Loading...
HomeMy WebLinkAboutProduct Approval (3) 9/29/2016 Florida Building Code Online r e 1.1 • SCIS Home Log In I User Registration Hot Topic Submit Surcharge Stats&Facts I Publications FBC Staff BCIS Site Map I Links I Search Ff0'1GI3 a: Product Approval -'USER:Public User FILE COM Product Approval Menu>Product or AppliCation Search>Application List>Application Detail FL# FL14937=R3_ Application Type Revision Code Version 2014 Application Status Approved Comments RECEI�j�� Archived Product Manufacturer Silverline Building Products Corp. Address/Phone/Email One Silverline Drive North Brunswick, NJ 08902 (800) 234-4228 Ext 4644 Jonberrian@slbp.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Jon Berrian Address/Phone/Email One Silverline Drive North Brunswick, NJ 08902 (732) 435-1000 Jonberrian@slbp,com Quality Assurance Representative Address/Phone/Email Category Windows_�_ Subcategory Ucaserrient :_—_1 Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer � Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity Window and Door Manufacturers Association Quality Assurance Contract Expiration Date 08/03/2021 Validated By Ryan J. King, P.E. -' Validation Checklist- Hardcopy Received Certificate of Independence FL14937 R3 COI CERTIFICATE of INDEPENDENCE.Ddf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2011 AAMA/W DMA/CSA 101/I,S.2/A440 2008 ASTM E1300 2004 ASTM E1686 2005 ASTM E1996 2005 ASTM E1996 2006 TAS 201, 202, 203 1994 Equivalence of Product Standards hftps://www.floridabuilding.org/pr/pr app_ctl.aspx?param=wGEVXQwtDquZRj59%2fDrx21xF4NsOy4SgOWn2lMPL!ScRuJFCGP7LIg°/`3d`/`3d 1/4 9/29/2016 Florida Building Code Online Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/09/2015 Date Validated 04/13/2015 Date Pending FBC Approval 04/27/2015 Date Approved 06/23/2015 Summa of Products FL# Model,Number or Name Description 14937.1 a. Series: 70 Extruded Vinyl Casement Window- (X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14937 .R3 H Inst 14937.1.1) Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A 'Evaluation Reports Other:See INST 14937.1 for Design Pressure Ratings, any FL14937 R3 AE Eval`14937.1.pdf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14937.2 b. Series: 70 Extruded Vinyl Integral Mulled Twin,Triple and Quad Casement Window- (XX, XXX and XXXX configurations) Note -Active panels can be interchanged with fixed Casement Sashes. Limits of Use . Installation Instructions Approved for use in HVHZ: No FL14937 R3 II Inst 14937.2.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14937.2 for Design Pressure Ratings, any FL14937 R3 AE Eva[ 14937.2.pdf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14937.3 c. Series: 70 Extruded Vinyl Integral Mulled Casement or Casements with I. Picture Window - (XOX and XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14937 R3 II Inst 14937.3.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14937.3 for Design Pressure Ratings,any FL`14937 R3 AE Evaf 14937.3.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. i 14937.4 d. Series: 70 Extruded Vinyl Integral Mulled Single or Twin Casement over .Picture Window or Picture over Single or Twin Casement Window- (X/0,XX/O or O/X,O/XX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14937 R3 II INST 14937.4 Product Offerino.pdf Approved for use outside HVHZ: No Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:This Product is No Longer Offered by Silverline FL14937 R3 AE EVAL 14937.4 Product Offerfna:pdf Building Products, Corporation (See 14937.4-2010 FBC Created by Independent Third Party: Yes version for Historical Documents regarding this Approval) 14937.5 e. Series: 70 Extruded Vinyl Casement Window with Nailing Fn- (X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14937 R3 II Inst 14937.5.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14937.5 for Design Pressure Ratings, any FL14937 R3 AE Eval 14937.5.pdf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. https://www.floridabuilding.orgtpr/pr app dtl.aspx?param=wGEVXQwtDquZRj59%2fDrx2lxF4NsOy4SgOWn2lMPLiScRuJFCGP7Ug%3d%3d 214 9/2912016 Florida Building Code Online 14937.6 f. Series: 70 i.Extruded Vinyl Integral Mulled Twin,Triple and Quad Casement Window with Nailing Fn-(XX,XXX and XXXX configurations) Note-Active panels can be interchanged with fixed Casement Sashes. Limits of Use Installation Instructions Approved for use in HVHZ: No FL1:4937 113<II Inst 14937.6:odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14937.6 for Design Pressure Ratings, any �FL14937 iR3 AE�Eval Q4937.5,odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14937.7 g. Series: 70 Extruded Vinyl Integral Mulled Casement or Casements with Picture Window with Nailing Fn - (XOX and XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14937 R3•II Inst 14937.7.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14937.7 for Design Pressure Ratings, any FL14937 R3 AE Eval 14937.7.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14937.8 h. Series: 70 Extruded Vinyl Integral Mulled Single or Twin Casement over Picture Window or Picture over Single or Twin Casement Window with Nailing Fn- (X/O,XX/O or O/X, O/XX configurations) ,Limits of Use Installation Instnictions Approved for use in HVHZ: No FL14937 R3 Ib INST 14937.&Product OfferinazDdf Approved for use outside HVHZ: No Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:This Product is No Longer Offered by Silverline 'FL14937`R3 AE 'EVAL 14937.8'Product Offering.Ddf Building Products, Corporation (See 14937.8-2010 FBC Created by Independent Third Party: Yes version for Historical Documents regarding this Approval) `i:Series: =70:.... E'_—:Extruiied Vinyl Casehient�Window ,(X configurati6n)" a--._ Limits of Use Installation Instructions Approved for use in HVHZ: No FL14937 R3 II Inst 14937.9.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14937.9 for Design Pressure Ratings, any FL14937 R3 AE Eval 14937.9.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14937.10 j. Series: 70 Extruded Vinyl Casement Window with Nailing Fn- (X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14937 R3 U Inst 14937.10.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A 'Evaluation Reports Other: See INST 14937.10 for Design Pressure Ratings, any FL14937 R3 AE Eval"1'4937.1'0todf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14937.11 k. Series: 70 Extruded Vinyl Casement Window- (X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL14937 R3 II Inst 14937.11.0df Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14937.11 for Design Pressure Ratings, any FL14937 R3 AE Eval 14937.11.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14937.12 I. Series: 70 Extruded Vinyl Casement Window with Nailing Fn- (X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL14937 R3 IT Inst 14937.12.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports https://www.floridabuiiding.org/pr/pr app d.aspx?param=wGEVXQwtDquZRj59%2fDrx2IxF4NsOy4SgOWn2lMPLiScRuJFCGP7Ug%3d%3d 3/4 9/29/2016 Florida Building Code Online Other:See INST 14937.12 for Design Pressure Ratings, any FL14937 R3 AE Evaf'149371.12;Rdf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 82tit I'v'e:c4 Contact Us:: 2601 Blair Stone Road,Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida..:: Privacy Statement::Accessibility Statement:: Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card: Safe https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquZRj59°/p2fDrx21XF4NsOy4SgOWn2lMPUScRuJFCGP7LIg%3d%3d 4/4 SilverLine Qp "" byAndersen Q.z `A� p� n ref p 36.0"MAX. itY I ISL 1.0 ® YY S D ® O f� OVERALL ��� ,�•i��� o CO FRAME WIDTH ��/i////lll*► „ `� d U N o SERIES 70 ® MODEL 7ORCW11MP M� 9 4 a(L EXTRUDED VINYL CASEMENT WINDOW ,���/ a E 4z �a "IMPACT" i i w oZ GENERAL NOTES o X o a 1. This product has been evaluated and is in compliance with the 5th Edition \\ F c N " (2014)Florida Building Code(FBC)structural requirements excluding the"High \ al 0 e o Velocity Hurricane Zone"(HVHZ). \\ a z 2. Product anchors shall be as listed and spaced as shown on details.Anchor /� \\ m embedment to base material shall be beyond wall dressing or stucco. \ 3. When used in areas requiring wind borne debris protection this product \ o complies with Section 1609.1.2 of the FBC and does not require an impact \ resistant covering.This product meets missile level"D"and includes Wind Zone 4 a z v as defined in ASTM E1996. g s 4. For 2x stud framing construction,anchoring of these units shall be the same as " that shown for 2x buck masonry construction, °o y y y 5. Site conditions that deviate from the details of this drawing require further z g engineering analysis by a licensed engineer or registered architect. w TABLE OF CONTENTS w m SHEET# DESCRIPTION N O c 1 Typical elevations,general notes and design pressures `MAX-`0`A" 11128111 MAX DESIGN PRESSURE PSP " z o DaTE: z 2 Horizontal cross sections FRAME DLO ._ GLASS - seal£: N.T.S. ° b 3 Vertical cross sections DlMENS lON :` DIMENS►QN 7YPE POSITIyE ' NEGAilYE Dwo.Dv: KV m 4 Buck and frame anchoring 5 811 of materials,components and glazing delals 36.0"X 72.0" 29"X 65" G1,G2 -50.0 50.0 CHK.BY: LFS 3 t -- - DRAWNG NO.: ¢ FL-14937.9 0 SHEET_L OF S N d R,.\Clients\Siiverline Building Products-P\Florida Product Approvah\FL-14937\C-Drawings\FL 14937(2014)\FL-14937.9-.12.dwg,211 4 a4 O O O� ww x r7 B mmmX y m H A In A N Qa �° D N ITi � JL M 0 m O p M N N w N a� A �O N `e 70 i N �O ZN QD UA o BDF D -o a N T ° n T <v m N tr �- m m A :n Z u A_ Z O A aD A N N N D O o Da �N n v0 o� a °v o m rn ° Rrn H m- rn m A Z ?Z .Sc `�` V•.`•�•VCPltB�e'•.1• �� N0.43409 m $ x E PRODUCT: Doeum.nte Prepared By:%V, _ � SILVERLINE Lyndon F. Schmidt g SERIES 70 P.E- No. 43409 / � [NO 3/18 IS UPDATE Tb 5TH ED. (2014)F8C JKCASRIENT WINDOWoW � � 2/20 13 REVISE DRAWING NO. LFS PART OR ASSEMBLY: K //BUILDING CONSULTANTS, INC. in6/20 12 REVISE SNUBBERS JKHORIZONTAL CROSS SECTIONS d LvYP.0 8ox 230, Volrico,fL 33595 'DATE BY Phone No.: 813.659.9197 REVISIONS F13PE CA No. 9813 0 201 1 R.W.BUILDING CONSULTANTS INC. R:Gients\Silverline Building Products-PiFlodda Produa App,.,& FL-14937\C-Drmings\FL 14937(2014)\FL-14937.9-.12dwg 213 Z J -xi N m m 0 X N N O r�r w J i2 N A � A ww ° om G �. 'a0 a ��� A Q 30 g� ° ❑n C w a 2 m m y Z e A IF2 A n V m a 0 1-1/4"MIN. O m EMB.(TYP.) x a co N m 2m N _ ` m N bf wN _ N � A A m a ;a Q C-3 o a gm za z 0 _ o .a rn I0 J Am N O O J n v Z N 1-1/4"MIN. EMs.(TYP.) v •1 ��o`�F SCNnj//�''/. No.43409 Yv-/f T SILVERUNE Lyndon F-x ` g PRODUCT: ,D—merdn P.pered By: o _ �••• Schmidt SERIES 70 P.E. No. 43409 IW o 3 3 18 15 UPDATE TO 5TH ED. (2014 FBC JK CASEMENT WINDOW 111111 o W x y 2 2/20/13 REVISE DRAWING NO. LFS PART OR ASSEMBLY: �(/(�BUILDING CONSULTANTS, INC. IWN < - 1 6 20 12.REVISE SNUBBERS JK VERTICAL CROSS SECTIONS P'O- Box 230, Va)r7co, FL 33595 . cD 'NO DATE BY Phone No.: 813.659.9197 REVISIONS I I FBPE C.A. No. 9813 Q 201 1 R.W.BumniNG CnNSII-TS 1Nc. 2X BUCK 27 330 s 1`�,�r .......... . 1XBUCK OL .'� pp.) d 10 y o u' * Ab&h((nn CO A 'a. a •ea — rN 33 /LIlI1 L U10 `aZn v prmn �� 9 u oau (TYP•) E oZ _ MASONRY 2X BUCK 2X BUCK v � TYP. z Q JAMB, G 2X BUCK w o 0 FRAME HEAD& F 1 X BUCK C'g SILL H DIRECTTO o w~ MASONRY o hCL w m mm s y � � MASONRY W �j OPENING _ ¢ -'d MASONRY O J ' o Y OPENING J L2XBUCKO FO o MN o CV •e' "a. 4.. THRU PIVOT TRACK a CS z zo 0 Ln w BUCKANCHORING JAMB FRAMEANCHORING JAMB o 7 i a, Retainer Snubbers 'Mason buck construction LockingPonts ow CONCRE7EANCHOR NOTES: ry Sash removed for clan Shown In the locked position ¢w w a 1.Comets anct to mor locations at the confers may be adjusted to motnfa(n the min. 5lockin y �+ edge dcsfarec�9tomatarjoinis. locking = ci '$ 2 Concrete anchor locations noted as"MAX.O.C.(TYPJ"must be adjusted to z ? maintain the mfn.edge distance to mortar joints,additional concrete anchors maybe required to ensure the MAX.O.C.(TYP)"dimensions are not exceeded. \ \w 3.concrete anchor taWe moor �d ANCHOR NCHOR MIN MIN CLEARANCE MIN CLEARANCE n w J TYPE .SIZE EMBEDMEF)i TOMgSQNRY; TOAI)JgCEN7'_, _ ,,...:.:: ..:,;:;..EDGE•..,:; � ....:.:ANCHOR �:.:; v $ Irw DATE: 11128111 i S TAPCON® 1/4" 1.1/4 2" 4" X SCALE: N.T.S. v TRCO s 1/4" 1.1/4" 1" 4" DWO.BY: 1!V m m' ULTRACON IRY CHK.BY: LFS 3 TAP N-, 3/16" 1.1/4" 3" 1.1/2" DRAWING NO.: LA WOOD SCREW INSTALLATION NOTES: FL—14937.9 5 1.Mofntotn a minimum 5/8"edge drstance,Pend distance,&I"o.c.spacing of _ N G WOOd screws to prevent the splifting of wood. SHEET 4 OF 9 c BILL OF MATERIALS 1/2"GLASS BITE ••......••, �i� REM# DESCRIPrIDN MATERIAL I ���� �• • oCki A 1X BUCK SG>=0.55_ WOOD 16 B 2X BUCK SG>=0.55 . WOOD 2 3/4"OVERALL = z po ;rL' C 1/4"MAX.SHIM SPACE THK.GLASS 0` 0 D 114'X 2-0/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 3/37'ANNEALED �''• �% E MASONRY-3,000 PSI MIN.CONCRETE 01 OR HOLLOW BLOCK CONFORMINGTOASTM IC ONG TO ACI CONCRETE f PVB INTERLAYER /��� •••*• `` F 114'X 3-1/4"PFH ITW CONCRETE SCREW STEEL i3 Z 3/32"ANNEALED o G #10 X 2-1/2"PPH SMS STEEL ° _z o z chi H 114"X 2-1/4"PFH ELCO OR ITW CONCRETE SCREW STEEL AIR SPACE 9 a o a 1 #8 X 2"PFH SMS STEEL 3/37'ANNEALED L 3/16"X 2-3/4"ITW FH CONCRETE SCREW STEEL M I 3116'X 3-1/4"PFH ITW CONCRETE SCREW STEEL 13 B z N 3/16"X 2"PFH ITW CONCRETE SCREW STEELa 1 I CASEMENT MAINFRAME (#52-CA20-001) PVC G2 LAZING DETAIL 3 3A 3B L3 2 CASEMENT MAIN SASH (#52-CA20-002)' PVC a 3 CASEMENT GLAZING BEAD HALF MOON-3/4"IG(#52-CA20-003)' PVC 1/2zo "GLASS BITE w 3A CASEMENT GLAZING BEAD BOX-3/4"IG(#52-CA20-011)'., PVC 0 3 3B _CASEMENT GLAZING BEAD CONTOUR-3/4"IG(#52-CA20-012)' PVC } s 4 LOCK HANDLE ASSY,(MULTI POINT LOCK) STEEL 16 5 SNUBBER(TRUTH#22999.92) 41 6 SNUBBER RETAINER (TRUTH#22999.92) 3/4"OVERALL o 7 CASEMENT OPERATOR(ENCORE DUAL ARM) STEEL THK,GLASS 8 Q-BULB SEAL.360 DIA, c 0,89"-�{ 3/32"ANNEALED °�Z 10 LOCKING BAR RETAINER CLIP STEEL I � o a 0.090"SAFLEX® � o 11 TRACK REINFORCEMENT #50-7555) ALUM.6063-T5 PVB INTERLAYER a a 3/32 ANNEALED 12 WEATHER-STRIP COMPRESSION TYPE y m 13 GLAZING SPACER STEEL INTERCEPT STEEL T o AIR SPACE F 14 SASH REINFORCEMENT(#50-CA20-013). ALUM.6063-T5 15 1/2"SNAP-ON EXTERIOR FLANGE(#52-CA20.058)'-OPTIONAL PVC 3/37'ANNEALED 16 GLAZING COMPOUND-TremOlaze S700 by TREMCO SILICONE 3 PVC GAZING BEAD 17 a 17 SUPERSPACER BUTYL N F 27 #8 X 1.3/4"PAN HEAD SMS STEEL GI GLAZING ETAI! 3 3A 3B d z z o 33 TIE BAR LOCK PIN STEEL Q B z 'THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONSEx FOR WINDOWS ARE TO BE PRODUCED BY EXTRUDERS o o 0 V LICENSEES IN"AAMA CERTIFICATION PROGRAMS FOR RIGID y y e PVC EXTRUSIONS". a °z 0 a� ^;w z g 0.891" —I o I 0,891" 11 Q N Ncli J �1 PVC GLAZING BEAD PVC GLAZING BEAD w _ 0.05' 0.059" 3B rJ1I O o "' O O DATE: 11128111 2 L il a0.42"-fes-►1 SCAM N.T.S. 0.625' I., DWG.BY: KV m II CHK.BY: LFS 3 2.43" 3.25' DRAWINO No.: a 14 SASH REINFORCEMENT 15 EXTERIOR FLANGE T L TRACK REINFORCEMENT O SASH FRAME 1 WINDOW FRAME FL-14937.9 p 14"Lg. Optional ALUM.6063-T5 N SHEET 5 0 S Q K