Wind Load Calculation
Castle Impact Windows FACTORY DIRECT SINCE 1969 -- COMPLETE HURRICANE PROTECTION SOLUTIONS 7089 Hemstreet Place West Palm Beach,FL 33413 800.643,6371 Property Information Building Information Owner: MACALUSO,ROBERT Wind Zone: 160 MPH. Address: 6495 ALMEMENDRA STREET Exposure Category: C FORT PIERCE,FL 34951 Minimum Building Dimension: 30 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) IFElevation(ft) Pressure(psf) Pressure(psf) 1 Int 52.75 54.25 7 32.0 -34.8 2 Int 53 55 7 31.9 -34.8 3Int 53.25 55 7 31.9 -34.8 4 End 95.25 83 7 29.8 -37.4 5 End 227 83 7 27.9 -33.6 6 Int 74 55 7 31.2 -34.1 7 Int 26.5 38.5 7 33.5 -36.3 8 Int 26.5 38.5 7 33.5 -36.3 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code. Page 1 of 1 Customer: MACALUSO WorkOrder Number: 09162016006 N0301 Sales Engineer- Wall Opening Opening Shutter Shutter Anchor Sections Opening# ing Pressure Width Height Width Height Spacing Opening# 1 1 -34.8 52.75 54.25 52.75 54.25 9"o.c. 1 9"o.c. 2 2 -34.8 53 55 68.75 60 9"o.c. 1 9"o.c. 3 3 -34.8 53.25 55 69 60 9"o.c. 1 9'b.c. 4 4 -37.4 95.25 83 113.375 88.5 9'b.c. 1 9'b.c. 5 5 -33.6 227 83 257.125 88.5 9"o.c. 1 9"o.c. 6 6 -34.1 74 55 89.75 60 9"o.c. 1 9"o.c. 7 7 -36.3 26.5 38.5 40.25 43.5 9"o c. 1 9"o.c. 8 8 -36.3 26.5 38.5 40.25 43.5 9"o.c. 1 9.0.C.