HomeMy WebLinkAboutEngineering i c KUHN ENsINEERING [STRUCTURAL ENGINEERING] Certificate ofAuthorization #30464 i Product Evaluation Report Min. 29 Ga. AG Roof Panel Over,15/32 Plywood Florida Product Approval# 19041.1 Florida Building Code 2014 (5`h Edition) Per Rule 61G20-3 Method: l-D f Category: Roofing Subcategory: Metal Roofing Compliance Method:61G20-3.005(1)(d) Zone: Non HVHZ I � Product Manufacturer: 15L Coast Metal Roofing Supply 186 State Road 207 P.O. Box 177 East Palatka, FL 32131 Engineer Evaluator: �.�'� N�EL;S••/{�'�., Daniel S. Kuhn, P.E. ���;' 1C NS'�'Sy', Kuhn Engineering LLC. FL PE#75519 ;* No. 75519 FL Evaluation ANE ID: 10743 .13% STATE OF Validator: Locke Bowden, P.E., FL#49704 ;Fsi• O FI I'D P,.•�� C�� • 9450 Alysbury Place I , 0NAL EN .��� Montgomery,AL 36117 �''1 1 1 1 1 I t /01281ZD/S I Contents: Evaluation Report: Pages 1-4 I KUHN ENGINEERING EST RIJCTU PA.L ENG IN EEP;NGj Compliance Statement: The product as described in this report has demonstrated compliance with the FBC 2014(5t' Edition),Sec. 1504.3.2 and 1504.7, Product Description: AG Roof panel, Min.29 Ga.Steel,36"Coverage,',through fastened roof i panel over minimum 15/32"_plywood decking. Non-structural application. i Panel Material/Standards: Material: Minimum 29 Ga.,ASTM A792 Aluminum-zinc coated steel i i. (Optional Paint Finish) Steel Grade: Min.Grade 80 Corrosion Resistance: Panel material shall comply with FBC 2014,Sec. 1507.4.3. Panel Dimension(s): Material Thickness: 29 Ga. Minimum Width: 36"(Coverage) Rib Height: %" Major Rib at 9"o.c. Panel Seam: Lap sealant must be used for slopes less than 3:12 Panel Rollformer: Cidan Machinery, Inc. Panel Fastener: #10-15 X 1-1/2" HiLo Woodgrip w/sealer washer or approved equal 1/4" minimum penetration through plywood. Corrosion Resistance: Per FBC 2014,Sec. 1506.6'and 1507.4.4 i Minimum Slope Range: Minimum slope 1/2:12 and shall comply with FBC 2014,Sec.1507.4.2 and 1504.7,as well as in accordance with Manufacturer's recommendations. Underlayment(Optional): Shall comply with Florida Building Code 2014,Sec. 1507.4.5.1 and 1507.4.5.2. Panel Substrate: Minimum 15/32" Plywood. Plywood Support: Roof framing must be spaced at 24"o.c maximum. Design of roof rafters/trusses, plywood,and plywood attachment/nailing pattern are outside the scope of this report. Kuhn.Engineering, LLC. 954.552.4500 FL#19041.1. www.Kuhn Engi neeri ng.com info@KuhnEng-ineering.com Page 1 of 4 I KUHN ENSINEERI" NS [STRUGTURIA L E NG IN EERINr?: Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Installation: Install as per manufacturer's installation instructions and recommended details. Refer to Table"A" below for fastener pattern and spacing. Table Maximum Total Uplift Design -78.5 psf* -108.5 psf Pressures: Fastener Pattern: 9"-9 -9 9" 6I',-3"-6"-3"-6"-3"-6" Fastener Spacing(max.): 24"o.ci 24"o.c. *Allowable(ASD)Design Pressure Includes al FS=2.0!' i -Installation over Existing Shingles(Optional): I AG panel may be installed over a single laver of'existing roof shingles in accordance with the standards listed in FBC 2014,Section 1510.3. Attach panels directly over existing shingles and'fasteri into the decking i material with a minimum 1/2" penetration through plywood.All five items listed under Sec. 1510.3 must be checked and verified. Design Procedure: Based on the dimensions of the structure,appropriate wind loads are I determined using Chapter 16 of the FBC 2014 for roof,cladding wind loads.These component wind loads for roof cladding are compared to the allowable pressures listed above.The design professional shall select the appropriate erection details to reference ini his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover.Support framing must be in compliance with FBC 2014(51h edition) Evaluation Report Scope: The product evaluation is limited to co pliancewith the structural wind load requirements of the FBC,as relates to Rule 61G20-3.001. I , Limitations and Conditions of Use: 1. Scope of"Limitations and Conditions of use"for this evaluation: This evaluation report for"Optional Statewide!Approvals"contains technical documentation,specifications and installation method(s), which include"Limitations and Conditions of Use"throughout the Kuhn Engineering, LLC. 954.552.4500_ FL#19041.1 www.KuhnEngineering.com info@KuhnEngineering.com Page 2 of 4 i KUHN ENGINEERING [ST7;LG i Ll z ,L E1\1GItlEERI'NGa I report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004,the Florida Building Commission is the authirity to approve products under "Optional Statewide Approval". I 2. Option for application outside"Limitations and Conditions of Use": Rule 61G20-3.005(1)allows engineering�analysis'for"project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the,Code".Any modification of the product as evaluated in this repotand approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. 3. This product is not for use in the High Velocity Hurricane Zone I sections. Performance Standards: The product has been tested in accordance with: • UL 580-94—Test for Uplift desistance of Roof Assemblies— with Revisions through February 1998 • UL1897-98—Uplift Test for Roof Covering!Systems I Reference Data: Tests performed by Force Engineering&Testing, Inc. (FBC Organization#TST-5328): • UL 1897-98—Uplift Test for Roof Covering Systems Test report No.384-0030T-10A;B/593-0030T-10A, B (Dated 03/29/10) • FM 4471,Sec.5.4 Foot Traffic Resistance Test Report No.384-0030T-10E/593-003OT-10E (Dated 03/29/10) j Certificate of Independence by: • Daniel S. Kuhn, P.E. (FL#75519)at Kuhn Engineering, LLC. (FBC Organization#ANE IDI 10743) , Test Standard Equivalence: 1. UL 580-94 test standard is equivalent to UL 580-06 test standard. 2. UL 1897-98 test standard is equivalent to UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. I Kuhn Engineering, LLC. 954.552.4500 FL#19041.1 www.KuhnEngineering.com info@KuhnEngineering.com Page 3 of 4 I i • 7 I i. KUH- N ENGINEERING CSTRJ0TUR.4:L EI,GIJ�JEER ING7 Min. 29 GA. AG Panel Load Table Over Plywood Building having a Roof Mean Height<_20'-0"; Roof Slope 1/2":12"—6":12"Gable Roof Wind Speeds 100-140 mph, Exp.C, Risk Category Il,.based on FPC 2014 29 GA. AG PANEL FASTENER SPACING WIND SPEED(mph') ZONE FASTENER SUBSTRATE 100 110 120 1301 140 ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER I SPACING SPACING SPACING iSPACING SPACING 15/32" ZONE 1 #10-15 X 1-1/2" PLYWOOD 24"TYPE 1 24"TYPE 1 24"TYPE 1 24"TYPE 1 24"TYPE 1 ZONE 2 #10-15 X 1-1/2 15/32 24 TYPE 1 24 TYPE 1 24 TYPE 1 24 TYPE 1 24 TYPE 1 PLYWOOD ZONE 3 #10-15 X 1-1/2 15/32" 24 TYPE 2F24- PE 2' 24 (TYPE 2 24 TYi 11 PLYWOOD °� I PE 2 24°'TYPE 2 Notes: I i 1) Panel Description:AG panel, Min.29 GA.,%"Tall Rib at 9"o.c.,36"Width 2) Panel Fastener:#10-15 x 1-1/2" HiLo Woodgrip w/sealer washer or equivalent 3)Panel Rollformer:Cidan Machinery, Inc. 4) Maximum Allowable Panel Uplift Pressures based on UL 580/UL 1897 testing;by Force Engineering Test report#38470030T-10A,B/593-0030T-10A, B: 78.5 psf at 24"o.c.Type 1 Fastener Pattern 108.5 psf at 24"o.c. Type 2 Fastener Pattern 5)Substrate: Min. 15/32"thick plywood. 6) Existing Shingles(Optional): Panels may be attached over single layer of existing shingles as per requirements listed in this report. CONTINUOUS LAP SEALANT FOR USE ON SLOPES LESS THAN 3:12 9" 9" 9" 9" #10-15 X 1-1/2"HILO WOODGRIP I OR EQUIVALENT SPACED AT 24"oc TYPE 1 FASTENER PATTERN I CONTINUOUS LAP SEALANT FOR USE ON SLOPES LESS THAN 3:12 ' 6" 3" 6" 3" 6" 3" 6" 3+_ I ' #10-15 X 1-112"HILO WOODGRIP, OR EQUIVALENT SPACED AT 24-0c TYPE TYPE 2 FASTENER PATTERN I i ' I Kuhn Engineering, LLC. 954.552.4500 FL#19041.1 www.KuhnEngineering.com info@KuhnEngineering.com Page 4 of 4 i, � I