TMBUFARYWWN VW IN. R (IN3 is 24 39 35 f2 1 4E 1511251 34 1 W 24 2Mo 200.0 200.0 2000 200.0 I 200.0 F 2M0 I 2WA I 2000 36 200a 20x0 2WO 2000 2M0 2000. 2000 1 2WO I 2000 1 012V 48 2000 2ndo 2W.0 2000 2WO 2000 2000 2000 2000 3425' W 2008 2W.0 1810 L'iB.0 1433 1343 129.E 1293 127.6 72 16LS 123.7 1015 873 77.7 713 61.2 GO- 53.E 84 1010 76.9 67.7 S33 47.1 4E6 39.7 393 369 N 67.4 1 S1.1 I 4L$ 352 30.11 7.7.6 206 252 205 ONE--WAY MULLION DIAGRAMS 109 47.2 35.7 las 24.4 21.3 19.0 17.5 1 17.2 15.9 0375' OFSIGNPRMStRiEUWMFORAfiMON:1%3118`U -TW"AYMUUIONS 1"X 3-1./8"(LIGHT)MULLION SPAN w TMOMARYWIO1NW Ea. ALUM2NUM600!5-IS MULLION- 1N. ie 2d 1 30 1 36 t 42 48 153.325 54 W MULLION 24 2W.0 2000 1 2000 I 200.0 2000 2=0 1 2000 2000 200.0 36 2000 2000 200.0 2000 39L4 167.5 7SL3 24E9 1310 48 2000' 200.0 2000 1675 143.6 125.6 113.S 11L7 1005 W 2000 2W.0 1606 1340 114.9 MS 908 693 804 • T2 157fi 118.2 94S 7aE 67S S9.1 53.4 523 473 TRIBUTARYWIDTH= Wl-W2 84 99.2 71.4 99.5 49.6 42S 37.2 33.6 33.1 29.8 2 46 66S 49.9 349 33.2 2&S 24.9 22.5 2Z2 1 19.9 M 106 16.7 35.0 7E.0 230 20.0 17S 15.8 75.6 14.0 TWO-WAY MULLION DIAGRAMS TABLE NOTES: L SEE SHEET 1 F{E217NSTRUCTIONS ON USING TABLES.SEE SHEETS 4 AND 5 FOR TYPICAL INSTALLATION METHODS 6 OW DETAILS. _ 2. LINEAR INTERPOLATION BETWEEN L2STED WIITHS AM SPANS 15 ALLOWED. QUALIFIED ANCHOR CLIPS a. SSEESHEET3� CIF FOR"bZMENSIONS. 5. ANCHOR REQIFIREMEM- •WOOD:#14 WOOb SCREWS •CMU:V*r7W TAPCONS .CONCRETE:1/4•ITW TAPCONS METAL 2/4'SELF•DRI.LIN6 SCxtEWS(GRADE 5) ° 6. INSTALLATION SUBS MAT o a 0 0 •Wf?OD"ANC 4ORS SHALL HAVE A MIN.EMSEDMEI4T OF Wre b Eb6E DISTANCE OF i°.WOOD SHALL SE MIN S.B. 55. 0 rF1OLLOW CMU'ANQiORS SHALLHAVE A Mm EMBEDMENT OF 2-U4.6 EDGE DISTANCE OF 2-112':HOLLOW CMU SHALL 2"X s"X 1/4" L CLIP v! COPIFORMINB TO ASTM C90. CO4NCRETE ANCHORS SFIALL'HAVE A MIN.EMBEDMENT OF I-3/4 Q EDGE WSTANWE OF 2-1/2":COW METE SHALL BE 21/4°U�CLIP M,�y--�--- ALUMINUM 6063-T6 •METAL ANCHORS SHALL HAVE A WK(3)THREADS PENETRATION 8EVOND METAL STWCTURE STEM SHALL BE MTU ALUMINUM 6005-T8 *•MUST BE USED IN PAW is GA:(0.045'TH=33 KSIYIELD.ALUMINUM SHALL BE MIN.VW THICK ALUMINUM 6063•T3. U-amp FOR USE ONLY IN MULLICN-TO-MULLION CONNECTIONS 11 t, rfrt h veeracnwnsr%aees 0 0 0 ���%% 4f4C F• O'00 MATE:SEE SHEET 3 FOR SPECIFIC o a 0 i !6OF HZ CUPPED ALUI:UNUM TUBE MULLIONS G11P TYPES AND DIMENSIONS. RTICAL.•AND HORIZONTAL CONFIGURATIONS LUION 1015/32"X 21/4" H-CUP ALUMI�R3M 6063-T6' •�� y''.. rr ice. WWM "sem ■er11 MULLI w OEM PRFSSUREUMnf0R :Px3 ONEWAYMUAUO9s SPAN V TRI RY w IN. SE Q4 30 39 42 4E 53.225 S4 W 24 X0,0 200.0 200.0 I 20D0 •2000 2000 1 700.0 200.0 200.0 36 7000 200.0 200.0 1 200,0 1 2000 2019 2000 2000 700A 48 202.0 2000 2000 200A I 2000 2000 200.0 2000 0125° W 200.0 2000 200.0 191.4 1767 167.5 162.2 16L6 LS9.4 72 2000 1S4S 129.E 1011KO I U3 1 74J 1 3125 84 1262 961 7a4 G&S Sag 53 2 49.6 491 461 96 84.2 639 SLE 44.0 345 3L9 .3L5 z43 ONE-WAY MULLION DIAGRAMS Ml 1 59.9 1 44,6 1 361 766 I 23.7 1,2LB LUS I 19.9 OECIGNPMSUREUMMFD;tMMON:1'x3 1C NEA -TWO-WAYMUWON5 1 0.623" a SPAN TRUWARYWIb2HW IN. 1"X 1/$"(HEAVY)M LION MUH;LION IN. is 24 30 36 42 48 53.125 54 W ALUMINUM VY MUUSON - 24 MD.0 2000 2x1.0 2000 2000 2000 200.0 2MO 2000 38 200.0 2000 2000 200.0 19L4 1675 L5L3 14$9 I 1310 48 200.0 2000 2000 1675 243.6 U&S 2735 11L7 I100.5 w 2000 200.0 IW.E 134.0 114.9 1005 4 72 196E 147.8 116.1 95.4 84,4 73.8 667 85.6 59.i - 94 IM,O '93.0 74.4 620 sm. MS 420 4L3 37.2 TRIBUTARY WIDTH= ���- 81.0 623 44,E 41S 35.6 3L2 X1, 27.7 24.9 108 Sa3 43.7 35.0 29.2 75.0 21-9 19.E MA 17.5 TWO-WAY MULLION DIAGRAMS TABLE NOTES: L SEE SHEET I FCR MSTRUCT=,tS ON USING TABLES.SEE SHEETS 4 AND 5 FOR TYPICAL INSTALLATION METli0b5 6 CLIP DETAILS. z. LINEAR INTERPOLATION BETWEEN LISTWb WIbT ks AND SPANS IS ALLCWEb 3. SEE THIS SHEET FOR SPECIFIC MUUSON DIMENSIONS. QUALIFIED ANCHOR CUPS 4. SEE SHEET 3 FM SPECIFIC aV tPIMENSIONS. 5. ANCHOR REgUD1EMENTS: WOOD:024 W0015 SCREWS �^ \ •CMU:V4*ITW TAPCONS O 8m o • .1/4"SE"LF-DAI LING SCREWS(GRADE 5) 3/4"U-CUP o 4 6. INSTAMETTAILLATION SUBSTTRATES: •W00b ANCHM SHALL HAVE A MDL EMBEDMENT OF 1-1/2'8 EDGE DISTANCE OF P-W00b SHALL BE MIN.S.G.t0.55. ALUMINUM 6005-T5 •HOLLOW CMU ANCHORS SHALL HAVE A MIN:EMBEDMENT OF 1-1/4'6 EDGE DISTANCE OF 2-t/2'.HOLLOW CMU SHALL 0 0 0 0 IUM WEISHT 6*11FORMING TO ASTM C 90. U-CLIP FOR USE ONLY IN •COALCRETE ANCHORS SHALL HAVE A MIN:EMBEDMENT OF 1-3/4'.6 EDBE DISTANCE OF&I/Y..CONLRETE SHALL BE MULLION-To-MULuoN 2"X S"X 13/4"L-CUP ►�=-` CONNECTIONS ALUMINUM -T6 •METAL ANCHORS SHALL HAVE A MIN.(3)THREADS PENETRATION BEYOND METAL STRUCTURE.STEEL S14ALL'BE MIN, "MUST BE USED IN P i8 6A. )45THICK)33 KSI YIELD.ALUMINUM SHALL BE MIN.VB"THICK ALUMINUM 6063-T5_S F astern. 1, q'�a••• • � r/ .\4�MIMYM.�M YIM7�. 5� �p 0 0 o ti�Qi•�.•• •..�0!�� a,.`-r.+�'". -...�.....£:..»... , weAomasu NOTE:SEE SHEET 3 FOR SPECIFIC t HVHZ CUPPED ALUMINUM 'TUBE.MUUJONS CLIP TYPES ANb DIMENSIONS. o 0 0 - VERTICAL�AND.H01100147AL CONFIGURATIONS 10 16/32".X 13/4"3/4!'H-CLIP . ''�'`• ALUMINUM 6063-T6 ���i�O •'•••••»••~��� �'1`' auv8wiora T3T:IHNy�yA �♦ Ph- I S. 4M amt mxn: ad: OF III ... 1? MIRLION DESIGN PRESSUREUKUFORMULUON:YM4°-ONE•MvAYMU1LON5 1.000° MULLION SPANl 'nUMNARYYwmmHRld'IN. IN. U 24 30 1 36 1 42 46 SIM I S4 W 24 210.0 I 20.0 I 240 2040 1 200:0 200.0 200.0 I 2040 20.0 36 200.0 1 200.0 2MO 200.0 I 200.0 2X10 20.0 200.0 240.0 0 . 4" 2000 2X10 21110 2X10 2000 2000 210.0 2040 20J) w 2X10 2040 20.0 200.0 2040 200.0 200.0 20110 mo 72 X140 200.0 2X10 18LS 16LG 147.9 139.7 MG 1326 4,000' + � 84 20110 259.4 230.4 11L2 9R0 E1.S "258LT 7.T 96 1401 1043 8.3 73z "1 5714 $3.1 s2s 41a ONE-WAY MULLION DIAGRAMS log SRI 74.2 �2 506 4lA3 395 3.3 359 33.t mIGNPRFSSUAEUw%FORMi111JON:1=4'-1WO WAYMW10N5 Rg, TRI"UfAMWiOTNYY IN. 0250' { MULLIOPI MULLION i" 24 30 36 42 43 S312S 541"X 4" MULLIQN 2140 =0 2X10 270.0 2X10 2 O 2040 2010 2X1.20.0 2140 2100 2X10 2X10 27110 20A0 200.0 =5 ALUMINUM 6005-TS=0 210.0 2010 jJM:t2l8Wk4 166.1 SERI 1614 144 210.0 20110 2100 146E 1345 1323 129.1 210.0 2100 19.6 122.9 1110 10.2 9R3 20.0 154.7 123.E 77.4 639 GR" GL4 TRIBUTARY WIDTH cWZ 1382 103.7 82.9 5L" 4.8 4.2 4LS 97.1 728 58.2 4R3GA 319 324 29.1 TWO-WAY MULLION DIAGRAMS TABLE NOTES: L SEE SHEET 1 FOR INSTRUCTIONS ON USSNS TABLES.SEE SHEETS 4 AND 5 FOR TYPICAL INSTALLATION METHODS A CLIP DETAILS. 2. LINEAR INTERPOLATION BETWEEN LISTED WIDTHS AND SPANS IS ALLOWED. 3. SEE THIS SHEET FOR SPECIFIC MULLION DIMENSIONS, 4, SEE SHEET 3 FOR SPECIFIC"DIMENSIONS. S. ANCHOR REQUIREMENTS: •WOOb:#14 WOOD SCREWS -CMU;1/4ITW TAPCONS QUALIFIED ANCHOR CLIPS •CONCRETE-IX ITW TAPCONS •METAU V r SELF-bAlUMV SCREWS(GRADE M 6. INSTALLATION SUBSTRATES: -WOOD ANCHORS SHALL HAVE A MIN,EMBEDMENT OF 1.1/2'b EDGE bISTANM OF 1',WOOD SHALL BE AWL S.6.N2.ai5. +HMLAW CMU AAa4OR5 SHALL HAVE A MIN.EMBEDMENTOF 1-1/4'A 9W OMANCE OF 2-112'.HOLLOW CMU SHALL 0 0 o 0 o 0 0 0M riTcoWTO ASTM C 90. •CONMETE ANCHORS SHALL HAVE A MIN:EMBEDMENT OF 1-514•A EDGE 6ISTANGE OF 2-112':CM40M SHALL$E MIN.4OW PSL +METAL ANCHORS SHALL HAVE A MIN.(3)THREADS P94E'iR UM BEYOND METAL STRUCTURE.STEEL SHALL BE MIN. 045•THICK)33 KSI YIELD.ALUMINUM SHALL BE MIN,I/$'THICK ALUMIPIUM'60M-75. 0 0 0 0 O O O 111t1lttittl 0i1:1J O �p�•'l�s �'',. :ss.: ' +�$ l`/� 2"X 4"X 3 3/8" L-CLIP F • 81/4 X 3 3/8 H-CLIP ALUMINUM I � .. I wj "MUST BE USED IN PAIRS Cld•SI� ALUMINUM 3 Z r HVHZ CLIPPED 'ALUMINUM TUBE MULLIONS VERTICAL AND HORIZONTAL CONFIGURATIONS 1* v r MULLION NO SEE SHEETS FOR SPECIFIC 'i CW-TYPES AND bTMENSION5. 'I,i�` `'•.:»..••' G����� wuwowc aeuc 7a� 1R� � �� PA- N T.S. :! t` um+auramsiao�.eoln ;qo- 'Ste ra4r: aev, w eae -�wonau ""' OF 11. s{ MION PRESSMI UM M FOR MUWON:2•x 4•-ONE•WAY NW WOMS _t MULLION VAN'G TRBOTARYWi11HW 08. -+f 2Aow IN. 19 1 24 1 30 1 16 1 42 1 48 51.125 I St 6O 1 MULL I'ON 24 2000 2000 2000 2000 200.0 7000 200.0 200:0 2040 36 "200.0' 2000 1 200.0 1 2MO 1 200.0 2000 7000 1 2000 2000 48 2000 2000 200.0 2000 7040 ZONA 2000 2000 200.0 60 200.0 2000 20D.0 2040 2000 200.0 20D.D 2000 200.0 0.256° n 2000 2000 200.0 2000 2040 1470 1050 I%$ 140.1 M 2000 200.0 195.1 1664 1466 1425 I23.S 1722 114E 400 , « 96 m0.0 159.0 179.1 109.5 95,9 a59 79.s ns 73.0 109 146T 11L1 449 76o ou 59.1 SC4 51T as ONE-WAY'MULLION DIAGRAMS OE516N PREsSUREUMtfs FOR MUWON:2•x P-1W W WAYMUWONS SPAN V 1R19tlfARY WIOlt17Y IN. IN. 18 24' 30 36 42 4E S3.375 54 w MULLI 24 2000 2000 207.0 2000 2000 M" 1040 2040 2000 0.250° MULLI 36 200.0 2000 =0 2000 2MO 2000 2040 7.0 =0 2"X 4"MULLION 4a woo mo 204o moa moo 11,0 17ao i75.1 .1526 60 moo moo 2040 =0 1401 167.6 1424 140.1 126.1 ALUMINUM U05-T5 n m0.0 moo 2000 1751 1541 =3 1167 1167 105.1 94 =0 2000 MI 1901 UV 117.6 MT 100.1 %I 9620D.0 ISM 124.1 1014 966 77.6 M 64.9 62.0 y/1.W2 109 145.2 10&9 97.1 72.6 ELI 51$ 49.Z 464 43,6 TRIBUTARY WID`IH= 2 . TWO-WAY MULLION DIAGRAMS TABLE NOTES: L SEE SHEET 1 FOR INSTRUCTIONS ON USING TABLES.SEE SHEETS 4 AND 5 FOR TYPICAL INSTALLATION METHODS 6 CLIP DETAILS. 2. LINEAR INTERPOLATION BETWEEN LISTED WIDTHS AND SPANS IS ALLOWED. 3. SEE THIS SHEET FOR SPECIFIC MULLION DIMENSIONS. 4. SEE SHEET 3 FOR SPECIFIC CLIP bIMENSIONS. 5. ANCHOR REQUIREMENTS QUALIFIED ANCHOR CLIPS •WOOD:#14 Wood ONS .CMU:1/,VzTw TAPCONs •CONCRETE.3/4rTW TAPCONS •METAL 1/4•SELF-bRnUM SCREWS(GRADE 5) 6. INSTALLATION SUBSTRATES: 0 0 0 0 •WOOD'ANCHORS MALL HAVE A MIN,'EMSEDMENT OF 1-1/2•b EDGE DISTANCE OF P.WOOD SHALL BE MIN.S GA35. •HOLLOW CMU ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-1/4•A Eb6E DISTANCE OF 2-1/P:HOLLOW CMU,SHALL Be MEDIUM WEIGHT CONFORMING TO ASTM C 90. •CONCRETE ANCHMS_S14ALL HAVE A MIN.EMBEDMENT OF 1-31V A EDGE DISTANCE OF 2-1/2'.CONCRM SHALL BE •MET�ANCSHORSz SHALL HAVE A MIN.(3)THREADS PENETRATION BEYOND METAL STRUCTURE.STEEL SHALL BE MIN. 0 0 0 0 form(0.045'M41M 33 KSI YIELD.ALUMINUM SHALL BE MIN.Vr THICK ALUMINUM 6063 TS. 2"X 4"X 3 3/8" L-CLIP ttlttlttt) Q£10 s� selsfs ALUMINUM 6063-Tb `pttt S j�i' No 'r �r � ex° "aretx°�,rr�r "MUST BE USED IN PAIRS l .iaw.. Pa1t M�71l.FIO�ImM1tf�1� a HVHZ CUPPED.ALUMINUM TUBE MULLIONS NOTE:SEE SHEET 3 FOR SPECIFIC * * VERi1CAL AND HDRIZONTAI,CONFIGURATIONS 4. CLIP TYPES AND DIMENSIONS. : '• •� .•+i�(? =."'•'..I« •G����� 02/ 13 ar T - - adnart Di4oF 4r,� SPA: N.T mrDloxv+rmNNnxxa r ne+ oewrno+ xW F 11 a 2 CK� MULLION 0f516N pA13SttREUfAITS POR N11WON:1'x6"-ONEWAY MtAii9615 SPAN T "OKARYVA0IN W IN. MUU.ION tN. 18 24 1 30 36 42 1 48 S3.12S I % 60 24 2000 2000 I 2080 200:0 20A 200.0 200 I 200 11100 • 36 200.0 200 2000 2000 2000 200 20A 200.0 moa a8 200.0 200.0 200.0 moo 200 2000 200 2000 200.0 so 200 20.0 24.0 20.0 200 2000 .200 200 moo 72 200.0 20&0 200 201.0 200 147.0 169.0. 186.8 1➢01 81 200.0 IWO 200 19LO 17LS 1526 14a7 147.5 1401 96 20.0 200 U&S 1616 144.1 1313 1 WA 121.A 11L6 ONE-WAY MULLION DIAGRAMS 100 2mo 147.0 162.7 140.1 124.2 1126 103.9 IO&S 47.0u MMN PAMUK UNKIS MR MtJtUOW.r x V-TWO-WAYWWONS M�cN SPANT TAIBKAAYVADMmMW IN. MULLTOIN. 18 24 30 3e 42 49 53.125 54 GD 24 204. 2000 20.0 20.0 2000 20.0 �200 2000 2000 36 20O 200.0 200 200 200 "DO 200 200 200 48 200 20" 2000 2000 20.0 177.0 178.0 1751 157.660 200 200 200 200 IMI 1526 142.0 1401 126.177 20O 20MO 2000 175.1 150.1 1313 11&7 116.7 1061 ea 210 200 110.1.1. 154.1 128,7 1126 101.7 100.1 901 � ss 2m0 197.0 157.6 1313 112.5 94.5 a9a 976 Tae 2"X 6"MULLION TWO-WAY MULLION DIAGRAMS 109 200 175.1 1x01 116.7 SOD.1 e7.6 79.1 77.8 700 ALUMINUM 6005-(5 •. TRIBUTARY WIDTH_ � TABLE NOTES: L SEE SHEET i FOR INSTRUCTIONS ON USING TABLES.SEE SHEETS 4 AND S FOR TYPICAL INSTALLATION METHODS 6 CLIP bETAI S. QUALIFIED ANCHOR CLIPS 2. LINEAR INTERPOLATION BETWEEN LISTED WIDTHS AM SPANS IS ALLOWED. 3. SEE THIS SHEET FOR SPEMW MULLION DIMENSIONS. 4. SEE SHEET 3 FOR SPEW!lC OLID DIMENSIONS. 5. ANCHORREQUIIfEMENTS: •WOM#14 WOOD SCREWS . CAU;3/4'ITW TAPC(N S 0 0 0 0 -CONLRETE:1/4'ITWTAPO3NS •METAL,11V SELF OAXLINb SCREWS(GRADE 5) 6. INSTALLATION SUBSTRATES: •WOOD ANCHORS SHALL HAVE A M1Id.'EMBEDMENTOF i-ill'A EDGE DISTANCE OF Y.WOob SHALL BE MM S.G.=0.55. •HCN.LOW.CMU ANCHORS SHALL:HAVE A MIN.EMBEDMENT OF 1-1/4.8 EDGE bISTANCE OF 2-1/2'.HOLLOW CMU SHALL BE MEDIUM CONFORNM4&TO ASTM C 90. o•CONCRETE61A APSL NC1fM SHALL HAVE A MIII�THREADS PENETRATION BEYOND METAL'STRUCTURE.STEEL.SHALL BE NEM9EbMEW OF 1-3/41 a EDGEVSTANCE OF Z-Vr.CONCRETE SMALL BeR 1846(0.045 THICK)3 1 KSI YIELD.ALUMUWM SHALL BE MIN.1/B'THICK ALUMINUM 6063-T5. 0 0 0 0 2"X 4" X S 3/8" !CLIP `,��,,� S F � 4A. E�S+ l"11 .x •.x,� ALUMINUM 6063-T6 "KWAL WOOL' ♦Q q44'•,.. �i� .�....�...,..... .P,s`L!.... **MUST BE USED itd PAIRS ti:�t4' �.....�....... � Hv HZ CLIPPED ALUMINUM TUBE MULIJONS VERTICAL AND HORIZONTAL_ ION CLCONFIGURATIONS NE:SEE SHEET 3 FOROTSPECIFICIP TYPES AND DIMENSIONS.. �- �y.c�;•s p`••' � 42 13 TJ ,� ` xunlxlfae+dors,n�c. aawwrx m•e 7rcd�ratrA*EaP A-0043 NS.S. �s, ,xm+or�a,�mx�r�aernx 30 ss w xe am am="mx 4.v TO F 11 v: ;l EXAMPLES OF TWO-WAY MULLION ASSEMBUES EXAMPLESOF ONE-WAY MULLION ASSEMSUES MULL �---- MULL ---� SPAN I: r- - - --� SPAN SPAN'L' --fi —' W2. MULL L:J IU, Ll SPAN'L' ,W2. IN I -01 ■ HORIZONTAL MULLION HORIZONTAL MULLION TRANSOM OVER MULTIPLE UNITS MULTIPLE UNIT ASSEMBLY VERTICAL MULLION HORIZONTAL MULLION .Wir 'W2' SPAN' SPAN'L' 1 111 III MULL SPAN W VERTICAL.MULLION HINGED DOOR W/SIDELITE HORIZONTALMULLION HORIZONTAL MULLION NOTES: ,� g,S F.tjr� ♦i♦ i, }'� �(( ..���i • •��^�� y! rYw iawr^�,.w: � ROI�OMS015 DRAWINSS ARE DIAGRAMMATIC IN NATURE AND CONFIGURATIONS NOT • �i�'�..0 SPECIFICALLY SHOWN MAY Of EXTRAPOLATED FROM THOSE SHOWN. 2. IF THE LOADING TYPE CANNOT BE DETERMINED,USE TWO-WAY *e *.• VE 0�1„�VPp ALUM L MRIUM CONFlGUWONSS ASSEMBLY CONFIGURATION VALUES. 3, FENESTRATION PRODUCTS SHALL BE ANCHORED AS APPROVED. r �. �OR7C' We - :�� ,y 4.•'` `�" 02/05/13 T H ! webwemx+s.aw ♦♦. �.+ 1� owrF-Av-OMKT rrea�nrx�rzor �unmuunauNaars�e w °"" amawtw "w 1111 OF 11 aev 398 East Dania Beach Blvd. BUILDING DROPS Suite 338 A Perfect Solution in Every Drop Dania Beach, FL 33004 954.399.8478 PH CertMcate of Authorization:29578 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report Of Eastern Architectural Systems, Inc. HVHZ Clipped Aluminum Tube Mullions for Florida Product Approval FL# FL17472 Report leo. 3285 Florida Building Code 2010 & 5" Edition Per Rule 61G20-3 Method: 1 —A (Certification) Category: Windows Sub—Category: Mullions Product: HVHZ Clipped Aluminum Tube Mullions Material: Aluminum 6005-T5& 6063-T6 Prepared For: Eastern Architectural Systems 10030 Bavaria Road Ft Dyers, FL 33913 Prepared by: �• Hermes F. Norero, P.H. �;' 7 Florida Professional Engineer#73778 Date: 02/27/15 Contents: 'i ••••.......••' �� Evaluation Report Pages 1—4 NAL Digitally signed by Hermes F.Norero,P.E. 14111��o�����` `. Reason:I am approving this document Hermes F. Norero, P.E. Date:2015.02.28 12:40:59-05'00' Florida No.73778 f. BUILDING DROPS FL#: FL17472 A Perfect Solution in Every Drop Date: 02/27/15Report No: 3285 Certificate of Authorization:29578 Manufacturer: Eastern Architectural Systems,Inc. Product Category: Windows Product Sub-Category. Mullions Compliance Method: State Product Approval Rule 61G20-3 Product Name: HVHZ Clipped Aluminum Tube Mullions Scope: This is a Product Evaluation Report issued by Hermes F.Norero, P.E. (FL It 73778)for Eastern Architectural Systems,Inc. based on Rule Chapter No.61G20-3, Method 1a of the State of Florida Product Approval,Florida Department of Business and Professional Regulation-Florida Building Commission. Hermes F.Norero,P.E.does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the 2010&5th Edition Florida Building Code. See Installation Instructions PA-0003,signed and sealed by Bermes F. Norero, P.E.(FL#73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the 2010&51h Edition Florida Building Code,including the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the 2010&5th Edition Florida Building Code and does not require an impact resistant covering. Individual window units must be impact rated where applicable. j 4. Site conditions that deviate from the details of drawing PA-0003 require further engineering analysis by a licensed engineer or registered architect. S. All configurations shown in installation instructions PA-0003 have been qualified as required by section 1715.5.5 of the 2010 FBC and section 1710.5.3 of the 51h Edition FBC. 6. See Installation Instructions PA-0003 for size and design pressure limitations. F Hermes F. Norero, P.E. Florida No.73778 Page 2 of 4 f BUILDING DROPS FLM FL17472 A Perfect Solution in Every Drop Date: 02/27/15 Report No: 3285 Certificate of Authorization:29578 Certification Agency: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code and Rule 61G20-3 for manufacturing under a Certification Agency through Keystone Certifications,Inc.(FBC Organization#,:CER1523). Referenced Code Sections: 1. 1715.5.5 of the 2010 FBC 2. 1710.5.3 of the 51'Edition FBC Referenced Data: 1. Product Testing performed by: Certified Testing Laboratories (FBC Organization M T5T1577) Report M CTLA 301OW-,4 Report Date:07/18/14 Report M CTLA 3010W-4A Report Date:07/18/14 Report M CTLA 301OW-5 Report Date:07/18/14 Report#:CTLA 301OW-5A Report Date:07/18/14 Report M CTLA 301OW-6 Report Date:07/18/14 Report#:CTLA 3010W-6A Report Date:07/18/14 Report#:CTLA 301OW-7 Report Date:07/18/14 Report M CTLA 3010W-7A Report Date:07/18/14 Report#:CTLA 301OW-8 Report Date:07/18/14 Report#:CTLA 301OW-8A Report Date:07/18/14 Report#:CTLA 301OW-9 Report Date:07/18/14 Report M CTLA 3010W-9A Report Date:07/18/14 2. Certification Agency Keystone Certifications,Inc. (FBC Organization#:CER1523) T' J Hermes F. Norero, P.E. Florida No.73778 Page 3 of 4 BUILDING DROPS FL#: FL1747Z A Perfect Solution In Every Drop Date: 02/27/15 'Certificate of Authorization:2957$ Report No: 3285 installation: 1. Approved anchor types and substrates are as follows: A. For two by(2X)wood frame substrate,use#14 Wood Screw type wood frame anchors of sufficient length to achieve minimum embedment of 1.50"into wood framing. B. For concrete or masonry substrate where one by(1X),non-structural,wood bucking is employed,use 1/4"diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25"into concrete or masonry. C. For concrete or masonry substrate where wood bucking is NOT employed,use 1/4" diameter ITW Tapcon type concrete.screw anchors of sufficient length to achieve minimum embedment of 1.25"into concrete or masonry. D. For metal stud substrate,use 1/4"Grade 5 self-drilling screw type metal frame anchors of sufficient length to achieve a minimum three threads penetration beyond metal structure. Refer to Installation Instructions(PA-0003)for anchor locations,design load tables,and further details of the installation requirements. Design Pressure: See drawing PA-0003 for mullion desing pressure tables,mullion profiles,and installation details. s Hermes F.Norero, P.E. ; Florida No.73778 ' Page 4 of 4