Loading...
HomeMy WebLinkAboutWind Load Calculation Company: The Home Depot At Home Services Job Description: Replacing windows and stor Prepared By: Amber Client Name: Richter Project Number: 9484772/9525571/952551 Version SO 0: - 4W 1 N w ,r Gk 20?2Structures lift"` k ��" .Conforms with A5cE710 DESIGN PRESSURES FOR WALL COMPONENTS&CLADDING Design Data Building Data R SED70 i6 Wind Velocity(mph) 160 Mean Roof Height 12 9 Risk Category 2 Building Width(ft) 43 Exposure Category C Building Length(ft) 63 Directionality Factor 0.85 Roof Slope (x:12) 4 Internal.Pressure Coefficient+/- 0.18 Design pressures listed below are: Allowable Stress OPENING OPENING LOCATION OPENING OPENING DIMENSIONS MAXIMUM POSITIVE MAXIMUM NEGATIVE MARK DESCRIPTION ZONE ELEVATION WIDTH(INCHES) HEIGHT(INCHES) PERSSURE(PSF) PRESSURE(PSF) 1 5500-SH 5 5 36 56 32.7 -43.4 2 5500-SH 5 5 36 56 32.7 -43.4 3 5500-SH 5 5 36 56 32.7 -43.4 4 5400-1PNL 5 5 56 63 31.5 -40.9 5 5400-1PNL 5 5 56 63 31.5 -40.9 6 5400-1PNL 5 5 56 63 31.5 -40.9 7 5400-PD-F 5 0 37 88, 31.7 -41.3 8 5400-1PNL 5 5 53 63 31.6 -41.2 9 5400-1PNL 5 5 53 63 31.6 -41.2 10 5400-1PNL 5 5 61 63 31.3 -40.6 11 5400-1PNL 5 5 61 63 31.3 -40.6 12 Accordion Shutter 5 5 86 75 30.2 -38.3 13 Accordion Shutter 5 5 66 66 31.1 -40.0 14 Accordion Shutter 5 5 40 48 32.9 -43.6 15 Accordion Shutter 5 5 40 61 32.3 -42.5 16 Accordion Shutter 5 5 40 61 32.3 -42.5 17 Accordion Shutter 5 5 66 48 31.8 -41.4 Width of End Zone(a)in feet=4.3 1 S h ' 4 a IL ST,00e ok's tNTERNAT(ONAL,LLC Feoti�'IrJO a1, e�od+t�.s b car+p�c,tho0kxns 8/30/201610:44 AM Si of I SPEC SHEETS 4 J U�l DEALER NAME THD AT HOME SERVICES BOXJCRATEORDER EMAIL SENT TIME SALES CONSULTANT STJ9yt- ❑YE; Q No ❑,YES ❑Ro DATE ORDERED BY PGT USE 2 CSR& mKv.-zim ❑ ALICEW.VIM ORDERED BY PHONES S.Ol DEALER a lzzza 01Y.5tArk F,:- '��_.: !-'c SHIP DATE . CUSTOMER � �f,r SHIP TOS SHIPVIA JOBS 93�`�'2s�'� ,MDI? ❑ -❑, RO LEADTIMEALi ' POS IF'NO'INDICATESTANDARD5 DESIRED CHECKERS INITIALS 0 wma mD REQUIRED FOR MIAMI DADS: SOLD ON PROMO ❑YES Q No ❑ WOODCPFHING ❑ auwmnanav ❑ RMCCE. ❑ NM CCYstaucTIM ❑ 1/4.55TAFCONS ❑.L4'S54CRETERM ❑ OMKRM MM% m mOPENINGSIZE .• o DOORS" DO 0 y (0 N ' El N Di 8r,p r Silo sr/ ►✓ l✓ ala SG Z (p✓Ir oi ,p ! i aSr/ v ✓ �3l0 3G 2 e,.r C 03 3 04 as D6 07 ' J OB cr= 09 f- N 10 J 11 ¢ 12 0. 13 14 m In 1s cv m 0 cu Nr have reviewed and agreed wlrh aff)nbspecfjlcarinns and the SpPdnfTemis R Conditions on the back ojthe,yellaw(Customer)copy. CD Customer Slgna a -Date 9-15 1, White-The Hama Depot Ye4lew-Customer THD-1030 Sheet If of ( SPECSHEETM 43072 DEALER NAME THD AT HOME SERVICES BOX/CRATEORDER EMAILSENT TIME^ SALESCONSULTANT �S'1'7!~/�'Z ❑ M ❑ No ❑ rm ❑ No C QC DATE g-��S'�(� ORDERED BY PGTUSE W CSR&FXT 11 ROM -- ❑ AUCEW.x2M3 ORDERED BY PHONE A _ S.O.# to N SHIP DATE DEALER N 1ZZ28 CITY,STATE f=r; }moi•e c r �� O CUSTOMER SHIPTON SHIP VIA JOBk r�'3,ZS�gp MDI? ❑ ❑ NO LEAD TIME AIiTN POLI IF'NO'INDICATE STANDARDS DESIRED CHECKERS INITIALS (D ❑ w1W.%WW(nom ❑ -C(N--AM REOUIRED.FOR MIAMI DADE: . SOLD ON PROMO [3 YES NO .. wow opaim41I UWD SatiY to 13P-a [I NEWCUSMUCRON p uTAPMNS ❑ 11v SrA aErsU:x ❑ cotimm OPEMO .• .• ..• SLIDE,oiva ON (Selling Measurements) 9 N 1 ` 1Ao r 02 11 03 L / oo Ti'�L ),/ // X wr C 04 p t l !✓ ee zmf 05 06 07 !L'L ) SVco /PN( {✓ lc f' AA y (n tv C °S 09 a `a N CA 11 p O 12 CD O 13 O to 14 15 1 hove reviewed and agreed with all Jab spedflcat/ons and the Specla(Terms&Conditions on the Bock of the yellow(Customer)copy. -0 Customer SIgnatuIW6Date T}10.t030 v-is WMte-The Hame Depot Yellow-Customer STORM PROTECTION PANELS,FABRIC,AND SHUTTERS SPECIFICATION SHEET SPEC SHEET#: 19331 /^ DATE: 8/95 � CUSTOMER J I E�t f rf£. JOB#: P s CONSULTANT; Q Finished Size of Barrier Erttnlsions UI Total(UI)OR Square Foot Foot Total C style Colar Location Floor Width Inches Hal ht Inches (SQFT) Headar Track LF SIR Track L Build out Depth L to LF Q x erg COVJY . CO 4 Itrly 5r0 / 0 W 5 ofs 7 e 9 10 • 11 12 13 14 = 15 a: O J M SPECIAL CONSIDERATIONS: Spec Sheet Com onents: - aUI Total(1.1I)1 Square Foot Total(SOFT) provide the UI for panels,Bahamas and colonial shutters,and SQFT for Accordions and Hurricane FabHo.S uare footage is calculated as finished width inches x finished height inches)divided by 144 inches Header Track-Add 6"to the finished width of the barrier for panels and shutters and 4"for fabric. SIII Track-Add W to the finished width of the harder for panels and shutters and 4"for fabric. O Build out depth -distance from the exterior wall of llie Crouse required to avoid obstacles. O Keep a minumum of 3"of space botween the glass of the window and the Stone Frotection. O L-angte measurement-Add 3"to the height on the leftand right side of the barrier.Material is used to cap sides of the panels. LD ti O 1 have reviewed and agree with all the Job specificatlons above and the,Special Terms and Conditions. (U N CUSTOMER SIGNATURE T-'✓L 620.77. NOele-Tb Homo C4pot Yellow-CUNamor 7X0.1009