Loading...
HomeMy WebLinkAboutEngineering :.. FILE COPY FLS. A ENGINEERING & TESTING, INC. Phone: (866) 781-6889 *Fax: (866)'78 4-8550 w`vw.floridaengineeringandtesting.com 250 S.W.13"'Avenue R E C E I VL:-D OCT 2 5 20116 Pompano Beach,FL 33069 DATE: 10/21/16 JOB ORDER#: 16-3252 CLIENT: Freedom Roofers,LLC ADDRESS: 868 Noa Street Fort Pierce, FL 34982 PROJECT: Allen Residence Sloped Roof Deck(2) ADDRESS: 17 Nettles Island Blvd. Jenson Beach,FL FBC 2014/ASCE 7-10 DESIGN PRESSURE CALCULATIONS Proiect Information: Mean Height= 18' &20' Exposure: D Basic/Ultimate Wind Speed: Vi1t=170 mph Length= 31' &23' Category: II Nominal Wind Speed: Vasd=Vuit*�0.6 Width= 23' &21' Slope: 3/12 = 14.0° (asd=allowable strength design) Parapet Wall: N/A Residential KZ= 1.08, Kzt= 1.0,Kd=0.85 Note: The most conservative dimensions were utilized for the design calculations below. Design Calculations: Velocity Pressure: q=0.00256*KZKztKdV2 Velocity Pressure („it): q=0.00256(1.08)(1.0)(0.85)(170)2= 67.92 psf Velocity Pressure (md): q=0.00256(1.08)(1.0)(0.85)(170* 0.6)2=40.75 psf Width of Pressure Coefficient: 0.1(23) = 2.3' 0.4(20') = 8.0' } use: 3'0" Effective Wind Area: <1 W External Pressure Coefficient: Internal Pressure Coefficient: 1) GCP 1 = -0.9 1) GCP; = 0.18 2) GCP2 = -1.7 3) GCP3 = -2.6 Design Pressures Based on Vasd: 1) Field P1 = 40.75%-0.9)[(-0.9)—(0.18)] = -44.0 psf 2) Perimeter P2 = 40.75*[(-1.7)—(0.18)] = -76.6 psf 3) Corners P3 = 40.75*[(-2.6)—(0.18)] =-113.3 psf iiQ u Qrcality)115� ASG Jlssnrdnce Page 2,10/21/16,Job Order#16-3252 Freedom Roofers,LLC-Allen Residence IEP A Sloped Roof Decks(2) 17 Nettles Island Blvd.;Jenson Beach,FL: Attachment Requirements: Based on the requirements of Florida Product Approval # 16651.2 R2, Table A with maximum design pressures of-52.5psf and 116.0psf; the following are our recommended fastening patterns to attach the 16" wide Aluminum GulfLok Roof Panel to the minimum 15/32 plywood decks (fastened to structural supports per product approval) utilizing #10- 12x1" Pancake Type A fasteners through panel slot with 1/4" minimum penetration through plywood at the following fastener patterns and fastener spacing: Zone(s) Field (1) Perimeter(2) & Corners (3) Max. Total Uplift -52.5psf -116.Opsf Design Pressure Panel Slot Fastener 5-3/16" o.c. 5-3/16" o.c. Spacing Sealant on Male Rib NOT USED REQUIRED Notes: Corners and perimeter (edge, hip, & ridge) area dimension shall not be less than a = 3'0" (Zone 2: Perimeter is a 3'0" wide strip, Zone 3: Corners are 31 0" x 31 011 ) Our engineering attachment analysis is limited to uplift resistance only, therefore, it does not include waterproofing or aesthetic concerns as applicable. Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty(as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2014 Edition. Wind load calculations based on ASCE 7-10, FBC 2014 and information provided by client. Client is responsible for verifying existing conditions as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative.) or a building department inspector to verify compliance feel ications Sincerely,' - a;�. tiC, Mar1CA_. Mesiario�,-P:E. . Florida-E ig neeriing.8.T, sfmg, Inc. Florida-Reg:No:.48202E? Certificate-of-Author zation No. 6923