HomeMy WebLinkAboutEngineering !~COOK & MENARD A CHITECTURE INC.
806 Delaware Avenue, F rt Pierce, Florida 34950
PHONE(772)460-7751 AX(772)460-4244
EMAIL cookme and@yahoo.com
September 13,2016
Saint Lucie County Building Department
Attn: Roof Permit Plan Review
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Roofing specification prepared for thet. Lucie County Building Dept.for the structure located at
124 Queen Ann Court, Saint Lucie Cou ty, Florida
Manufacturer: Gulf Coast Supply& anufacturing
Profiles: 26 GA GulfLok Roof P nel FL. #11651.12
Code: FBC 2014;Section R 9 5.10
Wind Speed: 165 MPH; Ultimate D sign Wind Speeds
Exposure: B
Mean Roof Height: 30' Maximum
Pitch: 5/12
Required Design Pressure: Zonel: -40.6 Z ne 2: -56.5 Zone3: -107.9
Maximum Uplift Pressure: Fastener spacing: -10 .5 psf @ 12" o.c.
Fasteners: #9-15x 1.5"w/sealing washing through panel rib, with'/." minimum penetration
spaced @ 12"o.c. zon 1,2,3
Underlayment: Soprema, Inc. FL#25 9.1 Resisto is a self-adhering,glass-mat reinforced,
sand-surfaced,sbs m dified bitumen
Roof Decking: Existing plywood shea hing to be nailed w/8d x2"ring shank nails @ 6"o.c.thru
out Zone 1,4" o.c. pe imeter& 6" o.c. field Zone 2, and 4" o.c. thru out Zone3
The above approved,as per Florida Building Code Co pliance acceptances, 2014 Florida Building Code,and the
Manufacturer's recommendations.
Respectfully Submitted,-
LL
i; Peter B' Cook
-Cook'&,Menard Architecture, Inc.
P (
Florida Registration No. AA 003494, NCARB Certification No. 31789