HomeMy WebLinkAboutProduct Approval 4/28/2016 Florida Building Code Online
rim
'brld3?Depaamientl SCIS Home i_Log In User Registration j Hot Topics Submit Surcharge Stats&Facts 1 Publications FIBC Staff I BCIS Site Map j Links j Search
Business/�, �
2Pr-
Product
Product Approval
Professional aUSER:Public User
Regulation
=10711111IAl 1l�# Acoroval Menu>Product or Application Search>Application List>Application Detail
d FL# FL10674-R11
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
1
i
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
it
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscornig.com
I
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer '.I
Evaluation Report- Hardcopy'Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/20/2017
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate'ofIndependence FL10674 R11 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 i' 2009
ASTM D3462 !i 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr app OU.aspx?param=wGEVXQwtDgtBNbEY5Vp/p2boQTp/o2b6w7ahReglCQ8ucR6ixEAOdgbcUi3osQp/`3d`/o3d 1/2
412812016 Florida Building Code Online I
I
Product Approval Method Method 1 Option D
Date Submitted 10/15/2015
Date Validated 10/19/2015
Date Pending FBC Approval 10/20/2015
Date Approved 12/15/2015
Date Revised 04/18/2016
Summa of Products
FL# Model,Number or Name Description 1
10674.1 Owens Corning Asphalt Roofing 3-tab, 4-tab, 5-tab, laminated, starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10674 R11 II 2015'A0 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R111.odf
Impact Resistant:N/A Verified By: Robert].,M. Nieminen PE- 59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other:Refer to ER, Section 5. Evaluation Reports
FL10674 R11 AE 2015110 FINAL ER OC ASPHALT
SHINGLES FL10674-Rli.Ddf
Created by Independent Third Party: Yes
Back Nest
j
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:85U-487-1824
'I
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. :: Privacy Statement::'Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in respons�el to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide'the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses'ire public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter
455,F S.,please dick here.
Product Approval Accepts: I'
am
eChecY ,i 1
securitvm i.xmc I
NNE
it
�I
i 6'I
I
I
https://www.floridabuilding.orglpr/pr_app dtl.aspx?param=wGEVXQwtDgtBNbEY5Vg/o2boQTg/o2b6w7ahReglCQ8ucR6izE4OdgtxUj3osQp/o3dp/o3d 22
�l
I'
I
• �I
Y`
• �, � EXTERIOR RESEARCH&DESIGN, LLC.
i zti f Certificate ofAuthorization#9503
z r
353 CHRISTIAN STREET UNIT#13
if ER® I OXFORD,CT 06478
PHONE:(203)262-9245
l I FAX:(203)262-9243
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R6
One Owens Corning Parkway FL10674-R11
Toledo,OH 43659 Date of Issuance:02/06/2012
Revision 6: 10/15/2015
SCOPE:
i�
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules' and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition (2014)Florida Building Code,sections noted herein.
I
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named prodluct(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the protluct change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P E. if the product changes or the
referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its .
distributors and shall be available for inspection at the job site at the request of the Building'Official.
i
This Evaluation Report consists of pages 1 through 7.
Prepared by:'Z
stttttrrn,,, I'I
41
..a1L;.r r.:.•
Robert J.M. Nieminen P.E. N�� Thefarsimilesealappearing was authorized byRobert Nieminen,
�'' %� �', P.E.on 10/15/2'1 1015.This does not serve as an electronically signed
i lJi��nutattU
Florida Registration No.59166,Florida DCAANE1983 document Signed,sealed hardwpies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinityjERD does not have, nor does it intend to acquire or will it acquire, a financial interest`in any company manufacturing or
distributing products it evaluates. i.
2. Trinity IERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any ay, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
i
i
1
iINI� TY ;ERS
ROOFING SYSTEMS EVALUATION:
I
1. SCOPE:
Product Category: Roofing I'I
'Sub-Category: Asphalt Shingles I
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is[subject to' the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
fi
Section Prope Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008
3. REFERENCES:
Entity Examination Reference i Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 I 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 I 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 j 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs a Various
UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic*and Supreme®are fiberglass reinforced,3-tab asphalt roof shingles!
4.1.2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles. '
4.1.3 Devonshire TM are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration', TruDefinition' Duration®, Duration' Premium Cool, TruDefinition' Duration' Designer Color
Collection,Tru Definition'Oakridge, Oakridge'and WeatherGuard'HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Berkshire® Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant,;WeatherGuard' HP Hip & Ridge
Shingles, ProEdge Hip &Ridge Shingles and DuraRidgell Hip & Ridge Shingles are fiberglass reinforced,hip
and ridge asphalt roof shingles.
4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nie ninen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that�purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to cure Int Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6
Certificate of Authorizatfon#9503 FL10674-Rll
Revision 6:10/15/2015
Page 2 of 7
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158, Class H, indicatingithe shingles are acceptable for
us in all wind zones up to Vasd=150 mph(V,,h= 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Stant'r Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.611 to ASTM D3161, Class F, indicating the
shingles are acceptable for us in all wind zones up to Vasd= 150 mph (V„It:= 194 mph). Refer to Section 6
for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations.
Contact the shingle manufacturer for data specific to each shingle:
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold cu'rlrent Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3, per FBC Sections 1507!2.3, 1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four(4) nails per shingle in accordance with FBC Sections 15072 or R905.2, with the following
exceptions:
➢ Berkshire'shingles require minimum five(5) nails per shingle.
➢ WeatherGuard HP shingles require minimum six(6)nails per shingle!
Devonshirelm shingles require minimum six(6)nails per shingle.
> Starter Strip Shingle and Starter Strip Plus require minimum-five(5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, 'special methods of fastening are
required. Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Felt underlaymeni Deck Feb underlayment I Deck adbe eWeathertod
Self-adhered ^il undorlayment
WeatherLock"
undertayment
Drip edge
edge - Drip edge
Drip—
edge
Nail located Nails located
2'-3•from eave
2"-3"from eave
Install first Selfaealing adhesive ' Self-sealing adhesive
Starter Strip oskioned along eave Instal fiat Starter Strip Plus positioned along eave
p
shingle with \ with 6'removed \
6"removed
Starter Strip shingle overhangs eaves and takes'A"-%' StarterlStrip Plus overhangs eaves and rakes t/4•-314•
Exterior Research and Design,I.I.C.g , Evaluation Report 037940.02.12-R6
Certificate of Authorization#9503 FL10674-Rll
Revision 6:30/15/2015
Page 3 of 7
TRINITY!ERD
6.2.6 Minimum Nailing—Classic® &Supreme:
i'
Normal Mansard or Area para Normal Mansard or Area pars
Wind Areas High Wind desvenes y Wind Areas High Wind desvanes y
Area para vientos normales Areas vientos fuertes Area para vientos normales Areas vientos fuertes
i
�^�t^ iA) ��,'" j T' z• (B) z^ �" �" (A) r�• Z" (B) r.z"
tz� tz t
t
5"Exposure 5 5/8"Exposure,
Exposici6n ExposicMn
i
6.2.7 Minimum Nailing—Berkshire®:
i
i
Sealant sUip Sealam strip
La taa de se8ada Ce Etre de seJfadar
i'
t" 8 V2" 9 VP 9 YC 8 Vt YC 8 YT }
'I
r
k
2. AsphaR rooting cement
COMM de(echodeastafto
6.2.8 Minimum Nailing—Devonshire'":
7 <y
—� Nails
rr a .r r r r
f r 3.1
Nails Ten 1"Sp is of Asphalt Roof Cement
I�
ii
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-116
Certificate of Authorization#9503 FL10674-R11
Revision 6:10/15/2015
Page 4 of 7
I
i
J TRINITY ER®
6.2.9 Minimum Nailing — Duration°, TruDefinition® Duration, Duration® Premium Cool & TruDefinition
d
Duration Designer Color Collection:
I,l rdarsard and Steep Stope,
4 Nal Pattern 6Nal WentAweensureNaa®
Esquema de 4 davos Pattern I' area andtop or Mod.
o Esquema g um opemisrde�
Surejlailttstening area widtha vdasf ida mta at
Area dedawsSureNail0 de6clavos a dreaswenad�ybpato
—'� srpznaditraata:
SureNaia <li A SurtNaiP
1' 1" �sreru � tasten¢rg
ateawidN ` arm rvid[h
_ 12' 12•—� _ Arasda 7" \1 Ae8a tea
Sur
eNaOm � Si t'aif�
LK
5va"Exposure Nails6%"Exposure '
UAp+rlg.doexposid6n Claws 65/apulg.deexposiei6n
5=la Exposure Nails 53'd'Exposure
55%pulg.de exposivitin Clavos 551apulg.deexposidM
6.2.10 Minimum Nailing—Tru Definition'Oakridge®,Oakridge":
4 Nail Pattern 6 Nail Pattern
Esquema con 4 clavos Esquema con 6 clavas
r r ,
12.
r r
I
5 518 Exposure Nails 5 518"Exposure Nails
Exposld6nde6618pu1g Claw Exposki6nde5618pu1g. 5 5/8"Exposure Clavus 55M'Exposure
Exposiddn de 5518 pulg Exposidrin de 6 6/8 pu1g.
6.2.11 Minimum Nailing—WeatherGuard® HP:
d
I'
1' 1 Binglo BI018 View
I� ZVrib il/Eni/
4.
Gwir inMein db4 in
iJ
6.3 Hip& Ridge Shingles:
6.3.1 Installation of Berkshireo Hip and Ridge Shingles, High Ridge, Hip&Ridge with Sealant,WeatherGuarde HP
Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply,with the manufacturer's current
published instructions, using four (4) nails per shingle. Installation of buraRidgeTel Hip & Ridge Shingles
shall comply with the manufacturer's current published instructions,using two (2) nails per shingle. Refer
to Owens Corning published information on wind resistance and installation limitations, including the use
of hand-sealing for wind warranties.
Exterior Research and Design,LLC. Evaluation Report 037940.02:12-R6
Cert4kate of Authorization#9503 FL10674-R11
Revision 6:10/15/2015
Page 5 of 7
i,
k` . TRINITY!ER®
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire°Hip&Ridge and High Ridge:
Fig.1 4 Fig.2
t— Plevdiling Wnd \ �
Dtreribn A l TopMew a SideUex
I Nads---�—_�. \ A\` Nails Nails
Top=ale.
A I I j j I
I p t I I I I
g.. Ei
Exposure m
uI
i I
I '
I
iI
II
6.3.4 Minimum Nailing—Hip &Ridge with Sealant:
am Fig. 2 -High Wind Fastening Rattaln
(4 IUalls)
rim Shingle
nd Discard 2,,
Ent 1„ 1„
Sealant -�
Strip 12'"I
' Fastening S5/r' S"Exposure
�+istance � '
12 "
6.3.5 Minimum Nailing—WeatherGuard® HP Hip and Ridge:
Fig.C Hip&Ridge,Shingle Fastening
Fig.A _44� TopwoVi
Pmvalltng Wind
Dlfectbn � p
Halls A i
44
A i i Nails Nails
p i i T'
2" 2"
A I
P I I I I
�—.po5
sum +1 �
S Exposure �
Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R6
Certificate of Authorization#9503 FL10674-R11
Revision 6:10/15/2015
Page 6 of 7
"I
l
TRINITY ERIC
6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard
Wind DirectionFastening
Sealant Strip Pattern
6°Exposure • »� �' !' yf^� I't'
12° Sealant
Fasten Th° 7711
I ,6"ExposureI
CoverEzposed 1 1 �I 1
Fasteners with
Roof Cement I�-1 12°-:
,II
6.3.7 Minimum Nailing—DuraRidge"'Hip&Ridge Shingles:
Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens
Corning published installation instructions for their minimum requirements.
Proraifng Wind Diraedon lop V ew
Dlraa�6A6.1antadlYfllC � Vlan
Diracdon dol viaiw pVisa apI'IH
clou
r
Cv.
Mous Im 7 I
�I�
` y
1 l , 4
alar
la.0
' I I
k p
I4 127--1
Ili
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
I
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.';
i
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements. d
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625; (414)248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT-
I
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6
Certificate of Authorization X/9503 FL10674-R11
Revision 6:10/15/2015
Page 7 of 7
I