i FLORIDA PRQDUCT APPROVAL N4: 11f.5'i.2.R2
_..,.,
Product Evaluation Report
GULF COAST SUPPLY& MANUFACTURING, LLC.
0.032" Aluminum Gul&011 " 16°' Wide Roof Pavel over 75132'° plywood
Florida Product Approval #11651.2 R2
Florida Building Code 2014
Per Rule 61 G20-3
Method: 1 -D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 61G20-3.005(1)(d)
NON HVHZ
Product [Manufacturer:
Gulf Coast Supply 8t Manufacturing, LLC. ��►,����
°° P AEL S
14429 SW 2nd Place, Suite G30 �'..,. . •. .. , ,S,
Newberry, FL 32669 ��G E NSF•.'L
*; No. 75519
Engineer Evaluator: �!-
Dan Kuhn, P.E. 475519
11 STATE OF .��:
Florida Evaluation ANE ID: 10743 ��,�.•
FS• ORiOP.•���':
S"ONa'L �NCa
Validator: 1,11111110%
%
Locke Bowden, P.E. #4.9704 o,613012015
9450 Alysbury Place
Montgomery, AL 36117
Contents:
Evaluation Report Pages 1 - 5
FL#11651.2 R2•JUNE 15,2015
.r
qL
F'
r
¢ l e i
I t•y',f Ac{a�: i{ 7 l_'-_�y) w,� {L 5t....��-..'_�.i.- _._,.__,. 1..-___.w._..t..-_... ..
`JUPPLY & MANUFACTURING
W
tr
LF
� �, � i t
7
s t .t 3y r�-�f`°7 t,Vf{,i4 '�g���} ''3�I ��1f 3'*': t. ie``: +ro r"yyy`.1l h fii {. ` Y •{Vkk`x , J3.= i imp 4`\ r ^
� '�' S•_7 ... �... s l .A'Y3f.„.,l t �w.._.•! "_ /,i,ti i A1�Tt„si� �..�I .} .Y t'_�2 J 7 � et,*..t t;S t, ��d.f�.�Iryt
4
FLORIDA PRODUCT APPROVAL NO. '1155'!.2 R”
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2.
Product Description: GulfLokTI1, 7/8" Nailstrip Roof Panel, Minimum 0.028" Aluminum, Maximum 16"
Coverage, Roof panel restrained with fasteners into minimum 15/32" plywood
decking. Non Structural application,
Panel Material/Standards: Material: Minimum 0.028" Aluminum conforming to Florida Building Code 2014
Section 1507.43.
Paint Finish Optional
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2014, Section 1507.4.3.
Panel Dimension(s): Thickness: 0.028" Minimum
Width: 16" Coverage Maximum
Female Rib: 7/8" Tall
Male Rib: -3/a" Tall Rib with Slotted Strip
Panel Seam: Snap Lock
Panel Seam Sealant: Titebond Weathermaster Metal Roof Sealant apply fa"-5/16" diameter continuous
bead on the male rib for Assembly B only.
Panel Fastener: Through Panel Slot: (1)#10-12x1" Pancake.Type A
%" Minimum Penetration through Plywood.
Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4
Substrate Description: Minimum"/3 2" thick, APA Rated plywood over supports at maximum 24" O.C.
Design of plywood and plywood supports are outside the scope of this evaluation.
Must be designed in accordance w/Florida Building Code 2014.
Design Uplift Pressures: Table"A"
Panel.Assenlbly', A. ' Bl
Maximum Total Uplift Design Pressure 52.5 psf 116.0 psf
Panel Slat Fastener.Spacing. 5?/16` O:C. ; 5'3h6' 0.C.
Sealant on Male Rib NOT USED USED
*Design Pfessure'inciddes a Safety Factor,=2,0.
FL#11651.2 R2•JUNE 15,2015
p V.•,, 'f !ham V 'i , JY''-
t i
__[� i � -. . ty._„ `,,
t
SUPPLY & MANUFACTURiNG
;
d
l, t LF, --
�.'l {L'_ � efi �Sd1,i_. 13 k" 1 t C ter Ltf{jj -- p t
FLORIDA-PRODUCT APPROVAL 1[tii0, 19f5.1 2 .R2
Code Compliance: The product described herein has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2014, as relates to Rule 61 G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
• UL 580-06 -Test for Uplift Resistance of Roof Assemblies
• UL 1897-04- Uplift Test for Roof Covering Systems.
Reference Data: 1. UL 580-941 1897-98 Uplift Test
Force Engineering &Testing, Inc. (FBC Organization#TST 5328)
Report No. 117-0337T 10 Dated 03107/2011
2. Certificate of Independence
By Dan Kuhn, P.E. (FL# 75519)Q Kuhn Engineering, LLC
(FBC Organization #ANE ID: 10743)
Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard,
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test
standard.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61 G20-3.005(3)for
manufacturing under a quality assurance program audited by an approved quality
assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including
Section 1507.4.2 and in accordance with Manufacturers recommendations.
Installation: install per Manufacturer's recommended details.
Underlayment: Shall comply with Florida Building Code 2014 section 1507,4.5.1 and 1507.4.5.2.
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear Diaphragm values are outside the scope of this report.
FL# 11651.2 R2•JUNE 15,2015
71=51AI 011 i 11111r
f
' __ _--_:_.i �,I '•..a t_ !'F?S�Itl S.=.".EkvS.�:.__�_.�..,..a-,_..__:.-:'�..__-_-, { �j:.;,_.a. f.�'2,_'�.�.{�..+��t?..3��i.�3, _n�^..._,.._..., k ...il_�_ �..-,o'__ _ -__ .._'-__ , _._.__'. _ ___ __ ____ __ _..
GU-/If
SUPPLY & MAN 1)FACT URING
a:+ -
,
77
°V ,
��a
I FtLOR{DYA PR"OD.U`C�T APPR=OVAL '�O: 9,1651 2 R2
Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must
at a minimum meet those listed for the applicable wind zone. For all roofs outside
the parameters listed on the load table, design wind loads shall be determined
for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10
using allowable stress design.The maximum fastener spacing listed herein shall
not be exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this
product in High Velocity Hurricane Zone.
FL#11651.2 R2•JUNE 15,2015
e:.
i2
Y 1
..
(((' .}•3' hs is )(' 7 I [Jy L'Yi
i ..," 1sn "aC' .3'��3x t at +f,`1j f•ui. l�..t.`!�-C3h�' �.- 1 � �! ( {P T{ 1 � '�^.�„'•`?'. '� '-=. .�r
dd F ° t v GUAlf
SUPPLY a M NUFACTURIN4
z5 + -
t _ c .� (.� .��,t.''.•-x.71 { S`£+r s t tiVk *i t r Kf ..
FLC R.IDA PRODUCT APPROVAL WO. 11551.2-82
w. _
ENGINEER LOAD TABLE: 0.,032" Aluminum GuIfLokTM 16"Wide Roof Panel over 15132"Plywood
Buildings having a'Roof Mean-Height s 20'-0";;Roof Slope:2"/12"'- 12'712"'Gable or Hip'Roof;Wind'Speeds;720=
1801r1ph;Exposure(;.'Risk Category11,'Enclosed Building, based on Florida-Building Code 2014:
WiIND FASTENER
120 130 140 150 160 170 180(MIN.114" SUBSTRATE
SPEED Penetration) (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER
SPACING SPACING SPACING SPACING SPACING SPACING SPACING
ZONE T #10 12x1.". CDX Assembly A Assembly-A -Assembly A Assembly A Assembly A :Assembly A Assembly A"
PLYWOOD . ,
ZONE 2 #10-12x1" PLYWOOD Assembly A Assembly A Assembly A Assembly A Assembly B Assembly B Assembly B
ZONE"3 #1CDX 0-12xi" Assembly A Assembly B Assembly B Assembly B Assembly B. Assembly B Assemb,3y 8
PLYWOC)D . .
1.)PANEL DESCRIPTION:GULFLOKTM, MIN. 0.028"ALUMINUM,7/8" RIB, 16" MAXIMUM COVERAGE, SNAP SEAM,
2.)PANEL FASTENER:THROUGH PANEL SLOT; (1)#10-12X1"PANCAKE TYPE A, old" MIN. PENETRATION THROUGH PLYWOOD.
3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:ASSEMBLY A: 52.5 PSF PANEL FASTENERS AT 51/s"O.C.;ASSEMBLY B:116.0 PSF
PANEL FASTENERS AT S!s"O.C. WITH ala"-5h6" DIAMETER CONTINUOUS BEAD OF TITEBOND WEATHERMASTER METAL ROOF
SEALANT ON THE MALE RIB. PRESSURE BASED ON UL 580/UL 1897 TESTING BY FORCE ENGINEERING&TESTING.
4,)PLYWOOD DECKING: MIN. %2" THICK, APA RATED PLYWOOD, GRADE C-D. MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA
BUILDING CODE 2014.
5.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING
CODE 2014
,,ZONE 2 HIP ROOF a Note:Dimension(a)is defined as 10%of the minimum width of the building or
ZONE 3—.•, 40°l0 of the mean height of the roof,whichever is smaller,however,(a)cannot be
less than either 4%of the minimum width of the building or 3 feet.
RIDGE
'r ASSEMBLY A
•_i
-16" COVERAGE
ZONE 1 T
SAVE
ZONE 2 GABLE ROOF a. —(1)#10-12 X 1"TYPE A PANCAKE— /
7=7— ------- 'a SPACING:SEE UPLIFT TABLE
RIDGE ASSEMBLY B
1/4"-5116"DIAMETER BEAD OF TITEBOND SEALANT
ZONE 1 —
�(1) #�10-12X�l"TYPE A PANCAKE
'. SPACING: SEE UPLIFT TABLE
''• ZONE 3 EAVE
FL# 11651.2 R2•JUNE 15,2015 _
LN
:it).c}ez_. t t f.._..f..