Loading...
HomeMy WebLinkAboutProduct Approval (2) 9/29/2016 Florida Building Code Online _ :: #+ � o s • p e' • w BCIS Home I Lag In I User Registration I Hot Topics Submit Surcharge Stats&Facts Publications Fac Staff f BCIS Site Map Links f Search f Florida F e L ' 'Product Approval w (ET- - USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail a 4a FL# 1 L 4994=R1-- Application Type Revision Code Version 2014 Application Status Approved CommentsRECEIVED OCT 13 f.0i6 Archived Product Manufacturer Silverline Building Products Corp, Address/Phone/Email One Silverline Drive North Brunswick, NJ 08902 (800) 234-4228 Ext 4644 Jonberrian@slbp.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category `_Windows.- Subcategory Horizontal:Sliden' Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity Window and Door Manufacturers Association-QA Quality Assurance Contract Expiration Date 08/03/2021 Validated By Ryan J. King, P.E. ✓ Validation Checklist-Hardcopy Received Certificate of Independence FL14994 R1 COI CERTIFICATE of INDEPENDENCE.pdf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2011 AAMA/W DMA/CSA101/I,S.2/A440 2008 ASTM E1886 2005 ASTM E1996 2006 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr app_dd.aspx?param=wGEVXQwtDquZRj59p/p2fDrx2%2flDBR4OJnUDFrXPD2Dn7xsGdeKrPxxO3Qp/`3d`/o3d 1/3 9/29/2016 Florida Building Code Online Product Approval Method Method I Option D Date Submitted 04/27/2015 Date Validated 04/28/2015 Date Pending FBC Approval 05/04/2015 Date Approved 06/23/2015 Summa of Products FL# Model,Number or Name Description 14994.1 a. Series 2800 Model 2802 Extruded Vinyl Horizontal Slider Window with Nailing Fin -2 Panel (OX or XO Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14994 R1 II Inst 14994.1.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14994.1 for Design Pressure Ratings, any FL14994 R1 AE Eval 14994.1.pdf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14994.2 b. Series 2800 Model 2803/2804 Extruded Vinyl Horizontal Slider Window with Nailing Fn-3 Panel (XOX Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14994 R1 II Inst 14994.2.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14994.2 for Design Pressure Ratings, any F1114994:-RlAE Eval`14994:2.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14994.3 c. Series 8700 Model 8700 Extruded Vinyl Horizontal Slider Window with Flange-2 Panel (XX Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14994 R1 II Inst 14994.3.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14994.3 for Design Pressure Ratings, any FL14994 Ri AE Eva[ 14994.3.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14994.4 d. Series 8700-Model 8700FIN Extruded Vinyl Horizontal Slider Window with Nailing Fn -2 Panel (XX Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14994 RI' II Inst 14994.4.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 14994.4 for Design Pressure Ratings, any FL14994 RI AE Eva] 14994.4.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14994.5 e. Series 8800- Model 8803/8804 Extruded Vinyl Horizontal Slider Window -3 Panel (XOX Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14994 R1 II Inst 14994.5.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14994.5 for Design Pressure Ratings, any FL14994 RI AE 'Eval 14994.5:6df additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14994.6 f. Series 8800-Model Extruded Vinyl Horizontal Slider Window with Nailing Fn-3 8803/8804FIN Panel (XOX Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14994 R1 II Inst 14994.6.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports https:/A&ww.floridabuilding.org/pr/pr app dd.aspx?param=wGEVXQwtDquZRj59%2fDrx2%2flDBR4OJnUDFr)(PD2Dn7xsGdeKrPxxO3Q%3d%3d 2/3 9/29/2016 Florida Building Code Online Other:See INST 14994.6 for Design Pressure Ratings, any FL14994 RI AE Evat 14994.6:Ddf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14994.7 g. "WeatherStopper' "Series 8700 Extruded Vinyl "Impact"Horizontal Slider Window-2 Panel - Model 8700 IMPACT (OX or XO Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14994 RI II Inst T4994.7:Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 14994.7 for Design Pressure Ratings, any FL14994 RI AE Eval 14994.7.Ddf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14994.8 h. "WeatherStopper—"Series 8700 Extruded Vinyl "Impact" Horizontal Slider Window-2 Panel - Model 8700 IMPACT (OX or XO Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL14994 R1 II Inst 14994.8.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14994.8 for Design Pressure Ratings, any F1_14994 1111 AE Eva1 14994,'8.Ddf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. __ _ is-8700'-`Model 8700 Eitnided Vihy1 Horizontal Slider Window-2 Pariel-(OX,or X0� Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL14994 R1 II Inst 14994.9.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14994.9 for Design Pressure Ratings, any FL14994 RI AE Eval 14994.9:13df additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 3CL: Ei Contact Us:: 2601 Blair Stone Road,Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement:: Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: wiiiiw Credit Cara Safe https://www.floridabuilding.org/pr/Pr_app_o.aspx?param=wGEVXQwtDgLiZRj59`/p2fDrx2p/`2flDBR4OJnUDFrXPD2Dn7xsGdeKrPXX03Q`/`3d`/`3d 3/3 Silverbn6 = •o •o byAndersen * 8e Q_Z WINDOWS DOORSN � _ goo U(V.. ZxOZd SERIES 8 700 MODEL 8700 73"MAX.OVERALL FRAME WIDTH N v ID d`o a na v mdIT cn EXTRUDED VINYL o Ta HORIZONTAL SLIDER WINDOW10. i o "NON-IMPACT' QLU � w g GENERAL NOTESv O CMkf zo 1. This product has-been evaluated and is in compliance with the 5th Edition(2014) W o _ a .a Florida Building Code(FBC)structural requirements excluding the"High Velocity a a o Hurricane Zone"(HVHZ). dX m 2. Product anchors shall be as fisted and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3.. When used in areas requiring wind bome debris protection this product is required 7 N N _ to be protected with an impact resistant covering that complies wiftSection z 1609.1.2 of the FBC. W _N .. it- 4. 4. For 2x stud framing construction,anchoring of these units shall be the some as that o shown for 2x buck masonry construction. 5. , Site conditions that deviate from the details of this drawing require further engineering.analysis by a licensed engineer or registered architect. w ° F-- 0 O o a TABLE OF CON[ENTS z n o SHEEi9 nESCIMON - MAX `MAX GLASS DESIGN PRESSURE(PSF7' DATE: 11/16111 z m 1 Typical elevation,design pressures&general notes FRAME . DLO lypE' scAEE N.T.S. 2 Horizontal cross sections. DIMENSION DIMENSION.. , .,...:.. PQSITIYE .`NEGATIVE, owc.er: KV m 3 Vertical cross sections +50.0 -50.0 CHK.M LFS s z 4 Vertical cross sections 73:0"X 63.0" 316'X56.17' Gl DRAWING NO_ 5 Buck and frame anchoring FL-44994.9 6 1 B11 of materials,glazing decal and components N Ay _ ... SHEEP 1 OF 6 ®. f. G R\Clients\SiNedine Building Products-P\Flodda Product Approvals\FL-14994 Horizontal Slider\C-Drawings\FL 14994(2014)\FL-14994.3-.8.dwg,2.9 N� v 4 2 O N N N n v W tlt rZ a Q W' n H O O Z N w MA � A Q I° a Z m a I0 A N N N V Z O Q '• n N a A > n N z Z n .R� m O Z fig . ty Z �•Sic V' VCENBF••.�• �i No:43409 PRODUCT; Documante Prepared By- Lyndon Lyndon F. Schmidt �Vj'�31'•�O;1; IN D Z HORIZONTAL SLIDER WINDOW P.E. No. 43409 �FNAIa ��� pl PART OR ASSEMBLY: (rnj� BURRING CONSULTANTS, INC. ?7 Vl 1 _J/1 5/15 UPDATE TO 5TH ED. (2014 FBC JK V v�P,O. Box 230, Vplrtco, FL.33595 I°t --• N0. DATE BY HORIZONTAL Phone NoA 813.559.91:97 REVISIONS CROSS SECTIONS FSPE C.A. No. 91313 02011 R.W.a—DING NSULTANTe INC. R-'lOients\Silvedine Building Products-P\Flori&Product Approvals\FL-14994 Horizontal Slider\C-Dravdngs\FL 14994(2014)\FL-14994.3•.8,dwg,33' IiR 0 o W N A W n T C \V 4 < A r~ O o � y A n O O � 0 Z co •0 P�' �O m 1-1/4"MIN. o EMB.(TYP.) RR e. a H EMB.(TYP.) Z � m N zz S 'm.,r�l W A V 1-1/4'"MIN. '• EMB.(TYP.) A h a o 1-1/4"MIN. o n > EMB.(TYP.) D 3 a1 x m Z z rn rn N m rn xx o "•`. CIO)-I � O 1-1/4"MIN. EMB,(TYP.) W e � � n a' W W Vs r� a v m ` =r A p p a Z fir" o• �� r n Z 5C1 ply/ �li'i / No.43409 G .77y PRODUCT. Oeeunnentd Pn p—d R o _, Lyndon F. Schmidt ���'l��•'• OR{O�•'•G\`,�� K 43409 HORIZONTAL SLIDER WINDOW P.E. No. IW o z\ - �ifrrnnNt�` o ro '• y pl PART OR ASSEMBLY: r BUILDING.CONSULTANTS, INC. .Up - < ' 1 -371-871-5 UPDATE TO 5TH ED.. 2014) FDC JK P.O. Box.230, Va119co FL 33595 1 O1 DATE BY VERTICAL Phone No.: 813.859.9197 REVISIONS CROSS SECTIONS FSPE C.A. No. 9813 0 201 1 R.W.BUILDING CON5l1LTANT5 IND: R:\Clients\SBverline Building Products-P\Florida Product Approvals\FL-14994 Horizontal Slider\C-Drawings\FL 14994(2014)\FL-14994,3-.B.dwg,4.9 =r n ° w n fn N >r nn c �O I2� A 1-114,MIN. EMB.(TYP.( M A N • °' n to W O� V T n N o� o� oA 42 0 H Z � � IA .o t7� 1-IMMIN. ° t5 EMB.(TYP,) n m m O 07 m SIC ��.� �,c•�VcE1ueF'•.T .� ND.43409 frz�Yr i - D.—ante Prepared By.--'$ g PRODUCT: f20R.....• Lyndon F. Schmidt /�•�•'• HORIZONTAL, SLIDER WINDOW P/•/E� No. 43409 ''�sslONpLt�@` �' r— y Q, PART OR ASSEMBLY: �/� BUILDING CONSULTANTS, INC. �I N: 1 3 18/15 UPDATE TO STH ED..(2014 .FSC JK e/l� P.O. Box 230, Volrlco, FL 33595 1 NO DATE BY VERTICAL GR054 SECTIONS Phone No.: 813.659.9197 REVISIONS FBPE G.A. No. 9813 .(0 2131 1 R.W.BUILDING CONSULTANTS INC. `\\\ 4.. 4" -- 21.75' _47 '� ) (TYP-) I e 6 (TYP.). V.nil: �c 00.r (TYP.) a fnt� z 4 O�v' um Tq // ..• \\ N 'Ml a on •: F 2X BUCK I P z o z ci TYP.HEAD, \ h o a 9 'p o a a a 4 SILL&JAMB I I M 1XBUCK I \�` a (SEE NOTE 1) V N v m 2X I � LL 0 2X/ rz oz BUCK X BUCK o° a U MASONRY -0 MASONRY I H o OPENING 2X BUCK C4 II OPENING IIz o DIRECT TO v K Z I II I MASONRYLj W v M IXBUCK u) m En II I{ _oEt M U N U i o _ m dP t NOTE 1 .a ,• 6" INSTALLED THROUGH THE ALUMINUM 'm (1)ANCHOR IN EACH TRACK @ EACH LOCATION(TYP). p' (TYP-) STRAP ANCHOR(TYP) OFFSET ANCHORS IN 1X BUCK INSTALLATION AS FYN � e NECESSARY TO MAINTAIN MIN.CLEARANCE TO BUCK ANCHORING ADJACENT CONCRETE ANCHOR FRAME ANCHORINGo N 2X MASONRY Z p W (n CONCRETEANCHOR NOTES: 0 1..Concrete anchor locations at the comers may be adjusted to maintain the min. � a edge distance to mortar joints. - 2.Concrete anchor locations noted as."MAX.ON CENTER"must be adjusted to i omaintain the min.edge distance to mortar joints,additional concrete anchors d may be required to ensure"the'MAX.ON CENTER"dimension are not exceeded. 9 3. Concrete anchor table: W r ul MIN CLEARANCE MAIN CLEARANCE n ANCHOR ANCHOR M!N TO AAASONRY LO ADJACENT a n TYPE .- SIZEMBEUIVAENT z ...::.... .. _...:. _ :.. .EDGE:. ........ ITWDATE t 1/16/1 T ° TAPCON® SCAM N.T.S: ' m ELCO ® T/4" 1-1/4" 1" 4� nwc.BY. KV ; ULTRACON CHK.BY LFS WOOD SCREW INSTALLATION NOTES: oeAwiNc No.: 1.Maintain a minimum 5/8"edge distance,I"end distance,&T"o.c.spacing of FL-14994.9 0 wood screws to prevent the splitting of wood. N SHEET 5 OF 6 a 1.67'-14.81' BILL OF MATERIALS REM DESCRIPTION MATERIAL A 0 IX BUCK SG>=0.55 WOOD 7 0 �F-1•'9" �'�( Q •z .075' _ o, o;JCd n. B_ 2X BUCK SO>=0.55 WOOD aC1 C 1/4"MAX.SHIM SPACE STEEL n N,7 z o m D 114'X 2-3/4"ELCO OR ITW PFH CONCRETE SCREW STEEL I �y�� °N E O1 OR HOLLOWMASONRY- OPSI NUN.BLOCK CONFORMING�OFASTMING C OTO ACI STEEL L1I 1 -ANCHOR '�I �[ `�`` z d;o F #10 X 2"PPH SMS .1-1/8"MIN.EMBEDMENT STEEL 'Iirrll I lt`��„ °N o Z 3 MAIN FRAME v a 0 x z 4 H #8 X 1-3/4'PPH SMS 1-3/8"MIN..EMBEDMENT STEEL e E m z m o J #8 X.7S'PfT I SELFDRILUNG SMSSTEEL 1 y a 04. 9 0`o a K 1/4"X 1-3/4"ELCO OR ITW HH CONCRETE SCREW STEEL 1.56+' o N m'd a M 1/4"X 3-1/4"ELCO OR ITW PFH CONCRETE SCREW STEEL 0.36!'---1 t:j 0.070" L5 �o N #8 X J5'PPH SMS STEEL E D Z P #8 X 2-1/2-PPH SMS 1"MIN.EMBEDMENT STEEL 0.04"-�� m o rcu - 8 �Wd 1 STRAP ANCHOR#8795 6061-T6 ALUM STEEL 0.OT'11-1 { 2 2 GLAZING BEAD#9517• PVC z 3 -FI-- Z3 MAIN FRAME'#8701 PVC4 GLAZING SPACER(STEEL INTERCEPT) STEEL GIAANGBEAD 1.56" z 5 SASH REINFORCEMENT#8766(6063-T6 ALUM) ALUMINUM -- 8 1M.MTG.STILE 20 SASH RAIL o 7 PULL STILE#8706• PVC 7 PULL S17LE o } a z 8 INTERIOR MEETING STILE#8708• PVC En s 10 EXTERIOR MEETING STILE#8707• ALUMINUM 11 SILL INSERT#8722• PVC. o m 12 SASH KEEPER LOCK STEEL y T.56 �_v LL 16 FIXED WINDOW LOCK ALUMINUM o 1.54 oI 17 WEATHERSTRIP-FIN PILE - a a e 18 ,WEEP HOLE } I g 0.07" r 0 20 SASH RAIL#8704° PVC f�lIL-AX,m t 21 TTremGlazeS700 SILICONE L •THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED 0.065" I-1"-I 'BY EXTRUDERS LICENSEES IN"AAMA CERTIFICATION PROGRAMS FOR.RIGID PVC EXTRUSIONS'. 11 SILL TRACK 1D EXT MTG.S11LE x Ln � o 0 Ob"GLASS BITE w 0 3/4"THK..GLASS 5 ix 1.31" I,x i 1/ ANNEALt^-0.44" 8" ED w i w¢ F AIR SPACE '_ n m n O O Z L� 10ANNEALED I�(�'01" DAM' 11116111 0 4 ��JJ O O SCALE: N.T.S. v Dwo.:er: KV 2 m f� -i--0:82" GiAZING DETAIL4'— ►I CHK.BY. LFS 3 z G1 5 SASH REINFORCEMENT DRAWNC NO.: ;� I6 FIXED WINDOW LOCK FL-14994.9 h SHEEP 6 of.6 Ig O ' cc