HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 5
BCIS Home i Log In User Registration i Hot Topics ; Submit Surcharge ; Stats&Facts 1 Publications ; FBC Staff BCIS Site Map Links Search
Honda
DDProduct Approval
USER:Public User
,yrs
,..�-x�✓sr�sio:
Product Aporoval Menu>Product or Application Search>Application List>Application History>Application Detail
g FL# FL17184-R2
Application Type Editorial Change
Code Version 2014
Application Status Approved
Comments
Archived O
Product Manufacturer Plastpro Inc./Nanya Plastics Corp.
Address/Phone/Email 5200 W CENTURY BLVD.
LOS ANGELES,CA 90045
(440)969-9773 Ext 16
rickw@rwbldgconsultants.com
Authorized Signature Vivian Wright
rickw@rwbldgconsultants.com
Technical Representative Scott Johnson
Address/Phone/Email 5200 W Century Blvd.
Los Angeles,CA 90045
(440)969-9773 Ext 18
scottjohnson@plastproinc.com
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
® Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E.
the Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation&Management Institute
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Ryan J.King,P.E.
© Validation Checklist-Hardcopy Received
Certificate of Independence FL17184 R2 COI CERTIFICATE of IN DEPENDENCE.odf
Referenced Standard and Year(of Standard) Standard Year
AAMA/W D MA/CSA 101/I.S.2/A440 2005
ASTM E1886 2005
ASTM E1886 2002
ASTM E1996 2002
ASTM E1996 2006
ASTM E1996 2005
ASTM E330 2002
TAS 201, 202, 203 1994
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvCo3 EapiIIB... 10/17/2016
Florida Building Code Online Page 2 of 5
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 07/17/2015
Date Validated 07/19/2015
Date Pending FBC Approval 08/09/2015
Date Approved 10/16/2015
Date Revised 03/10/2016
Summary of Products
Go to Page O Page 1/3
FL# Model,Number or Name Description
17184.1 a.Fiberglass Door Up to a 3'0 x 8'0 Glazed"Impact"Fiberglass Single Door(X
Configuration)Inswing/Outswing
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL17184 R2 II Inst 17184.1.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 17184.1 for any additional use limitations, FL17184 R2 AE EVAL 17184.1.Ddf
Installation instructions and product particulars. Created by Independent Third Party:Yes
17184.2 b. Fiberglass Doob Up to a 3'0 x 8'0 Glazed"Impact"Fiberglass Single Door
with a Sidelite(OX or XO Configurations)Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.2.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 17184.2 for any additional use limitations, FL17184 R2 AE EVAL 17184.2.Ddf
installation instructions and product particulars. Created by Independent Third Party: Yes
17184.3 c.Fiberglass Door Up to a 3'0 x 8'0 Glazed"Impact"Fiberglass Single Door
with Sidelites(OXO Configuration) Inswing/Outswing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.3.Ddf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 17184.3 for any additional use limitations, FL17184 R2 AE EVAL 17184.3.1)df
installation instructions and product particulars. Created by Independent Third Party:Yes
17184.4 d. Fiberglass Door Up to a 6'0 x 8'0 Glazed"Impact"Fiberglass Double Door
(XX Configuration) Inswing/Outswing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.4.Ddf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 17184.4 for any additional use limitations, FL17184 R2 AE EVAL 17184.4.1)df
Installation instructions and product particulars. Created by Independent Third Party:Yes
17184.5 e. Fiberglass Door Up to a 6'0 x 8'0 Glazed"Impact"Fiberglass Double Door
with Sidelites(OXXO Configuration)Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.5.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 17184.5 for any additional use limitations, FL17184 R2 AE EVAL 17184.5.Ddf
installation instructions and product particulars. Created by Independent Third Party: Yes
17184.6 f.Fiberglass Door Up to 3'0 x 8'0 Glazed"No n-Impact"Fiberglass Single Door
(X Configuration)Inswing/Outswing
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvCo3 EapiIlB... 10/17/2016
Florida Building Code Online Page 3 of 5
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II Inst 17184.6.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 17184.6 for any additional use limitations, FL17184 R2 AE EVAL 17184.6.1)df
installation instructions and product particulars. Created by Independent Third Party:Yes
17184.7 g.Fiberglass Door Up to a 3'0 x 8'0 Glazed"Non-Impact"Fiberglass Single
Door with a Sidelite (OX or XO Configurations)
Inswing/Outswing
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL17184 R2 II INST 17184.7.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 17184.7 for any additional use limitations, FL17184 R2 AE EVAL 17184.7.pdf
installation instructions and product particulars. Created by Independent Third Party:Yes
17184.8 h.Fiberglass Door Up to a 3'0 x 8'0 Glazed"Non-Impact"Fiberglass Single
Door with Sidelites(OXO Configuration)Inswing/Outswing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.8.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 17184.8 for any additional use limitations, FL17184 R2 AE EVAL 17184.8.1)df
installation instructions and product particulars. Created by Independent Third Parry:Yes
17184.9 1. Fiberglass Door Up to 6'0 x 8'0 Glazed"No n-Impact"Fiberglass Double Door
(XX Configuration) Inswing/Outswing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.9.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 17184.9 for any additional use limitations, FL17184 R2 AE EVAL 17184.9.pdf
installation instructions and product particulars. Created by Independent Third Party:Yes
17184.10 J.Fiberglass Door Up to a 60 x 8'0 Glazed"Non-Impact"Fiberglass Double
Door with Sidelites(OXXO Configuration)Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.10.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 17184.10 for any additional use FL17184 R2 AE EVAL 17184.10.pdf
limitations,installation instructions and product particulars. Created by Independent Third Party:Yes
17184.11 k.Fiberglass Door Up to a 3'0 x 6'8 Opaque"Impact"Fiberglass Single Door(X
Configuration)Inswing/Outswing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.11.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 17184.11 for any additional use FL17184 R2 AE EVAL 17184.11.pdf
limitations,installation instructions and product particulars. Created by Independent Third Party:Yes
17184.12 1.Fiberglass Door Up to a 3'0 x 68 Opaque"Impact"Fiberglass Single Door
with a Sidelite(OX or XO Configurations)Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.12.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 17184.12 for any additional use FL17184 R2 AE EVAL 17184.12.pdf
limitations,installation instructions and product particulars. Created by Independent Third Party:Yes
17184.13 m.Fiberglass Door Up to a 3'0 x 6'8 Opaque"Impact"Fiberglass Single Door
with a Sidelite(OXO Configuration)Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.13.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 17184.13 for any additional use FL17184 R2 AE EVAL 17184.13.pdf
limitations,installation instructions and product particulars. Created by Independent Third Party:Yes
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvCo3 EapiIIB... 10/17/2016
Florida Building Code Online Page 4 of 5
17184.14 n.Fiberglass Door Up to a 6'0 x 6'8 Opaque"Impact"Fiberglass Double Door
(XX Configuration) Inswing/Outswing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.14.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 17184.14 for any additional use FL17184 R2 AE EVAL 17184.14.odf
limitations,installation instructions and product particulars. Created by Independent Third Party:Yes
17184.15 o. Fiberglass Door Up to a 610 x 6'8 Opaque"Impact"Fiberglass Double Door
with Sidelites(OXXO Configuration)Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.15.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 17184.15 for any additional use FL17184 R2 AE EVAL 17184.15.odf
limitations,installation instructions and product particulars. Created by Independent Third Party:Yes
17184.16 p. Fiberglass Door Up to a 3'0 x 8'0 Opaque"Impact"Fiberglass Single Door(X
Configuration)Inswing/Outswing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.16.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See IN ST 17184.16 for any additional use FL17184 R2 AE EVAL 17184.16.odf
limitations,installation instructions and product particulars. Created by Independent Third Party:Yes
17184.17 q. Fiberglass Door Up to a 3'0 x 8'0 Opaque"Impact"Fiberglass Single Door
with a Sidelite(OX or XO Configurations)Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL17184 R2 II INST 17184.17.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 17184.17 for any additional use FL17184 R2 AE EVAL 17184.17.odf
limitations,Installation instructions and product particulars. Created by Independent Third Party:Yes
17184.18 r.Fiberglass Door Up to a 3'0 x 8'0 Opaque"Impact"Fiberglass Single Door
with a Sidelite(OXO Configuration)Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.18.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 17184.18 for any additional use FL17184 R2 AE EVAL 17184.18.odf
limitations,installation instructions and product particulars. Created by Independent Third Party:Yes
17184.19 s.Fiberglass Door Up to a 6'0 x 8'0 Opaque"Impact"Fiberglass Double Door
(XX Configuration) Inswing/Outswing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.19.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 17184.19 for any additional use FL17184 R2 AE EVAL 17184.19.odf
limitations,installation instructions and product particulars. Created by Independent Third Party:Yes
17184.20 r.Fiberglss Door Up to a 6'0 x 8'0 Opaque"Impact"Fiberglass Double Door
with Sidelites(OXXO Configuration)Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R2 II INST 17184.20.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 17184.20 for any additional use FL17184 R2 AE EVAL 17184.20.1)df
limitations,installation instructions and product particulars. Created by Independent Third Party: Yes
Go to Page O id 44 Pagel 3 40 a
Back Next
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvCo3 EapiIIB... 10/17/2016
Florida Building Code Online Page 5 of 5
The State of Florida is an AA/EEO employer.roovriaht 2007-2013 Slate of Florida.::Privacy Statement Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
Credit Card
Safe
9
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvCo3 EapiIlB... 10/17/2016
C-,
R W R W Building Consultants, Inc.
BConsulting and Engineering Services for the Building Industry
C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197
Florida Board of Professional Engineers Certificate of Authorization No.9813
Pi-oduct Evaluation Report Report I i'
ApH127,2015
Product Sub Category Manufacturer Product Name
Category
Plastpro Inc. Glazed Fiberglass Double Door
Exterior Swinging
Exterior Door 5200 W CENTURY BLVD. Inswing/Outswing
Doors Assemblies LOS ANGELES,CA 90045 "Impact"
(440)969-9773
Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc.and Lyndon F.Schmidt,P.E.(System ID#
1998)for Plastpro Inc.based on Rule Chapter No.61 G20-3, Method 1 D of the State of.Florida Product Approval,
Department of Business&Professional Regulation.
RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of the product named
herein.
Limitations:
1. This product has,been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code(FBC)structural requirements
excluding the"High Velocity Hurricane Zone".
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing
or stucco.
3.When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the FBC and does not
require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E1996 and
Section 1609.1.2.2 of the FBC.
4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction.
5. Site conditions that deviate from the details of drawing FL-17184.4 require further engineering analysis by a licensed engineer or
registered architect.
6. See drawing FL-17184.4 for size and design pressure limitations.
Supporting Documents:
1. Test Report No. Test Standard Testing Laboratory Siqned by
TEL 01391120 TAS 201-94,202-94&TAS 203-94 Testing Evaluation Lab.,inc. Lyndon F.Schmidt,P.E
TEL 01390454 ASTM E1886-05/E1996-06 Testing Evaluation Lab.,lnc. V.K.Wright
ASTM E330-02
2. Miami-Dade NOA Materials Testing
14-0423.16 Saflex®PVB Interlayers(Eastman Chemical Company)
3. Drawing No. Prepared by Signed&Sealed by
No.FL-17184.4 RW Building Consultants, Inc.(CA#9813) n r� r:^e d¢;s 4� Lyndon F.Schmidt,P.E.
is f
4. Calculations Prepared by • A Signed&Sealed by
Anchoring RW Building Consultants, Inc.(CA#9813)��0 'As Lyndon F.Schmidt,P.E.
� Eve.+ /fru o li p
5. Quality Assurance rr a`
Certificate of Participation issued by National Accreditation and a o r��
Management Institute,certifying that Plastpro Inc.is manufacturing products _ �, o t� "
within a quality assurance program that complies with ISO/IEC 17020 and-:') i:;t>» 3
a K, �� Lyndon F.Schmidt,P.E.
Guide 53. `E r; r- �s°•" FL PE No.43409
J°rtee4/27/2015
l� 1 a
Sheet 1 of 1 le-#o �6%i,
4.
4. M N
plastproM
5200 W. CENTURY BLVD.
LOS ANGELES, CA 90045
'yyc tNm
74.00" MAX. O.A. FRAME WIDTH--I i,��l'�c p1` �Y` o ,
I
'O Z o z fJ
NeEm 9oLa
J.a maa�i
GLAZED FIBERGLASS DOUBLE DOOR
INSWING/OUTSWING \' Zd
8 R
IMPACT Z
w w c?
Zo
GENERAL NOTES Uj o Uj_ �o
�� �w zo oZW
a 1. This product has been evaluated and is in compliance with the 5th '� Uj ' v v m
Edition(2014)Florida Building Code (FBC)structural requirements q ¢ /� /�
excluding the"High Velocity Hurricane Zone"(HVHZ). o 00 ow N w y
Z x 3 am A
2. Product anchors shall be as listed and spaced as shown on details. z� o �w
Anchor embedment to base material shall be beyond wall dressing oro— o o I a
stucco. O Lq a a
^+ rn m �
3. When used in areas requiring wind bome debris protection this product m
complies with Section 1609.1.2 of the FBC and does not require an
3 impact resistant covering.This product meets missile level"D"and
includes Wind Zone 4 as defined In ASTM El 996 and Section 1609.1.2.2 of
the FBC. tn
ry
o Z
4. For 2x stud framing construction,anchoring of these units shall be the W
same as that shown for 2x buck masonry construction.
GLAZED DOUBLE DOOR o
5. Site conditions that deviate from the details of this drawing require further
engineering analysis by a licensed engineer or registered architect. o
a ze
a �
t; �C
. w a
N Q J
o TABLE OF CONTENTS r m
MAX. O.A. GLASS DESIGN PRESSURE (PSF) Z
SHEET # DESCRIPTION SWING FRAME o 0
1 TYPICAL ELEVATION, DESIGN PRESSURES & GENERAL NOTES DIMENSION TYPE POSITIVE NEGATIVE z
El
z
� 2 PANEL DETAILS, COMPONENTS & GLAZING DETAIL 74.00" WE:02101112 �
w 3 HORIZONTAL CROSS SECTIONS OUTSWING X +50.0 —50.0 SCAM N.T.S. 9
s 4 VERTICAL CROSS SECTIONS 96.50" owo.BY: JK m
G1 CHX.BY. LFS 4
EF 5 BUCK & FRAME ANCHORING 74.00"
INSWING X +50.0 —50.0- ouvnHc NO.;
6 ASTRAGAL DETAILS N
7 BILL OF MATERIALS & COMPONENTS 98.00" FL-17184.4 n
SHEET 1 OF 7
B
c'
1 2 6 31 37 34 5 2 1 �`�•` "'
NI TERIOR :t� m •`'% n
[ n
...........
ZO
Ci
Ej
7 G1 EXT RIO cEm z ED m o
• �C+.a &ua 9 o`a
2�HORIZONTAL CROSS SECTION6 E oz
2 ' e o1
35.75" MAX. PANEL
WIDTH
5.16" F 3/4" GLASS z
a w
BITE 36 INTE 10 EXTERIOR z o='
1" OVERALL 1.385" 0 :
L 35 GLASS THK.
1/8" TEMPERED GLASS GI m V z_
1 AIR SPACE 34w w
\ 1/8" ANNEALED GLASS 31 F am
mm
to 0.090" SAFLEXO PVB v o a
_ = INTERLAYER a
21.00" w W Q 1/8" ANNEALED GLASS
MAX. x
D.L.O. o w 35 36 35 37
WIDTH J Q U
o a G1 GLAZING DETAIL o
34 °Mo 0CL
to
N N G
Li 2 o o in 1.584" N E o
O N to
0I U7
a \ —►{1.200"
2 J� �I 0.980"
a = 3 TOP RAIL z
OD
n
U') LoN H F
4.5" 000 v o
1.584" 0 5 6 -o u
1 7 _Z v
DATE 0210111 2 ?
zd 2 �1 HINGE & LATCH ��HINGE & LATCH STILE
DOOR PANEL STILE EDGE REINFORCEMENT 2 i 4sN.T.S. m
owG.BY: JK
S CHK.BY: LF$
2 BOTTOM RAIL �1 LOCK BLOCK DETAIL a
DRAWING NO.:
C\\VERTICAL CROSS SECTION FL_17184.4 a
� 2 SHEET 2 OF 7
d
4 4 1�4 MAX.
SHIM SPACE-1(TYP =Z
z' 'Ki O; o
o
11 11A , yz.
13 a 20 z
6J� a z n
n � UN••
Z o.U
n KXm mo
o.>' Vaiy � La
See a• p
Hardware 4
CZ
°
Table ° v°L
X X 2 0 Li a
3 0"
d z
3 3 23 O 23 J w
K (i cn
28
HORIZONTAL CROSS SECTION g W
m 3 SHOWN W/1X SUB–BUCK a� o
ch
U N
'q Li
O �E 2
1/4" MAX. a a
SHIM SPACE L
�m
z 3 4 0.15"(TYP.)
4 4 CTR—SNK
TYPICAL Y5
40 11 11A N
41 43 vo'. Z
a w O
INTERIO 13 22 13 >
ITE10 �' v
S a
0
C C 2
o "8
a ,+ �' NARDWAREfABIE
-2 MANUFACNRER MODEL
•c - .._.... a • a
> '�
D KWIKSET LOCK: SIGNATURE SERIES m0,Pp ^z �
W DEADBOLT: SIGNATURE SERIES V80) EXTERIOR
a LOCK: YHCOLLECTION 26 DATE 02101112
W YALE DEADBOM YH COLLECTION(8D SERIES) EXTERIOR 23 23 C 25
LOCK: "P'SERIES scAtF: N.T.S.
S SCHLAGE DEAOBOIT: 860/62 1 HORIZONTAL CROSS SECTION / 28 H K Dwc.er JK
[. 2�HORIZONTAL CROSS SECTION CNK.BY: LFS 3
3 3 DRAMNO NO.: N
n FL–7 7184.4 D
` sHEEr 3 or7
09
—
d
I
• R1Oients\Plaslpro,Inc PERMANENT\Flodda Product Approvals\FL-17184\C-Drawings\Current\FL-17184.3-S.dwg,4.4
i'
1/4" MAX.
SHIM SPACE
(TYP.) x
CTR-SNK '
TYPICAL v
tJI
G G
y _
• Z r O
N u.a O O
N
n .° ° y `
m
4v-
>1 X v
� O
X 0
b
e
1/4" MAX.
SHIM SPACE--{ Z
� N
m .. .. N 21
a>
n d 0 Z D
r r °
O a.° >
\ 'y
°n )
O O _
n D) m W .'16:.
Z 7C Z
O °
O �
�� F• m, /I
No.43409
�?7_rS �'0•'
x by x E g PRODUCT: Documents Pmpered
PLASTPRO INC. Lynd.n hmldt �• .......:•' ����
G
FIBERGLASS DOOR P.E. No. 43409
CO
—1 04 PART OR ASSEMBLY: VK /�BUILDING CONSULTANTS, INC.
Iv (n22 15 UPDATE 70 SIH ED. (2014) F13C JK VERTICAL CROSS SECTIONS J l�Y[r P.O. Box 230, Valrico, FL 33595
N NO DATE BY Phone No.: 813.859.9197
REVISIONS FBPE C.A. No. 9813
®
2012 R.W.BUILDING CONSULTANTS IND.
8" 4" .. ��p
8 ,
4.. 4" ...
� Xi0.
ro
e, �N•.7 z �rp�
to W fq. aTYP. Q c of M
Nz-
W/2X BUCK ASTRAGAL BOLT i�� r/rrr*•������``` o n aD z°
25 INSTALLATION 3/8" DIA. ti ; o x zo4
2X BUCK N W/1X BUCK THRESHOLD DETAIL \I� a Ea 9 m°ma
INSTALLATION DOUBLE DOOR 1�� LD a m a o a.
TYP. HEAD & ' ."�
JAMBS W/1X BUCK W/1X BUCKS`
INSTALLATION J N INSTALLATION E oz
2X BUCK-/ o vw fy
a. W/2X BUCK 24 44 25 W/2X BUCK o .,fid b�
INSTALLATION INSTALLATION
M 6
a �p w
Zo gU
2.094 oto
HEAD DETAIL m �z
N Y�
MASONRY MASONRY N DOUBLE DOOR
OPENING OPENING am m
p} U_ o
a
o F
a
"j P TYP. Of a
6 r03
U
BUCK ANCHORING FRAME ANCHORING m m
a N
N
23 J 1X/BUCK N
CONCRETEANCHORNOTES: INSTALLATION W0
I.Concrete anchor locations at the comers may be adjusted to maintain the min. w
iE
edge distance to mortar joints. N o m
23
2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to 22
maintain the min.edge distance to mortarjoints,additional concrete anchors N a
may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. 23 ❑ 27 a d
3.Concrete anchor table ' -
ANCHOR IGNN MlN CLEARANCE MIN CLEARANCE w/1 x 22
•4NG(!QR HINGE DETAIL BUCK w
0
0
TO MASONRY TO ADJACENT a a
•::S/k4�.. EMBEDMENT o
:.::.....:..:::................................ ..........:EL1GE.......... .......ANCHOR. ..:.; N o i
iAIrw 0 1/4" 1.1/4" 2" 4" 23 a 22 ro -Z o
a 26 N —02101112 ?
ELCO ® 1/4" 1.1/4" 1"' 4" P5 2X/BUCK sr ir, .N.T.S.
ULTRACON 23 INSTALLATION 22 M.BY: JK m'
EF fA1TW 3/16" 1-1/4" 3" 1.1/2" a
CHK BY. LFS
WOOD SCREW INSTALLATION NOTES: 23 STRIKE PLATE DETAIL LATCH & DEADBOLT DRAWNc No.: n
b9 spacing HINGE LOCATIONS LOCATIONS - ASTRAGAL FL-17184.4 N
1.Maintain a minimum 5/8"edge distance,1"end distance,&1"o.c.s aciof
n
wood screws to prevent the splitting of wood. HINGE DETAIL w/2X BUCK SHEEt 5 of 7
o — —
d
' • R.,\Clients\Plmtpro,Inc PERMANEN1\Flo6da Product Approvals\FL-17184\C-Drawings\Current\FL-171843-5.dwg.6A
0.5" 0.5"
2" w 2"
3.5" 0 3.5"
or 11.25" 11.25"
y 19.375" L19.375"
0 -21.375"-
z
21.375" 21.375"
31.875" 40.875" 31.875'
43.875" 43.875"
s
0 0
W to
A V
m tP
O
OD
W
o 0.573"
r Z
T
o i .
T~
�1 iD
(A
Z o
A
t3s
O O
m
CA
W W
_ II cn
—J -0.050" 0 0 2.880"
J
W O U)
�D W
D -
r
O
O
m
N
00.314"
N
O
r0*1 O
= o 0 0
AOnfA
O=rW O
_-• o
`O O
to v
V
i
/ No.43409
PRODUCT: Documents Prepared By: almcw
p o " n PLASTPRO INC. Lyndon F. Schmidt .....i/ •.2w
RBERGLASS DOOR P.E. No. 43409 /� S/ P��o
j o 2 0 rn ////111111��
PART OR ASSEMBLY: ry�/,,,//{/BUILDING CONSULTANTS, INC.
Iv . (n 1 04
2-27-15 UPDATE 70 5TH ED. 2014) FBC JK ASTRAGAL DETAILS J 1�Y4 P•O• Box 230, Volrirn, FL 33595
4� tv NO DATE BY Phone No.: 813.659.9197
REVISIONS FSPE C.A. No. 9813
0 2012 R.W.BUILOINo CONSULTANTS INC.
in
BILL OF MATERIALS C •m : ��
ITEM DESCRIPTION MATERIAL :$: o pi J_Z in
C 1/4" MAX. SHIM SPACE WOOD =6.1 * o; _- m
H 1/4" X 2-3/4" ELCO OR ITW PFH CONCRETE SCREW STEEL N:7 z F•�O� u a
J 3/16" X 3-1/4" ITW PFH CONCRETE SCREW STEEL n X01•' . E n=�
MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI rn �i'�• '•••••••••
K 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE o 2,22 '''�' 11 i pts��``` Z d m z0
L 2X BUCK SG >= 0.55 WOOD o o
M 1X BUCK SG >= 0.55 WOOD p Em z m m v
N 1/4" X 3-3/4" ITW PFH CONCRETE SCREW STEEL \[ og
5 0 on.
P 1 4" X 2-1/4" ITW PFH CONCRETE SCREW STEEL 5 mt
da�
DOOR SWEEP
1 HINGE & LATCH STILE EDGE COMPOSITE 52 o C°
2 HINGE & LATCH STILE REINFORCEMENT WOOD 0d
3 TOP RAIL COMPOSITE o 310.
4 BOTTOM RAIL COMPOSITE
5 LOCK BLOCK WOOD
6 DOOR SKIN (0.069" THK.) PLAST PRO/NANYA Fy= 11,063 PSI FIBERGLASS (
ncl
7 FOAM CORE POLYURETHANE 'jo aZ
11 JAMB FINGER-JOINT-PINE SG >= 0.42 WOOD
_o �w
11A POLYFIBER JAMB POLYFIBER - a: ¢o
13 WEATHERSTRIP FOAM N 0 L�4.562" �{ ag m `moo
o
22 8 X 3" PFH WOOD SCREW STEEL ` 4.562"�
a 23 #10 X 3/4" PFH WOOD SCREW STEEL cm
24 #10 X 2-1/2" PFH SMS STEEL ry o
11 25 #10 X 2-1/2" PFH WOOD SCREW STEEL0 12
26 LATCH STRIKE PLATE STEEL
27 DEADBOLT STRIKE PLATE STEEL 11 JAMB m
28 4" HINGE STEEL 11A
POLYFIBER JAMB
31 1 ODL LITE FRAME ALUMINUM
34 #10 X 1-3/4- PFH WOOD SCREW STEEL
35 GLAZING COMPOUND REDI-SEAL BY ODL, POLYMERIC FOAM P MERIC FOAM
0 36 STRUCTURAL SILICONE DOW #995 SILICONE N z
37 SCREW PLUG - 0
40 ASTRAGAL 6063-T5 ALUMINUM BY DLP ALUMINUM
41 CONCEALED STIFFENER 6063-T6 ALUMINUM BY DLP ALUMINUMin
42 SLIDE BOLT ROD STEEL voi -4.56"-
43
4.56"43 #8 X 2" PPH WOOD SCREW STEEL `V a
a 44 ASTRAGAL STRIKE PLATE @ HEAD STEEL 4.563" j
45 OUTSWING THRESHOLD BY DLP ALUM. WOOD
51 INSWING THRESHOLD BY DLP ALUM./WOODa_
0 N a
52 DOOR BOTTOM SWEEP VINYL N o
OUTSWING THRESHOLD �1 INSWING THRESHOLDo
o
"z
DATE 02/01/12 b
G D
SCALF- N.T.S.
Dwc,BY.- JK m
s CHK.ar: LFS 3
g DRAWWG NO.:
N
FL-17184.4 c
a SHEET__L OF_L
f
d