HomeMy WebLinkAboutLomanco RV- FBC 2014Florida Building Code Online
http://www.floridabuilding.org/pr/pr_app dtl.aspx?param=w GE V X...
Equivalence of Product Standards
Certified By
1 of 2 10/1/2015 2:06 PM
'IA&i
BCIS Home i Log In ; User Registration F Hot Topics k
Submit Surcharge ' Stats &Facts Publications FBC Staff BCIS Ste Map j Links Search
_<petr
Bsines �=)
�
��� f ��Q(
Product Approval
USER: Public User
Regulation
Product Approval Menu > Product or Aoolication Search > Application
List > Application Detail
FL #
FL2847-R7
Application Type
Revision
Code Version
2014
Application Status
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Lomanco, Inc
Address/Phone/Email
2101 West Main
Jacksonville, AR 72076
(501)982-6511
acarter@lomanco.com
Authorized Signature
Andrew Carter
acarter@lomanco.com
Technical Representative
Andrew Carter
Address/Phone/Email
2101 West Main Street
Jacksonville, AR 72076
(501) 982-6511 Ext 361
acarter@lomanco.com
Quality Assurance Representative
Andrew Carter
Address/Phone/Email
2101 West Main Street
Jacksonville, AR 72078
(501) 982-6511 Ext 361
acarter@lomanco.com
Category
Roofing
Subcategory
Roofing Accessories that are an Integral Part of the Roofing System
Compliance Method
Evaluation Report from a Product Evaluation Entity
Evaluation Entity
Miami -Dade BCCO - EVL
Quality Assurance Entity
Miami -Dade BCCO - QUA
Quality Assurance Contract Expiration Date
08/16/2016
Validated By
Miami -Dade BCCO - VAL
Certificate of Independence
Referenced Standard and Year (of Standard)
Standard Year
Miami -Dade TAS 100(A) 1995
Equivalence of Product Standards
Certified By
1 of 2 10/1/2015 2:06 PM
Florida Building Code Online
Sections from the Code
http: //www. floridabuilding. org/pr/pr_app_dtl. aspx?param=w GE VX...
Product Approval Method Method 1 Option C
Date Submitted 06/29/2015
Date Validated 07/02/2015
Date Pending FBC Approval
Date Approved 07/09/2015
Summary of Products
sack next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
W 11120 s'4irex9
2 of 2 10/1/2015 2:06 PM
FL # Model, Number or Name
1 Description
2847.1 Lo-OmniRidge LOR9-4
Gun Nailable 4' Ridge Vent for 9" Cap Shingles
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL2847 R7 II LOR9-4 13070110.Ddf
Approved for use outside HVHZ: Yes
I Verified By: Miami -Dade BCCO - EVL
Impact Resistant: N/A
Created by Independent Third Party:
Design Pressure: N/A
Evaluation Reports
Other: 1. Refer to applicable building codes for required
I FL2847 R7 AE LOR9-4 13070110.Ddf
ventilation. 2. Omni Roll Ridge Vent shall not be installed on
roof hips. 3. Omni Roll Ridge Vent shall not be connected at
ridge intersection, nor within 12" of any side wall or roof
protrusion, with a ventilation slot clearance of 12" from such
I
obstructions. 5. Omni Roll Ridge Vent shall not be installed
on roof mean heights greater than 33 feet.
2847.2 Lo-OmniRoll LOR-30
30' Gun Nailable Shingle Over Ridge Vent
--
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL2847 R7 II LOR-30 13070111.Ddf
Approved for use outside HVHZ: Yes
Verified By: Miami -Dade BCCO - EVL
Impact Resistant: N/A
Created by Independent Third Party:
Design Pressure: N/A
Evaluation Reports
Other: 1. Refer to applicable building codes for required
FL2847 R7 AE LOR-30 13070111.Ddf
ventilation. 2. OmniRidge Vent shall not be installed on roof
mean heights greater than 33 feet.
2847.3 OmniRidge OR -4
4' Shingle Over Ridge Vent
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL2847 R7 II Lomanco OR -4 - NOA 11-0602.03.Ddf
Approved for use outside HVHZ: Yes
Verified By: Miami -Dade BCCO - EVL
Impact Resistant: N/A
Created by Independent Third Party:
Design Pressure: N/A
Evaluation Reports
Other: 1. Refer to applicable building codes for required
FL2847 R7 AE Lomanco OR -4 - NOA 11-0602.03.odf
ventilation. 2. OmniRidge Vent shall not be installed on roof
mean heights greater than 33 feet.
sack next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
W 11120 s'4irex9
2 of 2 10/1/2015 2:06 PM
MIAMI-DADE COUNTY
MIAMI.DIADE PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Lomanco, Inc.
2101 West main Street
Jacksonville, AR 72076
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Lomanco Lo -Omni Roll LOR-30 Ridge Vent
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 08-0611.05 consists of pages 1 through 4.
The submitted documentation was reviewed by Juan E. Collao, R.A.
NOA No.: 13-0701.11
Expiration Date: 09/04/18
Approval Date: 09/12/13
Page 1 of 5
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Ventilation
Materials: Plastic
Minimum Slope: 3:12
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Description
LOR-30 60" x 14 %2" x s/g" TAS 110 Ridge ventilation system
0.625" thick
TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS:
Test Product
Product Dimensions Specification Description
Roofing Nails Min. 12 ga. TAS 114 Appendix E Corrosion resistant annular ring
shank nails
Roofing Nails Min. 12 ga., TAS 114 Appendix E Corrosion resistant smooth shank
1 3/4" nails
MANUFACTURING LOCATION
1. Jacksonville, AR
EVIDENCE SUBMITTED:
Test AEency/Identifier
Celotex Corporation Testing Service
Celotex Corporation Testing Service
Celotex Corporation Testing Service
PRI Asphalt Technologies, Inc.
PRI Asphalt Technologies, Inc.
PRI Asphalt Technologies, Inc.
PRI Asphalt Technologies, Inc.
PRI Asphalt Technologies, Inc.
PRI Asphalt Technologies, Inc.
Name
ASTM D1929
ASTM D635
ASTM D638
ASTM D638
TAS 100
TAS 100(A)-95
ASTM D635
ASTM D638
ASTM D1929
ASTM G155
Report
MTS 520172
MTS 520172
MTS 520656
LOM -003-02-01
LOM -028-02-01
LOM -030-02-01
LOM -025-02-01
LOM -031-02-01
LOM -025-02-01
Manufacturer
Generic
Generic
Date
07/21/99
10/22/99
07/14/2000
01/15/03
08/28/13
07/23/13
05/30/13
07/23/13
05/30/13
NOA No.: 13-0701.11
Expiration Date: 09/04/18
Approval Date: 09/12/13
Page 2 of 5
APPROVED APPLICATIONS
Tradename: Lo -Omni Roll (LOR-30) Ridge Vent
System Type: Mechanical attachment of ridge vent system over composition shingles.
Slot: Truss Construction: Cut shall be 1-1/4" wide and 6" shorter at each end than the total
length of the ridge vent to be installed.
Ridge Pole Construction: Cut shall be 2-3/4"" wide and 6" shorter at each end than the
total length of the ridge vent to be installed.
Installation: Mark proper alignment and end line for vents with chalk; snap a chalk line down both
sides of the ridge at a distance of 7" down from the peak as shown in the
manufacturer's installation instructions.
Center the length of vent along the ridge. Start nailing with minimum 1 3/4" roofing
nails placed 6" on center at manufacturer pre -marked locations. Use nails of sufficient
length to penetrate through the sheathing a minimum of 3/16" or at least 1" into wood
plank decking thicker than 1". Cut lines are provided if more than one vent is being
used (See manufacturer installation manual). Additional pieces shall run in the same
direction as they unroll out of the carton.
Ridge Shingle: Using nail lines provided on top of vent, install the cap shingles directly to the vent, in
compliance with the shingle manufacturer's Notice of Acceptance (NOA) and
installation instructions, using roofing nails of sufficient length to penetrate through the
sheathing a minimum of 3/16" or at least 1" into wood plank decking thicker than 1
Ventilation Calculations: Refer to manufacturer's published literature.
NOA No.: 13-0701.11
Expiration Date: 09/04/18
Approval Date: 09/12/13
Page 3 of 5
LIMITATIONS:
1. Refer to applicable Building Code for required ventilation.
2. Ridge Vent shall comply with applicable Building Code.
3. Omni Roll Ridge Vent shall not be installed in conjunction with Gable vents.
4. Omni Roll Ridge Vent shall not be installed on roof hips.
5. Omni Roll Ridge Vent shall not be connected at ridge intersection, or within 12" of any side wall or roof
protrusion, with a ventilation slot clearance of 12" from such obstructions.
6. Omni Roll Ridge Vent shall not be installed on roof mean heights greater than 33 ft.
7. For application over laminated shingles, apply a bead of silicone caulking or roof cement to the underside of the
outer baffle and at exposed edges.
8. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 9N-3 of the Florida Administrative Code.
NOA No.: 13-0701.11
Expiration Date: 09/04/18
Approval Date: 09/12/13
Page 4 of 5
14.0
_.� c��€n'r=� �s`ir�ruv�tit�•�rn r�a�w�
6250
LO -OMNI ROLL RIDGE VENT LOR-30
END OF THIS ACCEPTANCE
NOA No.: 13-0701.11
Expiration Date: 09/04/18
Approval Date: 09/12/13
Page 5 of 5